Records from 1997 to 2017. Most recent: inspection, 14 December 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
14 December 2017
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6326062
30 January 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6080510
6 April 2016
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5849978
23 March 2016
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5839043
4 January 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5790457
16 May 2012
Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4320775
21 September 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4161749
23 February 2011
Deficiency Check · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3947231
25 March 2010
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3712656
2 March 2010
Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3685501
9 December 2009
In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3653026
25 March 2009
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3423267
24 October 2008
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3361561
27 February 2008
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3153402
20 September 2007
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3062322
21 February 2007
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2863569
25 January 2007
Administrative Inspection · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2849618
30 March 2006
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2597742
8 March 2005
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2293736
23 August 2004
Re-Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2173998
19 April 2004
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2047504
16 December 2003
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1965098
26 February 2003
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1739567
8 April 2002
Construction Oversight · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1487916
20 March 2001
Re-Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1408716
25 September 2000
Plan Review "T" Boat
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1462149
19 July 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1053596
20 May 2000
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1430850
24 May 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 806543
4 May 1999
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1393172
31 December 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 811182
6 July 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1419968
20 May 1997
Initial Certification · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1421341
Construction/Loadline › Hull › Hull Plating
Issued 23 February 2011
Resolved
Water leak detected in port fwd wheel well. Delamination of front whell wells required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 April 2011
Resolved 6 April 2011
Resolution: Visual and water test perfomed. Results sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 March 2010
Resolved
Properly provide proof that 35 lb CO2 cylinder has been properly serviced.
Action required: 705 - Other - as specified
Due 2 April 2010
Resolved 23 February 2011
Resolution: Servicing record reviewed
Engineering › Bilge Water Management System › Pump
Issued 2 March 2010
Resolved
Properly inspect and adjust chain tension on Higgins pump system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2010
Resolved 23 February 2011
Resolution: Inspected higgins pump and tested sat.
Engineering › Pressure Vessel › Marking and Stamping
Issued 9 December 2009
Resolved
Prove proper installation of pressure vessels used for axel housing low air pressurization system.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 9 January 2010
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 25 January 2007
Resolved
Properly upgrade vessels fire detection system to include electrical supervision and move power supply to vital circuit.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2007
Construction/Loadline › Hull › Hull Plating
Issued 25 January 2007
Resolved
Properly prep, prime, and paint rusted areas in vessels bilges and exterior hull.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2007
Deck/Cargo › Holds/Tanks › Coaming
Issued 25 January 2007
Resolved
Properly repair both rear water tight doors, currently leaking water at the lower portion of the seal.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2007
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 16 December 2003
Resolved
Properly install engine space ventilation blower as per 46 CFR 182.460.
Condition: Improper Installation
Due 17 March 2004
Resolved 23 August 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 April 2002
Resolved
Label fuses 46-54 in electrical panel.
Condition: Improper Installation
Due 8 May 2002
Resolved 8 April 2002
Stability › Watertight Integrity › Hull Plating
Issued 8 April 2002
Resolved
Ensure aft port entry door is water tight.
Condition: Unknown
Due 8 May 2002
Resolved 8 April 2002
Engineering › Bilge Water Management System › Interface Detector
Issued 8 April 2002
Resolved
Replace aft high bilge alarm.
Condition: Unknown
Due 8 May 2002
Resolved 8 April 2002
Engineering › Non-conventional Propulsion/Steering › Housing (cycloidal)
Issued 8 April 2002
Resolved
Repalce hinge plate braket fwd.
Condition: Unknown
Due 8 May 2002
Resolved 9 April 2002
Electrical › Mast
Issued 8 April 2002
Resolved
Repalce stern light.
Condition: Unknown
Due 8 May 2002
Resolved 8 April 2002
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 8 April 2002
Resolved
Properly mount vapor detector in main cabin.
Condition: Improper Installation
Due 8 May 2002
Resolved 8 April 2002
Accommodation/Occupational Safety
Issued 20 March 2001
Resolved
REPAIR FRACTURED WELD IN STBD SIDE, AFT, CURTAIN TRACK.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Engineering
Issued 20 March 2001
Resolved
REPAIR ENGINE EXHAUST LEAK.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001