CAPT ROD

CAPT ROD is a 1968 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in February 2024, along with 6 deficiencies.

Records from 2016 to 2024. Most recent: inspection, 20 February 2024.

Built
1968
Last inspected
20 February 2024
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WY3785
Flag
UNITED STATES
Maury page id
psix-45829

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 7 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)59.2 ft × 20.5 ft × 6.0 ft
Registered tonnagegross 58 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHARKERS ISLAND BOAT WORKS INC · HARKERS ISLAND, NC, UNITED STATES · built 1968
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 11

20 February 2024 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7867754
14 June 2021 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7225123
14 June 2021 Examination of Repairs · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7225385
8 April 2021 Administrative Inspection · DAPI Audit · Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7171230
9 June 2020 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6971764
26 November 2019 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6858357
28 March 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6642241
21 February 2018 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6346912
7 November 2017 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6302216
21 March 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6107756
21 March 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5837269

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 June 2021 Resolved
A vessel must comply with the structural design requirements, for wood hull vessels Lloyds Yachts and small craft and in accordance with original designs and scantlings. Identified wood rot at the sheer streak where the hull meets the deck. Prior to carrying passengers, submit a repair proposal to the USCG MSD office in Coram NY. The repair proposal must be accepted and repairs must be completed with USCG oversight prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 April 2021 Resolved
Provisions must be made for closing supply ducts for spaces required to be protected by a fixed gas system. Identified 2 engine room, natural ventilation, air supply ducts where the ducts installed were not closeable. fabricate supply duct closure system to prevent CO2 from escaping in case of an emergency.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2021
Resolved 22 May 2021
Resolution: Provided foam inserts for the E.R. Supply and exhaust vents to prevent CO2 from escaping ICOE
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 22 April 2021 Resolved
Clean area in the main passenger compartment prior to carrying passengers. Identified main passenger compartment with paints and chemicals during the vessels maintenance period. O/O states the maintenance supplies will be removed from the vessel prior to service
Action required: 10 - Deficiency Rectified
Due 22 April 2021
Resolved 22 April 2021
Resolution: Area cleaned and gear stowed
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 April 2021 Resolved
A dry dock inspection in accordance with 46 CFR 176.600 must be conducted while the vessel is hauled out of the water in a dry dock. On wooden vessels fastenings may be required to be pulled for examination. Under 46 CFR 176.800 material conditions and standards not specified in 46 CFR sub-chapter T, must be maintained in acceptable standards as "good marine practice" and using guidance from NVIC 7-95, enclosure 1 chapter 4.K.2, existing vessels, built to sub-chapter T, fastener inspections should be conducted every 5th year of service in salt water. Complete a fastener inspection prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2021
Resolved 22 April 2021
Resolution: OCMI granted exyension IAW O/O request
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 November 2019 Resolved
Valve for NR3 void was found inoperable
Action required: 10 - Deficiency Rectified
Due 26 November 2019
Resolved 26 November 2019
Resolution: Valve fitted with new handle and assembly. tested and inspected arrangement.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 November 2019 Resolved
Valve for the generator exhaust found inoperable. valve and through hull were with in 6" of the water line
Action required: 10 - Deficiency Rectified
Due 26 November 2019
Resolved 26 November 2019
Resolution: Valve replaced. operated and inspected ne valve

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.