← All vessels
ELEFSIS
ELEFSIS is a 1996 freight ship. The Coast Guard has recorded 19 inspections since 1997, most recently in August 2014, along with 23 deficiencies and 1 operational control.
Records from 1997 to 2014. Most recent: inspection, 28 August 2014.
- Built
- 1996
- Last inspected
- 28 August 2014
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 23 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9118678 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA3318
458323
Flag
INDIA
—
Maury page id
psix-458323
Inspections, by type
…with no type recorded7
Years with a record
13 calendar years (1997–2014)
The 19 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it24176 - Convention (Subpart B), Net Ton
38852 - Convention (Subpart B), Gross Ton
83528 - Displacement, Ton
69893 - Dead Weight, Ton
38852 - Convention (Subpart B), Gross Ton
83528 - Displacement, Ton
69893 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 19
28 August 2014
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4960383
15 December 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4208960
9 January 2011
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3923399
12 December 2009
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3648429
5 November 2008
ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3357522
2 October 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3071243
27 September 2007
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3067124
11 August 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2744239
2 March 2006
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2594447
24 January 2005
Ballast Water Examination · ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2280038
17 June 2003
Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1820027
12 June 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1816948
1 November 2002
MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1699599
9 March 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 275365
12 August 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 431422
1 April 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 164202
31 March 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 426920
9 June 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 417658
28 September 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 408348
Deficiency record · 23
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 August 2014
Resolved
1730 - Oily-Water Separating Equipment - Vessel crew failed to verify recorded operational history of Oil Content Meter. PSC discovered that memory card from Oil Content Meter was missing, disabling the system's ability to record data - MARPOL Annex I/11, MEPC 107(49).
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 August 2014
Resolved
1730 - Oily Water Separating Equipment - Engineering Department was unaware that their Oil Content Meter (MEPC 107(49)) recorded operational history of the Oily Water Separator and did not know how to recall this information.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 9 January 2011
Resolved
The ships air compressor used to refill SCBA bottles was reported to be inoperable due to filter problems dating back to Sept. 2010. Crew was unable to refill a bottle due to a connection fitting. This was not reported to the Master, and therefore no report was submitted to the operating company. Recommend an internal audit of the vessels SMS. SOLAS 74(09 Cons) Ch. IX Reg 3.1 ISM Code 10.2.2.3
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 9 January 2011
Resolved
The number of spare charges on board was determined by the administration based on the vessel having an operable air compressor on board to refill SCBA bottles. The vessels air compressor has been inoperable for at least four months. SOLAS 74 (1997 cons) Ch. II-2 Reg. 17.1.1.2.2
Lifesaving › Lifeboat Equipment › Food Ration
Issued 9 January 2011
Resolved
Nine food rations in the starboard side life boat were no longer air tight. SOLAS 74 (1997 cons) Ch. III Reg. 38.5.1.18
Deck/Cargo › Mooring/Anchoring › Winch
Issued 9 January 2011
Resolved
There is a temporary repair on the forward spring line mooring wnich hydraulic line. SOLAS 74 (1997 cons) Ch. I Reg. 11b
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 January 2011
Resolved
The port side top rail adjacent to the number four cargo hold is wasted. ICLL Ch. II Reg. 25.2
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 9 January 2011
Resolved
The crew is using open flame lighters to test the fire detectors. SOLAS 74 (1997 cons) Ch. II-2 Reg. 13.1.13.
Engineering › Compressed Air System (control) › Compressor
Issued 9 January 2011
Resolved
The crew has rigged flexible ducts, leading to ventilation ducting from the vent to the deck air compressor due to over heating issues with that compressor. SOLAS 74(1997 cons) Ch. I Reg. 11b
Lifesaving › Lifeboat › Rigid Cover
Issued 11 December 2009
Resolved
PORT LIFEBOAT HAS CRACK IN INTERIOR OVERHEAD, STARBOARD SIDE-FORWARD. THE CRACK DOES NOT PENETRATE THE HULL AND IS ABOVE THE WATERLINE. CLASS IS TO VERIFY PROPER REPAIRS AND STRUCTURAL INTEGRITY OF THE AFFECTED AREA PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 27 September 2007
Resolved
The containment for the starboard side bunkering station has been cut and folded down. Class to verify that the containment is still adequate.
Lifesaving › Launching Appliances › Winch Brake
Issued 27 September 2007
Resolved
The dead man brake on the port side is inoperable. Class to attest to the proper operation of the dead man brake for the port side lifeboat.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 2 March 2006
Resolved
The Sewage Plants are not being maintained as per the manufacturer’s requirements. Daily, weekly, monthly, semi-annual and annual testing of the plant and its components are not being carried out. In addition to test the system the crew must take a sample using a chorine kit, which is not on board. Test kit must be placed on board and checks must be IAW manufacturer's requirements. Vsl has two MSD
Documentation › Logs/Records › Oil Record Book
Issued 2 March 2006
Resolved
C/E was using the wrong items numbers for OWS. He was still using the old number 15.2 instead of 15.1 when operating the OWS.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 2 March 2006
Resolved
Ship is missing its bell. Ship bell size must be provided as per COREGS Annex III, 300 mm.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 2 March 2006
Resolved
Mixed garbage was found throughout the vessel. Containers are not consistent in color coding or stenciling what items can and can not be placed in them. The incinerator is being used to burn everything however, Master and C/E stated that only oily rags and sludge were being burned. Garbage Plan needs to be more specific on what can and can not be burned and separation of garbage.
Stability › Unintentional Flooding › General
Issued 2 March 2006
Resolved
Several of the ballast vent floats were damaged or stuck at the top of the vent. During heavy weather these vents would allow water to enter the ballast tanks.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 March 2006
Resolved
Several pipes in the engine room have soft patches on them. The S/W cooling pump #2, S/W service pump #2 discharge pump. Ejector pump delivery line, S/W cooling line to Main engine, and air compressor cooler forward header.
Construction/Loadline › Structures
Issued 1 November 2002
Resolved
Door closures not securing Emergency Escape Doors in Eng room Escape trunk. Solas 78 II-2 Reg 45-3.1 LEGACY COMPONENT DESC: Door
Fire Fighting
Issued 31 March 1999
Resolved
Perform fire drill in the presence of U.S. Coast Guard. SOLAS 74 amd III/18. Correct prior to departure.
Lifesaving
Issued 31 March 1999
Resolved
Provide two type 1 personal floatation devices in the child size of under approximately 34kg. SOLAS 74amd III/7.2.1.1 Correct prior to departure.
Documentation
Issued 31 March 1999
Resolved
Revise oil transfer proceedure to include list if products carried._x001C_ 33 CFR 155.720. Correct prior to next oil transfer.
Navigation
Issued 31 March 1999
Resolved
Provide nonslip surface at steering gear compartment. SOLAS 74 amd II- 1/29. Correct prior to next U.S. port after sailing foreign.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.