Records from 1997 to 2026. Most recent: inspection, 22 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
22 April 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8354440
2 September 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8225203
6 June 2024
Administrative Inspection · Initial Certification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7926676
22 May 2024
Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 7917783
3 April 2024
Plan Review "T" Boat
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7889207
14 December 2007
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3115851
15 June 2004
Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2099459
22 January 2003
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1733822
31 October 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1362494
5 October 2001
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1074533
9 May 2001
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1062007
15 August 2000
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 821156
8 October 1999
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 887429
4 June 1999
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1416895
2 June 1998
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1466530
4 June 1997
Hull Examination · Initial Certification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1400607
15 May 1997
Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1416520
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 April 2026
Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section.
DD/ISE dates lapsed. Operations restricted until completion.
46CFR176.600(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2026
Resolved 22 April 2026
Resolution: DD/ISE completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 September 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Starboard engine throttle cable needs replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 17 September 2025
Resolution: Throttle cable replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2024
Resolved
As an alternative to complying with the provisions of this part, a vessel of not more than 19.8 meters (65 feet) in length, carrying not more than 12 passengers, and propelled by gasoline or diesel internal combustion engines, other than a High Speed Craft, may comply with ABYC H-2, ABYC H-22, ABYC H-24, ABYC H-25, ABYC H-32, ABYC H-33, ABYC P-1, and ABYC P-4
46 CFR 1182.130
Vessel limited to 12 passengers until permanent fuel tank is installed iaw 46 CFR 182.440
Action required: 705 - Other - as specified
Due 26 June 2024
Resolved 3 July 2024
Resolution: Vessel installed fuel tanks IAW 46 CFR 182.440
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2024
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
46 CFR 185.604(b)
Properly mark all adult and child life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2024
Resolved 3 July 2024
Resolution: All Lifejackets were marked
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 6 June 2024
Resolved
Table 181.500(b) of this section indicates the minimum required classification for each space listed.
46 CFR181.500(b)
Vessel is missing 2-A extinguisher. Extinguisher to be mounted in forward passenger area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2024
Resolved 3 July 2024
Resolution: Vessel installed fire extinguishe 2-a in forward passenger area
Construction/Loadline › Structures › Deck Plating
Issued 15 June 2004
Resolved
Repair three fractured welds on port and starboard pontoons, two welds on starboard pontoon aft at pontoon to deck frame connection, one port pontoon aft at pontoon to deck frame connection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 July 2004
Resolved 14 December 2007
Construction/Loadline › Hull › Hull Plating
Issued 15 June 2004
Resolved
Provide air test of each bulkhead in pontoon port and starboard.
Action required: 705 - Other - as specified
Due 16 July 2004
Resolved 14 December 2007
Construction/Loadline › Hull › Bottom Plating
Issued 31 October 2001
Resolved
PROVE OPERATION OF BILGE PUMPS, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 October 2001
Resolved
PROVE OPERATION OF NAVIGATION LIGHTS, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 31 October 2001
Resolved
PROVIDE 2 PORTABLE LIGHTS, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Fire Fighting › Combustible Materials › Ceilings
Issued 31 October 2001
Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Lifesaving › Buoyant Apparatus › Approval
Issued 31 October 2001
Resolved
PROVIDE SERVICEABLE FIRST AID KIT, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 31 October 2001
Resolved
POST CERTIFICATE OF INSPECTION ONBOARD VESSEL, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Documentation › Certificates/Documents › Permit to Carry Excursion Party (CG-949)
Issued 31 October 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 October 2001
Resolved
REPLACE 60 FEET OF BUOYANT LINE ON RING BUOY AND INSTALL WATER LIGHT ATTACHED WITH 3 FEET OF BUOYANT LINE.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Documentation › Certificates/Documents › Annex VI Statement of Voluntary Compliance
Issued 31 October 2001
Resolved
PROVIDE PROOF OF FIRST AID AND CPR TRAINING, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 November 2001
Resolved 14 December 2007
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 31 October 2001
Resolved
PROVIDE PROOF OF DRUG AND ALCOHOL PROGRAM, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Documentation › Logs/Records › Logbook (official)
Issued 31 October 2001
Resolved
PROVIDE TRAINING TO CREW AND RECORD IN TRAINING LOG, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 31 October 2001
Resolved
POST EMERGENCY INSTRUCTIONS, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Navigation › Piloting/Steering › Marine Charts
Issued 31 October 2001
Resolved
PROVIDE CURRENT CHARTS AND PUBLICATION FOR OPERATING AREA, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Lifesaving › Hand Flares › Storage
Issued 31 October 2001
Resolved
MARK FLARE BOX "DISTRESS SIGNAL", PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 31 October 2001
Resolved
PROVE OPERATION OF VHF RADIO, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Lifesaving › Rescue Boat › Bailing Capability
Issued 31 October 2001
Resolved
CONDUCT PASSENGER ORIENTATION AND PROVIDE PASSENGER COUNT, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Documentation › Markings/Placards › Official Number (US)
Issued 31 October 2001
Resolved
DISPLAY OFFICIAL NUMBER OF VESSEL ON THE HULL, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Documentation › Markings/Placards › Certificate of Number (state)
Issued 31 October 2001
Resolved
PROVIDE VAILD STATE REGISTRATION, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 31 October 2001
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHER, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Lifesaving › Lifebuoys › Quantity
Issued 31 October 2001
Resolved
PROVIDE RING BUOY FORWARD, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 October 2001
Resolved
SERVICE BATTERIES ON AFT DECK, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
Documentation › Certificates/Documents › FCC SSL
Issued 31 October 2001
Resolved
PROVIDE FCC LICENSE.
Condition: Unknown
Due 17 November 2001
Resolved 14 December 2007
System not recorded
Issued 15 August 2000
Resolved
Prior to placing the vessel in service, make vessel available for complete deckside inspection.
Condition: Unknown
Due 1 May 2001
Resolved 28 May 2004
Documentation
Issued 4 June 1999
Resolved
Provide proof of annual drug testing report sent to USCG Headquarters.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Construction/Loadline
Issued 4 June 1999
Resolved
Prove proper operation of hand bilge pump.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Lifesaving
Issued 4 June 1999
Resolved
Install new ring buoy light battery and prove proper operation.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Fire Fighting
Issued 4 June 1999
Resolved
Install 3 fire buckets in accirdance with 46CFR181.610
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Engineering
Issued 4 June 1999
Resolved
Replace existing fuel hoses with hoses that meet SAE J-1942 standards or provide proposal for change in accordance with 46CFR182.455 and 182.720(e).
Condition: Unknown
Due 4 July 1999
Resolved 28 May 2004
Resolution: Vessel COI revoked.
Lifesaving
Issued 2 June 1998
Resolved
PRIOR TO OPERATING WITH PASSENGERS WITH ONE MASTER, INSTALL REAR-VIEW, CONVEX MIRROR AT OPERATING STATION FOR EASY VIEWING OF AFT PASSENGER AREA.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Fire Fighting
Issued 2 June 1998
Resolved
REMOUNT B-II PORTABLE FIRE EXTINGUISHER AT OPERATING STATION WITH PROPER MOUNTING BRACKET.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998