Records from 2016 to 2026. Most recent: inspection, 26 May 2026.
Inspection history · 16
26 May 2026
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8356999
20 March 2026
Drydock Exam · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8328410
27 January 2025
DAPI Audit · COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8067644
11 March 2024
Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7879180
18 November 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7596516
27 October 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7588367
2 July 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7505291
27 January 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7386978
13 May 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7196037
4 December 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7106461
7 October 2020
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7073588
12 February 2020
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6908145
28 January 2019
Administrative Inspection · Annual Inspection · Drydock Exam · DAPI Audit · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6616344
27 March 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6376306
7 March 2017
Hull Examination · Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6100509
14 March 2016
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5859731
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 May 2026
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. RHIB vessel missing 04 bolts that connect the collar to the FRP hull. Provide 04 bolts to attach collar to hull.
46 CFR 177.300 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2026
Resolved 26 May 2026
Resolution: 04 bolts installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 May 2026
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge pump indicator at helm not operational. Provide visual indicator for bilge pump.
46 CFR 182.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2026
Resolved 26 May 2026
Resolution: New light installed and operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2026
Resolved
Gauges to indicate engine revolutions per minute (RPM) and lube oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Starboard gauge not operational. Provide operational starboard engine gauge.
46 CFR 182.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2026
Resolved 26 May 2026
Resolution: New gauge installed and operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 May 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Signs of hydraulic oil leakage observed at steering wheel. Make repairs to steering system to eliminate hydraulic leak.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2026
Resolved 26 May 2026
Resolution: Steering wheel disassembled and leak repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 May 2026
Resolved
A red warning sign at the switch must state that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one complete change of air in the space served. No warning sign provided. Provide red warning sign.
46 CFR 182.460(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2026
Resolved 5 June 2026
Resolution: Red blower sign provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2026
Resolved
Independent fuel tanks must be designed and constructed as described in this paragraph. Vessel has significant pitting on fittings. Make approved repairs and conduct pressure test.
46 CFR 182.440 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2026
Resolution: Repairs completed by Marine Engineering and air testing completed at 5 PSI.
Construction/Loadline › Hull › Side Shell
Issued 7 March 2017
Resolved
Found area of delaminated fiberglass in stern transom area.
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 30 March 2017
Resolution: All delaminated FRP in transom area was located cropped out and replaced in kind. All items and repair found sat.