MAURY USCG vessel records Sign in
← All vessels

MISS GREEN RIVER II

MISS GREEN RIVER II is a 1968 passenger vessel (inspected). The Coast Guard has recorded 40 inspections since 1985, most recently in July 2009, along with 35 deficiencies.

Records from 1985 to 2009. Most recent: inspection, 14 July 2009.

Built
1968
Last inspected
14 July 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-45837

Inspections, by type

…with no type recorded6
Years with a record 24 calendar years (1985–2009)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it11 - Regulatory (Subpart C or D), Net Ton
19 - Regulatory (Subpart C or D), Gross Ton
0 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 40

14 July 2009 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3534159
8 January 2008 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3126613
29 June 2006 COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2695019
17 May 2005 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2414166
12 May 2004 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2070426
15 April 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2045411
16 March 2004 Administrative Inspection
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2025271
4 June 2003 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1814725
19 July 2002 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1650007
7 May 2002 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1620093
12 April 2001 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1379396
13 April 2000 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1462081
17 June 1999 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1188481
8 April 1999 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1472762
27 October 1998 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1436156
7 April 1998 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1468428
25 June 1997 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1438605
6 May 1997 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1428756
15 May 1996 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1083226
18 April 1996 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1080783
30 May 1995 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1183871
11 April 1995 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1160110
6 May 1994 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1168604
12 November 1993 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1137613
5 May 1993 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1150282
15 April 1993 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1440683
5 July 1992 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 141920
24 June 1992 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 953751
2 April 1992 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 958871
2 July 1991 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1252618
4 April 1991 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 930924
19 April 1990 Re-Inspection · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 925654
29 March 1989 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1343201
25 March 1988 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 989803
9 April 1987 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1022244
9 April 1987 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1328719
18 September 1986 Examination of Repairs
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1310031
20 March 1986 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 994203
4 November 1985 Credit Drydock
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1299098
28 March 1985 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1287348

Deficiency record · 35

Documentation › Logs/Records › MIS Form
Issued 29 June 2006 Resolved
Provide MIS report for current year.
Due 14 August 2006
Resolved 14 August 2006
Engineering › Bilge Water Management System › Valve
Issued 12 June 2006 Resolved
Prove proper operation of bilge pick up system ion #1 void. Indications are that there is a faulty valve on the system.
Due 12 July 2006
Resolved 21 June 2006
Electrical › Electric Supply System (service) › Cable
Issued 12 June 2006 Resolved
Prove proper repair and/or replacement of exposed battery cables on #1 (STBD) main engine.
Due 12 July 2006
Resolved 21 June 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 June 2006 Resolved
Provide documentation of annual servicing of fixed system and portable extiguishers.
Due 26 June 2006
Resolved 21 June 2006
Engineering › Fuel Oil Service System › Valve
Issued 12 June 2006 Resolved
Replace emergency fuel shutoff valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 June 2006 Resolved
Prove proper operation of watrlight and provide quick acting release clips on lines.
Due 26 June 2006
Resolved 21 June 2006
Documentation › Logs/Records › Drug Test Records
Issued 12 June 2006 Resolved
Provide all needed verification documentation for complete DAPI audit as indicated on inspection sheet.
Due 26 June 2006
Resolved 14 August 2006
Lifesaving
Issued 8 April 1999 Resolved
REPLACE/RENEW RING BUOY FLOAT LIGHT.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Electrical
Issued 8 April 1999 Resolved
LABEL THE SHIP TO SHORE ELECTRICAL BREAKER FOR IDENTIFICATION.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Lifesaving
Issued 8 April 1999 Resolved
PROVIDE A PORTABLE LIGHT IN THE VICINITY OF THE ENGINE ROOM ENTRANCE.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Lifesaving
Issued 8 April 1999 Resolved
LABEL THE EMERGENCY FLARE CONTAINER "DISTRESS SIGNALS".
Condition: Unknown
Due 8 April 1999
Resolved 15 April 1999
Lifesaving
Issued 8 April 1999 Resolved
PROVIDE A BUOYANT LIFELINE ON THE RING BUOY IN ACCORDANCE WITH 46 CFR 180.70
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Construction/Loadline
Issued 8 April 1999 Resolved
LABEL BILGE MANIFOLD VALVES.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Fire Fighting
Issued 27 October 1998 Resolved
REROUTE PULL CABLE AT EXTINGUISHER END TO ALLOW POSITIVE ACTIVATION OF SYSTEM.
Condition: Unknown
Due 7 December 1998
Resolved 7 December 1998
Fire Fighting
Issued 27 October 1998 Resolved
REPLACE GATE VALVE FOR FIRE PUMP SUCTION.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Electrical
Issued 6 May 1997 Resolved
REPLACE THE STARBOARD SIDE SHORE POWER CABLE PLUG AND VESSEL RECEPTACLE.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Accommodation/Occupational Safety
Issued 6 May 1997 Resolved
REPLACE THE BROKEN GLASS IN THE WINDOW FORWARD OF THE CONTROL STATION.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Accommodation/Occupational Safety
Issued 6 May 1997 Resolved
LIFT AND SUPPORT THE STARBOARD SEWAGE SYSTEM DRAIN LINE TO PREVENT CHAFING WITH THE STEERING SYSTEM MAIN SHAFT.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Unknown
Issued 6 May 1997 Resolved
ESTABLISH A CHEMICAL TESTING PROGRAM IN ACCORDANCE WITH 46 CFR 16.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Lifesaving
Issued 18 April 1996 Resolved
RENEW RETROREFLECTIVE TAPE ON 73 PFD'S IDENTIFIED DURING INSPECTION. VESSEL IS RESTRICTED TO DAYLIGHT OPERATIONS UNTIL THIS ITEM CORRECTED.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 18 April 1996 Resolved
POST LIFE JACKET DONNING INSTRUCTIONS IN CONSPICUOUS PLACES THAT ARE VISIBLE TO THE CREW AND PASSENGERS.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Documentation
Issued 18 April 1996 Resolved
LOG MONTHLY AND QUARTERLY TRAINING PER 46CFR185.420 AND 46CFR185.524 OF THEINTERIM FINAL RULE DATED JANUARY 10, 1996.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Engineering
Issued 18 April 1996 Resolved
EFFECT PERMANENT REPAIRS TO THE CRACKED FUEL OIL SUPPLY LINE PENETRATING THE FORWARD BULKHEAD IN THE ENGINE ROOM.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 11 April 1995 Resolved
PROVIDE ONE (01) CHILD SIZED PFD.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Engineering
Issued 12 November 1993 Resolved
PROPERLY SECURE KEROSENE FUEL TANK._x001C_ FUEL TANK FOR THE KEROSENE HEATER WAS FOUND TO BE LOOSE FROM ITS ANCHORAGE TO THE DECK DUE TO MATERIAL FAILURE. THIS TANK MUST BE PROPERLY ATTACHED TO THE DECK TO RESTRICT ANY MOVEMENT.
Condition: Unknown
Due 12 November 1993
Resolved 12 November 1993
Engineering
Issued 12 November 1993 Resolved
RUN THE KEROSENE TANK VENT TO EXTERIOR OF THE COMPARTMENT._x001C_ THE TANK VENT IS CURRENTLY INSIDE THE COMPARTMENT AND MUST EXTENDED TO THE OUTSIDE ATMOSPHERE.
Condition: Unknown
Due 12 November 1993
Resolved 12 November 1993
Navigation
Issued 15 April 1993 Resolved
INSTALL CORRECT BULB IN THE VESSELS NAVIGATION LIGHTS.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Lifesaving
Issued 15 April 1993 Resolved
PROVIDE SIX (6) RED FLARES AND SIX (6) ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Construction/Loadline
Issued 2 April 1992 Resolved
Prove the operation of the bilge piping system on board the vessel per 46CFR182.25-1(a) prior to carrying passengers and not later than the compliance date.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Navigation
Issued 2 April 1992 Resolved
Provide a copy of the Inland Navigation Rules on board the vessel per 33CFR88.05 prior to the compliance date.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Construction/Loadline
Issued 4 April 1991 Resolved
Replace gaskets on hatch covers to #2 and #4 voids as required by 46CFR171.124(a); prior to compliance date.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Construction/Loadline
Issued 4 April 1991 Resolved
Attach captive chains to hatch covers on all voids as required by 46CFR171.124(b)(2); prior to compliance date.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Electrical
Issued 4 April 1991 Resolved
Replace worn electrical wire to navigation light at navigation station as required by 46CFR183.05-45(e); prior to compliance date.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Electrical
Issued 4 April 1991 Resolved
Reattach electrical plug to electrical wire on soda pop machine as requiredby 46CFR183.05-45(j); prior to compliance date.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Accommodation/Occupational Safety
Issued 4 April 1991 Resolved
Provide protective cover on back of toilets in bathrooms to prevent unlimited passenger access to 24 volt electric vacuum system as required by46CFR183.05-50(b)(1); prior to compliance date.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.