DISCOVERY

DISCOVERY is a 1997 passenger vessel (inspected). The Coast Guard has recorded 70 inspections since 1997, most recently in April 2026, along with 204 deficiencies, 1 operational control, 1 with no removal date recorded and 2 casualty investigations in 2012.

Records from 1997 to 2026. Most recent: inspection, 15 April 2026.

Built
1997
Last inspected
15 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDF9194
458555
Flag
UNITED STATES
367502650
Maury page id
psix-458555

Inspections, by type

…with no type recorded4
Years with a record 28 calendar years (1997–2026)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it55 - Simplified, Gross Ton
51 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDP9618MMSI 367502650 · active · compulsorily equipped · granted 15 January 2025, expires 15 January 2035
WDF9194MMSI 367502650 · expired · compulsorily equipped · granted 25 August 2011, cancelled 30 October 2021
WCX9166MMSI not assigned · expired · compulsorily equipped · granted 14 January 1998, cancelled 15 March 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 70

15 April 2026 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8368338
16 December 2025 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8284022
18 August 2025 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8229021
18 December 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8049064
30 October 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7816804
7 August 2023 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7761674
15 September 2022 COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7560037
28 January 2021 Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7132638
17 September 2020 COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7175410
13 July 2020 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7009111
12 September 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6810629
12 September 2018 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6539218
1 July 2018 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6462591
14 September 2017 DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6266216
23 May 2017 In-Service Inspection · Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6154911
14 September 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6000315
19 June 2016 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5912432
26 August 2015 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5226433
22 October 2014 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5009754
12 March 2014 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4814489
29 July 2012 Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4402114
21 June 2012 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4350641
25 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4231169
15 December 2011 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4231180
8 August 2011 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4108765
1 October 2010 DAPI Audit
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4110005
14 September 2010 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3850134
25 September 2008 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3325729
17 September 2007 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3059177
7 May 2007 Internal Structural Exam · Deficiency Check · Hull Examination · In-Service Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2923635
20 September 2006 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2782485
19 September 2006 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2781547
18 September 2006 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2780802
14 September 2006 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2770012
14 August 2006 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2746427
7 July 2006 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2704087
4 November 2005 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2528051
10 September 2005 COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2488628
12 April 2005 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2331741
2 December 2004 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2255911
9 November 2004 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2240953
25 May 2004 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2077391
11 September 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1902205
11 September 2003 In-Service Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1911520
2 July 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1832834
5 June 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1810036
20 May 2003 Periodic Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1797249
2 April 2003 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1767586
1 September 2002 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1776907
19 September 2001 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1370302
12 April 2001 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1366306
13 March 2001 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1064525
13 February 2001 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1057907
23 October 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 823006
7 September 2000 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1365972
18 July 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1052430
24 March 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1050070
27 October 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1131700
15 October 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 789013
21 September 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1030870
17 September 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1030869
8 September 1999 MARPOL Annex V Examination · Deficiency Check · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361098
20 August 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 144460
20 July 1999 Plan Review "T" Boat
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1103840
22 June 1999 Plan Review "T" Boat
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1079322
23 April 1999 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1369136
8 October 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 803346
8 September 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 797882
12 November 1997 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1120666
7 September 1997 Hull Examination · Initial Certification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1121829

Deficiency record · 204

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 December 2024 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The FCC Safety Certificate and FCC Radio Authorization is expired. 46 CFR § 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2025
Resolved 22 January 2025
Resolution: The operator received a new FCC Safety Certificate and FCC Station Authorization.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 December 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. The port rudder packing gland is leaking water into the port lazarette space. The leak is approximately one liter every 5 days. The packing gland shall be replaced and made watertight. 46 CFR § 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2025
Resolved 13 January 2025
Resolution: The port rudder packing gland was replaced and the steering system is no longer leaking.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 October 2023 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: (1) A light to indicate discharge; and (2) An audible alarm that sounds upon discharge. The audible and visual alarm is not operational on the port side FireBoy system protecting the machinery space. The audible alarm is not operational on the starboard side FireBoy system protecting the machinery space. 46 CFR 181.420(b)
Action required: 705 - Other - as specified
Due 6 November 2023
Resolved 6 November 2023
Resolution: The operator replaced the visual and audible indicators for the pre-engineered fire system. The alarms were tested and found to be satisfactory by the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2023 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J–1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. The following restrictions apply: For the purpose of flexibility only, flexible hose installed in lengths of not more than 760 millimeters (30 inches) and subject to pressures of not more than 35 kPa (5 psig), may meet the following requirements: USCG Type A1, A2, B1, or B2 flexible hose may be accepted in accordance with 33 CFR part 183, subpart J. Flexible hose was found installed on the port and starboard fuel tank delievery lines and next to the main engine fuel pump. The flexible hose is less than 30" but does not meet USCG A1 fuel hose standards. 46 CFR 182.720(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2023
Resolved 14 November 2023
Resolution: The operator installed USCG A1 flexible fuel hose in areas less than 30".
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2023 Resolved
All equipment, including switches, fuses, lampholders, etc., must be suitable for the voltage and current utilized. Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. Conductors must be protected in accordance with their current carrying capacities. Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Each circuit breaker must meet UL 489 (incorporated by reference; see 46 CFR 175.600) or other standard specified by the Commandant. The primary branch overcurrent protection on the starboard side is a 100 amp 220V AC double pole breaker which does not protect the 12V DC 8 AWG conductor based on its current carrying capacity or DC current. The port side primary overcurrent protection could not be identified by its current rating or breaker size. Both overcurrent protection devices will be replaced with a UL listed fuse or UL 489 breaker rated at the conductor's current carrying capacity. 46 CFR 183.380
Action required: 705 - Other - as specified
Due 31 October 2023
Resolved 31 October 2023
Resolution: The operator replaced the double pole AC breaker with a DC rated UL listed 60 amp cartridge fuse. The port side breaker was replaced with a UL 489 breaker rated at 60 amps for DC current.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2023 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. The port and starboard starting batteries are not secured to prevent shifting or movement. 46 CFR 183.350(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2023
Resolved 14 November 2023
Resolution: The port and starboard starting batteries were found secured to prevent shifting or movement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The terminal strip for the 12V DC circuit located under the operating console was found with heavy corrosion creating resistance and heat when energized. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2023
Resolved 14 November 2023
Resolution: The operator cleaned the corrosion off of the terminal strip for the 12V DC circuit located under the operating console.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2023 Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The battery conductors to the main engine are not supported and installed in the bilge. 46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2023
Resolved 13 November 2023
Resolution: The battery conductors to the main engine were found supported and installed out of the bilge.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 October 2023 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The port and starboard machinery space have a rectangular cover over the access to each space that is not vapor tight which permits the passage of the FireBoy agent outside of the space if discharged. 46 CFR 182.465(h)
Action required: 705 - Other - as specified
Due 6 November 2023
Resolved 6 November 2023
Resolution: The port and starboard machinery space's rectangular cover over the access to each space was found vapor tight. The operator installed gasket material to ensure tightness.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 October 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The port and starboard main engines do not have guards for the rotating belts which endangers personnel entering the engine room while the machinery is energized. 46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2023
Resolved 13 November 2023
Resolution: The operator installed guards on the rotating parts for the port and starboard main engines.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 30 October 2023 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies. Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The master was unable to provide a record of crew drills. 46 CFR 185.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2023
Resolved 13 November 2023
Resolution: Abandon ship and man overboard drills and training were found to be logged on this date.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 October 2023 Resolved
The lights prescribed by these Rules shall, if carried, also be exhibited from sunrise to sunset in restricted visibility and may be exhibited in all other circumstances when it is deemed necessary. The stern light was not operational when tested and the arc of visibility is larger than what is permitted by the navigation rules. 33 CFR 83.20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2023
Resolved 13 November 2023
Resolution: The stern light was found operational when tested with the appropriate arc of visibility.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 October 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The FCC station license is expired. 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 30 November 2023
Resolution: The FCC technician issued a new station license.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 September 2022 Resolved
VSL must comply with FCC requirements for station license. On board FCC station license expired on 2021.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2022
Resolved 22 September 2022
Resolution: POC has updated the FCC station license on line with FCC. Waiting for official license via mail.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 September 2022 Resolved
Master shall ensure that monthly test of EPIRB is performed and logged. No records of conducted EPIRB monthly test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2022
Resolved 22 September 2022
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 September 2022 Resolved
VSL operates on high seas must have on board FCC Type, Cat I, 406 MHz EPIRB. Found on board EPIRB with expired NOAA registration and battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2022
Resolved 22 September 2022
Resolution: POC decided to remove expired EPIRB from VSL. VSL's route is less than 3 NM from shore.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 September 2022 Resolved
Fixed gas fire extinguisher system must be service and maintained annual. Last services conducted on board fire protection equipment was APR 2021.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2022
Resolved 22 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 September 2022 Resolved
Wire must be protected from environment. Found several bilge pumps with improper wire connections, conductors are exposed to bilge water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2022
Resolved 22 September 2022
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 15 September 2022 Resolved
Company must has drug and alcohol program. No records of current drug and alcohol program o f board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2022
Resolved 22 September 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 July 2020 Resolved
Vessel inspected under subcahpter T may not operate without having on board a valid USCG COI. Vessel's hull exam and is overdue.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2021
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 September 2019 Resolved
VSL must have valid FCC Safety Radio Certificate. Provide proof of valid FCC Certificates.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 25 September 2019
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 12 September 2019 Resolved
Vessel must conduct crew training once every three months. Provide proof of conducted training.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 25 September 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 September 2019 Resolved
Provide up-to-date light list and tide tables.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 25 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 September 2019 Resolved
EPIRB must have current NOAA registration. Provide proof of EPIRB registering with NOAA.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 25 September 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 September 2019 Resolved
FGFE must be service and test annually by qualified individual. Proved proof of completed services.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 25 September 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 September 2019 Resolved
First aid kit content must not have expired items. Replace expired items in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 25 September 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 September 2018 Resolved
Vessel must have valid FCC Safety Certificate as required by 47CFR80. Provide proof of valid FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 19 September 2018
Resolved 19 September 2018
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 September 2018 Resolved
A space with non-watertight closure on main deck must have bilge high level alarms as required by 46 CFR 182.530. Install bilge high level alarm in port and starboard space with non- water tight hatches.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 September 2018
Resolved 19 September 2018
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 September 2017 Resolved
Vessel must have up-to-date light list, coastal pilot, local notice to mariners and charts as required by 46 CFR 184.420
Due 21 September 2017
Resolved 21 September 2017
Engineering › Reduction Gearing/Clutches › Hose
Issued 14 September 2017 Resolved
Replace non-metallic hoses on reduction gear heat exchanger.
Due 21 September 2017
Resolved 21 September 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 September 2017 Resolved
Replace wasted through-hull fittings on port & starboard exhaust discharge pipes.
Due 21 September 2017
Resolved 21 September 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 September 2017 Resolved
Remove dead end wires in port engine compartment.
Due 21 September 2017
Resolved 21 September 2017
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 14 September 2017 Resolved
Repair inoperable operating indicator for forward bilge pumps.
Due 21 September 2017
Resolved 21 September 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 September 2017 Resolved
Repair inoperable bilge high level alarm for starboard steering compartment.
Due 21 September 2017
Resolved 21 September 2017
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 14 September 2017 Resolved
Provide two portable lights.
Due 21 September 2017
Resolved 21 September 2017
Stability › Weathertight Integrity › General
Issued 14 September 2017 Resolved
Replace wasted hatch frames on forward water tight hatch.
Due 21 September 2017
Resolved 2 October 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Piston
Issued 23 May 2017 Resolved
Vessel must be in compliance with standard for machinery required in 46 CFR 176.800. Conduct repairs and demonstrate proper operations of the port propulsion engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 September 2016 Resolved
All wire and cable must be protected from the weather as required by 46 CFR 183.340. wire conductor to mast all round light are exposed. Make proper wire protection
Due 28 September 2016
Resolved 21 September 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 14 September 2016 Resolved
Portable CO2 must be in good general condition as required by 46 CFR 176.810. Replace (02) portable CO2 with excessive corrosion.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2016
Resolved 14 September 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 September 2016 Resolved
Vessel must have visual and audible alarms at the operator station as required by 46 CFR 182.530. Repair inoperable bilge high level alarm in port steering compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2016
Resolved 14 September 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 September 2016 Resolved
Deck rails must be designed and construct to withstand a point of load of 200 lbs as required by 46 CFR 177.900. Repair upper deck hand rail with cracked welds.
Due 28 September 2016
Resolved 21 September 2016
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 14 September 2016 Resolved
Propulsion engine must have jacket water discharge temperature gauge as required by 46 CFR 182.410. Repair inoperable engine temperature gauge on port engine.
Due 28 September 2016
Resolved 21 September 2016
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 September 2016 Resolved
Vessel 26 and 65 feet long must have 1 fixed power pump and 1 portable hand pump or fixed hand pump as required by 46 CFR 182.520. Install missing fixed hand pump.
Due 28 September 2016
Resolved 21 September 2016
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 14 September 2016 Resolved
Waste receptacles must be constructed of non combustible material withy no opening in the side or bottom as required by 46 CFR 177.405. Replace existing plastic waste receptacle.
Due 28 September 2016
Resolved 21 September 2016
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 September 2016 Resolved
Submersible electric bilge pump must meet requirements in UL 1113 as required by 46 CFR 182.520. Demonstrate proper operation of the bilge pump in port forward space.
Due 28 September 2016
Resolved 14 September 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 September 2016 Resolved
Battery component must be in operational status as required by 46 CFR 186.806. Repair inoperable ammeter for STBD battery.
Due 28 September 2016
Resolved 21 September 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 14 September 2016 Resolved
Program MMSIM on VHF's DSC and conduct training to crew as required by 47 CFR 80.905(a)(1).
Due 28 September 2016
Resolved 21 September 2016
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 August 2015 Resolved
EPIRB testing must be conducted and logged on monthly bases. No evidence of logged EPIRB testing. 46 CFR 185.728
Due 3 September 2015
Resolved 3 September 2015
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 August 2015 Resolved
Navigation light must be in good condition and operate properly. Stern light was extinguish. 46 CFR 183.420
Due 3 September 2015
Resolved 3 September 2015
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 August 2015 Resolved
FGFE must be serviced and tested annually. Tag on fire boys FGFE is dated 2014. 46 CFR 181.420
Due 3 September 2015
Resolved 3 September 2015
Engineering › Fuel Oil Service System › Filter
Issued 26 August 2015 Resolved
All machinery installation must comply with manufacture required parts. Found fuel filter housing cracked and leaking fuel. Repair as original. 46 CFR 182.455
Due 3 September 2015
Resolved 3 September 2015
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 August 2015 Resolved
Flexible hoses designed for use with hose clamps. Found missing hose clamps on port & STBD engines cooling system. 46 CFR182.720
Due 3 September 2015
Resolved 3 September 2015
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 26 August 2015 Resolved
Engine must have jacket water discharge temperature gauge. Inoperable installed port temperature gauge. 46CFR182.410
Due 3 September 2015
Resolved 3 September 2015
Construction/Loadline › Hull › Side Shell
Issued 26 August 2015 Resolved
A positive action valve must be provide to any openings below vessel weather deck. Found thru hull fittings in port & STBD engine room with temporary caps. 46 CFR 179.350
Due 3 September 2015
Resolved 3 September 2015
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 August 2015 Resolved
Vessel must have visual and audible bilge high level alarm at the control station. Port engine room light not working, port steering audible not working, STBD engine room audible and visual are not working and steering no audible. 46 CFR 182.530
Due 3 September 2015
Resolved 3 September 2015
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 August 2015 Resolved
Vessel must carry a first aid kit approved in accordance with 46CFR160.041. Found partial filled first aid kit.
Due 3 September 2015
Resolved 3 September 2015
Navigation › Piloting/Steering › Marine Charts
Issued 22 October 2014 Resolved
Vessel has 2001 chart. Provide update charts. 46CFR184.420
Due 30 October 2014
Resolved 6 November 2014
Lifesaving › Lifefloat › Float-free Link
Issued 22 October 2014 Resolved
No float-free link on 10 person life float. Install appropriate float-free link to 10 person life float. 46CFR180.130
Due 30 October 2014
Resolved 6 November 2014
Lifesaving › Hand Flares › Quantity
Issued 22 October 2014 Resolved
Found only 4 red flares on board. Must have 6 red for limited coast wise route. 46CFR180.68
Due 30 October 2014
Resolved 6 November 2014
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 October 2014 Resolved
Faded markings on life buoys. VSL name must be marked or painted in clearly legible letters and numbers. 46CFR185.604
Due 30 October 2014
Resolved 6 November 2014
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 October 2014 Resolved
EPIRB registration expired on AUG 2013. Update EPIRB registration. 46CFR180.64
Due 30 October 2014
Resolved 6 November 2014
Fire Fighting › Fire Bucket › Stenciling
Issued 22 October 2014 Resolved
Faded stenciling ob fire buckets. Stenciled in contrasting color with bucket. 46CFR181.610
Due 30 October 2014
Resolved 6 November 2014
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 1 October 2010 Resolved
46 CFR 4.06: No proof of arrangements made for post-casualty testing after hours.
Due 1 November 2010
Resolved 1 March 2011
Resolution: Proof of arrangements for after hours provided to the satisfaction of the attending USCG.
Operations/Management › Drug and Alcohol Testing › Testing, Reasonable Cause
Issued 1 October 2010 Resolved
46 CFR 16.250 and 33 CFR 95: Employer could not provide information regarding arrangements for testing as required for reasonable cause.
Due 1 November 2010
Resolved 1 March 2011
Resolution: Corrected to the satisfaction of the attending USCG.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 1 October 2010 Resolved
46 CFR 16.401: Failure to have EAP displayed for hotline numbers and SAP name/contact information.
Due 1 November 2010
Resolved 1 March 2011
Resolution: Displayed to the satisfaction of the attending USCG.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 1 October 2010 Resolved
46 CFR 16.401: Failure to have proof of training for Supervisor and crewmembers.
Due 1 November 2010
Resolved 1 March 2011
Resolution: Proof of training submitted to USCG.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 1 October 2010 Resolved
46 CFR 16.500: Did not have proof of MIS report for 2009.
Due 1 November 2010
Resolved 1 March 2011
Resolution: Proof of MIS report for 2009 verified by attending USCG.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 September 2010 Resolved
Found exposed wire splice on bilge pump in port and starboard fwd voids. Install water tight wire connection.
Due 28 September 2010
Resolved 20 September 2010
Lifesaving › Hand Flares › Expired
Issued 14 September 2010 Resolved
Found (01) expired flare. Provide one flare with unexpired date.
Due 28 September 2010
Resolved 27 September 2010
Lifesaving › Lifefloat › Paddle
Issued 14 September 2010 Resolved
Found (05) paddles on (03) life floats not in serviceable conditions. Provide (05) paddles in good conditions.
Due 28 September 2010
Resolved 20 September 2010
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 14 September 2010 Resolved
Found (10) adult life jackets with missing strap metal clips. Provide (10) additional life jackets with working metal clips on straps.
Due 28 September 2010
Resolved 20 September 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 14 September 2010 Resolved
Found (01) B-II fire extinguisher with pressure gauge indication under pressure. Re service the CO2 extinguisher to show pressure gage in green zone.
Due 28 September 2010
Resolved 20 September 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 September 2010 Resolved
Found Engine room Fix fire fighting system (FireBoys) with out service tags. Provide proof of fireBoys system last service.
Due 28 September 2010
Resolved 27 September 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 14 September 2010 Resolved
Found (01) B-I CO2 with out service tag. Provide a proof of CO2 last service.
Due 28 September 2010
Resolved 20 September 2010
Navigation › Piloting/Steering › Magnetic Compass
Issued 14 September 2010 Resolved
Found Compass with inoperable light. Repair compass light.
Due 28 September 2010
Resolved 20 September 2010
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 14 September 2010 Resolved
Found on board 2008 notice to mariners. Provide a proof of current local Notice to Mariners.
Due 28 September 2010
Resolved 20 September 2010
Pollution Prevention/Response › Response Equipment › Non-sparking Portable Pump/Hoses
Issued 14 September 2010 Resolved
Found portable water pump with dhischarge hose to short to reach water side. Provide sufficient hose length to reach out side of the vessel.
Due 28 September 2010
Resolved 20 September 2010
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 14 September 2010 Resolved
Found starboard engine room Bilge high level alarm inoperable. Repair high water level alarm.
Due 28 September 2010
Resolved 20 September 2010
Lifesaving › Lifefloat › Painter
Issued 14 September 2010 Resolved
Found (02) life floats not attached to painter. Attached life floats to the painter.
Due 28 September 2010
Resolved 20 September 2010
Lifesaving › Lifefloat › Float-free Link
Issued 14 September 2010 Resolved
Found (03) life floats with unknown weak link. Install CG approved weak link on the life floats.
Due 28 October 2010
Resolved 8 December 2010
Documentation › Certificates/Documents › FCC SSL
Issued 14 September 2010 Resolved
Found vessel with no FCC Station License. Provide a proof of current FCC Station license.
Due 28 October 2010
Resolved 19 November 2010
Personnel › Training › First Aid/CPR
Issued 14 September 2010 Resolved
Found eyewash solution with expired dates. Provide eyewash solution with current dates.
Due 28 September 2010
Resolved 20 September 2010
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 25 September 2008 Resolved
Install proper fixed fire extinguishing system in port engine room.
Action required: 705 - Other - as specified
Resolved 29 October 2008
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 25 September 2008 Resolved
Install new windows port and starboard bow.
Due 24 October 2008
Resolved 29 October 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 17 September 2007 Resolved
Provide proof of annual service for two B-II fire extinguishers onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 21 September 2007
Resolution: Removed extra unserviced extinguishers.
Lifesaving › Hand Flares › Expired
Issued 17 September 2007 Resolved
Place onboard two orange day smoke signals.
Condition: Improper/Lack of Maintenance
Due 24 September 2007
Resolved 21 September 2007
Resolution: New smoke signals placed onboard.
Documentation › Certificates/Documents › FCC SSL
Issued 17 September 2007 Resolved
Provide proof of a marine raio operator license.
Due 21 December 2007
Resolved 22 February 2008
Resolution: Reviewed radio operator license issued January 16, 2008.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 17 September 2007 Resolved
Make permanent repairs to aft handrail chains and top deck forward chains.
Due 24 September 2007
Resolved 21 September 2007
Resolution: Cable installed.
Lifesaving › Lifebuoys › Serviceable
Issued 17 September 2007 Resolved
Repair or replace one lifebuoy.
Due 24 September 2007
Resolved 21 September 2007
Engineering › Bilge Water Management System › Pump
Issued 17 September 2007 Resolved
Properly mount all bilge pumps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 21 September 2007
Resolution: All pumps properly mounted.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 September 2007 Resolved
Install double hose clamps on main engine exhaust hoses.
Condition: Improper Installation
Due 17 October 2007
Resolved 21 September 2007
Resolution: Double hose clamps installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 27 June 2007 Resolved
Found port and starboard engine room fixed fire fighting system remote activation pulls not connected. Make permenant repairs prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2007
Resolved 28 June 2007
Personnel › Certificates/Documents/Licenses › License, Master
Issued 27 June 2007 Resolved
Found licensed masters knowingly operating M/V Discovery with safety violations with passengers for hire.
Due 27 June 2007
Resolved 27 June 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 May 2007 Resolved
Found the remote fuel shutoffs for port and starboard main engines not connected. Make permenant repairs prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2007
Resolved 28 June 2007
Fire Fighting › Ventilation Systems › Ducts
Issued 7 May 2007 Resolved
Found engine room natural ventilation ducts of an unapproved material. Install proper ventilation ducts as per 46CFR182.465.
Action required: 705 - Other - as specified
Due 27 June 2007
Resolved 31 August 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 May 2007 Resolved
Found plywood insert for opening in forward bulkhead/deck rail not on board the vessel. Replace missing insert.
Action required: 705 - Other - as specified
Due 27 June 2007
Resolved 31 August 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 7 May 2007 Resolved
Found upperdeck not marked with the maximum allowed passengers as per the vessel's stability letter. Mark upperdeck.
Action required: 705 - Other - as specified
Due 27 June 2007
Resolved 7 May 2007
Documentation › Certificates/Documents › Stability Letter
Issued 7 May 2007 Resolved
Found vessel master unable to provide stability letter. Prove stability letter is posted on board vessel.
Action required: 705 - Other - as specified
Due 27 June 2007
Resolved 28 June 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 7 May 2007 Resolved
Found resin smeared across the magnetic compass making it un-readable. Repair compass.
Action required: 705 - Other - as specified
Due 27 June 2007
Resolved 31 August 2007
Engineering › Bilge Water Management System › Hose
Issued 7 May 2007 Resolved
Found unapproved hose used for bilge pump discharge. Replace unapproved hose with approved J-1942 hose.
Action required: 705 - Other - as specified
Due 27 June 2007
Resolved 31 August 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 September 2006 Resolved
Found vessels lifefloats missing lights. Install self activating lights in all lifefloats.
Due 19 September 2006
Resolved 20 September 2006
Engineering › Bilge Water Management System › Pump
Issued 18 September 2006 Resolved
Found vessels starboard aft bilge alarm not properly operating. Prove proper operation of bilge alarm.
Due 18 September 2006
Resolved 19 September 2006
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 September 2006 Resolved
Found Captain not enrolled in company drug test program. Enroll Captain in companies program.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 October 2006
Resolved 24 January 2007
Operations/Management › Pollution › Control of Garbage
Issued 14 September 2006 Resolved
Found vessel did not have a waste management plan. Post waste management plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 14 September 2006
Operations/Management › Drills/Instruction › Fire
Issued 14 September 2006 Resolved
Found vessel not ready of sea which prevented fire drill. Make vessel ready for sea and conduct fire drill.
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 19 September 2006
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 September 2006 Resolved
Found vessel not ready of sea which prevented man overboard drill. Make vessel ready for sea and conduct man overboard drill.
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 19 September 2006
Fire Fighting › Fire Pumps › Arrangement
Issued 14 September 2006 Resolved
Found 5/8 fire pump missing from vessel. Repair or replace fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 18 September 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 September 2006 Resolved
Found fixed halon systems not annually serviced. Prove annual servicing of fixed halon systems.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 19 September 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 September 2006 Resolved
Found vessel missing Coast Guard Light List. Prove vessel has up-dated Coast Guard Light List.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 18 September 2006
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 14 September 2006 Resolved
Found vessel missing inland navigational rules. Prove vessel has up-dated inland navigational rules.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 18 September 2006
Navigation › Piloting/Steering › Marine Charts
Issued 14 September 2006 Resolved
Found vessel missing up-dated marine charts. Prove vessel has up-dated marine charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 20 September 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 September 2006 Resolved
Found vessel missing Tide/Tidal current tables. Prove vessel has up-dated Tide/Tidal current tables.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 18 September 2006
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 September 2006 Resolved
Found vessel missing US Coast Pilot. Prove vessel has up-dated US Coast Pilot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 18 September 2006
Navigation › Piloting/Steering › Magnetic Compass
Issued 14 September 2006 Resolved
Found vessel magnetic compass not illuminated. Prove vessel magnetic compass is illuminated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 18 September 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 September 2006 Resolved
Found stern anchor light obstructed by deck spot light. Prove stern anchor light is not obstructed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 18 September 2006
Deck/Cargo › Mooring/Anchoring › Anchor Cable
Issued 14 September 2006 Resolved
Found vessel did not have adequate length of anchor cable. Prove adequate anchor cable length.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 18 September 2006
Lifesaving › Buoyant Apparatus › Not on Board
Issued 14 September 2006 Resolved
Found all 3 of the vessels buoyant apparatus not ready for inspection. Prove buoyant apparatus are ready for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 20 September 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 September 2006 Resolved
Found remote fuel shutoffs not properly attached. Repair or replace remove fuel shutoffs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 18 September 2006
Fire Fighting › Fixed Steam Fire Extinguishing System › Alarm
Issued 14 September 2006 Resolved
Found fire and smoke detection system not ready for inspection. Prove proper operation of fire and smoke detection system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 18 September 2006
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 14 September 2006 Resolved
Found fuel tanks vent pipe mesh missing. Prove fuel tanks vent pipe have approved mesh.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 18 September 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 14 September 2006 Resolved
Found engine rooms supply ducting not extended to lower bilge. Prove engine rooms supply ducting are extended to lower bilge area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 18 September 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 14 September 2006 Resolved
Found no exhaust ducting in engine rooms. Install exhaust ducting in engine rooms.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 18 September 2006
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 7 July 2006 Resolved
Found vessels starboard engine room fixed fire fighting system not operational. Temporary repairs made on site. Make repairs so activation cable is permanently attached to system.
Due 14 July 2006
Resolved 14 August 2006
Engineering › Gasoline Engine (propulsion) › Rocker Arm, Intake (4 cycle)
Issued 7 July 2006 Resolved
Found temporary repairs made to the vessels throttle cable on the port main engine. Make permanent repairs to throttle cable.
Due 14 July 2006
Resolved 14 August 2006
Operations/Management › Pollution › Control of Garbage
Issued 10 September 2005 Resolved
Found the vessel does not have a written waste management plan. Develop a written waste management plan.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2005
Resolved 4 November 2005
Resolution: Witnessed posting of waste management plan.
Personnel › Training › First Aid/CPR
Issued 10 September 2005 Resolved
Found the vessel does not have 50% of it crew currently trained in CPR/first aid. Complete required training for 50% CPR/first aid.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 November 2005
Resolved 4 November 2005
Resolution: Witnessed current CPR/First aid cards.
Electrical › Electric Supply System (service) › Cable
Issued 10 September 2005 Resolved
Found deadened wires in the overhead main deck and wire not properly connected on the STBD engine room fixed firefighting system. Remove old wiring or replace lighting and properly connect fixed firefighting system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2005
Resolved 4 November 2005
Resolution: Witnessed the removal of dead-end wires.
Documentation › Markings/Placards › Warning Signs
Issued 10 September 2005 Resolved
Found warning signs and safety instruction not properly displayed. Display safety instruction and warning signs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2005
Resolved 4 November 2005
Resolution: Witnessed posting of safety placards.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 10 September 2005 Resolved
Found 3 missing day smokes distress signals. Prove proper day/night distress signals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2005
Resolved 4 November 2005
Resolution: Witnessed newly purchased orange smoke.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 10 September 2005 Resolved
Found children lifejackets missing retro-reflective material. Repair or replace jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2005
Resolved 4 November 2005
Resolution: Witnessed new retro.
Lifesaving › Lifebuoys › Quantity
Issued 10 September 2005 Resolved
Found white lifebuoy in lieu of international orange. Replace white with orange of the proper size.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 September 2006
Resolved 7 July 2006
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 10 September 2005 Resolved
Found Drug and Alcohol program not in compliance with random testing due to small size of company and being self administered. Enroll in Coast Guard approved group DAPI program.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 12 October 2005
Resolved 4 November 2005
Resolution: Witnessed company has enrolled in drug consortium.
Construction/Loadline › Hull › Transverse Frame
Issued 12 April 2005 Resolved
CROP AND RENEW ALL DETERIORATED TRANSVERSE FRAMES AND BULKHEADS.
Condition: Unknown
Due 12 April 2005
Resolved 19 April 2005
Resolution: RECEIVED & APPROVED OWNERS PROPOSAL. REPLACED 4 TRANSVERSE DEEP WEB FRAMES, REPAIRED 4 TRANSVERSE WEB FRAMES AND SISTERED TRANSVERSE WEB FRAMES TO ORIGINAL, ENGINE ROOM BULKHEAD, REPLACED PATCH ON COLLISION BULKHEAD PORT AND STBD PONTOONS.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 November 2004 Resolved
Safety Radio Certificate expired.
Condition: Improper/Lack of Maintenance
Due 9 November 2004
Resolved 18 December 2004
Resolution: Safety Radio certificate issued 12/9/2004.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 9 November 2004 Resolved
Watertight deck hatch seals worn.
Condition: Improper/Lack of Maintenance
Due 9 November 2004
Resolved 9 November 2004
Resolution: Completed
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 9 November 2004 Resolved
Port fixed firefighting system is exhausted. Provide 2 additional CO2 BII Fire Extinguishers. Complete repairs. Provide satisfactory annual servicing report.
Condition: Improper/Lack of Maintenance
Due 1 July 2005
Resolved 4 November 2005
Resolution: Witnessed proper amount and service of extinguishers.
Lifesaving › Lifebuoys › Serviceable
Issued 9 November 2004 Resolved
Lifebuoys missing retroflective tape.
Condition: Improper/Lack of Maintenance
Due 31 January 2005
Resolved 31 January 2005
Resolution: COMPLETED.
Engineering › Bilge Water Management System › Not Operational
Issued 9 November 2004 Resolved
Bilge alarm indicator inoperable.
Condition: Improper/Lack of Maintenance
Due 31 January 2005
Resolved 31 January 2005
Resolution: COMPLETED.
Documentation › Certificates/Documents
Issued 20 May 2003 Resolved
FCC Safety Certificate not present in non-adherence with 47 CFR 80. Corrective action required not later than 20 June 03. LEGACY COMPONENT DESC: FCC Safety Certificate
Condition: Improper/Lack of Maintenance
Due 20 June 2003
Resolved 10 September 2003
Lifesaving
Issued 20 May 2003 Resolved
Vessels 3 LF/BA not properly stowed in non-adherence with 46 CFR 180.130/.137. Not later than 05 June 03 LF/BA shall be stowed in a float free condition with weak link.
Due 5 June 2003
Resolved 5 June 2003
Lifesaving
Issued 20 May 2003 Resolved
Vessel's 3 LF/BA missing equipment in non-adherence with 46 CFR 180.175. Not later than 05 June 03 corrective action shall be taken, eg each raft shall have appropriate paddles, water lights, painters, and grab lines.
Due 5 June 2003
Resolved 5 June 2003
Lifesaving
Issued 20 May 2003 Resolved
Vessel's 3 LF/BA retro-reflective tape deteriorated in non-adherence with 46 CFR 185.604. Not later than 05 June 03 appropriate retro-reflective tape shall be installed.
Due 5 June 2003
Resolved 10 September 2003
Lifesaving
Issued 20 May 2003 Resolved
Vessel lifejackets [personal flotation devices] retro-reflective tape deteriorated in non-adherence with 46 CFR 185.604. Not later than 05 June 03, proper retro-reflective tape shall be installed.
Due 5 June 2003
Resolved 10 September 2003
Lifesaving
Issued 20 May 2003 Resolved
Ring life bouys deteriorated in non-adherence with 46 CFR 180.70. Not later than 05 June 03, ring bouys shall be replaced or be refurbished in accordance with manufacturer's instructions to original subchapter Q specification.
Due 5 June 2003
Resolved 5 June 2003
Lifesaving
Issued 20 May 2003 Resolved
CAT 1, 406 EPIRB battery expired in non-adherence with 46 CFR 185.728. Not later than 05 June 03 battery shall be replaced.
Due 5 June 2003
Resolved 5 June 2003
Resolution: Owner has ordered new unit per invoice w/evidence of down payment presented at time of deficiency check.
Accommodation/Occupational Safety › Occupational Safety
Issued 20 May 2003 Resolved
Emergency Instruction List not posted in a manner visible to passengers in non-adherence with 46 CFR 185.510. Not later than 05 June 03 Instruction List shall be posted. LEGACY COMPONENT DESC: Emergency Instruction List
Due 5 June 2003
Resolved 5 June 2003
Operations/Management
Issued 20 May 2003 Resolved
Man Overboard Drills not logged in non-adherence with 46 CFR 185.520. Not later than 05 June 03 Man Overboard Drills shall be logged.
Due 5 June 2003
Resolved 5 June 2003
Operations/Management
Issued 20 May 2003 Resolved
Fire Fighting Drills not logged in non-adherence with 46 CFR 185.524. Not later than 05 June 03 Fire Fighting Drills shall be logged.
Due 5 June 2003
Resolved 5 June 2003
Operations/Management
Issued 20 May 2003 Resolved
Monthly EPIRB test not logged in non-adherence with 46 CFR 185.728. Not later than 05 June 03 monthly EPIRB test shall be logged.
Due 5 June 2003
Resolved 20 May 2003
Operations/Management
Issued 20 May 2003 Resolved
Survival craft maintenance not logged in non-adherence with 46 CFR 185.702. Not later than 05 June 03 survival craft maintenance shall be logged.
Due 5 June 2003
Resolved 5 June 2003
Accommodation/Occupational Safety
Issued 20 May 2003 Resolved
First aid kit not maintained in non-adherence with 46 CFR 184.710. Not later than 05 June 03 first aid kit shall be replaced or refurbished.
Due 5 June 2003
Resolved 5 June 2003
Navigation
Issued 20 May 2003 Resolved
Nautical charts and publications not corrected to date in non-adherence with 46 CFR 184.420. Not later than 05 June 03 charts and publications required to be corrected to date using Notices to Mariners Corrections.
Due 5 June 2003
Resolved 5 June 2003
Engineering
Issued 20 May 2003 Resolved
Starboard emergency fuel shut off inoperable in non-adherence with 46 CFR 185.608. Not later than 05 June 03 remote shut off shall be re-engineered to ensure proper valve closure.
Due 5 June 2003
Resolved 5 June 2003
Construction/Loadline
Issued 20 May 2003 Resolved
Deck IWO starboard side midships outer hull deteriorated. Note: Item on owner's worklist to be completed not later than 15 July 2003. Owner notified USCG of deficiency.
Due 15 July 2003
Resolved 2 July 2003
Fire Fighting
Issued 20 May 2003 Resolved
Starboard engine compartment fixed fire extinguishing system cable is stiff. Note: Item on owner's worklist to be completed not later than 15 July 2003. Owner notified USCG of deficiency.
Due 15 July 2003
Resolved 10 September 2003
Lifesaving
Issued 13 February 2001 Resolved
Provide proof of EPIRB registration with NOAA.
Condition: Unknown
Due 13 February 2001
Resolved 13 February 2001
Construction/Loadline
Issued 7 September 2000 Resolved
Prove the operation of the bilge pumps in the port and stbd fwd compartment, and the stbd water tank compartment.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Construction/Loadline
Issued 7 September 2000 Resolved
Prove the operation of the port and stbd engine room high level bilge alarms.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Accommodation/Occupational Safety
Issued 7 September 2000 Resolved
Stencil upper deck capacity in way of aft ladder.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Accommodation/Occupational Safety
Issued 7 September 2000 Resolved
Install upper course rail in way of the forward port and stbd passenger embarkation point.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Accommodation/Occupational Safety
Issued 7 September 2000 Resolved
Install lower course rail in way of the aft port and stbd passenger embarkation point.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Lifesaving
Issued 7 September 2000 Resolved
Provide 3 hand held flares.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Lifesaving
Issued 7 September 2000 Resolved
Provide waterlights and paddles for each life float and mount in a float free arrangement with painter. Vessel is restricted to not more than three(3) miles from shore until completion.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Lifesaving
Issued 7 September 2000 Resolved
Renew grab lines on the main deck ring buoy.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Engineering
Issued 7 September 2000 Resolved
Install heat shield/lagging over turbo chargers on the port and stbd engines.x
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Unknown
Issued 7 September 2000 Resolved
Present company drug testing program for review by USCG marine inspector.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Lifesaving
Issued 7 September 2000 Resolved
Renew the hydrostatic release device for the EPIRB and register EPIRB with NOAA. Vessel is restricted to not more than three (3) miles from shore until completion.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Lifesaving
Issued 7 September 2000 Resolved
Provide 1 additional adult life jacket for the vessel.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Navigation
Issued 7 September 2000 Resolved
Update chart 81076 and provide tide and current tables.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Lifesaving
Issued 7 September 2000 Resolved
Provide sufficient amounts of USCG approved life floats for 24 persons or conver the onboard buoyant apparatuses in accordance with manufactures instructions. Vessel is restricted to not more than three (3) miles from shore until completion.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Construction/Loadline
Issued 27 October 1999 Resolved
Make watertight the forward and middle compartment flush deck hatches on the port and starboard sides.
Condition: Unknown
Due 27 October 1999
Resolved 27 October 1999
Construction/Loadline
Issued 8 September 1999 Resolved
Renew/repair all deck to hull interior bonding angle on the 3rd compartmentfrom the bow on the starboard side.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Construction/Loadline
Issued 8 September 1999 Resolved
Double clamp all electric bilge pump discharge hoses.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Construction/Loadline
Issued 8 September 1999 Resolved
Cap the thru-hull fitting for the former fire pump sea suction prior to operation with passengers.
Condition: Unknown
Due 9 September 1999
Resolved 10 September 1999
Engineering
Issued 8 September 1999 Resolved
Double hose clamp all salt water cooling inlet hoses.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Electrical
Issued 8 September 1999 Resolved
Install a battery cover for the starboard battery bank.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Construction/Loadline
Issued 8 September 1999 Resolved
Stencil vessel's name and hailing port on the stern.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Construction/Loadline
Issued 8 September 1999 Resolved
Stencil upper deck limitation on the vessel.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Construction/Loadline
Issued 8 September 1999 Resolved
Install high level bilge alarms for the port and starboard steering compartments.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Documentation
Issued 8 September 1999 Resolved
Post original COI on vessel.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Navigation
Issued 8 September 1999 Resolved
Provide an 8 inch bell for the vessel.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Lifesaving
Issued 8 September 1999 Resolved
Provide a watertight container for the distress signals and label.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Fire Fighting
Issued 8 September 1999 Resolved
Prove the operation of the alarms and safeties for the pre-engineered fixedfire fighting systems.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Navigation
Issued 8 September 1999 Resolved
Install cotter pins on the hardware connecting the tie bar to both steeringtiller arms prior to operations with passengers.
Condition: Unknown
Due 9 September 1999
Resolved 10 September 1999
Navigation
Issued 8 September 1999 Resolved
Provide a copy of the Navigation Rules for the vessel.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Lifesaving
Issued 8 September 1999 Resolved
Provide 3 additional flares for the vessel.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Construction/Loadline
Issued 8 September 1999 Resolved
Provide sufficient discharge hose for the portable bilge pump to remove water from any compartment directly overboard.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Engineering
Issued 8 September 1999 Resolved
Install lagging on the inlet elbow to the turbo charger from the exhaust manifold for both engines.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Unknown
Issued 8 September 1999 Resolved
Provide training to all masters and deckhands on the company's drug and alcohol program no later than 16SEP99.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Lifesaving
Issued 8 September 1999 Resolved
Log and conduct quarterly emergency drills (fire and man overboard drills).
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Lifesaving
Issued 8 September 1999 Resolved
Conduct and log monthly EPIRB tests.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Lifesaving
Issued 8 September 1999 Resolved
Mount EPIRB in a float free arrangement.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Unknown
Issued 20 July 1999 Resolved
Properly install bottom holder platform brackets and backing plates for thetop hinge supports and compressor foundations to the satisfaction of the attending USCG marine inspector. Until such time, no more than 4 dive helmets and 2 personnel may be on the dive platform at one time.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Engineering
Issued 8 September 1998 Resolved
Repair fuel shut-off valve system.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Navigation
Issued 8 September 1998 Resolved
Replace compass lightbulb. Until such time, vsl is limited to daylight operations only.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Unknown
Issued 8 September 1998 Resolved
Battery box does not allow for proper ventilation. Replace or repair current battery box in port/stbd ER.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Electrical
Issued 8 September 1998 Resolved
Repair/replace engine on/off switch.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Lifesaving
Issued 8 September 1998 Resolved
Provide a corrosion resistant detachable clip for floating waterlight/ring life buoy, as per 46 CFR 180.70.d.3.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Fire Fighting
Issued 8 September 1998 Resolved
Replace portable BII extinguisher outside stbd ER.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Engineering
Issued 8 September 1998 Resolved
Install approved fuel line.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Electrical
Issued 8 September 1998 Resolved
Replace ground wire for fill pipe/fuel tank.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Engineering
Issued 8 September 1998 Resolved
Repair fuel tank vents and install a single screen of corrosion resistant wire of at least 30X30 mesh.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Engineering
Issued 8 September 1998 Resolved
Repair ER ventilation system. As currently installed, both power ventilation units provide supply ventilation (one of the two units needs toprovide exhaust ventilation).
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Fire Fighting
Issued 7 September 1997 Resolved
Provide and install a fixed fire extinguishing and detecting system in the engine room in accordance with 46 CFR 400.
Condition: Unknown
Due 7 September 1997
Resolved 7 September 1997

Casualty record · 2

29 July 2012Routine · role: Involved in a Marine Casualty · activity 4402114
11 September 2012Routine · role: Subject to Marine Inspection · activity 4454135
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.