Records from 1985 to 1992. Most recent: inspection, 21 October 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
21 October 1992
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 651393
11 October 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261262
10 October 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 142738
18 May 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 948770
10 April 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 949481
7 November 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246443
18 September 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1250127
12 April 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1250279
26 November 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219407
6 April 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 917335
5 December 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1215999
1 November 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340532
10 August 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1033858
15 April 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1032060
13 March 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1338832
18 March 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351763
2 February 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1324947
4 March 1987
Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030060
17 November 1986
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1320475
17 April 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309486
9 April 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309482
25 February 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 978008
Documentation
Issued 7 November 1991
Resolved
RENEW FCC LICENSE.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Construction/Loadline
Issued 26 November 1990
Resolved
FALSE KEEL AND SEVERAL TRANS BOTTOM PLANKS REPLACED ALL NEW KEEL BOLTS INSTALLED. NEW WORN SHOE INSTALLED.
Condition: Unknown
Due 26 November 1990
Resolved 26 November 1990
Lifesaving
Issued 10 August 1989
Resolved
PROCURE AND PLACE ON BOARD ONE COAST GUARD APPROVED LIFE RING BUOY TO BE USED AS SUBSTITUTE AS PRIMARY LIFESAVING EQUIPMENT AS PER 46 CFR 180.10-30 (D). UNTIL THIS IS COMPLETED TO THE SATISFACTION OF [name withheld] VESSEL ISRESTRICTED TO 42 PASSENGERS.
Condition: Unknown
Due 10 August 1989
Resolved 10 August 1989
Lifesaving
Issued 4 March 1987
Resolved
PROVIDE 8 ADULT AND 2 CHILDREN'S LIFE PRESERVERS.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Lifesaving
Issued 4 March 1987
Resolved
PROVIDE PAINTER AND WEAK LINK FOR BUOYANT APPARATUS.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Navigation
Issued 4 March 1987
Resolved
PROVIDE 10 POINT STERN LIGHT IN ACCORDANCE WITH INTERNATIONAL RULES OF THE ROAD.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Fire Fighting
Issued 4 March 1987
Resolved
PROVIDE HAND FIRE PUMP WITH SUCTION AND DISCHARGE.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Construction/Loadline
Issued 9 April 1986
Resolved
RENEW TWO STIFFENERS IN TRANSOM, PORT SIDE COUNTING OUT BOARD FROM KEEL.
Condition: Unknown
Due 9 April 1986
Resolved 9 April 1986
Engineering
Issued 9 April 1986
Resolved
PROVIDE SUPPORT BRACKETS FOR BILGE PIPING.
Condition: Unknown
Due 9 April 1986
Resolved 9 April 1986
Accommodation/Occupational Safety
Issued 9 April 1986
Resolved
CONNECT PIPE FROM HEAD DIRECTLY TO HOLDING TANK.
Condition: Unknown
Due 9 April 1986
Resolved 9 April 1986
Construction/Loadline
Issued 9 April 1986
Resolved
RENEW FRAMES 7 & 8 ON PORT SIDE MACHINERY SPACE.
Condition: Unknown
Due 9 April 1986
Resolved 9 April 1986
Engineering
Issued 9 April 1986
Resolved
REPLACE FOUR (4) VENT DUCTS IN MACHINERY SPACE WITH VENTS WHICH ARE RIGID AND PERMANENTLY INSTALLED AND OF FIRE PROOF CONSTRUCTION.
Condition: Unknown
Due 9 April 1986
Resolved 9 April 1986