Records from 2016 to 2022. Most recent: inspection, 11 March 2022.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 October 2021
Resolved
[name withheld] suffered potential damage to hull or propulsion system after collison with a bouy. Vessel to be hauled out for further inspection, prior to carrying passengers IAW 46CFR176.840.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2021
Resolution: Prop replaced, sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 July 2021
Resolved
Water ingress in fore peak portside stem approx 02 ft from keel. Water ingress in tank room port-side aft approx third plank from keep.
Repairs must be made prior to carrying passengers after 26JUL21.
All permantent repairs performed to satisifaction of attending [name withheld] 46CFR176.15-5.
Action required: 705 - Other - as specified
Resolved 31 July 2021
Resolution: Replaced wasted plank
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 July 2021
Resolved
Install approved retro material on life ring. IAW 46CFR180.30-1.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2021
Resolved 29 July 2021
Resolution: Approved retro applied to life ring.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 July 2021
Resolved
MI noted several areas of water ingress, fore peak, tank room port side, and rudder shaft packing. Vessel crew is required to conduct hourly rounds to evaluate water level, and ingress rate, and conduct drydock exam IAW 46CFR176.15-5.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 26 July 2021
Resolution: Repairs made were not satisfactory. Marine Inspectors issued a new CG-835 during the def. check.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 July 2021
Resolved
Port aft rail rot, make proper repairs IAW 176.15-5.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 26 July 2021
Resolution: Railing was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 July 2021
Resolved
Main engine sea valve seized in open position, ensure proper operations IAW 176.15-5.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 26 July 2021
Resolution: Valves were repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 July 2021
Resolved
Excessive debris in fuel filters, replace filters/clean and clean fuel tanks IAW 46CFR182.20-25.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 26 July 2021
Resolution: fuel filters were replaced. Vessel performed fuel exchange.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 13 July 2021
Resolved
Epirb hydrostatic release found expired. Install new release or remove EPIRB from vessel since not required IAW 46CFR180.64.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2021
Resolved 26 July 2021
Resolution: Epirb was removed from the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2021
Resolved
Properly label life jacket storage IAW 46CFR185.604(f).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2021
Resolved 26 July 2021
Resolution: New life ring placed in service was not outfitted w/ Coast Guard Approved retroreflective material. New deficiency issued during follow-up inspection on 26JUL21.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 July 2021
Resolved
Properly label bilge suction to ensure proper alignment IAW 46 CFR 182.25-5.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2021
Resolved 26 July 2021
Resolution: bilge system properly labeled.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 July 2021
Resolved
Install proper ventilation closures for engine room vents, repair or replace existing slides/brackets. IAW 46CFR182.460(k)(1).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 26 July 2021
Resolution: vessel crew fabricated new vent covers and placed in service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 July 2021
Resolved
Life ring buoy is begining to fade and is not expected to be servicable at next annual inspection. Install new life ring IAW 46CFR180.30-1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2021
Resolved 26 July 2021
Resolution: The new life ring installed on the stern of the vessel was not outfitted with Coast Guard Approved retroreflective material. New deficiency issued during the follow up inspection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 July 2021
Resolved
Ensure all battery covers are properly installed IAW 46CFR111.15-1(c)(2).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 26 July 2021
Resolution: battery covers installed properly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 July 2021
Resolved
Clean corrosion from STBD Aft Battery IAW 46CFR111.05-15(c).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2021
Resolved 26 July 2021
Resolution: corrosion cleaned off battery
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 13 July 2021
Resolved
Install rotating machinery guard over shaft in engine room iaw 46 CFR 177.35-15.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2021
Resolved 26 July 2021
Resolution: guard installed over shaft.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 8 July 2019
Resolved
COD was not available on vessel/posted on vessel. Post valid COD on vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 7 August 2019
Resolution: Vessel made COD available for Inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 July 2019
Resolved
Vessel did not have stability letter on board/posted on vessel. Post stability letter on vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 7 August 2019
Resolution: Vessel posted stability letter.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 8 July 2019
Resolved
Vessel master did not have FCC radio operator permit on board. Vessel is restricted to 1000 feet from shore unless someone on board possess' a valid FCC marine radio operators permit. 47 CFR 80.903
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 7 August 2019
Resolution: Master provided valid FCC MROP.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 8 July 2019
Resolved
MSD overboard discharge valve was found open. Vessel master closed valve and removed handle. Remove overboard discharge line and cap since vessels new route was reduced to less than 3 NM from shore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 7 August 2019
Resolution: Vessel capped overboard discharge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2019
Resolved
Vessel did not have lifejacket donning instructions posted for Model 199 lifejacket. Outfit vessel with all types of lifejacket donning instructions carried on board.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 7 August 2019
Resolution: Vessel posted additional donning instructions
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 July 2019
Resolved
Cable hanging from over head in forward hold space. Make repair to cable support.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 7 August 2019
Resolution: Vessel installed cable supports.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 July 2019
Resolved
Found a 1/2" diameter bulkhead penetration on the port side of the aft forward hold space watertight bulkhead (#2 bulkhead). Make penetration watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 7 August 2019
Resolution: Vessel sealed bulkhead penetration with sealant.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 July 2018
Resolved
Found old call sign on EPIRB registration. Update registration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 28 August 2018
Resolution: Updated registration
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 July 2018
Resolved
Found hydrostatic release expired on the EPIRB. Replace hydrostatic release.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 28 August 2018
Resolution: Installed new release
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 July 2018
Resolved
Found navigation charts outdated replace charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 28 August 2018
Resolution: Purchased new charts
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 July 2018
Resolved
Found three deck hatches missing lanyards. Install lanyards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 28 August 2018
Resolution: Installed lanyards
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 July 2018
Resolved
Found permanently installed extension cord. Remove extension cord.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 28 August 2018
Resolution: Extension cord is only for refrigerator use while in port and is no longer permanently installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 July 2018
Resolved
Found installed bilge manifold valve seized. Repair/ replace valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 28 August 2018
Resolution: Valve has been renewed; test sat.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 2 July 2018
Resolved
Found engine room fire dampers missing. Provide fire dampers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 28 August 2018
Resolution: New dampers have been placed on board
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 July 2018
Resolved
Found reach rod for the for peak bilge valve does not penetrate the main deck. Extend reach rod or secure valve and remove handle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 28 August 2018
Resolution: Valve has been secured and the handle removed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 July 2018
Resolved
Found multiple items missing from the first aid kit. Provide missing items.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 28 August 2018
Resolution: Missing items have been purchased.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 July 2018
Resolved
Found cracked steering shaft support block in the lazzerette. Replace block.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 28 August 2018
Resolution: Block has been repaired.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 May 2017
Resolved
Found original COD missing. keep original COD on board vessel.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 6 July 2017
Resolution: Original COD placed aboard vessel.
Documentation › Certificates/Documents › FCC SSL
Issued 17 May 2017
Resolved
Found FCC station license missing. Keep station license on board vessel.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 6 July 2017
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 May 2017
Resolved
Found FCC safety radio certificate expired. vessel restricted to not more than 1,000 feet from shore until certificate has been renewed.
Action required: 705 - Other - as specified
Resolved 6 July 2017
Resolution: Safety Radio Certificate renewed.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 17 May 2017
Resolved
Found DAPI proof of enrollment not available. Provide proof of enrollment.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 6 July 2017
Resolution: Proof of current DAPI enrollment provided
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 17 May 2017
Resolved
Found tide tables and tidal currents missing. Provide tide and current tables.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 6 July 2017
Resolution: Procured tide and current tables.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 17 May 2017
Resolved
Found EPIRB registration missing. Maintain registration on board vessel.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 6 July 2017
Resolution: Provided proof of EPIRB registration renewal.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 May 2017
Resolved
Found portable and fixed fire servicing completed but missing the certificate. Maintain servicing certificate on board vessel.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 6 July 2017
Resolution: Provided proof of fire servicing.
Documentation › Certificates/Documents › FCC SSL
Issued 21 April 2016
Resolved
License expired. Replace IAW 47 CFR 80.13. Limited to not more than 1000 feet from shore until new license is obtained.
Action required: 705 - Other - as specified
Resolved 11 May 2016
Resolution: Required license was presented.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 April 2016
Resolved
Navigation publications outdated. Replace tide charts, lightlist and coast pilot.
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 May 2016
Resolution: Nav Pubs, tide charts, lightlist and coast pilot was presented as required.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 April 2016
Resolved
Contents of first aid kit expired.
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 May 2016
Resolution: First Aid kit was replaced.
Lifesaving › Lifefloat › Serviceable
Issued 21 April 2016
Resolved
Life floats require new paint.
Action required: 705 - Other - as specified
Resolved 11 May 2016
Resolution: Life Floats were painted with approved paint as required.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 April 2016
Resolved
Life float attached to port life float has paint obstructing bulb. Remove paint as necesary.
Action required: 705 - Other - as specified
Resolved 11 May 2016
Resolution: The paint on the port life float was cleaned off as required.
Lifesaving › Lifefloat › Painter
Issued 21 April 2016
Resolved
Port side life float painter line needs to be replaced.
Action required: 705 - Other - as specified
Resolved 11 May 2016
Resolution: Port side life float painter was replaced as required.
Lifesaving › Lifefloat › Painter
Issued 21 April 2016
Resolved
Painter line retainer must be affixed to the deck.
Action required: 705 - Other - as specified
Resolved 11 May 2016
Resolution: The life float painter line retainer was affixed to the deck as required.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 April 2016
Resolved
Life ring buoy requires vessel name.
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 May 2016
Resolution: Vessel's name was placed on life ring buoy as required.
Fire Fighting › Nozzles › Type
Issued 21 April 2016
Resolved
Garden hose nozzle is required to be bronze or equivalent metal.
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 May 2016
Resolution: Garden hose nozzle was replaced with a proper one.