FALCON

FALCON is a 1997 offshore supply vessel. The Coast Guard has recorded 45 inspections since 1997, most recently in April 2026, along with 57 deficiencies, 1 operational control and 1 casualty investigation in 2013.

Records from 1997 to 2026. Most recent: inspection, 8 April 2026.

Built
1997
Last inspected
8 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8964769 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDK7693
458797
Flag
UNITED STATES
368086880
Maury page id
psix-458797

Inspections, by type

…with no type recorded8
Years with a record 23 calendar years (1997–2026)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)129.5 ft × 36.0 ft × 12.0 ft
Registered tonnagegross 92 / net 62
ITC dimensions (L × B × D)129.5 ft × 36.0 ft × 12.0 ft
ITC tonnagegross 440 / net 132
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 1997
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLAROSE, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it440 - Convention (Subpart B), Gross Ton
92 - Regulatory (Subpart C or D), Gross Ton
132 - Convention (Subpart B), Net Ton
62 - Regulatory (Subpart C or D), Net Ton
355 - Dead Weight, Ton
783 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK7693MMSI 368086880 · active · compulsorily equipped · granted 11 April 2019, expires 11 April 2029
WDG8090MMSI 367573910 · expired · compulsorily equipped · granted 9 May 2013, cancelled 15 July 2023
WDE2459MMSI 367325550 · expired · compulsorily equipped · granted 5 December 2007, cancelled 10 February 2018 · licensed under a name not among this hull’s recorded names (not shown)
WCX8669MMSI 366741670 · expired · compulsorily equipped · granted 3 December 1997, cancelled 2 February 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 45

8 April 2026 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8344838
23 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8165112
14 March 2024 Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7879368
6 March 2024 Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7875308
28 June 2023 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7724853
14 June 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7476975
6 April 2021 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7169441
15 March 2021 Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7156554
2 July 2019 Hull Examination · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6733050
21 June 2016 MTSA Verification · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5914716
13 May 2016 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5878942
6 May 2016 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5914643
13 August 2015 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5215693
27 July 2015 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5208224
27 July 2015 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5211972
22 August 2014 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4961324
26 March 2010 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3703283
21 November 2008 Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3361855
28 November 2007 Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3106107
16 April 2007 Internal Structural Exam · Cargo Tank Internal · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2920450
11 January 2007 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2854010
30 August 2006 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2763765
9 November 2005 Re-Inspection · MTSA Verification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2531117
12 July 2005 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2424033
28 June 2005 MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2406484
28 June 2005 Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2406514
29 June 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2114750
28 October 2003 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1937506
28 May 2002 Hull Examination · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1613184
30 August 2001 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1412349
20 October 2000 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421935
29 April 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 196939
29 April 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 754104
2 March 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1047005
24 February 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046626
31 January 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1045470
25 January 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 814874
22 December 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 814818
5 October 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453667
13 June 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 666057
28 March 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 196936
11 December 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395073
19 November 1997 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 762803
2 November 1997 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 196938
5 October 1997 Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1372026

Deficiency record · 57

10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 23 June 2025 Resolved
Vessel must carry adequate and up-to date charts. Vessel utilizes electronics charts via Rose Point Coastal Explorer, which is not approved for commercial use. The charts on board were also not up to date (last DEC24). If vessel wants to continue to use Rose Point, it must get Rose Point ECS. 46 CFR 130.330
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2025
Resolved 24 June 2025
Resolution: Rose Point ECS was installed on the vessel and verified up to date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2025 Resolved
Nothing in this subpart limits the marine inspector from making tests or inspections deemed necessary to be assured of the vessel's seaworthiness. The local RPM gauge on the port MDE was inoperable. 46CFR 126.510(a)(4)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2025
Resolved 26 June 2025
Resolution: A new RPM gauge for the port MDE was purchased and installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 April 2021 Resolved
A Class-1 door may be installed at any place if the vessel's pilothouse contains a visual indicator showing whether the door is open or closed; Indicator for forward door "open" alarm was inoperable.
Action required: 10 - Deficiency Rectified
Resolved 7 April 2021
Resolution: Vessel affected repairs by the end of the inspection and demonstrated operability of watertight door indicator alarm for forward door.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2021 Resolved
Battery installations must be protected from falling objects and well ventilated; Battery boxes on the bridge wing were filled with debris.
Action required: 10 - Deficiency Rectified
Resolved 7 April 2021
Resolution: Battery boxes were cleaned out by the end of the inspection.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 21 June 2016 Resolved
During in-service MTSA examination, found vessel unattended, with machinery running. Inspectors gained access to all areas of vessel. Provide proper manning on board in accordance with Vessel Security Plan and Certificate of Inspection in accordance with 46 CFR 131.920.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2017
Resolved 20 March 2017
Resolution: Company bankrupt and no longer owns vessel.
Electrical › Electric Generation Source (emergency) › Generator
Issued 13 May 2016 Resolved
Provide proper operation of generators and emergency power prior to sail
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2016
Resolution: CG MI re-attended the vessel and witnessed satisfactory operation of generators and emergency power.
Stability › Watertight Integrity › General
Issued 13 May 2016 Resolved
Provide proper operation of water tight doors indicator in the pilot house prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2016
Resolution: CG MI attended vessel and witnessed satisfactory operation of water tight door indicator
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 13 May 2016 Resolved
Provide proper operation of steering angle indicator 35-30 port to stbd.
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 1 June 2016
Resolution: Received confirmation from vessel rep that the indicator is capable of showing 28-24 with the rudder hard over, vessel rep was notified to have the indicator calibrated to show 35-30 at next annual inspection.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 13 May 2016 Resolved
Repair leak at diesel fuel oil transfer meter prior to conducting fuel oil transfer.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2016
Resolution: CG MI attended vessel and verified proper repair.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 May 2016 Resolved
Provide guard to liquid mud pump shaft.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 18 May 2016
Resolution: CG MI attended the vessel and verified guard was installed.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 May 2016 Resolved
Repair leak on port MDE exhaust.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 1 June 2016
Resolution: Received confirmation from vessel rep that repairs was completed.
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 13 May 2016 Resolved
Provide satisfactory class surveyed for loadline prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2016
Resolution: Talked with ABS Surveyor [name withheld], and verified that vessel's loadline certificate was endorsed by the attending surveyor.
Navigation › Piloting/Steering › Marine Charts
Issued 13 August 2015 Resolved
Update paper charts. (Prior to sail)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2015
Resolution: Vessel received updated charts.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 August 2015 Resolved
Repair anchor light to operation.
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 20 August 2015
Resolution: Vessel repaired anchor light to operation.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 13 August 2015 Resolved
Repair opening in electrical panel on bridge.
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 20 August 2015
Resolution: Vessel put a cover over the opening in electrical panel on the bridge.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 13 August 2015 Resolved
Remove extension cord from bridge. (Prior to sail)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2015
Resolution: Vessel made extension cord a permanent fixture on the vessel.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 13 August 2015 Resolved
Repair rudder angle indicators.
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 4 September 2015
Resolution: Rudder angle indicator was repaired.
Lifesaving › Lifefloat › Lifeline
Issued 13 August 2015 Resolved
Fasten line of life float around body and make line 18 ft. long. (Prior to sail)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2015
Resolution: Vessel fastened line of life float around the body and made the line 18ft long.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 August 2015 Resolved
Fasten line of life ring around body and make line 3-6ft long. (Prior to sail)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2015
Resolution: Vessel fastened line of life ring around body and made line 3-6ft long.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 August 2015 Resolved
Replace expired alcohol test strips. (Prior to sail)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2015
Resolution: Vessel replaced expired alcohol test strips.
Fire Fighting › Fire Main › Condition
Issued 13 August 2015 Resolved
Repair leaking fire monitor.
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 20 August 2015
Resolution: Vessel repaired leaking fire monitor by replacing the packing.
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 August 2015 Resolved
Repair leaking water expansion tank pipe.
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 20 August 2015
Resolution: Vessel repaired leaking water expansion tank pipe by replacing the pipe.
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 13 August 2015 Resolved
Repair port MDE emergency shutdown to operation. (Prior to sail)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2015
Resolution: Vessel repaired port MDE emergency shutdown to operation.
Construction/Loadline › Structures › Machinery Space Opening
Issued 13 August 2015 Resolved
Repair 2 watertight doors in engine room to watertight integrity. (Prior to sail)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2015
Resolution: Vessel repaired 2 watertight doors in the engine room to watertight integrity.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 August 2015 Resolved
Repair emergency lighting for adequate evacuation. (Prior to sail)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2015
Resolution: Vessel replaced week battery and dull light bulbs which made emergency lighting adequate for evacuation.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 13 August 2015 Resolved
Conduct MOB drill to the satisfaction of the attending CG Marine inspector. (Prior to sail)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2015
Resolution: Vessel conducted MOB to the satisfaction of the attending CG Marine Inspector.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 27 July 2015 Resolved
Dirty oil piping in engine room does not match the drawings for the system. Questionable section has been removed. Repair and replace IAW approved drawings to be verified at next annual inspection scheduled 13AUG2015.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 August 2015
Resolved 13 August 2015
Resolution: Piping was removed so that dirty oil piping did not connect overboard.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 22 August 2014 Resolved
Ballast pump used as emergency fire pump did not provide proper pressure for fire fighting
Due 22 September 2014
Resolved 25 August 2014
Resolution: Pump produced 75 p.s.i. w/two hoses
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 August 2014 Resolved
Found diesel fuel leaking from hose directly into bilge. Bilge had accumulation of diesel in bilge
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2014
Resolution: Diesel fuel removed and bilge cleaned
Lifesaving › Line-Throwing Appliances › Lines
Issued 22 August 2014 Resolved
No auxiliary line on board for Line-throwing gun
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2014
Resolution: Auxiliary line provided as required
Operations/Management › Drills/Instruction › Fire
Issued 22 August 2014 Resolved
Conducted fire drill in galley. Crew communication was non-existent. Master was getting no information from crew during drill
Action required: 705 - Other - as specified
Resolved 25 August 2014
Resolution: CG inspector witnessed satisfactory fire drill
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 August 2014 Resolved
Witnessed MOB Drill. Pointer and master never notified other crewmembers of MOB. Stopped drill
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2014
Resolution: CG Inspector witnessed satisfactory drill
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 22 August 2014 Resolved
Vessel did not have proper number of day shapes on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2014
Resolution: CG Inspector verified proper number of day shapes on board
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 22 August 2014 Resolved
Mate had no FCC License
Due 22 September 2014
Resolved 25 August 2014
Resolution: Mate presented new FCC License
Operations/Management › Pollution › Control of Garbage
Issued 22 August 2014 Resolved
Vessel had no MARPOL Annex V placards on board
Due 22 September 2014
Resolved 25 August 2014
Resolution: New MARPOL placards on board
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 22 August 2014 Resolved
Bilge alarm light not operating. When bilge alarm was tested a general audible alarm sounded which did not show location from which the alarm was sounding
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2014
Resolution: Alarm light and audible alarms working properly and showing location of alarm
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 22 August 2014 Resolved
Provide updated EAP phone list. Phone list contained out of service numbers
Due 22 September 2014
Resolved 25 August 2014
Resolution: New EAP phone list provided
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 22 August 2014 Resolved
No CG 2692B forms on board or available for alcohol test reporting
Due 22 September 2014
Resolved 25 August 2014
Resolution: CG 2692B on board
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 August 2014 Resolved
Reduction gear cooling water hose leaking
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2014
Resolution: Reduction gear cooling water hose replaced
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 30 August 2006 Resolved
Provide 2006 tide tables.
Condition: Improper/Lack of Maintenance
Due 13 September 2006
Resolved 30 August 2006
Resolution: Provided.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 30 August 2006 Resolved
Complete ABS loadline survey prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2006
Resolution: ABS provided new loadline certificate and verified position of new marks.
Documentation › Certificates/Documents › Stability Letter
Issued 30 August 2006 Resolved
Provide new stability letter based on incline experiment. Vsl was operating on expired special voyage permit issued by ABS.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2006
Resolution: ACO submitted stability study and additional calculations based on vsl operations. ABS issued new stability ltr and new loadline assignment.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 30 August 2006 Resolved
Install shaft tachometers within 3 months
Condition: Improper Installation
Due 30 November 2006
Resolved 16 November 2007
Resolution: Verified operable tachs were installed.
Engineering › Diesel Engine (auxiliary) › Nozzle, Injection (fuel injection)
Issued 30 August 2006 Resolved
Provide clamp for fuel delivery lines to injectors, in accordance with manufacturer's instructions.
Condition: Improper/Lack of Maintenance
Due 13 September 2006
Resolved 31 August 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 August 2006 Resolved
Provide metal wiring support for feeder cable to deck reefer van.
Condition: Improper Installation
Due 13 September 2006
Resolved 31 August 2006
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 28 October 2003 Resolved
secure loose handrails throughout accomodation space.
Due 27 November 2003
Resolved 29 June 2004
Electrical › Electric Generation Source (service) › Switch
Issued 28 October 2003 Resolved
Secure wire nuts on port hydrolic steering pump
Due 27 November 2003
Resolved 29 June 2004
Construction/Loadline › Markings › Load Line Mark
Issued 28 October 2003 Resolved
Repaint loadline.
Due 27 November 2003
Resolved 29 June 2004
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 28 October 2003 Resolved
Either remove BA's or replace weak link on BA's.
Due 27 November 2003
Resolved 29 June 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 28 October 2003 Resolved
Repaint vessel's name on ring buoys and hailing port.
Due 27 November 2003
Resolved 29 June 2004
Lifesaving › Inflatable Liferafts › Markings
Issued 28 May 2002 Resolved
ADD VESSEL SPECIFIC LIFE RAFT LAUNCHING INSTRUCTIONS TO EACH LIFERAFT STATION.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2002
Resolved 28 May 2002
Engineering › Lubricating Oil Storage/Transfer System › Vent Pipe
Issued 28 May 2002 Resolved
INSTALL FLAME SCREEN IN LUBE OIL VENT.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2002
Resolved 28 May 2002
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 28 May 2002 Resolved
PROVIDE PROPER NUMBER OF CARTRIDGES.
Due 28 May 2002
Resolved 28 May 2002
Lifesaving
Issued 5 October 1999 Resolved
DEMONSTRATE COMPLINACE WITH THE CCGD8 RESCUE BOAT POLICY LETTER DTD 12 NOV 98, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Fire Fighting
Issued 5 October 1999 Resolved
REMOVE PAINT FROM PAINT LOCKER OR INSTALL USCG APPROVED FIXED CO2 FIRE EXT SYS, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, PRIOR TO 05 NOV99
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Engineering
Issued 5 October 1997 Resolved
VSL TO MAKE VESSEL AVAILABLE FOR INSPECTION OF MDE AND S/S GEN CRANKCASE VENTILATION SYSTEMS PRIOR TO VESSEL OPERATION IN ACCORDANCE WITH 46CFR 126.150.
Condition: Unknown
Due 31 October 1997
Resolved 8 November 1997
Lifesaving
Issued 5 October 1997 Resolved
VSL TO CONDUCT FIRE, BOAT, AND MAN OVBD DRILLS PRIOR TO THE OPERATION OF_x001C_ THE VESSEL IN ACCORDANCE WITH 46CFR 131.530 AND 46CFR 131.535 PRIOR TO THE OPERATION OF THE VESSEL.
Condition: Unknown
Due 31 October 1997
Resolved 8 November 1997

Casualty record · 1

17 July 2013Routine · role: Involved in a Marine Casualty · activity 4661446
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CAROLINE S. (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.