Records from 1997 to 2017. Most recent: inspection, 19 September 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
19 September 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6270483
25 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6132574
11 December 2009
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3648593
19 December 2008
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3376505
18 October 2007
Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3087597
21 September 2006
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2783517
8 September 2006
Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2774227
25 January 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2573367
17 October 2005
Re-Inspection · Internal Structural Exam · Hull Examination · Cargo Tank Internal · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2516067
29 September 2004
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2208441
28 April 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2055525
17 October 2003
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1931999
9 October 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1688092
28 September 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464425
17 February 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 26144
1 October 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 11253
7 October 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393252
28 January 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472751
20 January 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 754092
18 January 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 196935
26 November 1997
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446573
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 September 2006
Resolved
Provide Lifesaving Maintenance Record Log.
Due 21 October 2006
Resolved 22 September 2006
Resolution: Provided Life Saving Maintenance Record.
Lifesaving › Lifefloat › Markings
Issued 21 September 2006
Resolved
Stencil lifefoats with vessel name.
Due 21 September 2006
Resolved 21 September 2006
Resolution: Name stenciled on lifefloat.
Lifesaving › Lifefloat › Paddle
Issued 21 September 2006
Resolved
Tether paddles to individual lifefloats.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 September 2006
Resolved 21 September 2006
Resolution: Tethered paddles to lifefloats.
Lifesaving › Lifefloat › Float Free
Issued 21 September 2006
Resolved
Properly attach lifefloats to weak link.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2006
Resolution: Properly attached lifefloats.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 September 2006
Resolved
Broken floating electric waterlight, not connected to lifefloat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2006
Resolution: New floating electric waterlight attached to lifefloat.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 21 September 2006
Resolved
Provide CG 2692 and 2692B forms for alcohol testing programs.
Due 21 October 2006
Resolved 22 September 2006
Resolution: Provided CG Forms required for alcohol testing.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 21 September 2006
Resolved
Provide Fuel Oil Transfer Procedures at Fuel Pump operating station.
Due 21 October 2006
Resolved 22 September 2006
Resolution: Posted Fuel Oil Transfer Procedures at Fuel Pump operating station.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 21 September 2006
Resolved
Provide Emergency Broadcast Placard.
Due 21 October 2006
Resolved 21 September 2006
Resolution: Provided Emergency Broadcast Placard.
Stability › Watertight Integrity › General
Issued 21 September 2006
Resolved
Demonstrate proper operation of Watertight door indicator on bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2006
Resolution: Repaired Watertight door indicator on bridge.
Construction/Loadline › Hull › Bottom Plating
Issued 8 September 2006
Resolved
The connection of the side shell and bottom plating in the #3 Ballast Tank was found set in and holed.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2006
Resolution: Area was cropped and inserted, dye penetrate tested, examined and approved by ABS.
Bottom Plate - 30" x 20 x 1/2" Plate; Side Shell Plating 21" x 33" x 3/8" Plate;
Swash Bulkhead in way of hull plating 21" x 22" x 3/8" Plate.
Fire Fighting › Fire Pumps › Pressure
Issued 17 October 2005
Resolved
Demonstrate required firemain pressure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: Required pressure met after gaskets re-newed on strainer assy.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 17 October 2005
Resolved
Provide one (01) Ball and one (01) Diamond day shape as required by NAVRULES
Due 25 November 2005
Resolved 25 October 2005
Resolution: Missing dayshapes placed on vessel.
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 17 October 2005
Resolved
Determine and correct full ground on "C" phase of main board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2005
Resolution: Ground found in anchor windlass and corrected.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 17 October 2005
Resolved
Mount compass deviation table.
Action required: 705 - Other - as specified
Due 25 November 2005
Resolved 25 October 2005
Resolution: Table mounted.
Personnel › Certificates/Documents/Licenses
Issued 9 October 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 17 November 2002
Resolved 18 October 2002
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 9 October 2002
Resolved
Provide shaft tachometers in the pilothouse as per 46 CFR 113.37. LEGACY COMPONENT DESC: Propeller Revolutions Rate Indicator
Action required: 705 - Other - as specified
Due 17 November 2002
Resolved 28 September 2004
Resolution: Conversion chart from main engine rpm''s to shaft rpm''s being maintained in the Pilot House.
Stability › Watertight Integrity
Issued 9 October 2002
Resolved
Replace gaskets on three watertight doors. LEGACY COMPONENT DESC: Watertight Door
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2002
Resolved 18 October 2002
Operations/Management › Drills/Instruction
Issued 9 October 2002
Resolved
Provide Emergency Broadcast Placard. LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Action required: 705 - Other - as specified
Due 17 November 2002
Resolved 18 October 2002
Stability › Watertight Integrity
Issued 9 October 2002
Resolved
Adjust watertight door on paint locker to provide a proper seal. LEGACY COMPONENT DESC: Watertight Door
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2002
Resolved 18 October 2002
Lifesaving
Issued 26 November 1997
Resolved
VSL TO CONDUCT FIRE, BOAT, AND MAN OVBD DRILLS IN ACCORDANCE WITH 46CFR 132.530 AND 46CFR 131.535 PRIOR TO PLACING THE VESSEL INTO OPERATION.
Condition: Unknown
Due 26 December 1997
Resolved 22 January 1998