Records from 1997 to 2025. Most recent: inspection, 9 May 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 43
9 May 2025
Internal Structural Exam · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8132053
5 May 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8129093
7 March 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7872917
28 November 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7830925
19 January 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7619305
9 July 2021
COI Inspection · Deficiency Check · Drydock Exam · Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7251005
6 November 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7091270
5 August 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6773905
29 August 2016
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5984336
4 August 2014
DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4944166
5 July 2012
Internal Structural Exam · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4368449
19 June 2012
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4349536
16 April 2008
Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3185484
27 March 2008
Type not recorded
No type recorded · USCGC KISKA (WPB 1336) · USCG Oceania District (CGD-O) · Activity 3182367
24 April 2007
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2914233
30 October 2006
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2810801
26 July 2006
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2725694
22 July 2006
Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 2722481
18 April 2006
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2627424
2 June 2005
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2377110
20 January 2005
Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 2280165
24 June 2004
Hull Examination · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2127594
21 July 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1853136
18 July 2003
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1850161
16 June 2003
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1819202
2 June 2003
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1807951
29 May 2003
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1805041
27 March 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1765872
17 June 2002
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1630731
23 August 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1071680
1 August 2001
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1376707
28 August 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 17112
10 July 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1051567
7 June 2000
Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1376241
7 March 2000
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 815599
10 February 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 76941
3 January 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 55845
8 November 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 97765
8 June 1999
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1416932
4 June 1998
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1467985
28 August 1997
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1120321
14 July 1997
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1120870
10 June 1997
Initial Certification · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1388298
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 May 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have a means to reset devices used to automatically shut down ventilation systems and engines at the operating station. The pre-engineered fixed gas fire extinguishing system failed to reset the engines shut down. Repair the engine reset function of the pre-engineered fixed gas fire extinguishing system to the satisfaction of the attending Marine Inspector.
46 CFR 181.420(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: Service agent repaired the pre-engineered fixed gas fire extinguishing system. The attending Marine Inspector witness the satisfactorily testing of the system's function.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2025
Resolved
Each lifejacket must be approved under approval series in subparts 160.002, 160.005, 160.055, 160.115, 160.176, or 160.255 in part 160 of this chapter, or other standard specified by the Commandant. The lifejackets are not approved under the appropriate approval series for subchapter T vessels. Replace with the approved lifejackets to the satisfaction of attending Marine Inspector.
46 CFR 180.71(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2025
Resolved 14 May 2025
Resolution: Received proof of approved lifejackets carried onboard.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 May 2025
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Ventilation duct opening in the starboard engine space was not equipped with means of closure outside of the engine room. Provide ventilation duct opening closure devices to the satisfaction of the attending Marine Inspector.
46 CFR 182.465(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2025
Resolved 14 May 2025
Resolution: Received proof of ventilation duct opening closures.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 May 2025
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Wing nut is used as connector on the portside battery. Replace with a permananet type battery connector to the satisfaction of attending Marine Inspector.
46 CFR 183.350(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2025
Resolved 14 May 2025
Resolution: Received proof of permanent type connectors made to battery terminals.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 May 2025
Resolved
A vessel that is exposed to salt water more than 3 months in any 12 month period since the last examination must undergo a dry dock examination and an internal structural at least once every two years. Vessel lapsed on getting the dry dock exam and annual completed and must not carry passengers until credit is obtained.
46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: Drydock and COI inspection completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 March 2024
Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Vessel had a 20 inch ring life buoy.
46 CFR 180.70 (a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 25 March 2024
Resolution: Vessel replaced small ring life buoy with correct size.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 7 March 2024
Resolved
Each item of lifesaving equipment carried on board a vessel but not required under this part, must be approved by the Commandant. Hydrostatic release on EPIRB was expired.
46 CFR 180.25(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 20 March 2024
Resolution: Vessel replaced hydrostatic release.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 January 2023
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI. Vessel has two fire buckets, lacking the third. Provide a third fire bucket, with proper "Fire Bucket" label and attach lanyard that reaches to the water when on bow.
46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2023
Resolved 20 January 2023
Resolution: The third fire bucket was provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 December 2021
Resolved
A vessel must comply with the applicable requirements for a station license and installation certificates to be issued by the FCC. The vessel's installation certificate was not current. Provide current, valid, FCC safety certificate.
46 CFR 184.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 6 January 2022
Resolution: A valid FCC Safety Radio Cert for the vessel was provided.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 7 December 2021
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and stern of the vessel. The name of the vessel was not marked on the vessel. Provide proper hull markings of the vessel name.
46 CFR 185.602; 46 CFR 67.123
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 13 December 2021
Resolution: Vessel hull properly marked.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 7 December 2021
Resolved
The official number of the vessel, preceded by "NO." must be in block Arabic numerals not less than 3 inches in height on some clearly visible interior structural part of the hull. The number must permanently affixed to the vessel so that alteration and removal would be obvious. The vessel official number was not marked at all on the vessel. Provide proper marking of the vessels official number.
46 CFR 185.602; 46 CFR 67.121
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 30 December 2021
Resolution: Official number permanently marked as required.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 July 2012
Resolved
Provide radio safety cert.
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 3 August 2012
Lifesaving › Lifefloat › Pendant
Issued 24 April 2007
Resolved
Renew as original wasted lifelines and holes (cracks) in the sin of the lifefloat.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 16 April 2008
Lifesaving › Lifebuoys › Serviceable
Issued 24 April 2007
Resolved
Renew as original lifebouy were damaged.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 16 April 2008
Construction/Loadline › Penetrations › Valve Flange
Issued 24 April 2007
Resolved
Renew as original spool flanges penetrating the hull where wasted. Provide a repair proposal and complete repairs to reduce contact of dissimilar metals.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 16 April 2008
Construction/Loadline › Hull › Hull Plating
Issued 24 June 2004
Resolved
Crop and renew pitted plating in the fuel tank void. Area to be replaced is from aft bulkhead to forward bulkhead and up 2' on both port and stbd sides of CVK.
Action required: 705 - Other - as specified
Due 15 September 2004
Resolved 2 June 2005
Resolution: Bottom plate was re-newed & satisfactorily inspected.
Engineering › Bilge Water Management System › Hose
Issued 16 June 2003
Resolved
Change exsisting bilge pump discharge hose located in engine room .
Condition: Improper Installation
Due 16 June 2003
Resolved 16 June 2003
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 16 June 2003
Resolved
Make proper repairs to #1 stringer located in fuel tank space.
a. 8 inch fracture located on weld port side.
b. 4 inch fracture located on weld stbd side.
Condition: Unknown
Due 30 June 2003
Resolved 24 June 2004
Construction/Loadline › Structures › Machinery Space Opening
Issued 16 June 2003
Resolved
Submit repair plan for port engine bed. Found 3inch crack in outboard isolater beam. LEGACY COMPONENT DESC: Engine bed
Condition: Unknown
Due 30 June 2003
Resolved 24 June 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 May 2003
Resolved
Properly repair leak in exhaust system and prove proper operation of starboard engine prior to carrying passengers. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 31 May 2003
Resolved 31 May 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 29 May 2003
Resolved
Provide servicing report for fixed fire system prior to carrying passengers. System was discharged due to fire in engine room LEGACY COMPONENT DESC: Tanks
Condition: Damaged By Earlier Event
Due 31 May 2003
Resolved 31 May 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 June 2002
Resolved
Properly remove or repair dead end wires at operating station.
Condition: Placed in Improper Service
Due 17 June 2002
Resolved 26 June 2002
Construction/Loadline › Hull
Issued 17 June 2002
Resolved
Found 1 inch crack on port side bottom runner located in fuel tank space. Submit repair proposal IAW 46 CFR176.700. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Due 17 June 2002
Resolved 27 June 2002
Resolution: Installed a 6''''-2" long by 8" insert. Repairs completed IAW MSO Honolulu inspection note #37.
Construction/Loadline › Hull
Issued 17 June 2002
Resolved
Properly repair sewage tank mounts. Welds are fractured. LEGACY COMPONENT DESC: Sewage tank mounts
Condition: Unknown
Due 17 June 2002
Resolved 27 June 2002
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 June 2002
Resolved
Provide proof of valid COI.
Condition: Unknown
Due 17 June 2002
Resolved 27 June 2002
Navigation › Piloting/Steering › US Coast Pilot
Issued 17 June 2002
Resolved
Provide US Coast Pilot.
Condition: Unknown
Due 17 June 2002
Resolved 27 June 2002
Construction/Loadline
Issued 1 August 2001
Resolved
Install positive shutoff valve at hull penetration for bilge pump overboardIAW 46 CFR 182.520(E)(7) NLT 01SEP01.
Condition: Unknown
Due 23 August 2001
Resolved 25 August 2001
Fire Fighting
Issued 1 August 2001
Resolved
Provide engine room vent closure IAW 46 CFR 182.465 (H) NLT 01SEP01.
Condition: Unknown
Due 23 August 2001
Resolved 25 August 2001
Lifesaving
Issued 1 August 2001
Resolved
Prove proper operation of (406 MHZ) EPIRB IAW 46 CFR 180.64 NLT 15AUG01. Vessel is limited to three miles from shore IAW 46 CFR 180.64 until in compliance.
Condition: Unknown
Due 23 August 2001
Resolved 25 August 2001
Navigation
Issued 7 June 2000
Resolved
Replace starboard aft bridge window which is cracked. 46CFR 176.610.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Lifesaving
Issued 7 June 2000
Resolved
Add retro-reflective tape to ring buoy iaw 46CFR 185.604(h).
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Lifesaving
Issued 7 June 2000
Resolved
Restock or replace 1st Aid Kit so that it meets requirements contained in 46CFR 160.041.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Engineering
Issued 7 June 2000
Resolved
Replace rusted connection to fuel tank/hose iaw 46CFR 182.720. Hose/connection must be listed in SAE J1942.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Lifesaving
Issued 7 June 2000
Resolved
Replace (1) paddle of (4) found broken within lifefloat assembly atop cabin iaw 46CFR 180.175(d). Recommend replace (2) plastic paddles with a pair of wooden paddles as carried for second lifefloat._x001C_ _x001C_
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Lifesaving
Issued 7 June 2000
Resolved
Replace (1) adult and (2) children's lifejackets to meet requirements of 46CFR 180.71. Vessel limited to the carriage of (1) child (adult less than90lbs) until corrected.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Electrical
Issued 7 June 2000
Resolved
Provide (2) flashlights to meet requirement of 46CFR 183.430.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Fire Fighting
Issued 4 June 1998
Resolved
No B-II extinguishers on board vessel as required by COI. Required vessel representitive to provide extinguishers prior to completion of reinspection. Extinguishers were provided as required and cleared deficiency.
Condition: Unknown
Due 4 June 1998
Resolved 22 June 1998
Documentation
Issued 10 June 1997
Resolved
PROVIDE DOCUMENTATION NUMBER
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Lifesaving
Issued 10 June 1997
Resolved
PROVIDE ADDITIONAL 7 LIFEJACKETS TO MEET COI.
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Lifesaving
Issued 10 June 1997
Resolved
LIFEJACKET DONNING DONNING INSTRUCTIONS NEED TO BE POSTED.
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Documentation
Issued 10 June 1997
Resolved
PROVIDE COPY OF VESSEL DOCUMENTATION
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Documentation
Issued 10 June 1997
Resolved
POSTING OF THE PLACARDS- MARPOL GARBAGE, MARPOL OIL DISCHARGE, EMERGENCY CREW INSTRUCTIONS.
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Lifesaving
Issued 10 June 1997
Resolved
MARK LIFE-RING WITH VESSEL NAMES.
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Lifesaving
Issued 10 June 1997
Resolved
THE LIFEFLOATS NEED TO BE MARKED WITH VESSELS NAME, ATTACH FLOAT LIGHT, SECURE SEA PAINTER.
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Navigation
Issued 10 June 1997
Resolved
PROVIDE STATION LISCENSE, CALL SIGN, AND EMERGENCY INSTRUCTION .
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Navigation
Issued 10 June 1997
Resolved
PROVIDE COMPASS DEVIATION TABLE.
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Lifesaving
Issued 10 June 1997
Resolved
PROVIDE THE FOLLOWING: BRIGHTLY COLORED BOX FOR FLARES. FIRST AID KIT, 1 HAND BILGE PUMP, 3 BUCKETS LABELED FOR FIRE USE ONLY.
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Electrical
Issued 10 June 1997
Resolved
PROVIDE TWO HAND HELD FLASH LIGHTS.
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Unknown
Issued 10 June 1997
Resolved
PROVIDE DRUG TESTING PROGRAM.
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Documentation
Issued 10 June 1997
Resolved
PROVIDE COPY OF MASTERS LISCENSE.
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997