DEL MONTE is a 1968 freight ship. The Coast Guard has recorded 44 inspections since 1982, most recently in October 1999, along with 16 deficiencies.

Records from 1982 to 1999. Most recent: inspection, 14 October 1999.

Built
1968
Last inspected
14 October 1999
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6804240 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-45901

Inspections, by type

…with no type recorded24
Years with a record 16 calendar years (1982–1999)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)487.0 ft × 70.0 ft × 45.0 ft
Registered tonnagegross 10,396 / net 6,299
ITC dimensions (L × B × D)487.0 ft × 70.0 ft × 45.0 ft
ITC tonnagegross 10,669 / net 5,639
BuilderTHE INGALLS SHIPBUILDING · PASCAGOULA, MS, UNITED STATES · built 1968
Hull materialSteel
PropulsionSteam Turbine
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWASHINGTON, DC
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10396 - Regulatory (Subpart C or D), Gross Ton
10669 - Convention (Subpart B), Gross Ton
10400 - Displacement, Gross Ton
6299 - Regulatory (Subpart C or D), Net Ton
13039 - Dead Weight, Ton
5639 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WNVWMMSI not assigned · expired · compulsorily equipped · granted 20 December 1994, cancelled 16 April 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 44

14 October 1999 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 787489
20 March 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1418501
11 January 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 811435
28 December 1998 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 807607
21 February 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1192298
19 January 1994 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1165392
2 March 1993 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1150342
18 March 1992 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1318517
5 March 1992 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1316267
14 February 1992 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 959891
22 January 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1260702
9 September 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 932301
3 September 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 466119
24 August 1991 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 220708
2 July 1991 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 173071
24 May 1991 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 901082
30 April 1991 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1212892
13 February 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 513159
10 February 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 905424
2 February 1991 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1247794
25 January 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 923779
14 January 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 922259
27 December 1990 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 918081
26 December 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1227529
20 December 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 915008
19 December 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1238453
8 December 1990 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1241628
19 November 1990 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1244162
1 September 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 925785
8 February 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1240898
23 February 1989 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1042835
8 October 1988 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1195754
16 December 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1314977
15 October 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1322441
14 January 1987 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1020829
20 February 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 989013
8 October 1985 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 986484
18 July 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 981952
28 May 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 985763
21 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 978165
31 January 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972437
18 April 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968064
19 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278819
23 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276503

Deficiency record · 16

Unknown
Issued 19 January 1994 Resolved
MAKE VESSEL AVAILABLE FOR INSPECTION AND CONDUCT COMPLETE INSPECTION FOR CERTIFICATION PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 January 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 22 January 1992 Resolved
MAKE PERMANENT REPAIR TO BULKHEADS IN THE A/C VENTILATION ROOM (FORWARD HOUSE)
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Lifesaving
Issued 22 January 1992 Resolved
COMPLETE A WEIGHT TEST AND OPERATIONS TEST OF THE #1 (STARBOARD) LIFEBOAT.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Accommodation/Occupational Safety
Issued 22 January 1992 Resolved
MAINTAIN TEMPORARY REPAIRS (RED HAND) ON FORWARD SANITARY PRESSURE VESSEL UNTIL PERMANENT CAN BE MADE. THEN PRESENT VESSEL FOR INTERNAL EXAM OR HYDRO AT 1.5 MAWP.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Construction/Loadline
Issued 22 January 1992 Resolved
MAKE PERMANENT REPAIR TO CENTER CELL TRANSVERSE BULKHEAD BETWEEN #5 & #6 CARGO HOLD.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Electrical
Issued 22 January 1992 Resolved
REPAIR OR REPLACE MISSING INSULATION LAGGING ON BOTH STEAM TURBO GENERATOR SETS (UPPER CASTING)
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Accommodation/Occupational Safety
Issued 22 January 1992 Resolved
FABRICATE AND INSTALL GUARD FOR AIR PUMP AGITATOR VEE-BELT ON FORWARD MSD TANK.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Engineering
Issued 22 January 1992 Resolved
CONDUCT TEST OF OILY WATER SEPERATOR FOR ANNUAL IOPP EXAM.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Engineering
Issued 9 September 1991 Resolved
MAKE OPERABLE OR REMOVE ENTIRELY THE BRIDGE THROTTLE CONTROL SYSTEM. SYSTEMIS NOT TO BE USED FOR ANY REASON UNTIL COMPLETED.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Engineering
Issued 9 September 1991 Resolved
MAKE PERMANENT REPAIRS TO THE BOILER BOTTOM BLOW LINE STBD SIDE LOWER LEVELENGINE ROOM. TEMPORARY CEMENT BOX AUTHORIZED.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Engineering
Issued 2 February 1991 Resolved
EFFECT PERMANENT REPAIRS TO THE MAIN ENGINE CIRCULATING 24" BUTTERFLY VALVES IN WAY OF THE MAIN CONDENSER HIGH/LOW SUCTION AND OVERBOARD DISCHARGE VALVES.
Condition: Unknown
Due 2 February 1991
Resolved 2 February 1991
Engineering
Issued 27 December 1990 Resolved
STARBOARD BOILER IS TO BE MADE AVAILABLE FOR INTERNAL EXAMINATION. PERMANENT REPAIRS TO BOILER TUBING ARE TO BE ACCOMPLISHED TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Engineering
Issued 27 December 1990 Resolved
PORT BOILER IS TO BE MADE AVAILABLE FOR INTERNAL EXAMINATION. REPAIRS TO TUBING AND/OR SHEETS TO BE DETERMINED AT THIS INSPECTION.
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Construction/Loadline
Issued 20 December 1990 Resolved
test both firmain and ballast lines in #2 liq. cargo tanks to the _x001C_ satisfaction MSO JACKSONVILLE _x001C_
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Lifesaving
Issued 15 October 1987 Resolved
CONDUCT WEIGHT TEST OF #1 LIFEBOAT.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Unknown
Issued 18 April 1983 Resolved
PROVIDE OPERABLE CONTINUOUS DEPTH RECORDER.
Condition: Unknown
Due 18 April 1983
Resolved 18 April 1983