MAURY USCG vessel records Sign in
← All vessels

PACIFIC HORIZON

PACIFIC HORIZON is a 1968 passenger vessel (inspected). The Coast Guard has recorded 85 inspections since 1985, most recently in July 2012, along with 184 deficiencies — 2 with no resolution recorded —, 2 operational controls and 2 casualty investigations between 2011 and 2012.

Records from 1985 to 2012. Most recent: operational control imposed, 13 July 2012.

Built
1968
Last inspected
13 July 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD5348
Flag
UNITED STATES
—
Maury page id
psix-45927

Inspections, by type

…with no type recorded22
…past their stated due date1
Years with a record 26 calendar years (1985–2012)
The 85 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it60 - Regulatory (Subpart C or D), Gross Ton
43 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCV8184MMSI not assigned · expired · compulsorily equipped · granted 24 January 1996, cancelled 1 April 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 85

13 July 2012 Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4378017
13 July 2012 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4412618
10 July 2012 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4378013
13 February 2012 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4243324
7 September 2011 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4140197
19 July 2011 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4089177
11 March 2010 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3693555
26 January 2010 In-Service Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3670035
23 April 2009 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3458912
28 February 2008 Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3155229
22 September 2007 Type not recorded
No type recorded · Station Morro Bay · USCG Southwest District (CGD-SW) · Activity 3063994
9 January 2007 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2852822
7 April 2006 Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2619715
5 May 2005 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2351025
28 April 2004 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2055674
10 March 2004 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2022708
15 December 2003 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1965282
29 October 2003 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1938558
14 July 2003 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1846521
20 February 2003 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1747292
19 December 2001 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1481365
6 March 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1435156
19 January 2001 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1403277
10 January 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1461346
23 June 2000 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395490
6 June 2000 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1420342
10 March 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1426341
29 November 1999 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 815104
18 August 1999 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1384227
14 July 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 725168
23 June 1999 Examination of Repairs · Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1437564
28 May 1999 Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 804164
15 May 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 93229
15 May 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 226872
25 March 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 779165
12 February 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1128080
4 January 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372451
28 October 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1409968
15 September 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 800117
14 January 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1398823
24 December 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385860
8 November 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1470423
17 October 1996 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1155564
11 September 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1414693
7 August 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1088388
6 April 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 6248
28 December 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1374459
14 September 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 204035
14 September 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 754346
2 July 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 52759
6 May 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 166486
22 March 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1461626
13 January 1995 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 865256
10 January 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1170893
24 January 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 851630
12 January 1994 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 853887
25 September 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 54809
16 September 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 834514
7 January 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1136727
6 February 1992 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1267770
14 January 1992 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1256223
1 December 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 11329
11 October 1991 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1248631
12 September 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1249189
11 September 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 655588
11 March 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 902969
19 February 1991 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1223993
23 January 1991 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1221743
4 January 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1223989
30 April 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1235135
17 January 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 920316
12 December 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241473
26 October 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 893247
20 September 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1208916
16 May 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1210315
9 May 1989 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1043732
12 April 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 888603
14 March 1988 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1336434
7 October 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1012852
6 October 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1320492
22 May 1987 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1025354
9 February 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1322497
25 March 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1302305
10 March 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1298649
4 March 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 978683

Deficiency record · 184

Construction/Loadline › Hull › Hull Plating
Issued 13 July 2012 No resolution recorded
Vessel must complete hull exam prior to the carriage of passengers
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 July 2012 No resolution recorded
Vessel must complete satisfactory COI exam prior to returning to passenger operation.
Action required: 705 - Other - as specified
Due 5 November 2012 — due date passed with no resolution recorded
Construction/Loadline › Hull › Bracket
Issued 13 February 2012 Resolved
Treat dry rot located STBD quarter. Leak due to water coming in from the stern cleat.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 8 March 2012
Accommodation/Occupational Safety › Potable Water System › General
Issued 13 February 2012 Resolved
Secure mini fridge in accommodation space.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 8 March 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 February 2012 Resolved
Conduct training and post first aid instruction card
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 8 March 2012
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 February 2012 Resolved
Condemned 13 adult life jackets due to weather rot. Vessel restricted to 34 POB until new lifejackets are provided.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 8 March 2012
Communications › Radio Communications › EPIRB
Issued 13 February 2012 Resolved
Proof provided for EPIRB registration however missing sticker. Provide EPIRB sticker.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 8 March 2012
Engineering › Bilge Water Management System › Not Operational
Issued 13 February 2012 Resolved
Repair bilge alarm in E/R and collision compartment. Confirm visual but no audio on the bridge.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 8 March 2012
Engineering › Steering Gear System › Ram
Issued 13 February 2012 Resolved
Secure steering ram mounting block. The wooden block is rotted resulting in unsecure ram.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 8 March 2012
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 13 February 2012 Resolved
Repair STBD M/E exhaust water leak. Water is leaking at the mixer.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 8 March 2012
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 13 February 2012 Resolved
Provide and post first aid and CPR instruction card.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 8 March 2012
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 March 2010 Resolved
Service all fire fighting equipment NLT 01APR10
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 17 March 2010
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 11 March 2010 Resolved
Calibrate alco tester or provide disposables
Action required: 705 - Other - as specified
Due 11 April 2010
Resolved 6 May 2010
Lifesaving › Inflatable Liferafts › Servicing
Issued 11 March 2010 Resolved
Service life rafts NLT 01APR10
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 24 March 2010
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 11 March 2010 Resolved
Replace fwd L/R HRU NLT 01APR10
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 24 March 2010
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 11 March 2010 Resolved
Remove or replace failing insulation on E/R overhead.
Action required: 705 - Other - as specified
Due 11 April 2010
Resolved 6 May 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 March 2010 Resolved
Remove discontinued wiring for fish hold discharge pump.
Action required: 705 - Other - as specified
Due 11 April 2010
Resolved 6 May 2010
Engineering › Steering Gear System › Linkage
Issued 11 March 2010 Resolved
Repair auto-pilot connection to tiller.
Action required: 705 - Other - as specified
Due 11 April 2010
Resolved 6 May 2010
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 11 March 2010 Resolved
Secure stbd genset fuel return line
Action required: 705 - Other - as specified
Due 11 April 2010
Resolved 6 May 2010
Electrical › Electrical Distribution System (service) › Switch
Issued 11 March 2010 Resolved
Secure receptacle switch in stbd MSD compartment
Action required: 705 - Other - as specified
Due 11 April 2010
Resolved 6 May 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 March 2010 Resolved
Identify and remove unused 12V & AC wiring/switches in E/R and under console.
Action required: 705 - Other - as specified
Due 11 April 2010
Resolved 6 May 2010
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 11 March 2010 Resolved
Label emergency fuel shut-offs
Action required: 705 - Other - as specified
Due 11 April 2010
Resolved 6 May 2010
Documentation › Markings/Placards › Warning Signs
Issued 11 March 2010 Resolved
Renew stenciling/placards after painting is complete.
Action required: 705 - Other - as specified
Due 11 April 2010
Resolved 6 May 2010
Communications › Radio Communications › EPIRB
Issued 23 April 2009 Resolved
Prior to carrying psgrs >3 NM, provide EPIRB (Cat 1).
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2009
Resolved 30 April 2009
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 23 April 2009 Resolved
Post EAP info w/hotline # on boats or in office.
Action required: 705 - Other - as specified
Due 23 May 2009
Resolved 28 April 2009
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 April 2009 Resolved
Determine SAP contact info.
Action required: 705 - Other - as specified
Due 23 May 2009
Resolved 28 April 2009
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 23 April 2009 Resolved
Install closure devices on E/R vent closures.
Action required: 705 - Other - as specified
Due 23 May 2009
Resolved 28 April 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 April 2009 Resolved
Clean & assess wet exhaust piping stbd side of aft E/R bulkhead.
Action required: 705 - Other - as specified
Due 23 May 2009
Resolved 28 April 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 April 2009 Resolved
Replace wasted hose in washdown pump piping (E/R)
Action required: 705 - Other - as specified
Due 23 May 2009
Resolved 28 April 2009
Electrical › Electric Supply System (service) › Cable
Issued 23 April 2009 Resolved
Remove all unused wiring.
Action required: 705 - Other - as specified
Due 23 May 2009
Resolved 28 April 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 April 2009 Resolved
Replace damaged raw water cooling intake hose for genset.
Action required: 705 - Other - as specified
Due 23 May 2009
Resolved 28 April 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 April 2009 Resolved
Stabilize / repair upper deck railing, port & stbd.
Action required: 705 - Other - as specified
Due 23 May 2009
Resolved 30 June 2009
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 16 April 2008 Resolved
Install e-light by emergency hatch in the sleeping accomodation space.
Due 16 May 2008
Resolved 17 June 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 16 April 2008 Resolved
Install metalic thru-hull fitting in the fwd compartment.
Due 16 May 2008
Resolved 17 June 2008
Documentation › Certificates/Documents › Stability Letter
Issued 17 March 2008 Resolved
Locate Stability Letter and post
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 18 March 2008
Fire Fighting › Means of Escape › Blocked
Issued 17 March 2008 Resolved
Forward emergency escape hatch: make operable from both sides (46 CFR 171.124(c))
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 17 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 March 2008 Resolved
Organize wiring below bridge console, and remove obsolete wiring.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 16 April 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 March 2008 Resolved
Strengthen 01 deck railing.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 16 April 2008
Engineering › Bilge Water Management System › Pump
Issued 17 March 2008 Resolved
Repair primary bilge pump (manifold system) and prove proper operation.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 16 April 2008
Operations/Management › Pollution › Control of Discharge of Oil
Issued 17 March 2008 Resolved
Clean E/R bilge & laz bilge.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 16 April 2008
Engineering › Fuel Oil Service System › Hose
Issued 17 March 2008 Resolved
Make line drawing of fuel distribution incl. hose lengths and hose type.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 16 April 2008
Engineering › Fuel Oil Service System › Hose
Issued 17 March 2008 Resolved
Install chafing gear for port MDE fuel line.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 16 April 2008
Fire Fighting › Grease Extraction Hood › General
Issued 17 March 2008 Resolved
Request galley grill hood fixed f/f exemption.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 23 April 2009
Resolution: Deleted requirement.
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 March 2008 Resolved
Repair wet exhaust line water leak port side of laz.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 16 April 2008
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 17 March 2008 Resolved
Prior to carrying overnight passengers, repair smoke detector in berthing.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 16 April 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 March 2008 Resolved
Repair stbd galley window.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 16 April 2008
Engineering › Steering Gear System › Ram Seal
Issued 9 January 2007 Resolved
Leaking STBD ram seal in lazarette.
Condition: Unknown
Due 10 February 2007
Resolved 20 February 2007
Construction/Loadline › Penetrations › Valve Flange
Issued 9 January 2007 Resolved
Frozen STBD overboard discharge valve to the bait tank.
Condition: Improper/Lack of Maintenance
Due 10 February 2007
Resolved 20 February 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 January 2007 Resolved
Improper supports for electrical wiring in E/R.
Condition: Improper Installation
Due 10 February 2007
Resolved 20 February 2007
Engineering › Fuel Oil Service System › Piping
Issued 9 January 2007 Resolved
Improper type of hose used on port side generator to fuel filter.
Condition: Improper Installation
Due 10 February 2007
Resolved 20 February 2007
Engineering › Fuel Oil Service System › Hose
Issued 9 January 2007 Resolved
Improper type of hose used on stbd side generator to fuel filter.
Condition: Improper Installation
Due 10 February 2007
Resolved 20 February 2007
Electrical › Electric Generation Source (service) › Generator Cable
Issued 9 January 2007 Resolved
Unconnected ground cable on the port generator.
Condition: Unknown
Due 10 February 2007
Resolved 20 February 2007
Engineering › Steering Gear System › Hydraulic Hose
Issued 9 January 2007 Resolved
Worn hydraulic steering line (located above port fuel tank).
Condition: Improper/Lack of Maintenance
Due 10 February 2007
Resolved 20 February 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 9 January 2007 Resolved
Excess oil in E/R bilge.
Due 10 February 2007
Resolved 20 February 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 January 2007 Resolved
COI expired on 20 DEC 2006.
Due 9 January 2007
Resolved 9 January 2007
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 9 January 2007 Resolved
Secure freezer in the sewage comp.
Action required: 705 - Other - as specified
Due 20 February 2007
Resolved 20 February 2007
Engineering › Steering Gear System › Hydraulic Hose
Issued 9 January 2007 Resolved
Repair hydraulic leak under pilot control station.
Condition: Unknown
Due 20 February 2007
Resolved 20 February 2007
Construction/Loadline › Penetrations › Valve Flange
Issued 9 January 2007 Resolved
Unfreeze valve in the chain locker.
Condition: Improper/Lack of Maintenance
Due 20 February 2007
Resolved 20 February 2007
Lifesaving › Lifefloat › Retroreflective Material
Issued 9 January 2007 Resolved
Install reflective tape on 6 lifefloat
Condition: Unknown
Due 20 February 2007
Resolved 20 February 2007
Documentation › Logs/Records › Drug Test Records
Issued 9 January 2007 Resolved
Provide drug test results for FY06
Condition: Unknown
Due 20 February 2007
Resolved 20 February 2007
Electrical › Electric Supply System (service) › Cable
Issued 9 January 2007 Resolved
Refit shore connection eliminating excess cord as discussed. Provide approved 220 connection for shore power connection.
Due 20 February 2007
Resolved 20 February 2007
Electrical › Electric Supply System (service) › Cable
Issued 9 January 2007 Resolved
Secure shore power connection located above galley vent hood (stbd).
Due 20 February 2007
Resolved 20 February 2007
Lifesaving › Buoyant Apparatus › Painter
Issued 9 January 2007 Resolved
Replace wasted painter line for the life ring.
Due 20 February 2007
Resolved 20 February 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 9 January 2007 Resolved
Replace fwd bait pump supply cable from the junction box.
Due 20 February 2007
Resolved 20 February 2007
Deck/Cargo › Fishing › General
Issued 9 January 2007 Resolved
Repair/replace fwd bait pump supply line. Remove splash zone repairs located in engine room.
Due 20 February 2007
Resolved 20 February 2007
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 9 January 2007 Resolved
Remove excess grease from the grill grease trap.
Due 20 February 2007
Resolved 20 February 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 April 2006 Resolved
Complete overdue annual and hull inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2006
Resolved 26 April 2006
Documentation › Certificates/Documents › FCC SSL
Issued 7 April 2006 Resolved
Register and provide FCC ship station certificate.
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 20 February 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 April 2006 Resolved
Provide updated nav pubs.
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 20 February 2007
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 7 April 2006 Resolved
Repair fixed fire system indicator light.
Due 26 May 2006
Resolved 20 February 2007
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 May 2005 Resolved
Provide retro reflective tape for child PFD's as needed.
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 26 April 2006
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 5 May 2005 Resolved
Mark circuit breakers in panel boxes in E/R, galley and bunkroom.
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 26 April 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 May 2005 Resolved
Replace broken window in galley - starboard side/aft.
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 26 April 2006
Construction/Loadline › Penetrations › Pipe Flange
Issued 5 May 2005 Resolved
Provide watertight integrity for hole penetrating through bulkhead between E/R and bunkroom.
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 26 April 2006
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 5 May 2005 Resolved
Provide ventilation closure for both port and starboard vents in E/R.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2005
Resolved 5 May 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 May 2005 Resolved
Repair ladder going from main deck to pilot house.
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 26 April 2006
Operations/Management › Pollution › Removal Methods/Procedures
Issued 5 May 2005 Resolved
Clean bilge (excess oil) in E/R - provide receipt for disposal.
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 26 April 2006
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 May 2005 Resolved
Repair/replace smoke detector in bunkroom.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2005
Resolved 5 May 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 May 2005 Resolved
Repair rail starboard side above pilot house ladder.
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 26 April 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 May 2005 Resolved
Stencil vessels name on both liferings.
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 26 April 2006
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 28 April 2004 Resolved
Provide 30X30 mesh screen for fuel vents IAW 46CFR182.450 (e).
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2004
Resolved 28 April 2004
Resolution: Provided 30X30 mesh screen for fuel vents IAW 46CFR182.450 (e).
Accommodation/Occupational Safety › Occupational Safety
Issued 28 April 2004 Resolved
Mark both sides of escape hatch IAW 46 CFR 185.606.
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 28 April 2004
Resolution: Marked both sides of escape hatch IAW 46 CFR 185.606.
Communications › Radio Communications › EPIRB
Issued 28 April 2004 Resolved
Renew 406 EPIRB battery. Vessel restricted to 3 mile until corrected.
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 10 May 2004
Resolution: Renewed 406 EPIRB battery.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 28 April 2004 Resolved
Prove proper charge of all portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2004
Resolved 28 April 2004
Resolution: Proved proper charge of all portable fire extinguishers.
Navigation › Piloting/Steering › Marine Charts
Issued 28 April 2004 Resolved
Provide proper and up-dated charts.
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 28 April 2004
Resolution: Provided proper and up-dated charts.
Accommodation/Occupational Safety › Occupational Safety
Issued 28 April 2004 Resolved
Repair ladder going up to pilothouse.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2004
Resolved 28 April 2004
Resolution: Repaired ladder going up to pilothouse.
Construction/Loadline › Structures
Issued 10 March 2004 Resolved
Make cable and piping penetrations through collision bulkhead watertight. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2004
Resolved 28 April 2004
Electrical › Electrical Distribution System (service)
Issued 10 March 2004 Resolved
Properly wire sanitary system controls on starboard side of mid-ship freezer compartment. LEGACY COMPONENT DESC: Wiring
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2004
Resolved 28 April 2004
Electrical › Electrical Distribution System (service)
Issued 10 March 2004 Resolved
Provide cover for electrical outlet on forward bulkhead on starboard side of freezer compartment. LEGACY COMPONENT DESC: Outlet Box
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2004
Resolved 28 April 2004
Construction/Loadline › Penetrations
Issued 10 March 2004 Resolved
Secure through hull penetration on port side of freezer compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2004
Resolved 28 April 2004
Engineering › Fuel Oil Service System
Issued 29 October 2003 Resolved
Properly install flexible hose return line for diesel fuel to both port and stbd generators iaw 46 CFR 182.720(e). LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 15 December 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 29 October 2003 Resolved
Install proper safety guards covering rotating pullies and belts for both port and starboard generators. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 15 December 2003
Engineering › Fuel Oil Service System
Issued 29 October 2003 Resolved
Reposition fuel supply hose for port generator so as not to be subject to failure if the pump pulley breaks. Fuel hose would possibly be ruptured in the event of a belt failure. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 10 March 2004
Engineering › Bilge Water Management System
Issued 11 June 2003 Resolved
Replace engine room flexible hose in bilge piping IAW 46CFR182.720. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 1 July 2003
Resolution: Cleared and reissued.
Engineering › Fuel Oil Service System › Filter
Issued 11 June 2003 Resolved
Renew or replace generator fuel filter flame impingement bowl.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2003
Resolved 30 June 2003
Resolution: Renewed generator fuel filter flame impingement bowl.
Construction/Loadline › Penetrations
Issued 11 June 2003 Resolved
Install proper engine room aft bulkhead penetrations IAW 46CFR182.720.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2003
Resolved 30 June 2003
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 11 June 2003 Resolved
Provide means to disable MSD Type III holding tank overboard discharge valves.
Action required: 705 - Other - as specified
Due 11 July 2003
Resolved 30 June 2003
Resolution: Provided means to disable MSD Type III holding tank overboard discharge valves.
Documentation › Certificates/Documents
Issued 20 February 2003 Resolved
Haul vessel out of the water and make available for biennial hull exam. LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2003
Resolved 11 June 2003
Resolution: Hauled vessel for hull exam.
Deck/Cargo › Mooring/Anchoring
Issued 19 December 2001 Resolved
Configure anchor and tackle to be used in an emergency (loss of propulsion, steering etc...). LEGACY COMPONENT DESC: Anchor Chain (general)
Condition: Improper/Lack of Maintenance
Due 19 January 2002
Resolved 30 January 2002
Communications › Audible Communications
Issued 19 December 2001 Resolved
Repair or replace whistle to comply with Annex III Rules of the Road. LEGACY COMPONENT DESC: Horn/Whistle
Condition: Improper/Lack of Maintenance
Due 19 January 2002
Resolved 30 January 2002
Resolution: A new whistl was installed and tested.
Accommodation/Occupational Safety › Occupational Safety
Issued 19 December 2001 Resolved
Secure or renew ladder to wheelhouse.
Condition: Improper/Lack of Maintenance
Due 19 January 2002
Resolved 30 January 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 19 December 2001 Resolved
Mount B II fire extinguisher (under captains chair) in CG approved bracket. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper Installation
Due 19 January 2002
Resolved 30 January 2002
Resolution: Operator revoved the B-II (he has 2 B-Is properly mounted on the aft cabin bulkhead).
Fire Fighting
Issued 10 January 2001 Resolved
Prove proper operation of engine room fixed fire fighting system engine shutdowns prior to taking passengers for hire.
Condition: Unknown
Due 10 January 2001
Resolved 10 January 2001
Documentation
Issued 10 January 2001 Resolved
Provide valid FCC Safety Radiotelephone Certificate.
Condition: Unknown
Due 10 February 2001
Resolved 30 January 2002
Resolution: Certificate Issued 17DEC01.
Electrical
Issued 10 January 2001 Resolved
Make repairs and prove proper operation of the port ship service generator PRIOR TO USE. Wiring of generator shall be I.A.W. 46 CFR 183.340(g)
Condition: Unknown
Due 10 February 2001
Resolved 1 July 2003
Lifesaving
Issued 10 January 2001 Resolved
Prove proper operation of public address system in overnight accommodation space prior to taking overnight passengers for hire, I.A.W. 46 CFR 183.550.
Condition: Unknown
Due 10 January 2001
Resolved 10 January 2001
Construction/Loadline
Issued 6 June 2000 Resolved
CONDUCT SEA TRIALS IN THE PRESENCE OF, AND TO THE SATISFACTION OF, A COAST GUARD MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Electrical
Issued 6 June 2000 Resolved
MAKE REPAIRS TO STBD GENERATOR AND RECONNECT WIRES IAW 46 CFR 183.340(G)
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Accommodation/Occupational Safety
Issued 10 March 2000 Resolved
REPAIR AS NEW AND PROVE PROPER OPERATION OF THE EMERGENCY LIGHTING IN THE PASSENGER ACCOMMODATION SPACE.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Fire Fighting
Issued 10 March 2000 Resolved
PROVED PROOF OF ANNUAL SERVICING FOR FIXED FIRE EXTINGUISHING SYSTEM IN THEENGINE ROOM.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Engineering
Issued 10 March 2000 Resolved
REPAIR AS NEW FRESH WATER SYSTEM ON THE PORT SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 10 March 2000
Resolved 16 March 2000
Engineering
Issued 10 March 2000 Resolved
INSTALL EXHAUST LAGGING ON THE PORT GENERATOR AND PORT MAIN PROPULSION ENGINE.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Engineering
Issued 10 March 2000 Resolved
CLEAN AND SERVICE FUEL FITLERS ON BOTH MAIN ENIGNES AND THE SHIPS SERVICE GENERATOR PRIME MOVER.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Lifesaving
Issued 10 March 2000 Resolved
REPLACE WEAK LINK AND WEAK LINK LINE FOR LIFEFLOATS.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Construction/Loadline
Issued 10 March 2000 Resolved
INSTALL HIGH LEVEL BILGE ALARMS IN THE FORE PEAK.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Construction/Loadline
Issued 10 March 2000 Resolved
INSTALL CAPTIVE CHAIN ON WATERTIGHT SCUTTLE FOR THE LAZARETTE.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Engineering
Issued 10 March 2000 Resolved
REPAIR AS NEW FRESH WATER TEMPERATURE GAUGE FOR THE PORT SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Electrical
Issued 10 March 2000 Resolved
PROPERLY SECURE WIRE RUNS THROUGHOUT THE ENGINE ROOM.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Engineering
Issued 11 September 1996 Resolved
REPLACE FUEL VENT ON PORT SIDE WITH 30X30 MESH.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Engineering
Issued 11 September 1996 Resolved
CLEAN AND TREAT FURRING ON PORT AND STARBOARD ENGINEROOM VENTS.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Construction/Loadline
Issued 11 September 1996 Resolved
CONDUCT UNDERWAY CHECKRIDE WITH CG INSPECTOR TO EXAMINE STRUCTURAL INTEGRITY.
Condition: Unknown
Due 18 September 1996
Resolved 17 September 1996
Accommodation/Occupational Safety
Issued 11 September 1996 Resolved
REPLACE PORT AND STARBOARD PILOT HOUSE WINDOWS.
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 10 January 1995 Resolved
CLEAN AND TREAT OR SCARF AND RENEW AS NEEDED ROT AREAS IN LAZARETTE AND TANK ROOM AT NEXT DRYDOCKING.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Lifesaving
Issued 10 January 1995 Resolved
PERFORM MAN OVERBOARD DRILL NO LATER THAN 20 JAN 95.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Fire Fighting
Issued 10 January 1995 Resolved
PERFORM FIRE DRILL NO LATER THAN 20 JAN 95.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Electrical
Issued 12 January 1994 Resolved
PROPERLY BLANK OFF OPENING ON THE CIRCUIT BREAKER PANEL IN THE ENGINE ROOM.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Lifesaving
Issued 12 January 1994 Resolved
PRIOR TO OPERATING WITH MORE THAN 44 PERSONS, PROVIDE TWO ADULT TYPE I PFD'S.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Navigation
Issued 12 January 1994 Resolved
PROVIDE UP TO DATE COPY OR PROPERLY CORRECT THE LIGHT LIST, COAST PILOT, AND CHART 18740.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Engineering
Issued 12 January 1994 Resolved
REPAIR FRESH WATER PUMP SEAL ON THE PORT ENGINE.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Engineering
Issued 12 January 1994 Resolved
INSTALL FLAME SCREEN PAN ON FUEL FILTER FOR THE GENERATOR.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Lifesaving
Issued 14 January 1992 Resolved
CREW CONDUCT UNDERWAY EMERGENCY DRILLS TO THE SATISFACTION OF A USCG INSPECTOR NO LATER THAN 14 FEBRUARY 1992. PASSENGERS MAY NOT BE CARRIED AFTER THAT DATE UNTIL DRILLS ARE FOUND SATISFACTORY TO THE ATTENDING INSPECTOR. X
Condition: Unknown
Due 6 February 1992
Resolved 10 February 1992
Electrical
Issued 14 January 1992 Resolved
PROVIDE AND INSTALL VENT COVERS FOR FOUR (4) VENT FAN MOTORS ATTACHED TO TRANSOM IN LAZARETTE (MOTORS ARE UNPROTECTED).
Condition: Unknown
Due 6 February 1992
Resolved 10 February 1992
Construction/Loadline
Issued 14 January 1992 Resolved
PROPERLY SECURE LOOSE HAND RAILS ON STARBOARD AND PORT SIDES OF VESSEL.
Condition: Unknown
Due 6 February 1992
Resolved 10 February 1992
Lifesaving
Issued 14 January 1992 Resolved
PROVIDE PROPER MARKINGS FOR THREE (3) BUOYANT APPARATUSES (NAME OF VESSEL, AND CAPACITY IN LETTERS 1 1/2" HIGH.)
Condition: Unknown
Due 6 February 1992
Resolved 10 February 1992
Engineering
Issued 14 January 1992 Resolved
PROVIDE AND INSTALL FLAME SCREEN COVERS FOR TWO (2) RAYCOR FUEL FILTERS IN ENG ROOM.
Condition: Unknown
Due 6 February 1992
Resolved 10 February 1992
Electrical
Issued 14 January 1992 Resolved
PROVIDE PROPER MARKING FOR EMERGENCY LIGHTING (1/2" LETTER E) IN BERTHING AREAS. _x001C_ _x001C_ X
Condition: Unknown
Due 6 February 1992
Resolved 10 February 1992
Electrical
Issued 14 January 1992 Resolved
PROVIDE AND INSTALL FLUORESCENT TUBE GUARDS FOR FIXTURE IN REEFER SPACE.
Condition: Unknown
Due 6 February 1992
Resolved 10 February 1992
Electrical
Issued 12 September 1991 Resolved
INSTALL METAL COVER ON ELECTRICAL BOX MOUNTED TO OVERHEAD IN AFTER AREA OF ENGINEROOM.
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Construction/Loadline
Issued 12 September 1991 Resolved
INSTALL MISSING THROUGH HULL FITTING ON STARBOARD QUARTER OF EXTERIOR HULL.
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Construction/Loadline
Issued 12 September 1991 Resolved
REMOVE AND TREAT DRYROT IN LAZARETTE IN WAY OF DECK FRAMING, OVERHEAD FRAMING, AND AROUND PORT AND STARBOARD MAIN ENGINE EXHAUSTS ON FORWARD BULKHEAD.
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Accommodation/Occupational Safety
Issued 12 September 1991 Resolved
INSTALL INCREASED VOLUME HOLDING TANK FOR MARINE SANITATION SYSTEM, ADEQUATE TO HANDLE SEWAGE PRODUCED BY PASSENGERS AND CREW, PER USCG MARINE SAFETY MANUAL, CHAP. 18. VESSEL PERMITTED TO OPERATE WITH EXISTING SYSTEM,PROVIDED OVERBOARD VALVES SECURED WITHIN 3 MILES OF LAND.
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Electrical
Issued 12 September 1991 Resolved
REPLACE HOUSEHOLD "SJ" WIRING FOR FANS IN LAZARETTE AND "SJ" WIRING IN ENGINEROOM WITH UL APPROVED MARINE CABLE.
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Accommodation/Occupational Safety
Issued 23 January 1991 Resolved
PROVIDE LABELED RELIEF VALVE FOR THE HOT WATER HEATER SET TO RELIEVE AT 100PSI AT 210 DEGREES F.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Electrical
Issued 23 January 1991 Resolved
PROPERLY DEADEND WIRING UNDER THE BRIDGE CONSOLE.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Engineering
Issued 17 January 1990 Resolved
PROVIDE FLAME ARRESTER SHIELDS FOR FUEL OIL FILTERS IN ENGINE ROOM.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Electrical
Issued 17 January 1990 Resolved
REPAIR HOLE IN BATTERY BOX, STBD SIDE IN ENGINE ROOM.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Fire Fighting
Issued 17 January 1990 Resolved
HYDRO ALL PORTABLE DRY CHEMICAL FIRE EXTINGUISHERS. VESSEL IS NOT TO CARRY PASSENGERS UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Lifesaving
Issued 17 January 1990 Resolved
LABEL STOWAGE OF ADULT PFDS IN MAIN CABIN, LABEL STOWAGE OF CHILD PFDS, ANDREMOVE EQUIPMENT FROM PFD STOWAGE COMPARTMENT IN WHEELHOUSE.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Construction/Loadline
Issued 17 January 1990 Resolved
REPAIR OR REPLACE BROKEN WINDOW IN WHEELHOUSE, FORWARD MOST WINDOW PORT SIDE.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Electrical
Issued 17 January 1990 Resolved
PROVIDE BLANK FOR POWER DISTRIBUTION PANEL IN WHEELHOUSE (120-240 POWER PANEL).
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Engineering
Issued 17 January 1990 Resolved
GROUND FOUR FUEL TANKS.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Documentation
Issued 20 September 1989 Resolved
PROVIDE A CURRENT CERTIFICATION OF DOCUMENTATION.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Construction/Loadline
Issued 20 September 1989 Resolved
REPLACE 4 BOLTS: 2 ON CENTER AND 2 ON PORT PLATES SERVING AS SUPPORTS FOR DIVING RAMP.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Construction/Loadline
Issued 20 September 1989 Resolved
CLEAN AND TREAT ROT: 1) LAZARETTE-UNDERDECK AROUND HATCH OPENING; 2) FIRSTCOMPARTMENT FWD OF LAZARETTE-UNDERDECK, PORT SIDE OF HATCH OPENING; 3) FOREPEAK-UNDERDECK BY COLLISION BULKHEAD AND HATCH OPENING.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Fire Fighting
Issued 12 April 1989 Resolved
REMOVE ALL EXTINGUISHERS REQUIRING HYDROSTATIC TESTING AND/OR ANNUAL SERVICING.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Construction/Loadline
Issued 12 April 1989 Resolved
PROVIDE WATERTIGHT HATCHES TO FOREPEAK, LAZARETTE AND ENGINEROOM.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Engineering
Issued 12 April 1989 Resolved
DOUBLE CLAMP PEDRO FITING ON FORWARD PORT AND STARBOARD FUEL TANKS AND ATTACH PROPER GROUNDING WIRE OR STRAP.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Electrical
Issued 12 April 1989 Resolved
REMOVE UNUSED EXHAUST HOSES FROM OLD GENERATORS AND PROPERLY PLUG WATER- TIGHT BULKHEADS AND TRANSOM USING GOOD MARINE PRACTICE.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Accommodation/Occupational Safety
Issued 12 April 1989 Resolved
PROVIDE THE PRESSURE AND TEMPERATURE SETTINGS FOR THE HOT WATER HEATER. SETTINGS MUST BE AT OR BELOW 100 PSI AND 210 DEGREES FAHRENHEIT.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Accommodation/Occupational Safety
Issued 12 April 1989 Resolved
PERMANENTLY INSTALL/BRACE GALLEY REEFER COMPRESSOR LOCATED NEAR HOT WATER HEATER.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Accommodation/Occupational Safety
Issued 12 April 1989 Resolved
REMOVE OR PLUG ALL UNUSED FRESH WATER PVC PIPING NEAR REEFERS AND UNDER GALLEY.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Deck/Cargo
Issued 12 April 1989 Resolved
REPLACE SALTWATER PVC PIPING IN E/R USING GOOD MARINE PRACTICE. PIPING IS USED FOR WASHDOWN STATION AND BAIT TANK.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Construction/Loadline
Issued 12 April 1989 Resolved
INSTALL METALLIC PENETRATIONS FOR ALL NON-METALLIC PIPE RUNS THROUGH WATER-TIGHT BULKHEADS IAW 46 CFR 182.40 (PRIMARILY THE PVC BAIT TANK PIPING IN THE E/R).
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Electrical
Issued 12 April 1989 Resolved
REMOVE OR PROPERLY DEAD-END UNUSED WIRES AROUND BRIDGE CONSOLE, IN E/R AND ABOVE PASSENGER AREA (STORAGE AREA).
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Accommodation/Occupational Safety
Issued 12 April 1989 Resolved
PROPERLY GROUND ALL ELECTRICAL APPLIANCES IN THE GALLEY: TOASTER, CROCK POTFAN, ETC.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Lifesaving
Issued 12 April 1989 Resolved
PROVIDE 1 ADULT PFD.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Lifesaving
Issued 14 March 1988 Resolved
REPLACE 6 ORANGE SMOKE SIGNALS.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Navigation
Issued 14 March 1988 Resolved
REPLACE MISSING ANCHOR LIGHT.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Electrical
Issued 14 March 1988 Resolved
REPAIR ELECTRICAL CIRCUIT IN ENGINEROOM SUPPLY FOR BILGE PUMP.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Construction/Loadline
Issued 9 February 1987 Resolved
MAKE COLLISION BULKHEAD WATERTIGHT.
Condition: Unknown
Due 9 February 1987
Resolved 9 February 1987
Lifesaving
Issued 9 February 1987 Resolved
LIFE LINE ON LIFE FLOAT WASTED.
Condition: Unknown
Due 9 February 1987
Resolved 9 February 1987
Lifesaving
Issued 9 February 1987 Resolved
REPLACE 4 PFD'S.
Condition: Unknown
Due 9 February 1987
Resolved 9 February 1987
Accommodation/Occupational Safety
Issued 9 February 1987 Resolved
REPLACE BROKEN WINDOW IN PASSENGER CABIN.
Condition: Unknown
Due 9 February 1987
Resolved 9 February 1987
Construction/Loadline
Issued 25 March 1986 Resolved
TREAT ALL DRY ROTTED AREAS IN ENGINE ROOM
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Construction/Loadline
Issued 10 March 1986 Resolved
PROVIDE CAPTURE CHAIN FOR HATCH FORWARD OF WATERTIGHT COLLISION BULKHEAD
Condition: Unknown
Due 10 March 1986
Resolved 10 March 1986
Construction/Loadline
Issued 10 March 1986 Resolved
RE-ATTACH CROSSBRACE FOR ANCHOR LOCKER
Condition: Unknown
Due 10 March 1986
Resolved 10 March 1986
Engineering
Issued 10 March 1986 Resolved
CLEAN AND PRINT AFTER FUEL TANKS
Condition: Unknown
Due 10 March 1986
Resolved 10 March 1986
Electrical
Issued 10 March 1986 Resolved
BLANK OFF UNUSED OPENINGS IN CIRCUIT BREAKER BOXES LOCATED STARBOARD SIDE ENGINE ROOM AND STARBOARD SIDE BRIDGE.
Condition: Unknown
Due 10 March 1986
Resolved 10 March 1986
Construction/Loadline
Issued 10 March 1986 Resolved
MAKE COLLISION BULKHEAD WATERTIGHT.
Condition: Unknown
Due 10 March 1986
Resolved 10 March 1986
Construction/Loadline
Issued 10 March 1986 Resolved
REPLACE 6 BROKEN WINDOWS IN VESSEL SUPERSTRUCTURES.
Condition: Unknown
Due 10 March 1986
Resolved 10 March 1986
Construction/Loadline
Issued 10 March 1986 Resolved
CLEAN BILGES FOR DRYDOCKING
Condition: Unknown
Due 10 March 1986
Resolved 10 March 1986
Electrical
Issued 10 March 1986 Resolved
RENEW DRIVE BELT ON PORT GENERATOR.
Condition: Unknown
Due 10 March 1986
Resolved 10 March 1986
Accommodation/Occupational Safety
Issued 10 March 1986 Resolved
PROVIDE COVERS FOR PULLEYS AND BELTS ON AIR CONPRESSORS AND PORT GENERATOR.
Condition: Unknown
Due 10 March 1986
Resolved 10 March 1986
Engineering
Issued 10 March 1986 Resolved
LABEL ENERGENCY FUEL SHUTOFFS FOR AFTER FUEL TANKS
Condition: Unknown
Due 10 March 1986
Resolved 10 March 1986

Casualty record · 2

19 July 2011Routine · role: Involved in a Marine Casualty · 1 injured · activity 4089177
10 July 2012Routine · role: Involved in a Marine Casualty · activity 4378013
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.