MAURY USCG vessel records
← All vessels

WESTERN PRIDE

Built
1968
Last inspected
18 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD5447
Flag
UNITED STATES
Maury page id
psix-45930

Documentation record

Registered dimensions (L × B × D)75.0 ft × 22.3 ft × 4.7 ft
Registered tonnagegross 65 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOSTA MESA, CA, UNITED STATES · built 1968
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 11 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 32 inspections, each with its date, unit and type; 43 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

18 May 2026 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8343820
20 January 2026 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8276446
13 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8095652
5 November 2024 In-Service Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8024878
23 April 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7857518
17 January 2024 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7832473
24 September 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7797477
28 August 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7768373
10 April 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7666051
21 February 2023 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7633609
9 February 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7634843
19 December 2022 Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7611021
26 August 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7535756
17 June 2022 In-Service Inspection · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7485397
27 February 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7402886
12 January 2022 Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7382813
15 July 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7256966
11 June 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7222777
15 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7176795
27 May 2020 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7111735
27 May 2020 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7111781
2 April 2020 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6921879
22 January 2020 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6789740
12 February 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6610843
30 December 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6604931
8 February 2018 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6343652
4 January 2018 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6318925
18 December 2017 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6326588
29 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6314800
23 January 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6065321
13 April 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5813783
25 January 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5795276

Deficiency record · 43

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2026 Resolved
A nozzle on a vessel of more than 19.8 meters (65 feet) in length, must be of a type approved in accordance with approval series 162.027. Each combination solid stream and water spray firehose nozzle required to be approved under the provisions of this subpart must be of brass or bronze. MI observed both fire nozzles were completely plastic. Replace plastic nozzles with brass or bronze nozzles to the satisfaction of the MI within 14 days.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2026
Resolved 27 May 2026
Resolution: Vessel replaced nozzles with brass type.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2026 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, each hose must be lined commercial fire hose that conforms to the UL 19 (incorporated by reference, see 46 CFR 175.600). MI observed fire hoses were not UL 19 rated. Replace fire hoses to meet UL 19 rating within 14 days.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2026
Resolved 27 May 2026
Resolution: Vessel replaced fire hoses with UL-19 rated hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2026 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. MI observed both fuel shutoff stations were not marked. Label shutoffs to the satisfaction of the MI within 14 days.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2026
Resolved 27 May 2026
Resolution: Vessel marked fuel shut-off valves.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2026 Resolved
Each ring life buoy on a vessel must be marked with Type II retroreflective material. MI observed the retroreflective material on the forward ring life buoy was deteriorated. Replace retroreflective tape on the ring life buoy within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2026
Resolved 27 May 2026
Resolution: Vessel renewed retro-reflective tape on ring life buoy.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 May 2025 Resolved
Glass and other glazing material used in windows accessible to passengers and crew must be of material that will not break into dangerous fragments if fractured. Marine Inspector observed two windows with fractures.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 21 May 2025
Resolution: Both windows were replaced.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 November 2024 Resolved
Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. MI observed ventilation cover to Engine Room could not be fully closed to prevent air into the space. 46 CFR 181.20-35
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 17 November 2024
Resolution: Installed new vent cover.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 April 2024 Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: Light. The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. Several water lights had incorrect batteries installed. Install appropriate batteries iaw. light requirements. 46 CFR 180.175(f)(4) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 8 May 2024
Resolution: All batteries replaced with new and appropriate batteries.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 April 2024 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Smoke detector in mess deck accommodation space missing. Once replaced, prove proper operation of entire interconnected detection system. 46 CFR 181.405(c) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 9 May 2024
Resolution: Missing detector replaced and system working properly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 April 2024 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Escape hatch from galley to upper deck not marked.
Action required: 10 - Deficiency Rectified
Due 23 April 2024
Resolved 23 April 2024
Resolution: Escape properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2024 Resolved
Each life jacket carried on a vessel on oceans route must have a life jacket light. (03) life jacket lights had dead batteries. Batteries. Replace batteries and prove proper operation. 46 CFR 180.75
Action required: 10 - Deficiency Rectified
Due 23 April 2024
Resolved 23 April 2024
Resolution: Dead batteries replaced.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 23 April 2024 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Post emergency instructions at operating station. 46 CFR 185.510
Action required: 10 - Deficiency Rectified
Due 23 April 2024
Resolved 23 April 2024
Resolution: Instructions posted at operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 September 2023 Resolved
46 CFR 182.200 - Propulsion machinery must be suitable in type and design for propulsion requirements of the hull. Vessel was unable to clutch into the main engine while underway.
Action required: 60 - Rectify deficiencies prior to movement
Due 25 September 2023
Resolved 25 September 2023
Resolution: completed sat repairs and sea trial
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 February 2023 Resolved
A pre engineered fixed gas fire extinguishing system must: automatically shutdown all engines that draw in take are from within the protected space. Vessel fixed system did not shut down engines.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 February 2023
Resolved 21 February 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 February 2023 Resolved
On a vessel more than 65 feet the fire pump must be not less than 60 psi at the pump outlet and fitted with a pressure gauge. vessel fire pump pressure gauge was not functioning
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2023
Resolved 20 March 2023
Resolution: Received photo from operator of operable pressure gauge and adequate pressure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 February 2022 Resolved
Replace and/or repair two damaged ring life buoys. A vessel of more than 65 feet in length must carry a minimum of three life buoys of not less than 24 inches in diameter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2021 Resolved
At each initial and subsequent inspection for certification and reinspection the marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory and that it is fit for the service intended. MI found steering ram mounting plate is cracked and flexing under load. Vessel is to replace mounting plate to the satisfaction of the attending marine inspector. 46CFR 176.25-35(a)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 6 May 2021
Resolution: Received video of operation of steering ram with new mounting plate installed. All satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 27 May 2020 Resolved
MI found non serviceable lights on all child life jackets. Due to approved routes on COI, vessel needs to provide serviceable lights on all life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 4 June 2020
Resolution: vessel replaced batteries in all child life jacket lights and at this time they all function as designed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 May 2020 Resolved
MI found Galley high level alarm not operating on the bridge. Vessel needs to make repairs and prove alarm works as designed and to Regulation 46CFR182.425
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 4 June 2020
Resolution: MI verified high level alarm works for the galley bilge compartment. Witnessed audio and visual indicators on the alarm panel.
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 27 May 2020 Resolved
MI found Port and starboard navigational light to be under sized for the vessel. Vessel needs to remove unapproved lights and install UL1104 navigational lights with correct lenses.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 4 June 2020
Resolution: Vessel installed UL1104 navigational lights and are currently burning bright with its correct navigational color.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 27 May 2020 Resolved
MI found 3 foot section of top rail missing along the starboard side. Section was removed for treatment of wood rot. Vessel needs to provide rail member with adequate strength to meet regulation. 46CFR177.900
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 4 June 2020
Resolution: Vessel replaced rotted wood and install treated and coated member into its place. Rail pasted weight test. 46CFR177.900
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 April 2020 Resolved
Due to COVID-19 circumstances beyond the control of the vessel, the vessel is unable to meet the time frame required by 46 CFR 176.600(c)(1). Vessel is allowed 90 days to continue operations in accordance with the COI, and is required to make itself available for inspection prior to 02JUL2020.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 July 2020
Resolved 4 June 2020
Resolution: Vessel completed satisfactory annual inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2019 Resolved
Main Steering Gear: Steering linkage connecting the dual rudders was found to be severely wasted and broken (material failure), current condition poses risk of steering failure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2019
Resolution: Installed new steering linkage at South Coast Shipyard in Newport Beach, CA.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 February 2019 Resolved
Charts and Pubications: Current/Up to Date Navigation charts were not onboard the vessel. To further explain, there were no paper charts onboard the vessel and the only means of navigation was a single electronic chart system/display. The chart card installed in the electronic chart system/display was produced in CY2008 and had not been updated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2019
Resolution: NOAA Paper Charts placed onboard the vessel.
Engineering › Bilge Water Management System › Valve
Issued 4 January 2018 Resolved
Make arrangements for bilge suction isolation valve for forepeak to be operable at the weather deck 46 CFR 182.25-5(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 February 2018
Resolved 27 May 2020
Resolution: MI witnessed service operation of remote bilge valve.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 January 2018 Resolved
Remove from the vessel and destroy 4 unservicable adult lifejackets.
Due 4 February 2018
Resolved 4 January 2018
Resolution: Corrected during the inspection: the vessel had additional lifejackets on board.
Construction/Loadline › Hull › Hull Plating
Issued 13 April 2016 Resolved
Remove all rotten wood in Enigine room as indicated and have ready for inspection upon removal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2016
Construction/Loadline › Hull › Transverse Frame
Issued 13 April 2016 Resolved
Remove all rotten wood on transom as indicated on both inside and out and leave open for inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2016
Resolution: Area was ready for inspection.
Construction/Loadline › Hull › Hull Plating
Issued 13 April 2016 Resolved
On portside from about frame 30 to 35 on the freeboard and around the waterline to the chine, remove all paint and cualk to good wood and leave open for inspection
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2016
Resolution: Area was ready for inspection.
Construction/Loadline › Hull › Hull Plating
Issued 13 April 2016 Resolved
On starboard side about 30'aft of hull, remove paint and cualk to good wood and leave open for inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2016
Resolution: Area was ready for inspection.
Construction/Loadline › Hull › Bottom Plating
Issued 13 April 2016 Resolved
On starboard side on under body at the chine, remove paint and cualk to good wood and leave open for inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2016
Resolution: Area was ready for inspection.
Accommodation/Occupational Safety › Potable Water System › General
Issued 13 April 2016 Resolved
Starboard side galley, replace broken drain line.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2016
Resolution: Drain line was replaced.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 13 April 2016 Resolved
Repair/Replace starboard aft cleat mount.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2016
Construction/Loadline › Hull › Stiffener
Issued 13 April 2016 Resolved
Replace as original both inboard and outboard engine bed frames.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2016
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 13 April 2016 Resolved
Repair forward eingine room bulkhead around bilge pipe and make water tight.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2016
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 13 April 2016 Resolved
Repair/Replace engine room overhead/main deck on portside.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2016
Construction/Loadline › Structures › Machinery Space Opening
Issued 13 April 2016 Resolved
Repair/Replace engine room combing frames.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2016
Construction/Loadline › Hull › Side Shell
Issued 13 April 2016 Resolved
Repair/Replace hull around bilge overboard on starboard side.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2016
Construction/Loadline › Hull › Hull Plating
Issued 13 April 2016 Resolved
Re-cualk hull as indicated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2016
Construction/Loadline › Hull › Bottom Plating
Issued 13 April 2016 Resolved
Remove to good wood, plank on under water body at frame 13 from aft, starboard side. Repair/Replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2016
Documentation › Logs/Records › Logbook (official)
Issued 25 January 2016 Resolved
Embarkation and debarkation passenger counts were not logged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 24 March 2016
Lifesaving › Lifefloat › Float Free
Issued 25 January 2016 Resolved
Spacers not provided between life floats
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 24 March 2016
Operations/Management › Passenger Operations › Safety Orientation
Issued 25 January 2016 Resolved
Passenger safety orientation was not published
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 24 March 2016
Electrical › Electric Generation Source (service) › Generator
Issued 25 January 2016 Resolved
Minor leak on front cover of generator prime mover
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 24 February 2016

Ownership record