← All vessels
WESTERN PRIDE
Passenger (Inspected) · Passenger Ship class · Built 1960s · USCG Southwest District (CGD-SW) · Other hulls named WESTERN PRIDE
WESTERN PRIDE is a 1968 passenger vessel (inspected). The Coast Guard has recorded 94 inspections since 1984, most recently in May 2026, along with 100 deficiencies and 2 casualty investigations between 2013 and 2018.
Records from 1984 to 2026. Most recent: inspection, 18 May 2026.
- Built
- 1968
- Last inspected
- 18 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 100 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2013–2018
Identity
515063
WDD5447
45930
Flag
UNITED STATES
367158550
Maury page id
psix-45930
Inspections, by type
…with no type recorded10
Years with a record
38 calendar years (1984–2026)
The 94 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)75.0 ft × 22.3 ft × 4.7 ft
Registered tonnagegross 65 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · COSTA MESA, CA, UNITED STATES · built 1968
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 11 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD5447MMSI 367158550 · active · compulsorily equipped · granted 10 December 2016, expires 4 January 2027
WU4506MMSI not assigned · expired · compulsorily equipped · granted 13 January 1997, cancelled 17 March 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 94
18 May 2026
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8343820
20 January 2026
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8276446
13 May 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8095652
5 November 2024
In-Service Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8024878
23 April 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7857518
17 January 2024
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7832473
24 September 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7797477
28 August 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7768373
10 April 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7666051
21 February 2023
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7633609
9 February 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7634843
19 December 2022
Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7611021
26 August 2022
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7535756
17 June 2022
In-Service Inspection · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7485397
27 February 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7402886
12 January 2022
Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7382813
15 July 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7256966
11 June 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7222777
15 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7176795
27 May 2020
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7111735
27 May 2020
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7111781
2 April 2020
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6921879
22 January 2020
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6789740
12 February 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6610843
30 December 2018
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6604931
8 February 2018
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6343652
4 January 2018
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6318925
18 December 2017
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6326588
29 November 2017
Administrative Inspection
Administrative · Navigation Center · Activity 6314800
23 January 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6065321
13 April 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5813783
25 January 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5795276
20 June 2012
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4351115
7 February 2012
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4223260
8 March 2010
Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3714904
21 January 2010
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3658477
8 December 2008
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3376262
17 April 2008
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3160242
7 January 2008
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3114531
4 April 2007
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2898370
29 October 2006
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2810047
25 April 2006
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2594067
30 March 2006
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2598726
11 February 2005
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2290942
20 January 2005
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2272809
20 April 2004
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2047443
27 January 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1991420
7 January 2003
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1726580
11 October 2002
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1688536
9 April 2002
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1605050
15 January 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1482454
31 March 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 151362
11 January 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369969
12 May 2000
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1361479
3 January 2000
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1438948
28 February 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1470500
14 January 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 809550
4 January 1999
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397054
1 June 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 792873
8 May 1998
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1381214
26 February 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 785635
5 January 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1416621
6 January 1997
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1356052
17 April 1996
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1407655
22 January 1996
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1357454
4 October 1995
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 880356
22 September 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1416186
23 January 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 870225
7 December 1994
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1377314
25 October 1994
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1173700
3 February 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1165277
25 January 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1162232
27 October 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 838931
26 April 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 829973
18 February 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1147010
25 January 1993
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 826100
11 February 1992
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 956750
9 April 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 927499
12 March 1991
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 910272
21 February 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1213935
6 December 1990
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 901013
22 February 1990
COI Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 921158
11 January 1990
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1220106
27 February 1989
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1351529
15 November 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 893364
11 March 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1031985
29 February 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1333377
7 December 1987
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1310404
2 March 1987
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1007969
3 December 1986
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1331973
4 March 1986
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 995839
11 December 1985
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1302944
4 March 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1289140
5 December 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 977057
Deficiency record · 100
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2026
Resolved
A nozzle on a vessel of more than 19.8 meters (65 feet) in length, must be of a type approved in accordance with approval series 162.027. Each combination solid stream and water spray firehose nozzle required to be approved under the provisions of this subpart must be of brass or bronze. MI observed both fire nozzles were completely plastic. Replace plastic nozzles with brass or bronze nozzles to the satisfaction of the MI within 14 days.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2026
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, each hose must be lined commercial fire hose that conforms to the UL 19 (incorporated by reference, see 46 CFR 175.600). MI observed fire hoses were not UL 19 rated. Replace fire hoses to meet UL 19 rating within 14 days.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2026
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. MI observed both fuel shutoff stations were not marked. Label shutoffs to the satisfaction of the MI within 14 days.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2026
Resolved
Each ring life buoy on a vessel must be marked with Type II retroreflective material. MI observed the retroreflective material on the forward ring life buoy was deteriorated. Replace retroreflective tape on the ring life buoy within 14 days.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 May 2025
Resolved
Glass and other glazing material used in windows accessible to passengers and crew must be of material that will not break into dangerous fragments if fractured. Marine Inspector observed two windows with fractures.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 November 2024
Resolved
Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. MI observed ventilation cover to Engine Room could not be fully closed to prevent air into the space. 46 CFR 181.20-35
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 April 2024
Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: Light. The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. Several water lights had incorrect batteries installed. Install appropriate batteries iaw. light requirements.
46 CFR 180.175(f)(4) 16c
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 April 2024
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Smoke detector in mess deck accommodation space missing. Once replaced, prove proper operation of entire interconnected detection system. 46 CFR 181.405(c) 16c
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 April 2024
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Escape hatch from galley
to upper deck not marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2024
Resolved
Each life jacket carried on a vessel on oceans route must have a life jacket light. (03) life jacket lights had dead batteries. Batteries. Replace batteries and prove proper operation. 46 CFR 180.75
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 23 April 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Post emergency instructions at operating station.
46 CFR 185.510
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 September 2023
Resolved
46 CFR 182.200 - Propulsion machinery must be suitable in type and design for propulsion requirements of the hull. Vessel was unable to clutch into the main engine while underway.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 February 2023
Resolved
A pre engineered fixed gas fire extinguishing system must: automatically shutdown all engines that draw in take are from within the protected space. Vessel fixed system did not shut down engines.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 February 2023
Resolved
On a vessel more than 65 feet the fire pump must be not less than 60 psi at the pump outlet and fitted with a pressure gauge. vessel fire pump pressure gauge was not functioning
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 February 2022
Resolved
Replace and/or repair two damaged ring life buoys. A vessel of more than 65 feet in length must carry a minimum of three life buoys of not less than 24 inches in diameter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2021
Resolved
At each initial and subsequent inspection for certification and reinspection the marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory and that it is fit for the service intended. MI found steering ram mounting plate is cracked and flexing under load. Vessel is to replace mounting plate to the satisfaction of the attending marine inspector. 46CFR 176.25-35(a)
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 27 May 2020
Resolved
MI found non serviceable lights on all child life jackets. Due to approved routes on COI, vessel needs to provide serviceable lights on all life jackets.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 May 2020
Resolved
MI found Galley high level alarm not operating on the bridge. Vessel needs to make repairs and prove alarm works as designed and to Regulation 46CFR182.425
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 27 May 2020
Resolved
MI found Port and starboard navigational light to be under sized for the vessel. Vessel needs to remove unapproved lights and install UL1104 navigational lights with correct lenses.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 27 May 2020
Resolved
MI found 3 foot section of top rail missing along the starboard side. Section was removed for treatment of wood rot. Vessel needs to provide rail member with adequate strength to meet regulation. 46CFR177.900
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 April 2020
Resolved
Due to COVID-19 circumstances beyond the control of the vessel, the vessel is unable to meet the time frame required by 46 CFR 176.600(c)(1). Vessel is allowed 90 days to continue operations in accordance with the COI, and is required to make itself available for inspection prior to 02JUL2020.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2019
Resolved
Main Steering Gear: Steering linkage connecting the dual rudders was found to be severely wasted and broken (material failure), current condition poses risk of steering failure.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 February 2019
Resolved
Charts and Pubications: Current/Up to Date Navigation charts were not onboard the vessel. To further explain, there were no paper charts onboard the vessel and the only means of navigation was a single electronic chart system/display. The chart card installed in the electronic chart system/display was produced in CY2008 and had not been updated.
Engineering › Bilge Water Management System › Valve
Issued 4 January 2018
Resolved
Make arrangements for bilge suction isolation valve for forepeak to be operable at the weather deck 46 CFR 182.25-5(d)
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 January 2018
Resolved
Remove from the vessel and destroy 4 unservicable adult lifejackets.
Construction/Loadline › Hull › Hull Plating
Issued 13 April 2016
Resolved
Remove all rotten wood in Enigine room as indicated and have ready for inspection upon removal.
Construction/Loadline › Hull › Transverse Frame
Issued 13 April 2016
Resolved
Remove all rotten wood on transom as indicated on both inside and out and leave open for inspection.
Construction/Loadline › Hull › Hull Plating
Issued 13 April 2016
Resolved
On portside from about frame 30 to 35 on the freeboard and around the waterline to the chine, remove all paint and cualk to good wood and leave open for inspection
Construction/Loadline › Hull › Hull Plating
Issued 13 April 2016
Resolved
On starboard side about 30'aft of hull, remove paint and cualk to good wood and leave open for inspection.
Construction/Loadline › Hull › Bottom Plating
Issued 13 April 2016
Resolved
On starboard side on under body at the chine, remove paint and cualk to good wood and leave open for inspection.
Accommodation/Occupational Safety › Potable Water System › General
Issued 13 April 2016
Resolved
Starboard side galley, replace broken drain line.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 13 April 2016
Resolved
Repair/Replace starboard aft cleat mount.
Construction/Loadline › Hull › Stiffener
Issued 13 April 2016
Resolved
Replace as original both inboard and outboard engine bed frames.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 13 April 2016
Resolved
Repair forward eingine room bulkhead around bilge pipe and make water tight.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 13 April 2016
Resolved
Repair/Replace engine room overhead/main deck on portside.
Construction/Loadline › Structures › Machinery Space Opening
Issued 13 April 2016
Resolved
Repair/Replace engine room combing frames.
Construction/Loadline › Hull › Side Shell
Issued 13 April 2016
Resolved
Repair/Replace hull around bilge overboard on starboard side.
Construction/Loadline › Hull › Hull Plating
Issued 13 April 2016
Resolved
Re-cualk hull as indicated.
Construction/Loadline › Hull › Bottom Plating
Issued 13 April 2016
Resolved
Remove to good wood, plank on under water body at frame 13 from aft, starboard side. Repair/Replace in kind.
Documentation › Logs/Records › Logbook (official)
Issued 25 January 2016
Resolved
Embarkation and debarkation passenger counts were not logged.
Lifesaving › Lifefloat › Float Free
Issued 25 January 2016
Resolved
Spacers not provided between life floats
Operations/Management › Passenger Operations › Safety Orientation
Issued 25 January 2016
Resolved
Passenger safety orientation was not published
Electrical › Electric Generation Source (service) › Generator
Issued 25 January 2016
Resolved
Minor leak on front cover of generator prime mover
Fire Fighting › Structural - B Class Divisions › Windows
Issued 7 February 2012
Resolved
Replace cracked window (port side aft) in way of galley at next scheduled drydock (April 2012).
Fire Fighting › Nozzles › Type
Issued 7 February 2012
Resolved
Provide fire nozzles in accordance with 46 CFR 181.320(d).
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 February 2012
Resolved
Rejected (7) child-size PFDs due to deteriorated condition, missing straps, tears, etc.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 7 January 2008
Resolved
It has been determined that your vessel's arrangement is such that an unconscious person cannot be recovered from the water without additional equipment. Provide rescue boat or platform or other suitable arrangement IAW 46CFR180.210.
Engineering › Sea-water System (primary cooling) › Piping
Issued 20 January 2005
Resolved
Sea water cooling for SSG is provided via the bait pump and PVC piping materials. Install proper metallic piping during next dry dock (4/30/2006) and provide low flow sensor in sea water cooling line to exhaust NLT 2/20/2005.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 7 January 2003
Resolved
Provide service report for Fixed Fire Ext System.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 January 2003
Resolved
Replace two of three ring buoys, worn/deteriorated.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 7 January 2003
Resolved
Provide proof of current EPIRB registration.
Accommodation/Occupational Safety › Medical/First Aid
Issued 15 January 2002
Resolved
Expired items in first-aid kit; corrected on the spot. LEGACY COMPONENT DESC: Medicine Chest
Unknown
Issued 12 May 2000
Resolved
Replace deck boards on STBD side, next to STBD engine room's hatch.
Unknown
Issued 3 January 2000
Resolved
PROVIDE DOCUMENTED PROOF OF REQUIRED TRAINING (6O MINUTES FOR SUPERVISORS) FOR ALL CREWMEMBERS ON VESSEL IAW EMPLOYEE ASSISTANCE PROGRAM (EAP) REQUIREMENTS.
Lifesaving
Issued 22 January 1996
Resolved
Provide EPIRB prior to operating on oceans route.
Lifesaving
Issued 22 September 1995
Resolved
Provide a 2" band of retroreflective tape completely around each side of all lifefloats. Each lifefloat must have 4 bands of tape.
Lifesaving
Issued 22 September 1995
Resolved
Provide 10 additional adult type 1 PFD's. The total number of persons on board is limited to 115 until additional PFD's are provided on board.
Engineering
Issued 23 January 1995
Resolved
REPLACE EMERGENCY FUEL SHUT-OFF VALVE ON AFT STARBOARD TANK
Accommodation/Occupational Safety
Issued 25 January 1994
Resolved
INSTALL MEANS OF LOCKING MSD OVERBOARD DISCHARGE VALVES.
Accommodation/Occupational Safety
Issued 25 January 1994
Resolved
ENSURE THAT FLOOR PANEL AT BOTTOM OF LADDER UNDER WHEELHOUSE IS SOLID.
Navigation
Issued 25 January 1994
Resolved
INSTALL LOCK NUTS, DOUBLE NUTS, OR COTTER PINS FOR STEERING GEAR CONNECTIONS.
Lifesaving
Issued 25 January 1994
Resolved
PROVIDE ON BOARD 3 ADDITIONAL ADULT PFD'S PRIOR TO CARRYING MORE THAN 119 PASSENGERS.
Engineering
Issued 25 January 1994
Resolved
INSTALL FLAME SCREEN ON STBD FUEL FILTER.
Construction/Loadline
Issued 25 January 1994
Resolved
INSTALL DISCHARGE HOSE OF SUITABLE LENGTH ON PORTABLE HAND PUMP.
Fire Fighting
Issued 25 January 1994
Resolved
PROVE PROPER OPERATION OF FIRE PUMP PRESSURE GAUGE.
Lifesaving
Issued 25 January 1994
Resolved
REPLACE BROKEN WATERLIGHT ON LIFE FLOAT PRIOR TO OPERATING AFTER DARK.
Fire Fighting
Issued 25 January 1993
Resolved
REPAIR OR REPLACE THE PRESSURE GAUGE ON THE FIRE PUMP.
Construction/Loadline
Issued 25 January 1993
Resolved
REPLACE SEIZED GATE VALVE AT MANIFOLD FOR FORE PEAK BILGE AND PROVE PROPER OPERATION OF THE LINE OR REMOVE THE ENTIRE LINE AND REPAIR PENETRATIONS IN BULKHEADS.
Construction/Loadline
Issued 25 January 1993
Resolved
PROVE PROPER OPERATION OF THE BILGE SYSTEM FLOAT SWITCH ON THE FORWARD BULKHEAD OF THE ENGINEROOM ON THE STARBOARD SIDE.
Construction/Loadline
Issued 25 January 1993
Resolved
PROVIDE ADEQUATE LENGTH (APPROXIMATELY 10 FEET) OF DISCHARGE HOSE FOR THE PORTABLE HAND PUMP.
Documentation
Issued 25 January 1993
Resolved
PRIOR TO COMPLETION OF THE NEXT ROUTINE DRYDOCKING, INSTALL DRAFT MARKS OR LOADING MARKS AS DESCRIBED IN 46 CFR 185.30-3. (LOCATION TO AGREE WITH MAXIMUM DRAFT INDICATED ON THE VESSEL'S STABILITY LETTER.)
Engineering
Issued 25 January 1993
Resolved
INSTALL 30/30 SCREEN ON FUEL VENTS FOR BOTH FORWARD FUEL TANKS.
Fire Fighting
Issued 11 February 1992
Resolved
PROVIDE PRESSURE GAUGE FOR FIRE PUMP.
Electrical
Issued 11 February 1992
Resolved
DOUBLE CLAMP RAW WATER HOSE FOR GENERATOR COOLING.
Engineering
Issued 11 February 1992
Resolved
SECURE BRACKET FOR STARBOARD FUEL TANK SHUT-OFF IN ENGINE ROOM.
Engineering
Issued 11 February 1992
Resolved
REPLACE PORT FUEL TANK VENT FLAME SCREEN.
Engineering
Issued 11 February 1992
Resolved
PROPERLY SECURE STARBOARD FUEL TANK VENT SCREEN.
Navigation
Issued 11 February 1992
Resolved
PROVIDE TIDE TABLE AND TIDAL CURRENT TABLE PUBLICATIONS.
Construction/Loadline
Issued 11 February 1992
Resolved
INSTALL CAPTURE CHAINS FOR WEATHER TIGHT HATCHES ON MAIN DECK (FORE AND AFT).
Fire Fighting
Issued 11 February 1992
Resolved
PROVIDE PROPER BRACKET FOR SPARE FIRE EXTINGUISHERS IN PILOT HOUSE.
Accommodation/Occupational Safety
Issued 11 February 1992
Resolved
PROPERLY SECURE RAIL TO POST AT TRANSOM.
Electrical
Issued 11 February 1992
Resolved
REPLACE BROKEN CIRCUIT BREAKER ON MAIN ELECTRICAL PANEL IN ENGINE ROOM.
Electrical
Issued 11 February 1992
Resolved
PROVIDE A MEANS TO DISCONNECT THE SHORE-TIE CABLE FROM THE VESSEL ON OR NEAR THE MAIN DISTRIBUTION PANEL.
Electrical
Issued 11 February 1992
Resolved
REMOVE WIRE NUTS AND PROPERLY REWIRE WIRES IN GALLEY OVERHEAD AND BRIDGE CONSOLE.
Accommodation/Occupational Safety
Issued 11 February 1992
Resolved
REMOVE GREASE FROM SCREEN ABOVE GRILL IN GALLEY
Accommodation/Occupational Safety
Issued 11 February 1992
Resolved
INSTALL PROPER FLUSHING SYSTEM FOR MSD TO ELIMINATE CONSTANT FLUSH SYSTEM.
Electrical
Issued 11 February 1992
Resolved
LABEL CIRCUIT BREAKER PANEL (MAIN ELECTRICAL) IN ENGINE ROOM FORWARD BULKHEAD.
Engineering
Issued 21 February 1991
Resolved
PROVE PROPER OPERATION OF STARBOARD ENGINE RPM GAUGE.
Engineering
Issued 21 February 1991
Resolved
PROVIDE LAGGING FOR PORT AND STBD MAIN ENGINE EXHAUST.
Electrical
Issued 21 February 1991
Resolved
PROPERLY DEADEND OR REMOVE WIRE BELOW PORT SIDE BATTERY CHARGER.
Electrical
Issued 21 February 1991
Resolved
PROVE PROPER OPERATION OF ENGINE ROOM EMERGENCY LIGHT.
Electrical
Issued 21 February 1991
Resolved
PROPERLY LINE PORT SIDE BATTERY BOX.
Deck/Cargo
Issued 21 February 1991
Resolved
REMOVE OIL/WATER FROM FOREPEAK BILGE.
Electrical
Issued 22 February 1990
Resolved
PROVIDE AND INSTALL COVER PLATE FOR 4-GANG OUTLET BOX ON FORWARD BULKHEAD, PORT SIDE OF GALLEY.
Construction/Loadline
Issued 22 February 1990
Resolved
STENCIL TOPSIDE OF EMERGENCY ESCAPE HATCH "EMERGENCY EXIT, KEEP CLEAR" IN ONE INCH HIGH LETTERS.
Accommodation/Occupational Safety
Issued 22 February 1990
Resolved
REMOVE OR PERMANENTLY MOUNT THE FOLLOWING GALLEY EQUIPMENT: A) COFFEE MAKERS (2) B) HOT PLATES (2) C) TELEVISION
Accommodation/Occupational Safety
Issued 27 February 1989
Resolved
PROVIDE FAUCET HANDLES FOR WASH BASINS IN BOTH HEADS.
Engineering
Issued 27 February 1989
Resolved
PROVIDE CONDUCTOR FOR PORT SIDE FUEL TANK FILL TUBE IAW 46 CFR 182.20-30(D)
Engineering
Issued 29 February 1988
Resolved
REPAIR AND PROVE PROPER OPERATION OF BOTH MAIN ENGINE TACHOMETERS.
Navigation
Issued 2 March 1987
Resolved
REPAIR AND PROVE PROPER OPERATION OF STERN LIGHT.
Casualty record · 2
16 June 2013Routine · role: Involved in a Marine Casualty · activity 4634467
30 December 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6604931
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.