Records from 1986 to 2002. Most recent: inspection, 5 June 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 31
5 June 2002
Administrative Inspection · COI Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1628015
1 August 2001
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 772621
24 May 2001
Re-Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1432546
15 June 2000
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1430876
14 September 1999
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 784600
19 May 1999
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1372631
9 April 1999
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1372630
15 July 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1435955
5 September 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 945695
13 August 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1089387
30 July 1996
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1404218
15 May 1996
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1353926
15 June 1995
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1187671
28 July 1994
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1432825
21 June 1994
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1414314
26 October 1993
Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 841991
18 May 1993
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 841892
1 July 1992
Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 951169
5 July 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1233796
3 June 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 914975
3 June 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1229964
23 January 1991
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 905589
17 May 1990
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 934822
20 July 1989
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1338234
12 June 1989
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 891351
15 May 1989
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1351381
11 October 1988
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1198395
17 May 1988
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1042691
21 May 1987
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1003349
17 April 1987
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1314841
24 April 1986
Re-Inspection · Credit Drydock
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 992905
Lifesaving › Buoyant Apparatus › Serviceable
Issued 5 June 2002
Resolved
Buoyant apparatus found worn beyond possible repair. Replace prior to operating with more than 6 passengers for hire with an approved inflatable buoyant apparatus of sufficient size to carry 100% of the people on board. No COI will be issued until this item is satisfied.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2014
Resolution: Vessel is out of service and will need to conduct a complete COI if owner request to be certificated again. This deficiency is cleared for Administration reasons.
Lifesaving › Lifejacket/PFD (Type I)
Issued 5 June 2002
Resolved
Rejected 3 adult lifejackets. Total number of people on board reduce from 18 to 15 until rejected lifejackets are replaced with approved type. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2002
Resolution: Life jackets ordered.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 5 June 2002
Resolved
Adult and child lifejackets must be stowed in separate locations. Lifejacket storage areas must be properly stenciled with accurate number of lifejackets. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2002
Resolved 4 November 2014
Resolution: Vessel is out of service and will need to conduct a complete COI if owner request to be certificated again. This deficiency is cleared for Administration reasons.
Navigation › Piloting/Steering › Marine Charts
Issued 5 June 2002
Resolved
Provide accurate up to date charts for areas of intended navigation and current copy of Nav Rules LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 28 June 2002
Resolved 4 November 2014
Resolution: Vessel is out of service and will need to conduct a complete COI if owner request to be certificated again. This deficiency is cleared for Administration reasons.
Operations/Management › Drills/Instruction
Issued 5 June 2002
Resolved
Master has not been conducting monthly drills. Will begin monthly drills and instruction.
Action required: 705 - Other - as specified
Due 5 June 2002
Resolved 5 June 2002
Resolution: Will begin this date.
Operations/Management › Passenger Operations
Issued 5 June 2002
Resolved
Due to insufficient rail height, no passengers are allowed on the flying bridge. A sign or stencil must be posted on ladder to flying bridge prohibiting passengers.
Action required: 705 - Other - as specified
Due 5 June 2002
Resolved 6 June 2002
Resolution: Stencil placed on ladder to flying bridge.
Engineering › Fuel Oil Service System › Valve
Issued 5 June 2002
Resolved
Starboard propulsion engine remote fuel shut off valve failed to operate. Prove proper operation prior to carrying passengers for hire. LEGACY COMPONENT DESC: Valve, Control
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2002
Resolved 4 November 2014
Resolution: Vessel is out of service and will need to conduct a complete COI if owner request to be certificated again. This deficiency is cleared for Administration reasons.
Lifesaving
Issued 24 May 2001
Resolved
EPIRB hydro expired Dec 2000.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Lifesaving
Issued 19 May 1999
Resolved
Hold fire and man overboard drills in the presence of marine inspector prior to carrying 7 or more passengers.
Condition: Unknown
Due 15 July 1999
Resolved 16 July 1999
Construction/Loadline
Issued 19 May 1999
Resolved
Add hose to hand bilge pump to reach all bilges and allow bailing overboard.
Condition: Unknown
Due 15 July 1999
Resolved 16 July 1999
Construction/Loadline
Issued 19 May 1999
Resolved
Add high level bilge audible alarm to operating station.
Condition: Unknown
Due 15 July 1999
Resolved 16 July 1999
Lifesaving
Issued 19 May 1999
Resolved
Add ladder for recovering man overboard prior to carrying 7 or more passengers.
Condition: Unknown
Due 15 July 1999
Resolved 16 July 1999
Construction/Loadline
Issued 19 May 1999
Resolved
Add manually operated valve on thru hull fitting associated with after bilge pump piping thru transom.
Condition: Unknown
Due 15 July 1999
Resolved 16 July 1999
Documentation
Issued 19 May 1999
Resolved
Provide proof of random drug testing enrollment for all crew prior to taking passengers.
Condition: Unknown
Due 15 July 1999
Resolved 16 July 1999
Fire Fighting
Issued 19 May 1999
Resolved
Prove proper operation of automatic engine shutdown upon discharge of fixedF/E in E-room prior to carrying 7 or more passengers.
Condition: Unknown
Due 15 July 1999
Resolved 20 May 1999
Construction/Loadline
Issued 30 July 1996
Resolved
PROVIDE KEEPER CHAIN OR WIRE ROPE TO RETAIN FLUSH DECK HATCH LEADING TO LAZARETTE.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Navigation
Issued 30 July 1996
Resolved
REPLACE MISSING ANCHOR BOLT WHERE STEERING RAM BRACKET MOUNTS TO THWART.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Navigation
Issued 30 July 1996
Resolved
REPLACE WORN STARBOARD STRUT CUTLASS BEARING.
Condition: Unknown
Due 30 September 1996
Resolved 6 September 1996
Construction/Loadline
Issued 30 July 1996
Resolved
REPLACE MISSING BOLT IN SECOND TRANSVERSE DECK FRAME ON STBD SIDE FORWARD OF TRANSOM; MISSING BOLT IS ONE OF TWO USED TO MAKE LAP JOINT CONNECTING NEW AND OLD FRAMING MEMBERS.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Documentation
Issued 18 May 1993
Resolved
PROVIDE A COPY OF STABILITY LETTER OR PROOF OF SISTER VESSEL WITH VALID STABILITY LETTER FOR EXPOSED ROUTES.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Electrical
Issued 15 May 1989
Resolved
REPLACE WIRENUTS THROUGH-OUT ELECTRICAL INSTALLATION WITH COMPRESSION TYPE FITTINGS.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Lifesaving
Issued 21 May 1987
Resolved
PROVIDE ONE (01) ADDITIONAL RING LIFE BUOY (CONSTRUCTED IN ACCORDANCE WITH SUBPART 160.050 OF 46 CFR). THIS ADDITIONAL BUOY NEED NOT HAVE A WATER LIGHT ATTACHED, BUT MUST BE PROVIDED PRIOR TO CARRYING MORE THAN 12 PASSENGERS (14 TOTAL PERSONS) ON A COASTWISE VOYAGE.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987