Records from 2016 to 2025. Most recent: inspection, 8 October 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 23
8 October 2025
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8249266
24 March 2025
Security Breach
Type not classified · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8102315
21 November 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8037962
18 January 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7850555
11 October 2023
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7806077
21 November 2022
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7597976
13 October 2022
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7566160
13 January 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7379336
2 September 2021
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7314470
26 August 2021
Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7297199
26 August 2021
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7298191
7 December 2020
Periodic Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7103399
2 November 2020
Drydock Extension · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7087026
14 October 2020
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7077704
22 January 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6893355
8 January 2019
Annual Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6606512
13 September 2018
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6540485
13 October 2017
MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6286854
21 June 2017
Excursion Permit
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6184343
30 January 2017
Excursion Permit
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6080812
17 January 2017
Annual Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6072687
23 August 2016
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5981136
25 January 2016
Plan Review (Other than "T") · Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5795775
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 21 November 2024
Resolved
02- Conduct required drills prior to operating the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2024
Resolved 11 December 2024
Resolution: Drills conducted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 November 2024
Resolved
01- Conduct annual and monthly servicing of all portable fire extinguishers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2024
Resolution: Completed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 November 2024
Resolved
Crop and renew fire station #1 stand pipe.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2024
Resolution: Stand pipe cropped and renewed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 November 2024
Resolved
04- Provide position information on VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 December 2024
Resolution: Radio programmed for position information.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 November 2024
Resolved
05- Replace aft mast headlight
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 December 2024
Resolution: Light replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 November 2024
Resolved
Repair oil leak on the #1 generator exhaust manifold.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 December 2024
Resolution: Exhaust manifold repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2024
Resolved
07- Repair junction box on stbd side 02 deck light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2024
Resolved 11 December 2024
Resolution: Complete.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 18 January 2024
Resolved
Prove proper operation of the anchor system following repairs to the wild cat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2024
Resolution: Tested anchor following repairs to the windless. Sat.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 January 2024
Resolved
Conduct all required drills prior to operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2024
Resolution: Complete.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2022
Resolved
Repair leak in hydraulic steering pipe in E/R.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2022
Resolution: Hydraulic pipe elbow repaired sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2022
Resolved
Properly terminate dead end wires in E/R (iwo FO day tank).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 27 October 2022
Resolution: Dead end wires removed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 October 2022
Resolved
Renew instructions for HALON system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 27 October 2022
Resolution: New instructions printed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 13 January 2022
Resolved
Vessel to complete underway drills in the presence of attending MI prior to resuming operations.
Action required: 705 - Other - as specified
Resolved 26 July 2022
Resolution: Witnessed satisfactory MOB drill.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 August 2021
Resolved
Vessels hydrolic oil seal on the bow thruster is leaking into the marine environment. Repair or replace seal and prove proper operation of bow thruster.
Action required: 705 - Other - as specified
Due 26 August 2021
Resolved 26 July 2022
Resolution: New bow thruster installed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 December 2020
Resolved
Annual man overboard drill is required. Drill was not conducted due to missing ramp for car deck
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2021
Resolution: Drills witnessed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 January 2020
Resolved
Crop and renew weather tight door on 02 deck stbd side.
Action required: 10 - Deficiency Rectified
Due 22 February 2020
Resolved 31 January 2020
Resolution: Repairs have been made.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 January 2020
Resolved
Crop and renew water tight trunk in E/R stbd side.
Action required: 10 - Deficiency Rectified
Due 22 February 2020
Resolved 31 January 2020
Resolution: Water Tight Trunk for E/R has been repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2020
Resolved
Properly terminate wire connection on 02 deck for loud hailer in a box.
Action required: 10 - Deficiency Rectified
Resolved 22 January 2020
Resolution: Corrected on spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2020
Resolved
Properly secure wires for low water sensor in expansion tanks.
Action required: 10 - Deficiency Rectified
Resolved 22 January 2020
Resolution: Corrected on spot.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 January 2020
Resolved
Replace 02 condemned life rings.
Action required: 10 - Deficiency Rectified
Resolved 22 January 2020
Resolution: Corrected on spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 January 2020
Resolved
Correct stowage of life jackets to refelct proper amount on placards.
Action required: 10 - Deficiency Rectified
Resolved 22 January 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2020
Resolved
Properly terminate wire connection for VHF radio.
Action required: 10 - Deficiency Rectified
Resolved 22 January 2020
Resolution: Corrected on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 January 2020
Resolved
Repair aft door to main cabin. Needs to be weater tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2020
Resolved 14 October 2020
Resolution: There is a new weathertight door installed and operational.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 January 2020
Resolved
Service all portable fire extinguishers.
Action required: 10 - Deficiency Rectified
Due 22 January 2020
Resolved 22 January 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 January 2020
Resolved
Provide aspirin and eyewash for the first aid kit.
Action required: 10 - Deficiency Rectified
Resolved 22 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2020
Resolved
Make air receivers available for internal inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2020
Resolved 31 January 2020
Resolution: Inspected internals both were satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 22 January 2020
Resolved
Provide and mount fire control plan on each deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2020
Resolved 31 January 2020
Resolution: Operator provide fire plans for each deck. All SAT
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 January 2020
Resolved
Conduct and log security, abandon ship, man overboard, and fire drills prior to operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2020
Resolution: Crew performed drills when departing to home pier.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 January 2020
Resolved
Prove proper operation of low lube oil alarms indicator light.
Action required: 10 - Deficiency Rectified
Resolved 22 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2020
Resolved
Prove proper operation of low lube oil alarms indicator light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2020
Resolved 14 October 2020
Resolution: Demonstrated proper operation of low lube oil light indicator.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 January 2019
Resolved
Prove proper operation of fixed halon CO2 time delay.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 January 2019
Resolved
Prove proper operation of #2 generator low lube oil shutdown.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2019
Resolved 16 January 2019
Electrical › Lighting (emergency) › Outlet Box
Issued 31 October 2017
Resolved
Repair light bracket for embarcation light FWD STBD upper deck
Condition: Improper/Lack of Maintenance
Due 30 November 2017
Resolved 9 November 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 October 2017
Resolved
Paint NAV light screen running lights.
Condition: Improper/Lack of Maintenance
Due 30 November 2017
Resolved 9 November 2017
Engineering › Bilge Water Management System › Not Operational
Issued 31 October 2017
Resolved
Repair bilge system prior to taking on passengers/cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 October 2017
Resolved
Reoair any loose wiring and make all junction boxes weather tight in engine room.
Condition: Improper/Lack of Maintenance
Due 30 November 2017
Resolved 9 November 2017
Communications › Visual Communication › Warning Sign (gangway)
Issued 31 October 2017
Resolved
Replaced frayed and torn American Flag.
Due 30 November 2017
Resolved 9 November 2017
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 31 October 2017
Resolved
Repair supply pipe.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2017
Engineering › Fuel Oil Service System › Valve, Control
Issued 25 January 2016
Resolved
Day tank e-fuel shut off reach rod was not operational
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2016
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 25 January 2016
Resolved
Alarm panel was disconnected due to a problem with the generator's overspeed shutdown
Due 1 March 2016
Resolved 27 January 2016
Stability › Watertight Integrity › Weathertight Enclosure
Issued 25 January 2016
Resolved
Raised trunk access to the engine room from the main deck was completely wasted on the bottom corner causing a hole in the trunk.
Due 1 March 2016
Resolved 8 November 2016
Resolution: Trunk repaired.
Engineering › Bilge Water Management System › Piping
Issued 25 January 2016
Resolved
Overboard discharge bilge line located in the engine room had a small leak in the pipe.
Due 1 March 2016
Resolved 8 November 2016
Resolution: Pipe repaired.
Construction/Loadline › Structures › Scuttle
Issued 25 January 2016
Resolved
Replace wasted ladder rung in void #4 port side
Due 1 March 2016
Resolved 8 November 2016
Resolution: Ladder repaired.
Construction/Loadline › Structures › Door
Issued 25 January 2016
Resolved
Repair threshold to male head
Due 1 March 2016
Resolved 27 January 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 January 2016
Resolved
Remove ice from battery box adjacent to pilot house
Due 1 March 2016
Resolved 27 January 2016