Records from 1997 to 2023. Most recent: inspection, 4 May 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
4 May 2023
Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7681134
1 August 2017
Type not recorded
No type recorded · USCGC REEF SHARK (WPB 87371) · USCG Arctic District (CGD-A) · Activity 6230676
3 April 2009
Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3443556
13 June 2008
COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3233000
7 May 2008
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3201080
5 September 2007
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3051004
7 June 2007
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2953952
26 September 2006
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2786966
27 June 2005
Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2408779
26 May 2005
Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2368749
12 October 2004
Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2224065
10 February 2004
Deficiency Check
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2003765
1 October 2003
Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1917312
29 May 2003
Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1815057
16 October 2002
Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1690739
3 October 2001
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1395827
23 July 2001
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1379520
26 July 2000
Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1423414
28 July 1999
Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1450328
8 June 1999
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 803258
29 July 1998
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 795160
15 July 1998
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1423041
26 August 1997
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1120085
29 July 1997
Hull Examination · Initial Certification · Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1375070
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 June 2008
Resolved
Prove proper operation of fwd bilge high water alarm. Until cleared, master shall ensure that the fwd bilges are inspected prior to getting underway.
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 14 July 2008
Resolution: Attended vessel and Master demonstrated proper operation of the high water alarm (visual and audible).
Personnel › Training › First Aid/CPR
Issued 5 September 2007
Resolved
SHOW VALID FIRST AID AND CPR CARDS FOR 50% OF CREW.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2008
Resolved 7 May 2008
Resolution: Attended vessel. Issue resolved.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 5 September 2007
Resolved
SERVICE PORTABLE AND FIXED FIRE EXTINGUISHERS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2008
Resolved 7 May 2008
Resolution: Attended vessel. Interstate Fire Service on board during my visit. Portable and fixed systems serviced and tagged.
Lifesaving › Hand Flares › Quantity
Issued 5 September 2007
Resolved
RENEW FLARES - 6 RED AND 6 ORANGE REQUIRED.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2008
Resolved 7 May 2008
Resolution: O?O provided receipt indicating purchase of required flares.
Navigation › Piloting/Steering › Marine Charts
Issued 5 September 2007
Resolved
UPDATE ALL NAV PUBLICATIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2008
Resolved 7 May 2008
Resolution: Required publications purchased and receipt provided.
Lifesaving › Lifefloat › Serviceable
Issued 5 September 2007
Resolved
CLEAN AND REPAIR OR REPLACE 3 LIFEFLOATS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2008
Resolved 7 May 2008
Resolution: Attended vessel. Lifefloats have been repaired. Recommended spacers be placed under the floats to get them off the cabin enough that moisture is not trapped.
Communications › Radio Communications › EPIRB
Issued 5 September 2007
Resolved
REPLACE HYDROSTATIC RELEASE ON EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2008
Resolved 7 May 2008
Resolution: Attended vessel. HRO is new (expires May 2010).
Communications › Radio Communications › EPIRB
Issued 5 September 2007
Resolved
REGISTER EPIRB - PLACE REGISTRATION STICKER ON EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2008
Resolved 7 May 2008
Resolution: Attended vessel. O/O registered online and provided proof of valid registration. Sticker is in the mail.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 September 2007
Resolved
UPDATE FIRST AID KIT - ADD EYEWASH.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2008
Resolved 7 May 2008
Resolution: Attended vessel. New first aid kit is on board.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 5 September 2007
Resolved
POST LIFEJACKET DONNING PLACARD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2008
Resolved 7 May 2008
Resolution: Placard provided.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 September 2007
Resolved
UPDATE PORTABLE LIGHTING - AT LEAST 2 BATTERY POWERED HANDLIGHTS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2008
Resolved 7 May 2008
Resolution: O/O provided receipt proving purchase of 2 flashlights.
Lifesaving › Lifefloat › Lifeline
Issued 26 September 2006
Resolved
Replace wasted grab lines.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 24 October 2006
Resolution: Received phone call from O/O stating that grab lines have been replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 26 September 2006
Resolved
Replace water light lines with 18' length of proper type and size.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 24 October 2006
Resolution: Received call from O/O stating that proper line is in place.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 26 September 2006
Resolved
Prove proper operation of floating waterlights.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 24 October 2006
Resolution: Received call from O/O stating that waterlights are operating satisfcatory.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 26 September 2006
Resolved
Replace missing cap screw on waterlight.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 24 October 2006
Resolution: Received call from O/O stating that new screw is in place.
Lifesaving › Lifefloat › Paddle
Issued 26 September 2006
Resolved
Label lifefloat paddles with vessel name.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 6 November 2006
Resolution: Received call from Master. He advised that item has been completed.
Fire Fighting › Fire Bucket › Quantity
Issued 26 September 2006
Resolved
Provide (3) 2.5 gallon fire buckets.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 24 October 2006
Resolution: Received phone call from O/O stating that buckets are on board.
Electrical › Lighting (service) › Lighting Fixture
Issued 26 September 2006
Resolved
Prove proper operation of cabin lighting.
Action required: 705 - Other - as specified
Due 31 October 2006
Resolved 6 November 2006
Resolution: Received call from Master. He advised that item has been completed.
Communications › Radio Communications › EPIRB
Issued 26 September 2006
Resolved
Provide proof of valid hydrostatic release unit expiration. To be corrected prior to 2007 operating season.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 May 2008
Resolution: Attended vessel. New HRU installed (expires May 2010).
Lifesaving › Lifefloat › Painter
Issued 26 September 2006
Resolved
Properly arrange lifefloat painters (to allow deploying without stacking up).
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 6 November 2006
Resolution: Received call from Master. He advised that item has been completed.
Personnel › Training › Familiarization Training
Issued 27 June 2005
Resolved
SHOW EVIDENCE OF PERIODIC CREW TRAINING - MOB, FIRE DRILL, MEDICAL EMERGENCIES.
Action required: 705 - Other - as specified
Due 27 July 2005
Resolved 19 September 2005
Resolution: CREW TRAINING EVIDENCE PROVIDED
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 27 June 2005
Resolved
SHOW EVIDENCE OF CPR/FIRST AID TRAINING FOR 50% OF CREW WITH CURRENT CERTIFICATION DATES.
Action required: 705 - Other - as specified
Due 27 July 2005
Resolved 19 September 2005
Resolution: PROOF OF CPR/FIRST AID TRAINING PROVIDED
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 June 2005
Resolved
UPDATE FIRST AID KIT.
Action required: 705 - Other - as specified
Due 27 July 2005
Resolved 29 June 2005
Communications › Alarms/Indicators › High Water Alarm
Issued 27 June 2005
Resolved
MAKE ALL AUDIBLE/VISUAL HIGH WATER BILGE ALARMS OPERABLE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2005
Resolved 29 June 2005
Lifesaving › Hand Flares › Not on Board
Issued 27 June 2005
Resolved
ADD MINIMUM OF 6 ORANGE FLARES TO VISUAL SIGNALING DEVICES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2005
Resolved 29 June 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 27 June 2005
Resolved
SHOW EVIDENCE OF CURRENT RADIO SAFETY CERTIFICATE.
Action required: 705 - Other - as specified
Due 27 July 2005
Resolved 29 June 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 October 2004
Resolved
SERVICE/MAKE OPERABLE HIGH WATER BILGE ALARMS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 29 June 2005
Lifesaving › Hand Flares › Not on Board
Issued 12 October 2004
Resolved
6 ORANGE FLARES REQUIRED ON BOARD.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 29 June 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 October 2004
Resolved
MAKE OPERABLE EMERGENCY FUEL SHUTOFF.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 27 June 2005
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 12 October 2004
Resolved
SERVICE ENGINE ROOM VENT HANDLES.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 27 June 2005
Construction/Loadline › Structures › Manhole
Issued 12 October 2004
Resolved
SERVICE WATERTIGHT HATCHES.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 27 June 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 12 October 2004
Resolved
SHOW EVIDENCE OF FCC RADIO SAFETY CERTIFICATE.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 29 June 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 12 October 2004
Resolved
SHOW EVIDENCE OF RADIO STATION LICENSE.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 27 June 2005
Lifesaving › Lifebuoys
Issued 1 October 2003
Resolved
REPAIR/REPLACE RING LIFEBUOY (GRAB-LINE AND BECKETS DETERIORATED).
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 1 October 2003
Lifesaving › Buoyant Apparatus
Issued 1 October 2003
Resolved
REPLACE MISSING SCREW ON LIFEFLOAT WATERLIGHT.
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 1 October 2003
Lifesaving › Buoyant Apparatus
Issued 1 October 2003
Resolved
MARK CAPACITY (NUMBER OF PERSONS) ON ALL LIFEFLOATS.
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 1 October 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 1 October 2003
Resolved
CONDUCT 6-YR SERVICE ON PORTABLE DRY-CHEMICAL FIRE EXTINGUISHER IN FWD ACCOMMODATIONS SPACE (MANUFACTURED 1997). LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 1 October 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 1 October 2003
Resolved
PROVIDE DOCUMENTATION FOR ANNUAL SERVICING OF FIXED FIRE FIGHTING CYLINDER, INCLUDING TEST OF AUTOMATIC ENGINE SHUTDOWN FEATURE.
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 1 October 2003
Construction/Loadline › Hull › Hull Plating
Issued 29 May 2003
Resolved
Small 3" by 2" fracture of gel coat in way of port bow approximately 24" above waterline.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2003
Resolved 10 June 2003
Resolution: Sanded, applied gel coat.
Unknown
Issued 3 October 2001
Resolved
PROVIDE PROPER DOCUMENTATION THAT AT LEAST 50% OF CREW HAS CURRENT FIRST AID TRAINING.
Condition: Unknown
Due 17 October 2001
Resolved 17 October 2001
Unknown
Issued 3 October 2001
Resolved
Replace outdated asprin and zinc oxide in first aid kit with current items.
Condition: Unknown
Due 17 October 2001
Resolved 17 October 2001
Unknown
Issued 3 October 2001
Resolved
PROPERLY ATTACH LIFE-FLOAT SO THAT EACH LIFE-FLOAT IS ATTACHED TO THE WEAK LINK AS DISCRIBED DURING REINSPECTION.
Condition: Unknown
Due 17 October 2001
Resolved 17 October 2001
Unknown
Issued 3 October 2001
Resolved
SHOW PROPER INSTALLATION OF CURRENT HYDROSTATIC RELEASE FOR EPIRB. VSL'S OPERATION IS RESTRICTED TO WITHIN THREE MILES OF LAND UNTIL CORRECTED.
Condition: Unknown
Due 17 October 2001
Resolved 17 October 2001
Unknown
Issued 3 October 2001
Resolved
PROPERLY LOG AND MAINTAIN REQUIRED LOG BOOK FOR ALL LIFESAVING/FIRE FIGHTING MAINTENANCE RECORDS AND TRAINING DRILLS AND MAINTAIN IN LOG BOOK.
Condition: Unknown
Due 17 October 2001
Resolved 17 October 2001
Unknown
Issued 3 October 2001
Resolved
PROVIDE PROPER UPDATED AND CORRECT CHART FOR AREA COVERED BY COI.
Condition: Unknown
Due 17 October 2001
Resolved 17 October 2001
Lifesaving
Issued 26 July 2000
Resolved
Provide six (6) orange day smokes.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Electrical
Issued 26 July 2000
Resolved
Provide two (2) flashlights for emergency lighting.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Navigation
Issued 26 July 2000
Resolved
Provide Coast Pilot [name withheld], and Tide Tables.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Fire Fighting
Issued 26 July 2000
Resolved
Provide three (3) properly marked fire buckets with lanyards.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Lifesaving
Issued 8 June 1999
Resolved
Stencil in 2" letters: emergency fuel shutdown, E/R vent closures, and bilge high-water alarm indicators.
Condition: Unknown
Due 10 June 1999
Resolved 1 July 1999
Unknown
Issued 8 June 1999
Resolved
By 8JUL99, submit completed MIS report to COMDT. Comply w/ additional items noted on audit form by same date (maintain copies of neg. test results for 1 yr.; maintain copy of consortium contract in files).
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Lifesaving
Issued 8 June 1999
Resolved
Provide 3 orange/3 red flares.
Condition: Unknown
Due 10 June 1999
Resolved 1 July 1999
Documentation
Issued 8 June 1999
Resolved
Provide FCC Radiotelephony Certificate.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Documentation
Issued 15 July 1998
Resolved
PROVIDE PROPER DOCUMENTATION OF A FULLY COMPLIANT CHEMICAL TESTING PROGRAM.THE MARINE EMPLOYER IS NOT AUTHORIZED TO OPERATE AFTER 15 AUGUST 1998 UNLESS THIS REQUIREMENT HAS BEEN CLEARED TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Navigation
Issued 15 July 1998
Resolved
PROVIDE PROPER/REQUIRED CHARTS AND PUBS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Documentation
Issued 15 July 1998
Resolved
PROVIDE PROPER EPIRB REGISTRATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Lifesaving
Issued 29 July 1997
Resolved
VESSEL RESTRICTED TO THE 03 MILE TERRITORIAL SEA LINE WITH 32 PERSONS OR COASTWISE NMT 20NM WITH 18 PERSONS UNTIL PRIMARY LIFESAVING FOR 14 MORE PERSONS IS ONBOARD.