Records from 1983 to 2004. Most recent: inspection, 2 August 2004.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)340.4 ft × 50.1 ft × 12.5 ft
Registered tonnagegross 1,749 / net 1,749
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAMERICAN MARINE CORP · NEW ORLEANS, LA, UNITED STATES · built 1968
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1749 - Regulatory (Subpart C or D), Gross Ton
1749 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 51
2 August 2004
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2153281
7 August 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1071018
13 June 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1426612
7 March 2001
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1423527
17 February 2001
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 25243
17 February 2001
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1415562
14 September 2000
Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1448171
23 August 2000
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1415433
14 June 1999
Hull Examination · Examination of Repairs · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 806305
14 June 1999
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 880041
13 January 1999
COI Inspection · Examination of Repairs · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1340782
20 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1086594
8 June 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141686
11 February 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1376928
24 August 1992
Deficiency Check · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 936567
3 April 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 951203
28 February 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 665466
28 February 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 665467
19 February 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 437807
19 February 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 452081
22 September 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 540381
11 February 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 914043
3 January 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 927944
15 October 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 470695
28 August 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 910544
1 July 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1225136
21 May 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1224455
21 May 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1244458
28 March 1990
Permit to Proceed
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 910842
27 March 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 527719
25 July 1989
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1350984
18 July 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 887820
3 February 1989
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1210610
17 March 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 457910
29 February 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333467
25 January 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 466759
4 December 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 470027
8 November 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 532785
10 June 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 505645
9 June 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 483132
25 March 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 439466
26 January 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324278
19 March 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 517787
18 December 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984813
1 October 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 476033
16 June 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 508196
15 April 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 982462
13 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983613
9 November 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 298885
8 August 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 977375
11 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272219
Unknown
Issued 13 June 2001
Resolved
Thermal fluid heater could not be tested as a part of the COI inspection due to the cargo that the vessel was carrying. A proper test is required prior to operation.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Construction/Loadline
Issued 17 February 2001
Resolved
Conduct repairs to barge damage referenced in MINS to the satisfaction of the attending marine inspector._x001C_
Condition: Unknown
Due 17 February 2001
Resolved 17 February 2001
Deck/Cargo
Issued 14 September 2000
Resolved
Make permanent repair to pin hole on discharge piping, hole located on piping approximatley 10ft to 12ft from prime mover.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Deck/Cargo
Issued 11 February 1993
Resolved
PRIOR TO LOADING OF GRADE "E" CARGOES PROVE THERMAL FLUID HEATER SYSTEM INTACT BY CONDUCTING AN HYDROSTATIC TEST OF ALL THERMAL FLUID PIPING @ 1.5 MAWP.
Condition: Unknown
Due 11 February 1993
Resolved 11 February 1993
Deck/Cargo
Issued 11 February 1993
Resolved
PRIOR TO LOADING OF GRADE "E" CARGOES CONDUCT ALL OPERATIONAL TESTS TO THE THERMAL FLUID HEATER IAW AN APPROVED THERMAL HEATER FLUID TEST PROCEDURE.
Condition: Unknown
Due 11 February 1993
Resolved 11 February 1993
Deck/Cargo
Issued 11 February 1993
Resolved
PLACE A COPY OF THE APPROVED TEST PROCEDURE ONBOARD THE BARGE PRIOR TO LOADING GRADE "E" CARGOES.
Condition: Unknown
Due 11 February 1993
Resolved 11 February 1993
Construction/Loadline
Issued 3 April 1992
Resolved
FREE OR RENEW DOGS ON #5 PORT WING TANK.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Deck/Cargo
Issued 3 April 1992
Resolved
INSTALL DECALS OR STENCIL DEISEL TANK.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Construction/Loadline
Issued 3 April 1992
Resolved
INSTALL DOGS ON BOW THRUSTER ROOM HATCH.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Engineering
Issued 3 April 1992
Resolved
REPAIR RAIN COVER FOR COVER STACK, FOR THERMAL HEATER.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Construction/Loadline
Issued 3 April 1992
Resolved
MAKE VESSEL'S WING TANKS FORWARD RAKE AND STERN BOX AVAILABLE FOR INTERNAL STRUCTURE EXAM.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Construction/Loadline
Issued 3 April 1992
Resolved
INSALL DOG ON #2 STARBOARD WING TANK HATCH.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Construction/Loadline
Issued 3 April 1992
Resolved
REPIAR FRACTURE IN STARBOARD CORNER HEAD LOG.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Electrical
Issued 3 April 1992
Resolved
INSTALL JUNCTION BOX TO MAKE CONNECTIONS WHERE NAV LIGHT WIRES ARE SPLICED.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Deck/Cargo
Issued 3 April 1992
Resolved
INSTALL GUARD OVER CARGO PUMP COUPLING.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Engineering
Issued 11 February 1991
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Deck/Cargo
Issued 11 February 1991
Resolved
PROVIDE PLUG FOR DRAINS ON BOTH PORT AND STBD CONTAINMENT.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Electrical
Issued 11 February 1991
Resolved
REPLACE LIGHT BULB, GLASS AND SHIELD FOR FIXTURE IN THERMAL HEATER ROOM.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Construction/Loadline
Issued 11 February 1991
Resolved
FIX OR REPLACE FROZEN DOGS #1 STARBOARD WING VOID AND #5 PORT WING VOID.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Electrical
Issued 21 May 1990
Resolved
REPAIR AND PROVE OPERATION OF LOSS OF LUBE OIL TRIP FOR GENERATOR.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Deck/Cargo
Issued 21 May 1990
Resolved
REPAIR AND PROVE OPERATION OF BOW THRUSTER.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Engineering
Issued 21 May 1990
Resolved
PROVIDE FLAME DEFLECTORS FOR DIESEL FILTERS AFT OF DECK DIESEL TANK.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Electrical
Issued 21 May 1990
Resolved
REMOVE OIL FROM ENGINE AND CLEAN OIL FROM DECK UNDER AND AROUND ENGINE IN GENERATOR ROOM.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Construction/Loadline
Issued 25 July 1989
Resolved
OFFLOAD TANK BARGE AND EFFECT PERMANENT REPAIRS TO #5 STBD WING TANK IN WAYOF 4 FT FRACTURE TO DECK GUNALE. TO BE COMPLETED TO THE SATISFACTION OF THEATTENDING USCG INSPECTOR
Condition: Unknown
Due 25 July 1989
Resolved 25 July 1989