MAURY USCG vessel records Sign in
← All vessels

THE SAINT

THE SAINT is a 1968 freight ship. The Coast Guard has recorded 45 inspections since 1985, most recently in April 2002, along with 74 deficiencies — 17 with no resolution recorded — and 3 operational controls.

Records from 1985 to 2002. Most recent: operational control imposed, 8 April 2002.

Built
1968
Last inspected
8 April 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-45967

Inspections, by type

…with no type recorded23
…past their stated due date17
Years with a record 15 calendar years (1985–2002)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it79 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 45

8 April 2002 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1609740
9 April 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 288919
19 March 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 288239
9 March 2001 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1058193
12 February 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 287047
29 January 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 286545
26 October 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 283497
16 October 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 283049
11 September 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 282020
17 April 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 276909
9 August 1999 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 431464
6 July 1999 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 430347
9 December 1998 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 423469
28 August 1998 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 488404
29 June 1998 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 417342
27 May 1998 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 416785
23 April 1998 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 415897
19 March 1998 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 726792
26 August 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 407056
20 February 1997 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1105830
29 January 1997 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 212525
29 January 1997 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 214296
15 December 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1149836
2 December 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 869420
25 October 1994 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1409185
25 October 1993 COI Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1370727
4 August 1993 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1459030
27 January 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 825758
22 October 1992 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1136256
5 February 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 946609
25 October 1991 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 939100
25 June 1991 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1249346
31 January 1991 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1240503
25 October 1990 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1224095
4 April 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 901763
9 March 1990 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1236419
30 January 1990 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1220031
21 December 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1222611
25 October 1988 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1044301
13 May 1988 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1352352
12 December 1986 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1322305
12 November 1986 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1018878
8 August 1985 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 984354
4 April 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 985884
22 January 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 977206

Deficiency record · 74

Engineering › Fuel Oil Service System › Valve, Control
Issued 8 April 2002 No resolution recorded
Prove proper operation of remote fuel shut off
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 15 April 2002 — due date passed with no resolution recorded
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 8 April 2002 No resolution recorded
Make repairs and prove engine room ventillation shutdowns
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 15 April 2002 — due date passed with no resolution recorded
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 8 April 2002 No resolution recorded
Provide class report attesting to the satisfactory operation of the fire and smoke dtectors
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Due 15 April 2002 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Pump
Issued 8 April 2002 Resolved
Provide class report attesting to the de-watering capability iaw CCSSC 2.18
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2002
Resolved 16 April 2002
Resolution: Corrected
Fire Fighting
Issued 8 April 2002 Resolved
Provide class report attesting to sat. operation of all fire pumps, hydrants, hoses, nozzles and stations
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2002
Resolved 16 April 2002
Resolution: Corrected
Engineering
Issued 8 April 2002 No resolution recorded
Prove proper operation of overspeed devices iaw CCSSC 2.24.3
Action required: 15 - Rectify deficiencies by next port
Due 15 April 2002 — due date passed with no resolution recorded
Fire Fighting
Issued 8 April 2002 No resolution recorded
Provide fire bucket iaw 3.9.2
Action required: 15 - Rectify deficiencies by next port
Due 15 April 2002 — due date passed with no resolution recorded
Navigation
Issued 8 April 2002 No resolution recorded
Provide publications iaw Chapter V, SOLAS 74
Action required: 15 - Rectify deficiencies by next port
Due 15 April 2002 — due date passed with no resolution recorded
Navigation
Issued 8 April 2002 No resolution recorded
Update deviation card
Action required: 705 - Other - as specified
Due 8 May 2002 — due date passed with no resolution recorded
Lifesaving
Issued 8 April 2002 No resolution recorded
Renew ring buoy retro tape
Action required: 705 - Other - as specified
Due 22 April 2002 — due date passed with no resolution recorded
Lifesaving
Issued 8 April 2002 No resolution recorded
Renew retro reflective tape on PFD
Action required: 705 - Other - as specified
Due 22 April 2002 — due date passed with no resolution recorded
Fire Fighting
Issued 8 April 2002 No resolution recorded
Prove galley acceptance of galley stove installation iaw CCSSC
Action required: 705 - Other - as specified
Due 8 May 2002 — due date passed with no resolution recorded
Construction/Loadline
Issued 8 April 2002 No resolution recorded
Renew port fwd. port hole/stbd. port hole
Action required: 705 - Other - as specified
Due 22 April 2002 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 8 April 2002 No resolution recorded
Renew failed accomodation lights
Action required: 705 - Other - as specified
Due 22 April 2002 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 8 April 2002 Resolved
Remove gasoline stored in accomodation space
Due 8 April 2002
Resolved 8 April 2002
Resolution: Corrected
Documentation
Issued 8 April 2002 No resolution recorded
Prove flag acceptance for safe manning cert. and vessel is liscensed and crewed accordingly
Action required: 15 - Rectify deficiencies by next port
Due 8 April 2002 — due date passed with no resolution recorded
Construction/Loadline
Issued 8 April 2002 No resolution recorded
Replace stbd. window bridge
Action required: 705 - Other - as specified
Due 22 April 2002 — due date passed with no resolution recorded
Navigation
Issued 8 April 2002 No resolution recorded
Upgrade antenna for bridge radio (SEA LAB 2525)
Due 22 April 2002 — due date passed with no resolution recorded
Navigation
Issued 16 October 2000 Resolved
Make repairs to steering cable sheave starboard side steering space.
Condition: Unknown
Due 16 October 2000
Resolved 26 October 2000
Navigation
Issued 16 October 2000 Resolved
Make repairs and prove operation of anchor light.
Condition: Unknown
Due 30 October 2000
Resolved 26 October 2000
Fire Fighting
Issued 16 October 2000 Resolved
Provide fire pumps i.a.w. CCSSC record of equipment.
Condition: Unknown
Due 16 October 2000
Resolved 26 October 2000
Navigation
Issued 16 October 2000 Resolved
Provide VHF radio instructions i.a.w. CCSSC 5.10.5.
Condition: Unknown
Due 21 December 2000
Resolved 21 December 2000
Construction/Loadline
Issued 16 October 2000 Resolved
Renew port side Samson Post. Post not to be used until corrected.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Fire Fighting
Issued 16 October 2000 Resolved
Provide fire ax i.a.w. CCSSC 3.12.
Condition: Unknown
Due 7 December 2000
Resolved 7 December 2000
Lifesaving
Issued 16 October 2000 Resolved
Renew ring bouy retroreflective tape.
Condition: Unknown
Due 30 October 2000
Resolved 26 October 2000
Accommodation/Occupational Safety
Issued 16 October 2000 Resolved
Remove stores from toilet and make repairs to sink.
Condition: Unknown
Due 30 October 2000
Resolved 26 October 2000
Engineering
Issued 16 October 2000 Resolved
Make repairs and prove operation of main engine automatic shutoff arrangement i.a.w. CCSSC 2.25 and 2.24.6.
Condition: Unknown
Due 1 February 2001
Resolved 20 March 2001
Lifesaving
Issued 16 October 2000 Resolved
Provide operation of rescue boat motor.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Documentation
Issued 16 October 2000 Resolved
Provide radio station licenses.
Condition: Unknown
Due 7 December 2000
Resolved 7 December 2000
Construction/Loadline
Issued 16 October 2000 Resolved
Freshen loadline and draft marks.
Condition: Unknown
Due 19 December 2000
Resolved 21 December 2000
Navigation
Issued 16 October 2000 No resolution recorded
Provide corrected charts.
Condition: Unknown
Due 23 October 2000 — due date passed with no resolution recorded
Navigation
Issued 16 October 2000 Resolved
Renew forward mast running light lense._x001C_
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Documentation
Issued 16 October 2000 Resolved
Provide Safe Manning Document
Condition: Unknown
Due 16 October 2000
Resolved 26 October 2000
Engineering
Issued 16 October 2000 Resolved
Make repairs and prove operation of Port Main Engine.
Condition: Unknown
Due 16 October 2000
Resolved 26 October 2000
Navigation
Issued 16 October 2000 Resolved
Provide deviation table.
Condition: Unknown
Due 1 February 2001
Resolved 20 March 2001
Construction/Loadline
Issued 16 October 2000 Resolved
Provide bilge pumping arrangement i.a.w. CCSSC 2.18.
Condition: Unknown
Due 16 October 2000
Resolved 26 October 2000
Documentation
Issued 16 October 2000 No resolution recorded
Provide ships plans i.a.w. CCSSC 1.8
Condition: Unknown
Due 30 October 2000 — due date passed with no resolution recorded
Engineering
Issued 16 October 2000 Resolved
Make repairs and prove operation of overspeed trips on main engines.
Condition: Unknown
Due 1 February 2001
Resolved 20 March 2001
Fire Fighting
Issued 16 October 2000 Resolved
Prove operation of engine room fire detector.
Condition: Unknown
Due 1 February 2001
Resolved 20 March 2001
Lifesaving
Issued 16 October 2000 Resolved
Renew EPIRB battery or provide EPIRB i.a.w. CCSSC 5.13.
Condition: Unknown
Due 16 October 2000
Resolved 26 October 2000
Documentation
Issued 16 October 2000 Resolved
Provide Master and crew i.a.w. Safe Manning document.
Condition: Unknown
Due 16 October 2000
Resolved 26 October 2000
Navigation
Issued 16 October 2000 Resolved
Provide emergency instructions i.a.w. CCSSC 4.16.
Condition: Unknown
Due 21 December 2000
Resolved 21 December 2000
Fire Fighting
Issued 17 April 2000 Resolved
Professionally service portable fire extinguishers.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Documentation
Issued 17 April 2000 Resolved
Provide onboard the Annex to the Caribbean Cargo Ship Safety Certificate (describes equipment to be fitted onboard).
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Lifesaving
Issued 6 July 1999 Resolved
Professionally service inflatable liferaft at next St. Thomas port call._x001C_ _x001C_ CCSSC Ch.47
Condition: Unknown
Due 11 August 1999
Resolved 11 August 1999
Lifesaving
Issued 6 July 1999 Resolved
Apply new retro-reflective tape to lifebouys._x001C_ SOLAS 74
Condition: Unknown
Due 11 August 1999
Resolved 11 August 1999
Lifesaving
Issued 26 August 1997 Resolved
ENSURE LIFERAFT REQUIRED BY CCSSC (4.4) IS ONBOARD.
Condition: Unknown
Due 3 July 1998
Resolved 3 July 1998
Documentation
Issued 26 August 1997 Resolved
PROVIDE PROOF OF AN APPLICATION FOR A CCSS CERTIFICATE FROM FLAG STATE. 01JAN98 VSL IS TO HAVE A VALID CERTIFICATE ONBOARD.
Condition: Unknown
Due 3 July 1998
Resolved 3 July 1998
Unknown
Issued 26 August 1997 Resolved
(104) DEFICIENCIES ISSUED. CONTACT RIO ST CROIX FOR DETAILS (340/772-5557).
Condition: Unknown
Due 3 July 1998
Resolved 3 July 1998
Navigation
Issued 25 October 1994 Resolved
Provide copies of 46 CFR subchapter T and charts that cover all routes undertaken by this vessel.
Condition: Unknown
Due 25 October 1994
Resolved 25 October 1994
Construction/Loadline
Issued 25 October 1994 Resolved
Repair hole from the main deck to the lazzarette, port side, on the stern.
Condition: Unknown
Due 25 October 1994
Resolved 25 October 1994
Accommodation/Occupational Safety
Issued 25 October 1994 Resolved
Replace cracked holding tank on starboard MSD. Do Not operate MSD until repairs have been effected. If repairs are not planned the removal of defective MSD will be required.
Condition: Unknown
Due 25 October 1994
Resolved 25 October 1994
Construction/Loadline
Issued 25 October 1994 Resolved
Replace all watertight door and hatch gaskets on the main deck.
Condition: Unknown
Due 25 October 1994
Resolved 25 October 1994
Documentation
Issued 25 October 1994 Resolved
Provide a Drug Testing Program for marine employees in accordance with 46 CFR part 16.
Condition: Unknown
Due 25 October 1994
Resolved 25 October 1994
Lifesaving
Issued 25 October 1994 Resolved
Replace missing and rejected lifejackets. Five (5) adult and one (1) childs. Passengers reduced by this amount until corrected.
Condition: Unknown
Due 25 October 1994
Resolved 25 October 1994
Fire Fighting
Issued 25 October 1994 Resolved
Replace missing hand portable fire/bilge pump. All other firefighting equipment on board in satisfactory condition to include two (2) extra B-II extinguishers.
Condition: Unknown
Due 25 October 1994
Resolved 25 October 1994
Engineering
Issued 25 October 1994 Resolved
Replace rope ties on hydraulic lines with approved ties in engine room on port side engine.
Condition: Unknown
Due 25 October 1994
Resolved 25 October 1994
Deck/Cargo
Issued 25 October 1994 Resolved
Repair or replace worn electrical wires to the motor and pump that operate the stern ramp.
Condition: Unknown
Due 25 October 1994
Resolved 25 October 1994
Electrical
Issued 4 August 1993 Resolved
CROP OUT OLD WIRING IN AFT STEERING AND USE WIRE CONNECTORS ON LIGHT WIRING
Condition: Unknown
Due 31 December 1993
Resolved 31 December 1993
Electrical
Issued 4 August 1993 Resolved
CROP OUT GENERATOR WIRING IN E/R.
Condition: Unknown
Due 31 December 1993
Resolved 31 December 1993
Accommodation/Occupational Safety
Issued 25 October 1991 Resolved
OPEN AIR RECEIVER FOR INTERNAL INSPECTION AND TEST RELIEF VALVE.
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Lifesaving
Issued 25 October 1991 Resolved
PROVIDE SEINED LINE AROUND EACH BUOYANT APPARATUS SO THAT BETWEEN EACH ATTACHMENT POINT THERE WILL BE 30".
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Fire Fighting
Issued 25 October 1991 Resolved
PROVIDE BRACKETS FOR PORTABLE FIRE EXTINGUISHERS SO THAT THEY WILL BE SECURE DURING HEAVY SEAS.
Condition: Unknown
Due 25 October 1991
Resolved 25 October 1991
Electrical
Issued 25 October 1990 Resolved
PROVIDE A DIELECTRIC MAT IN FRONT OF MAIN DISTRIBUTION PANEL IN THE ENGINE ROOM TO PROVIDE ELECTRICAL SHOCK PROTECTION FOR PERSONNEL.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990 Resolved
PROVIDE A BATTERY BOX FOR THE MSD OPERATING BATTERY LOCATED IN THE PORT SIDE STORAGE LOCKER IN THE ACCOMODATION SPACE.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Fire Fighting
Issued 25 October 1990 Resolved
REPLACE GASKET MATERIAL IN THE FIRE PUMP STRAINER TO SEAL LEAK THAT DEVELOPS WHILE THE FIRE MAIN IS PRESSURIZED.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Construction/Loadline
Issued 30 January 1990 Resolved
REPLACE/REPAIR ENGINEROOM ACCESS HATCHCOVER ON PORT SIDE.
Condition: Unknown
Due 30 January 1990
Resolved 30 January 1990
Lifesaving
Issued 30 January 1990 Resolved
REPLACE/REPAIR SUPPORTS FOR THE LIFEFLOAT PLATEFORM.
Condition: Unknown
Due 30 January 1990
Resolved 30 January 1990
Construction/Loadline
Issued 30 January 1990 Resolved
REPLACE RUBBER GASKET ON MANHOLE COVER.
Condition: Unknown
Due 30 January 1990
Resolved 30 January 1990
Fire Fighting
Issued 22 January 1985 Resolved
REPAIR OR PLACE FIRE PUMP
Condition: Unknown
Due 22 January 1985
Resolved 22 January 1985
Lifesaving
Issued 22 January 1985 Resolved
ATTACH 100 FOOT LINE BUOYANT APPARATUS AND LINE TO VESSEL BY MEANS OF A WEAK LINK
Condition: Unknown
Due 22 January 1985
Resolved 22 January 1985
Construction/Loadline
Issued 22 January 1985 Resolved
REPLACE STARBOARD STERN DECK HATCH
Condition: Unknown
Due 22 January 1985
Resolved 22 January 1985
Unknown
Issued 22 January 1985 Resolved
POST LEGIBLE EMERGERNCY CHECK-OFF LIST IN PASSENGER AREA.
Condition: Unknown
Due 22 January 1985
Resolved 22 January 1985
Lifesaving
Issued 22 January 1985 Resolved
REPLACE ALL OUTDATED DISTRESS SIGNALS (6 HAND HELD ORANGE SMOKE AND 6 HAND HELD RED FLARES OR 12 COMBINATION ORANGE SMOKE, RED FLARE).
Condition: Unknown
Due 22 January 1985
Resolved 22 January 1985

Ownership record