Inspection history · 15
19 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8139252
25 February 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8084886
28 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7943897
10 May 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7680958
8 February 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7634379
16 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7534098
10 February 2021
COI Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7141295
9 July 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7002854
14 May 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6683970
14 January 2019
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6610162
29 May 2018
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6427808
5 December 2017
Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6318677
8 June 2017
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6169465
19 December 2016
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6059820
12 May 2016
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5875171
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 May 2023
Resolved
Each survival craft must be Secured to the vessel by a
painter with a float-free link permanently attached to
the vessel. Float free link is not connected correctly.
Corrected by end of inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2023
Resolution: Float free link connected correctly prior to end of inspection.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 May 2023
Resolved
On a vessel of at least 7.9 meters (26 feet) in length,
a visual and audible alarm must be provided at the
operating station to indicate a high water level in each
of the following normally unmanned spaces... #2
compartment and engine room alarms do not function.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2023
Resolution: Alarms were repaired and test satisfactorily.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 10 May 2023
Resolved
A vessel must comply with the applicable requirements
for any radio and Electronic Position Indicating
Radiobeacon (EPIRB) installations, including the
requirements for a station license and installation
certificates to be issued by the Federal Communications
Commission, as set forth in 47 CFR part 80. Vessel does
not have an FCC safety radiotelephony certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 October 2023
Resolution: Radio safety telephony certificate issued.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 May 2023
Resolved
A fire hose with a nozzle must be attached to each fire
hydrant at all times. Vessel fire hose was not attached
to the fire station.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 October 2023
Resolution: Fire hose attached permanently to fire station.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 May 2023
Resolved
Each portable fire extinguisher on a vessel must be of
an approved type. Vessel fire extinguishers do not have
approved brackets that are a requirement of the overall
extinguisher approval (noted on extinguisher label).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 October 2023
Resolution: Brackets installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 May 2023
Resolved
The Certificate of Inspection must be posted under glass
or other suitable transparent material, such that all
pages are visible, in a conspicuous place on the vessel
where observation by passengers is likely. COI not
posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 October 2023
Resolution: COI has been posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 August 2022
Resolved
COI required to be posted with all pages visible in a place likely to be seen by passengers. COI was not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2022
Resolved 30 August 2022
Resolution: COI posted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 August 2022
Resolved
Hatches require means to be secured to vessel. Laz hatch has no means.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2022
Resolved 30 August 2022
Resolution: Retaining device installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 August 2022
Resolved
IBA required to be secured w/ weak link. IBA not secured by weak link. Corrected by end of inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2022
Resolution: Hydrostatic release was made to be properly arranged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 August 2022
Resolved
PFD container must be designed to allow life jackets to float free. Containers were tied shut. Working with operator to establish a better system to store and access PFDs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2022
Resolved 26 October 2023
Resolution: No longer knotted closed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 August 2022
Resolved
Installed fire suppression requires service. Not serviced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2022
Resolved 30 August 2022
Resolution: Servicing record provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2020
Resolved
One Length of fire hose shall be provided for each fire hydrant required. May be garden hose of not less than 5/8-inch nominal inside diameter, and in one piece not less than 25 feet and not more than 50 feet in length. A length of fire hose shall be attached to each fire hydrant at all times.
Fire hose being used did not meet requirements. Replace with proper hose. CORRECT NLT 10JUL20 (46 CFR 181.15-10)
Action required: 705 - Other - as specified
Due 10 July 2020
Resolved 11 July 2020
Resolution: Replaced and installed fire hose.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 July 2020
Resolved
Penetrations and openings in watertight bulkheads must
have means to make them watertight.
Wiring penetration for inverter between E/R and void #4
not watertight. CORRECT NLT 23JUL20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2020
Resolved 23 July 2020
Resolution: Penetration made watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 July 2020
Resolved
A submersible electric bilge pump may be used as a power
bilge pump required by Table 182.520(a) provided that a
positive shutoff valve is installed at the hull
penetration.
Several submersible electric bilge pump discharge lines
are installed with no positive shutoff valve at the hull
penetration. CORRECT DURING NEXT DRY DOCK, BUT NLT
31MAY2021
Action required: 705 - Other - as specified
Due 31 May 2021
Resolved 19 May 2021
Resolution: Valves installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 May 2019
Resolved
Post COI and Stability Letters
Due 14 June 2019
Resolved 6 June 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 May 2019
Resolved
Provide new aspirin and iodine.
Due 14 June 2019
Resolved 6 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 June 2018
Resolved
Provide 6 additional flares.
Due 29 June 2018
Resolved 5 July 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 June 2018
Resolved
Provide lanyards for hatches.
Due 29 June 2018
Resolved 5 July 2018
Engineering › Reduction Gearing/Clutches › Shaft
Issued 5 December 2017
Resolved
Conduct power trials after new aqua-drives installed
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2018
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 20 June 2017
Resolved
Expired
Due 20 July 2017
Resolved 6 September 2017
Documentation › Certificates/Documents › FCC SSL
Issued 20 June 2017
Resolved
Expired
Due 20 July 2017
Resolved 11 June 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 June 2017
Resolved
Expired Aspirin
Due 20 July 2017
Resolved 11 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 20 June 2017
Resolved
Label storage location
Due 20 July 2017
Resolved 31 August 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 20 June 2017
Resolved
Not labelled
Due 20 July 2017
Resolved 11 July 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 20 June 2017
Resolved
GPS not connected for DSC
Due 20 July 2017
Resolved 11 July 2017
Stability › Watertight Integrity › General
Issued 20 June 2017
Resolved
Hatches not secured to coaming
Due 20 July 2017
Resolved 11 June 2018
Stability › Watertight Integrity › Weathertight Enclosure
Issued 20 June 2017
Resolved
Dogs on hatches inoperative
Due 20 July 2017
Resolved 11 June 2018
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 20 June 2017
Resolved
Tank not proven to be visually inspected
Due 20 July 2017
Resolved 28 June 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 May 2016
Resolved
Provide ammonia inhalants for first aid kit
Due 3 June 2016
Resolved 7 June 2016
Engineering › Bilge Water Management System › Not Operational
Issued 19 May 2016
Resolved
Prove proper operation of fixed bilge water system. Reduced passenger count to 49.
Due 3 June 2016
Resolved 7 June 2016