MAURY USCG vessel records Sign in
← All vessels

SOUND BOUND III

SOUND BOUND III is a 1997 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 1998, most recently in October 2025, along with 73 deficiencies, 1 operational control, 1 with no removal date recorded and 4 casualty investigations between 2004 and 2013.

Records from 1998 to 2025. Most recent: inspection, 7 October 2025.

Built
1997
Last inspected
7 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDJ3453
459737
Flag
UNITED STATES
367768130
Maury page id
psix-459737

Inspections, by type

…with no type recorded10
Years with a record 23 calendar years (1998–2025)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)43.0 ft × 15.0 ft × 8.0 ft
Registered tonnagegross 34 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTORRES BOAT MFG. INC. · KEY WEST, FL, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 29 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Simplified, Gross Ton
27 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ3453MMSI 367768130 · active · compulsorily equipped · granted 11 January 2017, expires 11 January 2027
WDF4114MMSI 367448150 · expired · compulsorily equipped · granted 20 April 2010, cancelled 20 June 2020
WCX7228MMSI 367305960 · expired · voluntarily equipped · granted 2 August 2007, cancelled 11 November 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 46

7 October 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8247426
9 October 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8016417
12 August 2024 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7979397
6 August 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7975696
7 April 2024 Type not recorded
No type recorded · Station New London · USCG Northeast District (CGD-NE) · Activity 7894025
11 July 2023 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7739201
9 June 2023 Type not recorded
No type recorded · Station Eatons Neck · USCG Northeast District (CGD-NE) · Activity 7711465
6 October 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7571885
8 April 2022 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7427084
3 May 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7187867
1 March 2021 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7148328
1 July 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6990480
18 June 2020 Type not recorded
No type recorded · Station Eatons Neck · USCG Northeast District (CGD-NE) · Activity 6980540
13 May 2019 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6682776
26 February 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6632397
26 April 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6436146
15 February 2017 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6088594
23 January 2017 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6075396
21 June 2012 DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 4350785
13 February 2012 Drydock Exam · Deficiency Check · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4243960
18 August 2011 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 4126711
23 November 2010 Type not recorded
No type recorded · USCG Northeast District (dpi) F/V 4100 Processing · USCG Northeast District (CGD-NE) · Activity 3897559
20 October 2010 Type not recorded
No type recorded · USCGC LEGARE (WMEC 912) · Activity 3883032
23 February 2010 Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3686005
24 June 2008 Type not recorded
No type recorded · Station Oak Island · USCG East District (CGD-E) · Activity 3247172
24 June 2008 Type not recorded
No type recorded · Station Oak Island · USCG East District (CGD-E) · Activity 3247174
10 April 2008 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3181101
4 March 2008 Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3158104
3 April 2007 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2900594
3 April 2006 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2615347
30 March 2006 Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2612537
28 March 2006 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2610921
7 April 2005 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2328796
16 December 2004 Type not recorded
No type recorded · Station Oak Island · USCG East District (CGD-E) · Activity 2267543
4 June 2004 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2207726
19 April 2004 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2047705
10 March 2004 Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2021837
15 April 2003 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1773665
9 April 2002 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1602346
11 March 2002 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1492869
20 March 2001 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1389333
23 March 2000 Hull Examination · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1470793
5 April 1999 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1450256
30 September 1998 Inclining Experiment
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 802404
22 April 1998 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1124670
26 March 1998 Inclining Experiment · Hull Examination · Initial Certification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1436084

Deficiency record · 73

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 October 2025 Resolved
"The Rules concerning lights shall be complied with from sunset to sunrise..." Port sidelight is not operational. Fix port sidelight prior to operating between sunset and sunrise. 33 CFR 83.20(b)
Action required: 705 - Other - as specified
Resolved 8 October 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2025 Resolved
"Portable and semi-portable fire extinguishers must be inspected and maintained in accordance with NFPA 10..." Fire extinguisher at operating station had not been annually serviced. Service or replace portable fire extinguisher within 1 week. 46 CFR 176.810(b)(1)
Action required: 705 - Other - as specified
Resolved 8 October 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2025 Resolved
"A vessel not required to have a power driven fire pump by 181.300 must have at least three 9.5 liter buckets with an attached lanyard satisfactory to the cognizant OCMI placed so as to be easily available during an emergency. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket." Vessel is missing fire buckets. Replace fire buckets. 46 CFR 181.610
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2025 Resolved
"Remote fuel shutoff stations must be marked in clearly legible letters at least (1 inch) high indicated purpose of the valve and direction of operation." Fuel shutoff valve missing markings. Add markings. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 26 June 2026
Resolution: Received photo of fuel shutoff labelling
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 August 2024 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessels Hydrostatic release was expired. Replace prior to operating more than 3 miles.
Action required: 705 - Other - as specified
Resolved 25 September 2024
Resolution: Received photographic evidence of newly installed hydro release.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 August 2024 Resolved
Fuel shutoff valves: The shutoff valve at the tank must be operable from outside the compartment in which the valve is located. Vessel fuel shutoff valve was difficult to operate. Correct prior to credit dry dock. 46CFR182.455(b)(4)
Action required: 705 - Other - as specified
Resolved 9 October 2024
Resolution: Fuel shutoffs tested
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 August 2024 Resolved
For the purpose of flexibility only, flexible hose installed in lengths of not more than 760 millimeters (30 inches) and subject to pressures of not more than 35 kPa (5 psig), may meet the following requirements: (A) Suitable compression type connection fittings may be accepted;(B) Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. Any fuel hose that is over thirty inches must meet J1942. Replace fuel hose in excess of thirty inches, with J1942 hose prior to credit dry dock. 46CFR182.720(v)
Action required: 705 - Other - as specified
Resolved 9 October 2024
Resolution: Flex hose USCG type A
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 August 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessels MOB ladder is no longer serviceable. Replace prior to credit cry dock. 46CFR176.808
Action required: 705 - Other - as specified
Resolved 9 October 2024
Resolution: New MOB ladder
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 August 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to:(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel was missing cover for light in the laz.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2024
Resolved 25 September 2024
Resolution: Replaced light cover
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 August 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to:(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Batteries in the engine room needs the negative terminal replaced and the positive terminal cleaned of corrosion. 46CFR183.200(b)
Action required: 705 - Other - as specified
Due 27 August 2024
Resolved 25 September 2024
Resolution: Cleaned terminals.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 August 2024 Resolved
All other vessels must undergo an inspection for certification as specified in § 176.404 and annual inspection as specified in paragraph (b)(1) of this section.(1) Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. With the COI anniversary date of 15 APR 2022, vessel lapsed required inspection date deadline of 15 JUL 2024.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2024
Resolution: COI inspection complete and COI handed to operator in Person
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2023 Resolved
A vessel on which a pre-engineered fixed gas fire extinguisher system is installed must have have means to reset devices used to shut down. The vessel override operation to restart the vessel's engine was not operational. 46 CFR 181.420(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2023
Resolution: Vessel successful started engine in override mode.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 July 2023 Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. Vessel's horn was inoperable. 33 CFR 83.33(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2023
Resolution: Vessel purchased an air horn.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 July 2023 Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with attached lanyard and words FIRE BUCKET stenciled on the buckets. The vessel did not have fire buckets on board. 46 CFR 181.610
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2023
Resolution: Vessel provided photo documentation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 July 2023 Resolved
The frame or support of each portable fire extinguisher must be permanently attached to bulkhead or deck. Vessel's portable extinguishers where not placed in proper bracket. Temporary repair of securing extinguishers in proper location is approved until ordered brackets are installed. 46 CFR 181.500(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2023
Resolved 5 October 2023
Resolution: Vessel provided photo documentation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 July 2023 Resolved
Each lifeline on a ring life buoy must: Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Ring buoy must be replaced due to deterioration. 46 CFR 180.70(c)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2023
Resolved 11 July 2023
Resolution: Vessel replaced ring buoy; new buoy meets regulations.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 July 2023 Resolved
Rules in this subpart (Rules 20-31) shall be complied with in all weathers. Vessel's anchor light was not operational. Vessel must fix light prior to its need for operation. 33 CFR 83.20(a)
Action required: 705 - Other - as specified
Resolved 11 July 2023
Resolution: Vessel repaired light.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 July 2023 Resolved
A life float APPROVED under approval series 160.027 must meet the requirements for buoyant apparatus. The Lifefloat and buoyant apparatus are not in good condition, required to be replaced. Replacements must comply with Table 180.200(c) for Limited Coastwise route. 46 CFR 180.200(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2023
Resolved 4 October 2023
Resolution: Attending MI approved life floats on board.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2021 Resolved
Master shall conduct sufficient drills and log/document. Logs on board have no drills logged since June 2020. Cite - 46CFR185.520(a)/(f) and 185.524 Action - 701 C (prior to carrying passenger).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2021
Resolution: Received objective evidence attesting to rectification of drills being conducted and logged.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 3 May 2021 Resolved
Visual bilge high level alarm required at operating station. Visual bilge alarm for engine and rudder space was inoperable. Cite - 46CFR182.530(a) Action - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2021
Resolution: Received objective evidence attesting to rectification of bilge high level alarm indicator.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 May 2021 Resolved
Painter line for life floats water light are required to be 18ft. Painter lines for life floats were appx 3ft. Cite - 46CFR180.175(f)(4) Action 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2021
Resolution: Received objective evidence attesting to rectification of painter line length.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 13 May 2019 Resolved
Operations of transmitters of any ship station must require a commerical radio operators license or permit. Master did not have FCC Marine Operator Permit avialable. Vessel is restricted to 1000 ft from shore. 47 CFR 80.159
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 14 May 2019
Resolution: Received email with valid FCC Radio Operators Permit.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 February 2019 Resolved
Installed fire protection system delinquent in servicing. Require updated servicing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2019
Resolution: Received picture of fireboy servicing.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 February 2017 Resolved
Prove proper operation of fixed firefighting system prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 22 February 2017
Resolution: Attended vessel and O/O proved proper operation of Fireboy
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 15 February 2017 Resolved
Replace pull pin on manual FF Pull Handle at operating station. Old pin was corroded inside the handle.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 22 February 2017
Resolution: Attended vessel and verified newly installed pull handle for fireboy
Lifesaving › Lifefloat › Paddle
Issued 21 June 2012 Resolved
Repair/replace paddels for life floats.
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 2 July 2012
Lifesaving › Lifefloat › Markings
Issued 21 June 2012 Resolved
Repair/replace retroflective tape of lifefloat
Action required: 705 - Other - as specified
Resolved 2 July 2012
Lifesaving › Lifebuoys › Serviceable
Issued 21 June 2012 Resolved
Repair/replace retroflective tape on lifebuoy
Action required: 705 - Other - as specified
Resolved 2 July 2012
Lifesaving › Lifefloat › Float-free Link
Issued 21 June 2012 Resolved
Replace float free link on lifefloat. Vessel capacity reduced to 16 total persons onboard.
Action required: 705 - Other - as specified
Resolved 2 July 2012
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 21 June 2012 Resolved
Obtain FCC radio cetificate for the vessels radio(s).
Action required: 705 - Other - as specified
Resolved 30 July 2012
Resolution: Certificate obtained.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 10 April 2008 Resolved
Provide flame cup or fuel filter
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2008
Resolution: Installed flame cup
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 April 2008 Resolved
Provide new hydrostatic release for EPIRB.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2008
Resolution: Installed new hydro
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 10 April 2008 Resolved
Provide serviceable fixed fire fighting system.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2008
Resolution: Installed new system.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 April 2008 Resolved
Properly afix light in aft compartment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2008
Resolution: Re mounted light.
Engineering › Steering Gear System › Linkage
Issued 10 April 2008 Resolved
Replace rod end for hydraulic steering ram.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2008
Resolution: Replaced rod end.
Engineering › Fuel Oil Service System › Valve, Control
Issued 10 April 2008 Resolved
Replace fuel shut off valves.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2008
Resolution: Serviced shut off valves and operated sat.
Documentation › Safety Management System › Potential Emergency Situations ID Procedures
Issued 10 April 2008 Resolved
Provide emergency broadcast placard.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2008
Resolution: Installed new placard.
Stability › Watertight Integrity › General
Issued 10 April 2008 Resolved
Make collision bulkhead hatch watertight.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2008
Resolution: Secured hatch.
Documentation › Markings/Placards › Warning Signs
Issued 10 April 2008 Resolved
Re stencil emergency escape hatch and add "keep clear" provide illuminated arrows and lettering. Provide step for egress.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2008
Resolution: Completed all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2007 Resolved
Provide metal support brackets for wire runs
Condition: Improper Installation
Due 17 April 2007
Resolved 5 April 2007
Resolution: Metal supports installed.
Engineering › Fuel Oil Service System › Filter
Issued 3 April 2007 Resolved
Provide/install flame cup for stbd fuel filter.
Condition: Improper Installation
Due 17 April 2007
Resolved 5 April 2007
Resolution: Flame cup installed.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 3 April 2007 Resolved
Stencil new PFD's with vessel name.
Condition: Improper Installation
Due 17 April 2007
Resolved 5 April 2007
Resolution: PFD''s stenciled.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 April 2007 Resolved
Provide lifeline for ring buoy.
Condition: Improper Installation
Due 17 April 2007
Resolved 5 April 2007
Resolution: Lifeline provided.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 3 April 2007 Resolved
Provide waterlight for new PFDs
Condition: Improper Installation
Due 17 April 2007
Resolved 5 April 2007
Resolution: Water lights provided.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 3 April 2007 Resolved
Provide donning placards for PFD's.
Condition: Improper Installation
Due 17 April 2007
Resolved 5 April 2007
Resolution: Donning placards provided.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 April 2007 Resolved
Provide proof of enrollment in drug consortium.
Condition: Unknown
Due 17 April 2007
Resolved 5 April 2007
Resolution: Proof of enrollment provided.
Lifesaving › Inflatable Buoyant Apparatus › Float Free
Issued 3 April 2006 Resolved
Hydrostatic release on IBA has expired (Note: IBA is carried as an additional appliance and is not required.)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2006
Resolution: O/O purchased new Hydro to be installed on IBA
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 3 April 2006 Resolved
IBA is out of date for servicing (Note: IBA is carried as an additional appliance and is not required).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2006
Resolution: O/O to remove IBA until servicing can be performed.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 3 April 2006 Resolved
Hydrostatic release for EPIRB has expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2006
Resolution: O/O purchased new hyrdro for EPIRB
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 April 2006 Resolved
O/O to prove proper operation of Stbd Navlight, bow light, and stern/anchor light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2006
Resolution: O/O replaced all bulbs and all operated as normal.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 3 April 2006 Resolved
O/O to repair or replace STBD BA.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2006
Resolution: O/O purchase new BA and installed on vsl.
Fire Fighting › Fire Bucket › Availability
Issued 3 April 2006 Resolved
O/O to provide (03) fire buckets
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2006
Resolution: O/O provided (03) fire buckets w/ proper stencilling and lanyards.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 3 April 2006 Resolved
VSL must provide all plastic trash recepticles w/ metal liners or replace w/metal cans.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2006
Resolution: Metal liners provided.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 28 March 2006 Resolved
Provide proof of servicing for IBA or remove.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2006
Resolution: Purchased new IBA
Lifesaving › Launching Appliances › Release Mechanism
Issued 28 March 2006 Resolved
Replace hydrostatic release for EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2006
Resolution: Installed new hydrostat for EPIRB
Lifesaving › Launching Appliances › Release Mechanism
Issued 28 March 2006 Resolved
Replace hydrostatic release for IBA or remove
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2006
Resolution: Purchased new Buoyant Apparatus.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 March 2006 Resolved
Prove proper operation of stbd, fore and stern lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2006
Resolution: Fixed all lighting.
Lifesaving › Lifefloat › Serviceable
Issued 28 March 2006 Resolved
Repair or replace stbd bottom buoyant apparatus.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2006
Resolution: Purchased new Buoyant apparatus.
Fire Fighting › Fire Bucket › Availability
Issued 28 March 2006 Resolved
Provide (03) fire buckets.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2006
Resolution: Provided 3 fire buckets.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 28 March 2006 Resolved
Provide non combustible trash receptacle.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2006
Resolution: Purchased metal liner for can.
Fire Fighting › Fire Bucket › Lanyard
Issued 31 March 2005 Resolved
No lanyards on fire buckets.
Condition: Improper/Lack of Maintenance
Due 14 April 2005
Resolved 31 March 2005
Resolution: O/O put lanyards on firebuckets.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 31 March 2005 Resolved
O/O to provide proof of employee enrollment
Condition: Unknown
Due 14 April 2005
Resolved 1 April 2005
Resolution: O/O faxed list of employees enrolled.
Documentation › Certificates/Documents › Stability Letter
Issued 31 March 2005 Resolved
Post stability letter onboard the vessel
Condition: Unknown
Due 14 April 2005
Resolved 31 March 2005
Resolution: O/O retrieved stability letter from documents and posted onboard vsl.
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 March 2005 Resolved
Prove proper operation of fuel shut off valves
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2005
Resolution: O/O repaired fuel shut off linkage to the satisfaction of attending marine inspectors.
Communications › Alarms/Indicators › Bilge Alarm
Issued 31 March 2005 Resolved
High water alarm visual warning lamps did not function.
Condition: Improper/Lack of Maintenance
Due 14 April 2005
Resolved 7 April 2005
Resolution: O/O installed two new light bulbs in the warning lamps
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 March 2004 Resolved
Bulkhead pipe penetration in fwd compartment needs to be sealed.
Action required: 705 - Other - as specified
Resolved 10 March 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 March 2004 Resolved
Metal supports every 24"
Action required: 705 - Other - as specified
Resolved 10 March 2004
Lifesaving
Issued 20 March 2001 Resolved
Vessel restricted to the carriage of 26 passengers for coastwise route until adequate survival craft is obtained in accordance with 46 CFR 180.204(d).
Condition: Unknown
Due 14 May 2001
Resolved 18 May 2001
Lifesaving
Issued 20 March 2001 Resolved
PROVIDE ADEQUATE PRIMARY LIFESAVING SURVIVAL CRAFT IN ACCORDANCE WITH 46 CFR 180.200(C).
Condition: Unknown
Due 14 May 2001
Resolved 18 May 2001
Navigation
Issued 20 March 2001 Resolved
PROVE PROPER OPERATION OF EMERGENCY STEERING WITH TILLER ARM.
Condition: Unknown
Due 4 April 2001
Resolved 9 April 2001
Lifesaving
Issued 23 March 2000 Resolved
Install high level bilge alarm in lazarette, with indicator light and audible alarm at operating station.
Condition: Unknown
Due 30 March 2000
Resolved 6 April 2000
Construction/Loadline
Issued 26 March 1998 Resolved
MAKE HATCH TO STORAGE COMPARTMENT IN WELL DECK WATERTIGHT.
Condition: Unknown
Due 26 April 1998
Resolved 22 April 1998
Electrical
Issued 26 March 1998 Resolved
PROPERLY SUPPORT WIRE RUN IN CABIN.
Condition: Unknown
Due 26 April 1998
Resolved 22 April 1998

Casualty record · 4

4 June 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 2207726
18 August 2011Routine · role: Involved in a Marine Casualty · activity 4126711
7 January 2013Routine · role: Involved in a Marine Casualty · activity 4512170
11 February 2013Routine · role: Involved in a Marine Casualty · activity 4531324
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 3

THE NEW DOUBLE (R) (2004), THE NEW DOUBLE R (2011), DROP OFF (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.