PESCADOR III

PESCADOR III is a 1968 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in November 2021, along with 21 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2021. Most recent: inspection, 3 November 2021.

Built
1968
Last inspected
3 November 2021
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 November 2021
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WY5027
Flag
UNITED STATES
Maury page id
psix-45975

Documentation record

Registered dimensions (L × B × D)46.8 ft × 16.4 ft × 6.3 ft
Registered tonnagegross 36 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARLTON E THOMPSON · OCEAN CITY, FL, UNITED STATES · built 1968
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Regulatory (Subpart C or D), Gross Ton
28 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

13 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

3 November 2021 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7344658
4 December 2020 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7106425
26 May 2020 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6962616
23 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6822709
5 September 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6805385
7 May 2019 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6679324
5 February 2019 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6622558
28 August 2018 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6526175
19 September 2017 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6273733
15 August 2017 Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6241057
4 April 2017 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6112959
14 June 2016 Administrative Inspection · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5904209
10 May 2016 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5896693

Deficiency record · 21

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 December 2020 No resolution recorded
Inspect vessel for renewal of certification in accordance with 46 CFR 176.404. Vessel is overdue for 2020 annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 23 September 2019 Resolved
Vsl is required to have on board + posted in a conspicous place, placards containing instructions for the donning + use of lifejackets. Vsl is missing the required placard. 46 CFR 185.516 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 26 May 2020
Resolution: Proper placard installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 September 2019 Resolved
Vsl is required to have adequate emergency lighting that automatically actuates upon the failure of the main lighting system for lounge areas below main deck. The vsl passenger accommodation space located below main deck has no emergency lighting installed. 46 CFR 184.30-5 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 26 May 2020
Resolution: Emergency lighting installed and tested; all sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2019 Resolved
Vsl is required to mark all escape hatches + other emergency exits EMERGENCY EXIT KEEP CLEAR in 1 inch letters on both sides. The escape hatch in the passenger accommodation space is not marked on either side. 46 CFR 185.30-15 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 26 May 2020
Resolution: Escape hatch labeling properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2019 Resolved
Vsl has many appliances on board the vessel powered by portable electrical cords in both the crew lounge and wheel house. Vsl should install permanent outlets in the number needed to power equipment and/or appliances deemed necessary for ship operation. 46 CFR 183.01-5 50c
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2019
Resolved 26 May 2020
Resolution: Electrical cords removed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 23 September 2019 Resolved
During in service inspection MI discovered multiple corroded fastners and keel and transverse frames along w/ planking that appeared to be pulling away. Provide 3rd party report attesting to the condition of the hull until the next scheduled drydock. 46 CFR 176.840 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2019
Resolved 26 May 2020
Resolution: Accepted 3rd party report on fastner condition, identified items repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 September 2019 Resolved
Vessels life float is showing signs of unserviceability and missing any identification labels. Vessel shall not carry more than 6 passengers until life float is replaced and shall be replaced within 14 days.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2019
Resolved 19 September 2019
Resolution: New life floates installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 September 2019 Resolved
Replace aft life ring light line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2019
Resolved 19 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 September 2019 Resolved
Properly secure life floats weak link
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2019
Resolution: Weak link properly secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 August 2018 Resolved
Repair or replace the starboard side bow railing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2018
Resolved 13 September 2018
Resolution: Repaired starboard railing installing new screws for support.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 August 2018 Resolved
Provide updated chart for area of operations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2018
Resolved 13 September 2018
Resolution: Provided chart for ocean's route.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 August 2018 Resolved
Provide copy of monthly/quarterly crew training logs.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2018
Resolved 13 September 2018
Resolution: Provided a copy of the training log.
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 August 2017 Resolved
Fuel shut off valve needs a cable or leaver so it can be reached properly.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2017
Resolved 16 August 2017
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 August 2017 Resolved
Battery date expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2017
Resolved 16 August 2017
Lifesaving › Lifebuoys › Serviceable
Issued 15 August 2017 Resolved
Life Ring Buoy needs new habd line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2017
Resolved 16 August 2017
Lifesaving › Lifefloat › Netting
Issued 14 June 2016 Resolved
Replace identified lifefloat straps
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 2 August 2016
Resolution: Vessel replaced straps
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 June 2016 Resolved
Provide ring buoy line and light line
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 14 June 2016
Resolution: Vessel provided line.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 June 2016 Resolved
Replace/Repair fwd bilge alarm (alarm is in excess of requirment)
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 14 June 2016
Resolution: Vessel replaced bilge alarm
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 June 2016 Resolved
Repair STBD side fwd deck railing
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 14 June 2016
Resolution: Vessel repaired railing
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 June 2016 Resolved
Provide DAPI program covered employee's list.
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 14 June 2016
Resolution: Vessel provided list
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 May 2016 Resolved
Complete credit COI exam.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 14 June 2016
Resolution: Completed credit COI exam.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.