MAURY USCG vessel records
← All vessels

MERRIMAC II

MERRIMAC II is a 1968 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in October 2024, along with 14 deficiencies.

Records from 2016 to 2024. Most recent: inspection, 15 October 2024.

Built
1968
Last inspected
15 October 2024
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 October 2024
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK9608
Flag
UNITED STATES
Maury page id
psix-45978

Documentation record

Registered dimensions (L × B × D)51.2 ft × 14.1 ft × 6.2 ft
Registered tonnagegross 38 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSAYVILLE MARINE CENTER INC · SAYVILLE, NY, UNITED STATES · built 1968
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHERRYFIELD, ME
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

15 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

15 October 2024 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8019134
21 August 2024 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7986301
24 January 2023 Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7626223
13 September 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7558141
14 June 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7165419
27 November 2020 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7101266
30 December 2019 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6880688
23 July 2019 COI Inspection · Administrative Inspection · Simplified Stability Test · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6759226
16 April 2019 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6663816
14 December 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6597272
12 December 2018 SIP Inspection/Audit
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6434124
6 December 2017 SIP Inspection/Audit
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6323565
18 May 2017 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6148958
3 November 2016 SIP Inspection/Audit
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6037294
8 September 2016 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5995536

Deficiency record · 14

02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 19 August 2019 Resolved
Remove crossover between port and starboard fuel tanks and install alum. caps or plugs in crossover openings. To be corrected prior to 2020 operating season.
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 11 March 2020
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 19 August 2019 Resolved
Install sounding tube or other means to determine fuel tank levels. To be corrected no prior to 2020 operating season.
Action required: 705 - Other - as specified
Due 1 July 2020
Resolved 25 June 2020
Resolution: Installed sending units and guages at helm station.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 August 2019 Resolved
Remove/Replace corroded conduit and make repairs to wiring penetrations on watertight bulkheads. To be corrected prior to 2020 operating season.
Action required: 705 - Other - as specified
Due 1 July 2020
Resolved 6 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2019 Resolved
Provide discharge hose for portable bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 19 August 2019
Resolution: Vessel provided discharge hose
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2019 Resolved
Install headed pin or bolt on starboard steering linkage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 19 August 2019
Resolution: Vessel provided bolt to starboard steering linkage.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 15 August 2019 Resolved
Ensure all screws are in place/tight on hand rails to passenger cabin from aft deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 19 August 2019
Resolution: Rails were secured to vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2019 Resolved
Ensure fuel tank is grounded (and fills are grounded to tank if fitted with in-line hose).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 19 August 2019
Resolution: Fuel tank ground was added to vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 15 August 2019 Resolved
Provide means to determine fuel tank levels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 19 August 2019
Resolution: Vessel purchased fuel tank gauge and provided means.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 15 August 2019 Resolved
Complete sealing of electrical conduits at WTB's to maintain subdivision.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 19 August 2019
Resolution: Vessel filled conduit line with filler.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 August 2019 Resolved
Prove operation of stern light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 19 August 2019
Resolution: Sternlight was operational.
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 15 August 2019 Resolved
Post emergency procedures at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 19 August 2019
Resolution: Emergency instructions were posted at the operating station
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 14 December 2018 Resolved
Port and starboard pilot house wondows cracked
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 21 January 2019
Resolution: Replaced both Port and Starboard PH windows
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 14 December 2018 Resolved
Clean oily water in engine room bilge
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 January 2019
Resolved 21 January 2019
Resolution: Engine room bilges cleaned
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 14 December 2018 Resolved
Repair keel area around shaft/ props, worm shoot.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 14 January 2019
Resolution: Scrapped area at the bottom of the keel was sanded, dried out, repaired and re-painted IAW 7-95.

Ownership record