MAURY USCG vessel records Sign in
← All vessels

YL CONFIDENCE

YL CONFIDENCE is a 1996 freight ship. The Coast Guard has recorded 27 inspections since 1997, most recently in December 2008, along with 14 deficiencies and 6 operational controls.

Records from 1997 to 2008. Most recent: inspection, 30 December 2008.

Built
1996
Last inspected
30 December 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9169809 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
459812
Flag
BAHAMAS, THE
—
Maury page id
psix-459812

Inspections, by type

…with no type recorded15
Years with a record 10 calendar years (1997–2008)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6714 - Convention (Subpart B), Gross Ton
2888 - Convention (Subpart B), Net Ton
8491 - Dead Weight, Ton
12023 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

30 December 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3386468
18 November 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3365428
29 October 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3354060
21 February 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3151274
10 February 2008 PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3139787
28 June 2007 Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2966379
28 June 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2976568
27 June 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2976009
1 May 2006 Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2637998
4 June 2005 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2379078
22 May 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2364683
16 May 2005 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2359220
22 September 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2202450
21 June 2004 MTSA/ISPS Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2106357
30 March 2004 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2034489
30 March 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2034836
29 March 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2033186
9 February 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2003094
8 December 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1960665
25 November 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1954062
27 October 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1937328
11 May 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1615609
16 July 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 93411
30 November 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 422976
3 October 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 421002
1 October 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 408521
26 August 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 407305

Deficiency record · 14

Fire Fighting › Fire Pumps › Gland Sealing
Issued 10 February 2008 Resolved
The #2 fire pump is leaking water excessively at the connection of the fire pump and the discharge line.
Action required: 705 - Other - as specified
Due 17 February 2008
Resolved 21 February 2008
Resolution: Received class report from BV satisfying requirement.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 10 February 2008 Resolved
The free-fall lifeboat has 10 food rations which have lost their vacuum seal.
Action required: 15 - Rectify deficiencies by next port
Resolved 21 February 2008
Resolution: Received class report from BV satisfying requirement
Electrical › Electrical Distribution System (service) › Switch
Issued 29 June 2007 Resolved
Various electrical devices in the Forecastle were found deficient, specifically light switches broken, distribution panels with openings requiring blanks and loose wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2007
Resolved 29 June 2007
Resolution: All electrical Items were corrected and found to the satisfaction of the Marine Inspector.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 28 June 2007 Resolved
Galley fire doors (class A boundry) missing self-closing devices whick would allow fire to spread pass fire boundry.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 June 2007
Resolved 10 February 2008
Resolution: Verified proper repairs made to the galley class A fire door and witnessed the operation of the self closing devices.
Construction/Loadline › Structures › Door
Issued 28 June 2007 Resolved
Starboard watere tight door to anchor windless deck is sprung and will not properly seal.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 June 2007
Resolved 10 February 2008
Resolution: Reviewed class report and verified the proper closure of the starboard watertight door.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 1 May 2006 Resolved
Site glass on discharge to slop tank is broken. A temporary repair has been made to stop leak. Discontinue the use of OWS untill proper repairs are made.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 10 February 2008
Resolution: No class report could be obtained during examination due to the fact that the previous owner retrieved it. The site glass on the discharge pipe from the OWS to the bilge holding tank was in good condition.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 1 May 2006 Resolved
Hevey residue oil throughout the engine room. Engineroom requires extensive house keeing while not interfering with adequate restperiods for watchstanders as per STCW.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 10 February 2008
Resolution: No class report could be obtained during examination due to the fact that previous owner retrieved it. Good house keeping practices were observed during examination, as well as satisfactory level of cleanliness throughout the machinery spaces.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 May 2006 Resolved
Exterior deck lights and lighting for lifeboats are not working, missing, or wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 10 February 2008
Resolution: No class report could be obtained due to the fact that the previous owner retrieved it. on the other hand, all lifeboat deck lights were operating properly.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 November 2003 Resolved
Door to laundry room cannot be properly closed. Replace door to laundry room correct prior to 25DEC03. Correct to the satisfaction of the certificate issuing authority. Provide report to MSO via fax.
Due 25 December 2003
Resolved 25 December 2003
Resolution: Report provided.
Lifesaving
Issued 3 October 1998 Resolved
ENGINE ROOM ALARM SYSTEM TRANSFORMER RECTIFIER IS INOPERATIVE; MAKE REPAIRSTO SATISFACTION OF CERTIFICATE ISSUING AUTHORITY IAW SOLAS 74 (AMENDED) CHAPTER II-1/51.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Documentation
Issued 26 August 1997 Resolved
Prior to departure, provide proper documentation to include proper dangerous cargo manifest and proper shipping documents for containers #XRTU856157-7 and #SMLU490803-5 (both marked with flammable placards and not manifested on DCM).
Condition: Unknown
Due 26 August 1997
Resolved 2 September 1997
Documentation
Issued 26 August 1997 Resolved
Prior to bunkering in U.S waters properly ammend Oil Transfer Procedures tobe IAW 33 CFR 155.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Navigation
Issued 26 August 1997 Resolved
Prior to entering U.S waters provide/post emergency steering instructions at steering compartment.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Documentation
Issued 26 August 1997 Resolved
Prior to bunkering in U.S. Waters, properly ammend SOPEP as to reflect listof Port specific points of contact.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997

Ownership record