MAURY USCG vessel records Sign in
← All vessels

GENCO WISDOM

GENCO WISDOM is a 1997 freight ship. The Coast Guard has recorded 17 inspections since 1999, most recently in March 2016, along with 13 deficiencies and 3 operational controls.

Records from 1999 to 2016. Most recent: inspection, 8 March 2016.

Built
1997
Last inspected
8 March 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9149380 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
459815
Flag
HONG KONG
—
Maury page id
psix-459815

Inspections, by type

…with no type recorded5
Years with a record 10 calendar years (1999–2016)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it26094 - Convention (Subpart B), Gross Ton
16177 - Convention (Subpart B), Net Ton
54318 - Displacement, Ton
47180 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

8 March 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5829386
25 February 2016 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5821645
15 August 2015 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5211904
17 January 2012 PII Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4219792
11 January 2012 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4220107
16 November 2010 Deficiency Check · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3892134
2 December 2009 PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3643167
11 August 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3295709
22 May 2008 Ballast Water Examination · NPV Safety Exam · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3208633
21 May 2007 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2936037
20 May 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2935253
17 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2430087
6 July 2005 NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2416600
2 October 2003 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1920008
23 September 2003 Type not recorded
No type recorded · Maritime Safety & Security Team Seattle (91101) · Activity 1916831
25 March 2003 Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1759685
29 June 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 430142

Deficiency record · 13

Documentation › Certificates/Documents › IOPP Certificate
Issued 10 August 2015 Resolved
0150 - IOPP - No change shall be made w/o sanction of Admin. Vessel installed MEPC .107(49) oil content monitor to a MEPC .60(33) separator which did not reflected on IOPP. Provide clarification from RO. - MARPOL 73/78 Annex 1/6.4.2
Action required: 705 - Other - as specified
Due 29 August 2015
Resolved 17 August 2015
Resolution: Received documentation from RO satisfying the requirement.
Operations/Management › Pollution › Control of Garbage
Issued 10 August 2015 Resolved
2120 - GMP - Every ship shall have a GMP which crew shall follow. Crew not following GMP in E/R or C/E posted instructions. Specifically oiled rags left on M/E, S/G, W/O drains, and inserted under main air compressor in W/O drainage system. - MARPOL 73/78 Annex V/10.2
Action required: 705 - Other - as specified
Due 29 August 2015
Resolved 17 August 2015
Resolution: Received documentation from vessel satisfying the requirement.
Construction/Loadline › Structures › Air Pipe
Issued 16 November 2010 Resolved
1275; Air vents leading into the fore peak tank are wasted. Wastage can be scene inside the forward Bos'n store, 17 A/B.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2010
Resolved 19 November 2010
Resolution: Repaired to the satisfaction of Class.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 16 November 2010 Resolved
1275; Air vent leading into fuel tank port side located inside hydraulic room is wasted, 17A/B.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2010
Resolved 19 November 2010
Resolution: Repaired to the satisfaction of Class.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 November 2010 Resolved
0710; The crew is using spaces inside the accommodation for storage of items which can compromise crew safety. 1, electrical cable truck bridge deck excess items storage of movies and library, 2, #4 locker, boat deck, storage of flammable items, 3, pipe duct truck , upper deck starboard, excess items, 4, radio room, Capt deck, make shift laundry in water closet, 17 A/B.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2010
Resolved 19 November 2010
Resolution: Repaired to the satisfaction of Class.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 November 2010 Resolved
0600; The lifejackets and immersion suits are not readily available for immediate use in the forward Bos'n store. Drums and other items are blocking their way, 17 A/B.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2010
Resolved 19 November 2010
Resolution: Repaired to the satisfaction of Class.
Accommodation/Occupational Safety › Ventilation › General
Issued 16 November 2010 Resolved
0300; Doors leading outside the accommodation spaces are wasted, worn or missing proper locking devices, 1, Captain deck starboard door aft hinges, 2, Captain deck port door aft frame wasted, 3, bridge deck starboard door frame wasted, 4, port door leading to L/B, frame wasted, locking device not working and port light glass frame wasted, 17 A/B.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2010
Resolved 19 November 2010
Resolution: Repaired to the satisfaction of Class.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 16 November 2010 Resolved
0900; Portable davit for starboard pilot arrangement worn, cannot be sued, 17 A/B.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2010
Resolved 19 November 2010
Resolution: Repaired to the satisfaction of Class.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 November 2010 Resolved
1400; The following items were found in the engine room, 1, OWS; patch on pipe leading from upper to lower chamber, 2, #2 Generator discharge pipe patched lube oil cooler salt water line, 17 A/B.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2010
Resolved 19 November 2010
Resolution: Repaired to the satisfaction of Class.
Lifesaving › Lifeboat › Propulsion Engine
Issued 16 November 2010 Resolved
0610; Operational readiness; port lifeboat becket lines wasted and cap for salt water cooling of engine wasted, 17 A/B.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2010
Resolved 19 November 2010
Resolution: Repaired to the satisfaction of Class.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 16 November 2010 Resolved
0330; Sewage tank level probe, wastage around probe.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2010
Resolved 19 November 2010
Resolution: Repaired to the satisfaction of Class.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 2 December 2009 Resolved
Chief officer does not have Chinese GMDSS license nor an application. STCW 95 REG 1/4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2009
Resolution: Received photo copy of chief mates GMDSS license.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 22 May 2008 Resolved
Vessel is to conduct a hydrostatic test using liquid prior to bunkering in U.S. waters, in accordance with 3 CFR 156.170.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 August 2008
Resolution: Received proper documentation satisfying the requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.