Records from 2008 to 2026. Most recent: inspection, 26 May 2026.
Inspection history · 17
26 May 2026
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8373179
7 October 2025
Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8254586
19 June 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8153785
6 June 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7930366
17 October 2023
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7816671
17 May 2023
In-Service Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7715100
14 October 2022
Examination of Repairs · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7577350
24 May 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7473747
8 September 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7307472
4 May 2021
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7189537
15 March 2021
Drydock Extension
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7162634
23 September 2020
Inclining Experiment
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7072657
13 July 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7017702
20 May 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6698734
8 May 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6402547
17 May 2017
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6142611
3 May 2016
Internal Structural Exam · Drydock Exam · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5868539
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 June 2024
Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. COI was posted inside the wheelhouse, not accessible to passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2024
Resolution: Item addresssed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2024
Resolved
Each individual bilge suction shall be fitted with a suitable bilge strainer having an open area of not less than three times at of the suction pipe. The strainer in hold 7 was not fully secured.
Action required: 10 - Deficiency Rectified
Resolved 12 July 2024
Resolution: Item addressed.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 6 June 2024
Resolved
The owner, charterer, master, or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 122.510, when applicable, the duties listed in the station bill required by § 122.514. Vessel crew were not familiar with responding to emergencies.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2024
Resolution: Item addressed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The vessel’s flexible fuel supply line has been spliced so that two flexible lines are joined creating a safety hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2024
Resolution: Item addressed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2024
Resolved
At least one ring buoy must be fitted with a floating waterlight. Waterlight separately was stored separately, inside the wheelhouse.
Action required: 10 - Deficiency Rectified
Resolved 12 July 2024
Resolution: Item addressed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2024
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. The starboard fuel filter is leaking creating a fire hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2024
Resolution: Item addressed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 June 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Kit has several expired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2024
Resolution: Item addressed.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 6 June 2024
Resolved
The master or person in charge of a ship shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. Vessel doesn’t have garbage placard posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2024
Resolution: Item addressed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2024
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Some bins aren’t correctly marked with the number of life jackets
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2024
Resolution: Item addressed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Two kids lifejackets were stored with adult lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2024
Resolution: Item addressed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2024
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. Vessel life jackets onboard have with another vessel’s name marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2024
Resolution: Item addressed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 May 2022
Resolved
Each life jacket kept in a stowage container must be readily available. Damaged PFD storage bin to be repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2022
Resolution: Received photographic evidence of reapaired PFD storage bin.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 September 2021
Resolved
Crop and renew areas found with pitting or uniform corrosion in excess of allowable (25%) from original plate thickness as shown on UT report. Size of areas of plating renewed to be verified by UT to ensure all degraded steel encompassed by repairs. Repairs to completed to the satisfaction of the attending marine inspector. Repairs deferred and to be completed NLT 01OCT22.
Action required: 705 - Other - as specified
Due 1 October 2022
Resolved 17 October 2023
Resolution: Received report of NDT. Attached.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 September 2021
Resolved
Repair fractured weld in port lazarette overhead to the satisfaction of the attending marine inspector. Repairs deferred and to be completed NLT 01OCT22
Action required: 705 - Other - as specified
Due 1 October 2021
Resolved 1 October 2021
Resolution: Weld v'd out and renewed. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 September 2021
Resolved
Repair or renew degraded port and starboard sewage holding tanks to the satisfaction of the attending marine inspector. Repairs deferred and to be completed NLT 01OCT22
Action required: 705 - Other - as specified
Due 1 October 2022
Resolved 19 October 2022
Resolution: Received ST&I report and photographic evidence of repair. All Sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 May 2021
Resolved
Make watertight bulkhead between compt 3 and 4 watertight (hole)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 2 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 May 2021
Resolved
Repair inoperable port navigational sidelight
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 1 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 May 2021
Resolved
Provide 30 additional adult life jackets and label new location, provide 1 additional child life jacket. Passenger carraige capacity reduced accordingly until corrected
Action required: 705 - Other - as specified
Resolved 26 October 2021
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 8 May 2018
Resolved
Label upper deck life jacket stowage comtainers 46CFR122.604(f).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 11 June 2018
Resolution: Labeled Storage
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 8 May 2018
Resolved
Reinstall captive chains on life jacket stowage containers 46CFR115.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 11 June 2018
Resolution: Re-installed captive chains
Fire Fighting › Fire Hydrants › Condition
Issued 8 May 2018
Resolved
Replace/repair fire station valve on the upper deck 46CFR118.310
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 11 June 2018
Resolution: Replaced valve
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 3 May 2016
Resolved
31 Adult PFD's were found to be inserviceable to age as required by 46CFR180.71. Vessel is restricted to 331 total persons.
Action required: 705 - Other - as specified
Resolved 14 June 2016
Resolution: Replaced in kind.
Fire Fighting › Fire Hoses › Condition
Issued 3 May 2016
Resolved
Fire hose was found to have a slight leak and will be replaced.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 14 June 2016
Resolution: Replaced in kind.
Engineering › Bilge Water Management System › Interface Detector
Issued 3 May 2016
Resolved
Vessel must prove proper opperation of void 4 bilge high water alarm as required by 46CFR182.530.
Action required: 705 - Other - as specified
Due 22 June 2016
Resolved 14 June 2016
Resolution: Replaced in kind.