PRINCE WASHINGTON

PRINCE WASHINGTON is a 1968 passenger vessel (uninspected). The Coast Guard has recorded 67 inspections since 1985, most recently in May 2025, along with 173 deficiencies and 1 operational control.

Records from 1985 to 2025. Most recent: inspection, 6 May 2025.

Built
1968
Last inspected
6 May 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-46003

Inspections, by type

…with no type recorded5
Years with a record 36 calendar years (1985–2025)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 67

6 May 2025 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8129359
16 May 2024 Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7913989
16 April 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7896513
16 April 2024 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7901280
1 November 2023 Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7818760
1 June 2021 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7211704
8 March 2021 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7149082
28 May 2020 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6960894
5 December 2019 Hull Examination · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6868652
8 March 2019 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6638783
27 November 2017 Hull Examination · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6313337
31 October 2017 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6294082
14 November 2016 Examination of Repairs · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6037378
12 August 2016 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5970606
28 October 2015 Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5764391
28 August 2015 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5231301
17 June 2014 Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 4892273
17 July 2012 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 4381477
8 July 2009 Annual Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam · Simplified Stability Test · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3529266
15 July 2008 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3268630
3 October 2007 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3072059
22 June 2006 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2688055
18 July 2005 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2431760
1 November 2004 Simplified Stability Test
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2239754
14 October 2004 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2224016
29 September 2004 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2213259
23 July 2004 Deficiency Check · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2160620
15 July 2003 Periodic Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1847227
20 August 2002 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1664789
26 June 2002 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1637039
14 June 2002 Hull Examination · Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1630893
23 July 2001 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1397685
6 October 2000 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1362173
22 August 2000 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1054168
7 August 2000 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1379154
8 September 1999 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 783725
16 August 1999 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1388883
23 July 1998 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1368945
17 October 1997 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1113680
9 September 1997 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1121724
13 August 1997 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1118441
19 June 1997 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1404402
16 January 1997 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1098585
7 August 1996 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1085226
8 May 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1082202
28 November 1995 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1192046
8 September 1995 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 879146
10 August 1995 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 881024
14 September 1994 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1177624
17 August 1994 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 868610
13 August 1993 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 848268
17 August 1992 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1245795
24 June 1992 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1267268
25 October 1991 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1248046
6 September 1991 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1254149
29 October 1990 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 926753
9 October 1990 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1235103
2 October 1990 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1240168
31 December 1989 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1230551
5 September 1989 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1194892
15 August 1988 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1040268
4 August 1987 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1338764
22 August 1986 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1334372
24 July 1986 Credit Drydock
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 993200
10 September 1985 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 988400
13 June 1985 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1289179
16 January 1985 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 974546

Deficiency record · 173

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 April 2024 Resolved
The vessel was found in operation with more than 6 passengers on board. COTP Order 026-24 issued to the owner, ordering the owner to cease operations, whether as an SPV or an uninspected passenger vessel (UPV), until such time as it can be shown to the satisfaction of the roast Guard that your vessel is being operated in compliance with all applicable federal laws and regulations. Vessel must undergo a UPV examination to carry 6 or less passengers or a full credit drydock eamniation and a COI inspection to revalidate the COI for the COTP Order to be rescinded.
Action required: 705 - Other - as specified
Resolved 6 May 2025
Resolution: COI Deactivated. Vessel is laid up and not being used per email communication with the owner. Vessel will have to undergo a credit drydock inspection and COI examination prior to returning to service as a certificated vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 June 2021 Resolved
Vessel required to undergo Hull/DD/ISE examinations as per 46 CFR 176.15-1 no later than May 31, 2021. Vessel has not undergone its required inspections.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2023
Resolution: Vessel is not in service and does not have a COI. Vessel will have to undergo a full COI and drydock inspection if it is ever brought back into certificated passenger service.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 8 March 2021 Resolved
Vessels name required to be marked on port & starboard hull. Vessels name is missing from port & starboard hull (fwd).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2023
Resolution: Vessel is not in service and does not have a COI. Vessel will have to undergo a full COI inspection if it is ever brought back into certificated passenger service.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 March 2021 Resolved
Vessels engaged in voyages of less than 30 minutes are not required to carry visual distress signals. If carried on board, visual distress signals must be of the proper type and not expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 November 2023
Resolution: Vessel is not in service and does not have a COI. Vessel will have to undergo a full COI and drydock inspection if it is ever brought back into certificated passenger service.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 March 2021 Resolved
Vessel required to carry current/up to date navigational publications for areas transited. Existing publications are expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 November 2023
Resolution: Vessel is not in service and does not have a COI. Vessel will have to undergo a full COI and drydock inspection if it is ever brought back into certificated passenger service.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2021 Resolved
Vessel required to carry a suitable first aid kit on board. Existing first aid kit contained expired items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2021
Resolved 1 November 2023
Resolution: Vessel is not in service and does not have a COI. Vessel will have to undergo a full COI and drydock inspection if it is ever brought back into certificated passenger service.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 May 2020 Resolved
Portable fire extinguishers require annual servicing. Vessels portable fire extinguisher(s) servicing date had expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2020
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 May 2020 Resolved
Vessel required to carry current/ up to date navigational publications for areas transited. Vessels USCG Light List, Tidal Tables, Tidal Current Tables were expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2020
Resolved 30 June 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 May 2020 Resolved
Vessel required to carry three fire buckets. Vessel missing 01 fire bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2020
Resolved 30 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 May 2020 Resolved
Vessels PFD stowage locations are required to be marked with size/qty. Vessels port side PFD stowage locations require re-stenciling to reflect accurate qty.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2020
Resolved 30 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 May 2020 Resolved
Vessel required to be fitted with a suitable steering apparatus. Vessels steering pulleys IWO starboard helm and starboard transom are seized/require adjustment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2020
Resolved 30 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 May 2020 Resolved
Vessels fuel fill pipes are required to be "bonded". Vessels port & starboard fuel fills are not properly "bonded" IWO flexible fuel hose connections.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2020
Resolved 8 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2020 Resolved
At all inspections, special attention shall be paid to insure that no fire hazards exist. Vessels bilge's require cleaning to removed oil/oily residue to minimize fire hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2020
Resolved 30 June 2020
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 December 2019 Resolved
A periodic examination is required and shall include the underwater hull and appendages, propellors, shafting, stern bearings, rudders, etc.. and shall be of sufficient scope to determine that these items are in satisfactory condition for the service intended. Attending Inspector(s) noted that the vessels hull was severely pitted/wasted IWO starboard quarter hull/side plating, transom plating, tunnel plating, shaft tube, shaft tube support brackets & rudder post.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2020
Resolution: Attending Inspector(s) verified internal weldments IWO engine compartment, shaft tunnel/log and lazarette.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 December 2019 Resolved
A periodic examination is required and shall include the underwater hull and appendages, propellors, shafting, stern bearings, rudders, etc.. and shall be of sufficient scope to determine that these items are in satisfactory condition for the service intended. Attending Inspector(s) noted that the hull weldment's (where marked) were pitted/wasted and required repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2020
Resolution: Attending Inspector(s) verified repairs (internal) where accessible.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 December 2019 Resolved
Marine Inspector's not limited from making such tests or inspections as are reasonable and practicable to be assured of the seaworthiness of the vessel. Attending Inspector(s) are requiring the vessel to undergo a corrosion survey by a certified ABYC Corrosion Surveyor to determine cause(s) of hull corrosion.
Action required: 705 - Other - as specified
Resolved 1 November 2023
Resolution: Vessel is not in service and does not have a COI. Vessel will have to undergo a full COI and drydock inspection if it is ever brought back into certificated passenger service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 December 2019 Resolved
A periodic examination is required and shall include the underwater hull and appendages, propeller's, shafting, stern bearings, rudders, etc.. and shall be of sufficient scope to determine that these items are in satisfactory condition for the service intended. Attending Inspector(s) noted that the vessels propellor was fractured (trailing edge) and distored (leading edge).
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 6 January 2020
Resolution: Attending Inspector(s) verified servicing of vessel propellor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 5 December 2019 Resolved
All accessible parts of the interior of the vessels hull, watertight bulkheads and weather deck shall be inspected. Attending Inspector(s) noted that the vessels fore/aft watertight bulkhead access covers (bolted flanges) are not equipped with gasketing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 8 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2019 Resolved
Employers are responsible for ensuring compliance with the implementation of a DOT drug testing program. Vessels owner/opeator failed to provide current proof of enrollement with a service agent.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 April 2019
Resolved 24 April 2019
Resolution: Attending Inspector(s) verified proof of enrollment in an approved consortium.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 March 2019 Resolved
Vessel is required to carry current/up to date navigational publications for the areas transited/operated. Vessels navigational publications were expired for route transited/operated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2019 Resolved
Vessel is required to provide a proper size/type of Type I PFD's for each person on board. Vessel is authorized to carry 32 adults. Vessel only had 17 adult Type I PFD's on board.
Action required: 705 - Other - as specified
Resolved 24 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2019 Resolved
Vessels electrical fuses shall be o the cartridge type only and be UL approved. Attending Inspector(s) noted a fuse block installed under the starboard bench seat in main passenger space that accepted blade style fuses.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2019
Resolved 24 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2019 Resolved
Peripheral rail courses at embarkation stations must be removable. Snap hook(s) for port embarkation station rail courses were inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 8 March 2019 Resolved
Vessels bilges shall be kept free of excessive oil to prevent a hazardous condition. Attending Inspector(s) noted excessive oil/water mixture in vessels bilges in way of machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 April 2019
Construction/Loadline › Hull › Hull Plating
Issued 8 December 2017 Resolved
Continue monitoring of vessels exterior hull due to possible stray current corrosion.
Action required: 705 - Other - as specified
Due 8 December 2019
Resolved 5 December 2019
Resolution: Attending Inspector(s) noted additional wastage/pitting and will continue to monitor vessels hull following ABYC Corrosion Survey.
Lifesaving › Hand Flares › Storage
Issued 31 October 2017 Resolved
Provide waterproof storage container for visual distress signals.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified the carriage of a waterprood container for visual distress signals.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 31 October 2017 Resolved
Update/post emergency instructions.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified posting of emergency instructions.
Navigation › Piloting/Steering › Marine Charts
Issued 31 October 2017 Resolved
Provide current/up to date marine charts for areas transisted.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified the carriage of current/up to date marine charts for areas transited.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 31 October 2017 Resolved
Provide current/up to date tidal current tables.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified carriage of current/up to date tidal current tables for areas transited.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 31 October 2017 Resolved
Develop/implement/post Employee Assistance Program (EAP).
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified carriage/implementation of EAP (policy/program).
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 31 October 2017 Resolved
Provide proof of enrollment in an approved consortium.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified enrollment in an approved drug/alcohol testing consortium.
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 October 2017 Resolved
Provide markings (operating instructions) for emergency fuel shut-off valves.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified markings for emergency/remote fuel shut-off valves.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 31 October 2017 Resolved
Renew markings for child sized Type I PFD stowage locations.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified markings for child sized Type I PFD's.
Documentation › Markings/Placards › Warning Signs
Issued 31 October 2017 Resolved
Provide markings for emergency exits (port/starboard)
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified markings for emergency escapes.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 October 2017 Resolved
Repair/replace forward mast head light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified repairs made to fwd mast light and performed operational test.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 October 2017 Resolved
Repair/replace floating water light for ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified replacement of floating water light for ring life buoy.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 31 October 2017 Resolved
Re-route exhaust piping away from main diesel engine air intake.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified repairs/modifications made to main diesel engine exhaust piping.
Engineering › Bilge Water Management System › Piping
Issued 31 October 2017 Resolved
Properly fasten/secure bilge pump piping IWO aft main deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified repairs made to bilge discharge piping.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 31 October 2017 Resolved
Repair/replace emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified repairs/replacement for emergeny lighting.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 31 October 2017 Resolved
Provide proper ground tackle (anchor, chain, line).
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified carriage of proper type/size of ground tackle.
Communications › Audible Communications › Horn/Whistle
Issued 31 October 2017 Resolved
Repair/replace ships horn/whistle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified repairs made to ship's whistle and performed operational test.
Personnel › Training › First Aid/CPR
Issued 31 October 2017 Resolved
Provide current first aid/CPR certification for at least 50% of crew.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified CPR/First Aid training/certification.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 October 2017 Resolved
Removed dead ended wiring IWO console/helm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified removal of dead ended wiring under console/helm.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 October 2017 Resolved
Properly secure electrical wire nuts IWO console/helm.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified proper securing of electrical wire nuts IWO console/helm.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 31 October 2017 Resolved
Remove oil/oily mixtures from machinery space bilges
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified removal of oil/oily mixture from vessels machinery space bilge.
Engineering › Bilge Water Management System › Pump
Issued 31 October 2017 Resolved
Repair/replace fixed hand bilge pump (starboard main deck)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified repairs made to fixed hand bilge pump & performed operational test.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 31 October 2017 Resolved
Provide/install protective grating/cover for main diesel engine exhaust piping or restrict passengers access to aft deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified installation of chains along the port/starboard main deck to keep passengers from the aft portion of the vessel.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 31 October 2017 Resolved
Renew markings for ring life buoy.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified markings for ring life buoy.
Engineering › Steering Gear System › Cable
Issued 31 October 2017 Resolved
Repair/replace steering gear pulley IWO starboard aft main deck (frozen).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Attending Inspector verified repairs made to steering gear pulley (starboard aft main deck).
Construction/Loadline › Hull › Hull Plating
Issued 14 November 2016 Resolved
Remove existing bottom coating & hull zincs due to heavy pitting of vessels hull IWO bottom plating/side shell.
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 3 January 2017
Resolution: Attending Inspector(s) verified the abrasion of existing bottom coat, application of new zincs and final application of anti-foulant bottom coating.
Construction/Loadline › Hull › Hull Plating
Issued 14 November 2016 Resolved
Conduct corrosion survey of vessels hull due to heavy pitting/deterioration of bottom coating.
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 3 January 2017
Resolution: Vesssel owner consulted with a Marine Corrosion Surveyor and was able to verify that the vessels zincs were not proper for the vessels application. Attending Inspector(s) conducted thickness readings of vessels hull via UT.
Construction/Loadline › Hull › Side Shell
Issued 14 November 2016 Resolved
Remove corrosion from port side shell (interior) IWO side shell/main deck and re-coat with marine grade coating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 1 December 2016
Resolution: Attending Inspector verified repairs made to interior corrosion IWO port side shell @ deck.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 November 2016 Resolved
Renew hardware for emergency fuel shut-off valve reach rods (at valve handles).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 1 December 2016
Resolution: Attending Inspector(s) verified installation of new hardware for vessel emergency fuel shut off valves (reach rods).
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 November 2016 Resolved
Repair/replace starboard emergency fuel shut-off valves (valve seized/leaking).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 1 December 2016
Resolution: Attending Inspector(s) verified operation of starboard emergency fuel shut off valve(s).
Construction/Loadline › Structures › Superstructure
Issued 14 November 2016 Resolved
Crop/renew wasted areas of "sill" between main deck & superstructure IWO starboard side.
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 1 December 2016
Resolution: Attending Inspector(s) witnessed repairs made IWO starboard sill.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 November 2016 Resolved
Service all portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2016
Resolved 9 December 2016
Resolution: Attending Inspector(s) verified portable fire extinguisher service.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 November 2016 Resolved
Crop/renew wasted area of fwd watertight bulkhead IWO starboard side door/main deck.
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 1 December 2016
Resolution: Attending Inspector(s) verified repairs made IWO fwd watertight bulkhead, starboard side.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 August 2016 Resolved
Vessels Certificate of Documentation does not reflect new owner/operator.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 5 December 2019
Resolution: Previous outstanding deficiency. Attending Inspector(s) verified corrections made to COD.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 17 June 2014 Resolved
Repair exhuast mainfold leak.
Action required: 705 - Other - as specified
Resolved 29 July 2014
Resolution: The attending MI verified that the exhaust manifold leak was repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 June 2014 Resolved
Repair/replace stbd side stanchion.
Action required: 705 - Other - as specified
Resolved 29 July 2014
Resolution: The attending MI veriified that the stbd side stanchion was repaired.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 17 June 2014 Resolved
Repair/replace cutlass bearing.
Action required: 705 - Other - as specified
Resolved 2 July 2014
Resolution: The attending MI veriified that the cutlass bearing was replaced.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 June 2014 Resolved
Label tripping hazards on fantail near emergency exit.
Action required: 705 - Other - as specified
Resolved 29 July 2014
Resolution: The attending MI verified that the tripping hazard (the steering cables) on the fantail near the emergency exit was properly labeled.
Documentation › Markings/Placards › Warning Signs
Issued 17 June 2014 Resolved
Label emergency exit.
Action required: 705 - Other - as specified
Resolved 29 July 2014
Resolution: The attending MI verified that the emergency exit was properly labeled.
Electrical › Electric Supply System (service) › Cable
Issued 17 July 2012 Resolved
Cable connecting positive to positive on the main battery installation severely corroded and frayed.
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 8 August 2012
Resolution: New electrical wiring was installed on the main battery installation.
Personnel › Training › First Aid/CPR
Issued 17 July 2012 Resolved
Ensure 50% of crew CPR/First Aid certified.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2012
Resolution: CPR and First Aid training conducted for captain and mate.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 17 July 2012 Resolved
Flame screen on goose neck vent pipe damaged.
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 8 August 2012
Resolution: Flame screen replaced.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 July 2012 Resolved
All portable firefighting equipment annual inspection due to be serviced on/before 01AUG12.
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 8 August 2012
Resolution: All portable firefighting inspected.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 July 2009 Resolved
Provide proof of enrollment in random drug testing program for mate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2009
Construction/Loadline › Penetrations › Pipe Flange
Issued 8 July 2009 Resolved
Cut and renew shaft pipe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2009
Resolution: New shaft pipe welded and shaft re-aligned.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 July 2009 Resolved
Lifebouy light expired
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2009
Resolution: Light replaced
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 July 2009 Resolved
Provide proper lifejacket storage markings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2009
Resolution: Location of lifejackets properly marked.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 July 2008 Resolved
Provide valid COD
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2008
Resolution: Master provided valid COD
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 15 July 2008 Resolved
Provide annual inspection for fire extinguishers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 August 2008
Resolved 29 August 2008
Resolution: Master provided proof of servicing on the fire extinguishers.
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 July 2008 Resolved
Service battery on terminals.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2008
Resolution: Master serviced the battery terminals and made repairs.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 July 2008 Resolved
Provide proof of enrollment in drug consortium.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2008
Resolution: Master provided a copy of enrollment in drug consortium.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 July 2008 Resolved
Provide retro reflective tape for ring buoy.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2008
Resolution: Master placed reflective tape to the ring buoy and is in compliance.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 15 July 2008 Resolved
Make necessary repairs to port side fuel shutoff.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2008
Resolution: Master made repairs to the port side fuel shutoff.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 October 2007 Resolved
Provide proper stern light
Due 3 November 2007
Resolved 22 October 2007
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 3 October 2007 Resolved
Replace throttle handle at the operating station.
Due 3 November 2007
Resolved 22 October 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 October 2007 Resolved
Annual inspection was not conducted within 90 days past the anniversary date on the COI
Due 3 October 2007
Resolved 3 October 2007
Resolution: Annual inspection conducted
Personnel › Training › First Aid/CPR
Issued 22 June 2006 Resolved
Owner to provide updated CPR/1st aid training to vsl crew. Vsl crew was hesitant and unsure of what to due when queried on administering CPR/1st aide to victim.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 June 2006 Resolved
Vessel to remove excessive oil from bilges.
Condition: Improper/Lack of Maintenance
Due 20 July 2006
Resolved 3 October 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 18 July 2005 Resolved
Flashlights need new batteries.
Condition: Improper/Lack of Maintenance
Due 3 August 2005
Resolved 3 August 2005
Resolution: Provided new batteries.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 July 2005 Resolved
Light not secured to ring buoy with releasable clip.
Condition: Improper Installation
Due 3 August 2005
Resolved 3 August 2005
Resolution: Provided release clip for buoy light.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 July 2005 Resolved
Labeling for storage of PFD's innacurate.
Condition: Improper Installation
Due 3 August 2005
Resolved 3 August 2005
Resolution: Correctly labeled PFD storage.
Fire Fighting › Fire Bucket › Stenciling
Issued 18 July 2005 Resolved
2 of 3 Fire buckets not labeled.
Condition: Improper Installation
Due 3 August 2005
Resolved 3 August 2005
Resolution: Labeled all 3 buckets correctly
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 July 2005 Resolved
Port side nav light bulb needs to be replaced.
Condition: Improper/Lack of Maintenance
Due 3 August 2005
Resolved 3 August 2005
Resolution: Replaced nav light.
Fire Fighting › Fire Pumps › Vacuum Pump
Issued 18 July 2005 Resolved
Hose comes undone under weight of water. Recommended using a clamp to hold together.
Condition: Design Flaw
Due 3 August 2005
Resolved 2 August 2005
Resolution: Provided hose clamp for bilge pump hose.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 29 September 2004 Resolved
Post emergency instructions
Due 14 October 2004
Resolved 14 October 2004
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 29 September 2004 Resolved
Mark number of adult and child PFDs at stowage location
Due 14 October 2004
Resolved 14 October 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 September 2004 Resolved
Add reflective tape to lifebuoy
Due 14 October 2004
Resolved 14 October 2004
Fire Fighting › Fire Bucket › Quantity
Issued 29 September 2004 Resolved
Two additional fire buckets needed
Due 14 October 2004
Resolved 14 October 2004
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 29 September 2004 Resolved
Add flashlight at operating station and engine hatch
Due 14 October 2004
Resolved 14 October 2004
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 29 September 2004 Resolved
Mark emergency exit
Due 14 October 2004
Resolved 14 October 2004
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 29 September 2004 Resolved
Mark main deck bilge pump
Due 14 October 2004
Resolved 14 October 2004
Operations/Management › Drills/Instruction › Fire
Issued 29 September 2004 Resolved
Mark main deck f/o shut offs
Due 14 October 2004
Resolved 14 October 2004
Operations/Management › Passenger Operations › Safety Orientation
Issued 29 September 2004 Resolved
Post PFD placard
Due 14 October 2004
Resolved 14 October 2004
Personnel › Training › Familiarization Training
Issued 29 September 2004 Resolved
Conduct safety drills with deckhand
Due 14 October 2004
Resolved 14 October 2004
Stability › Intact Stability (when using lifting gear) › General
Issued 29 September 2004 Resolved
Conduct stability test
Due 29 December 2004
Resolved 1 November 2004
Resolution: Simplified stability test conducted - all sat.
Construction/Loadline › Hull › Hull Plating
Issued 23 July 2004 Resolved
Gauge hull. (Hull gauged 7/28; side shell and bottom plating are outside allowable 25% wastage. This worklist item updated to repair as original bottom and sideshell plating.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2004
Resolved 17 September 2004
Resolution: Sat. gauging conducted.
Engineering › Steering Gear System › Rudder Bearing
Issued 23 July 2004 Resolved
Replace wasted bearing IWO rudder post.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2004
Resolved 22 September 2004
Resolution: Bearing replaced satifactory.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 23 July 2004 Resolved
Refurbish chipped propellar blade.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2004
Resolved 22 September 2004
Resolution: Blades satisfactory refurbished.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 23 July 2004 Resolved
C/R wasted struts.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2004
Resolved 22 September 2004
Resolution: Struts replaced satisfactory.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 23 July 2004 Resolved
Replace fuel and bilge pump wiring with marine grade 14 gauge wiring. Wiring to be installed inside a heat resistant conduit or arranged in a manner that prevents contact with the m/e.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2004
Resolved 17 September 2004
Resolution: Wires satisfactory installed.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 23 July 2004 Resolved
Remove oil from bilges.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2004
Resolved 17 September 2004
Resolution: Oil removed from bilge.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 23 July 2004 Resolved
Replace bulging flex hose connection IWO M/E keel cooler.
Condition: Improper Installation
Due 17 September 2004
Resolved 22 September 2004
Resolution: Hose replaced satifactory.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 23 July 2004 Resolved
Repack or adjust excessively leaking shaft packing.
Condition: Improper/Lack of Maintenance
Due 17 September 2004
Resolved 22 September 2004
Resolution: Shaft Packing was adjusted satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 July 2004 Resolved
Re-wrap exposed M/E exhaust piping.
Condition: Improper/Lack of Maintenance
Due 17 September 2004
Resolved 22 September 2004
Resolution: Lagging re-wraped satisfactory.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 23 July 2004 Resolved
Re-wire improperly installed bilge pump.
Condition: Improper Installation
Due 17 September 2004
Resolved 22 September 2004
Resolution: Bilge pump installed properly.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 July 2004 Resolved
Service expired F/E.
Condition: Improper/Lack of Maintenance
Due 17 September 2004
Resolved 22 September 2004
Resolution: F/E serviced satisfactory.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 23 July 2004 Resolved
Properly improperly installed electrical panel.
Condition: Improper Installation
Due 17 September 2004
Resolved 22 September 2004
Resolution: Electrical panel properly installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 15 July 2003 Resolved
provide proof of annual servicing of portable fire extinguishers LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2003
Resolved 29 July 2003
Resolution: corrected sat
Fire Fighting › Miscellaneous Items
Issued 15 July 2003 Resolved
provide one labeled fire bucket with lanyard
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 July 2003
Resolved 29 July 2003
Resolution: corrected sat
Operations/Management › Pollution
Issued 15 July 2003 Resolved
clean oil residue from engine room bilge LEGACY COMPONENT DESC: Retention of Oily Mixture
Action required: 705 - Other - as specified
Due 29 July 2003
Resolved 29 July 2003
Resolution: corrected sat
Documentation › Certificates/Documents
Issued 15 July 2003 Resolved
Properly post COI on wheelhouse bulkhead LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 July 2003
Resolved 29 July 2003
Resolution: corrected sat
Documentation › Manuals/Policy Documentation
Issued 15 July 2003 Resolved
provide proper training log LEGACY COMPONENT DESC: Training Manual (lifesaving)
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 July 2003
Resolved 29 July 2003
Resolution: corrected sat
Lifesaving › Lifejacket/PFD (Type I)
Issued 15 July 2003 Resolved
provide proper labeling for adult & child sized lifejackets, fuel shut-off's, and emergency exit LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 29 July 2003
Resolved 29 July 2003
Resolution: corrected sat
Engineering › Shafting/Propeller Arrangements
Issued 15 July 2003 Resolved
properly secure shaft packing LEGACY COMPONENT DESC: Stern Tube
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2003
Resolved 29 July 2003
Resolution: corrected sat
Operations/Management › Drug and Alcohol Testing
Issued 20 August 2002 Resolved
Provide proof of enrollement in drug and alcohol program. LEGACY COMPONENT DESC: Proof of Enrollment
Due 6 September 2002
Resolved 5 September 2002
Personnel › Training
Issued 20 August 2002 Resolved
Prove 50% of crew has had proper training LEGACY COMPONENT DESC: First Aid/CPR
Due 6 September 2002
Resolved 5 September 2002
Construction/Loadline › Hull
Issued 14 June 2002 Resolved
Make proper repairs to propeller wasted shaft housing
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2002
Resolved 25 June 2002
Resolution: Welded and recoated parts of shaft housing that were pitted. Replaced worn cutlass bearing.
Construction/Loadline › Hull
Issued 14 June 2002 Resolved
Make proper repairs to 2 pits as marked IWO STBD side keel aft LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2002
Resolved 25 June 2002
Resolution: Spot welded and re-coated marked locations.
Engineering
Issued 22 August 2000 Resolved
Repair engine box cover so all sides properly secured.
Condition: Unknown
Due 29 August 2000
Resolved 7 September 2000
Unknown
Issued 7 August 2000 Resolved
DESIGNATE DECKHAND IN WRITING AND TRAIN FOR ALL APPLICABLE DUTIES.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Engineering
Issued 7 August 2000 Resolved
REPAIR OIL LEAK AT ENG VALVE COVER
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Documentation
Issued 7 August 2000 Resolved
START AND MAINTAIN LOGBOOK FOR REQUIRED DRILLS (QUARTERLY) FIRE, MAN OVER BOARD.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Lifesaving
Issued 7 August 2000 Resolved
REPAIR HORN.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Construction/Loadline
Issued 7 August 2000 Resolved
INSTALL HIGH LEVEL BILGE ALARM WARNING LIGHT AT OPERATOR STATION.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Electrical
Issued 7 August 2000 Resolved
REPLACE BATTERY GROUND CABLE.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Lifesaving
Issued 7 August 2000 Resolved
REPLACE BATTERY BOX COVER.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Lifesaving
Issued 16 August 1999 Resolved
Provide donning instructions for lifejackets.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Navigation
Issued 16 August 1999 Resolved
Provide radio for vessel.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Documentation
Issued 16 August 1999 Resolved
Provide first aid/CPR card for Master.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Navigation
Issued 16 August 1999 Resolved
Make permanent repairs to all around white light.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Construction/Loadline
Issued 16 August 1999 Resolved
Install high level bilge alarms.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Fire Fighting
Issued 16 August 1999 Resolved
Provide servicing report for fire extinguishers.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Engineering
Issued 16 August 1999 Resolved
Mark emergency fuel shutoffs.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Lifesaving
Issued 23 July 1998 Resolved
Add clip to waterlight and provide floating UV resistant line to ring bouy.
Condition: Unknown
Due 23 August 1998
Resolved 30 November 1998
Fire Fighting
Issued 23 July 1998 Resolved
Provide proof of service for all fire extinguishers.
Condition: Unknown
Due 23 August 1998
Resolved 30 November 1998
Electrical
Issued 23 July 1998 Resolved
Provide proper ground for starter relay wire.
Condition: Unknown
Due 23 August 1998
Resolved 30 November 1998
Electrical
Issued 9 September 1997 Resolved
REPAIR AFT MOST CABIN LIGHT.
Condition: Unknown
Due 9 September 1997
Resolved 9 September 1997
Navigation
Issued 9 September 1997 Resolved
REPAIR INOPERATIVE ELECTRIC SHIP'S WHISTLE. (VOICE OPERATED HORN ABOARD).
Condition: Unknown
Due 9 September 1997
Resolved 9 September 1997
Engineering
Issued 9 September 1997 Resolved
PROVIDE SUPPORT FOR COOLANT HOSE TO PREVENT ITS CRIMPING.
Condition: Unknown
Due 9 September 1997
Resolved 9 September 1997
Electrical
Issued 9 September 1997 Resolved
PROVIDE ONE ADDITIONAL FLASHLIGHT.
Condition: Unknown
Due 9 September 1997
Resolved 9 September 1997
Engineering
Issued 19 June 1997 Resolved
Make repairs to oil leak in reduction gear.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Engineering
Issued 19 June 1997 Resolved
Renew propeller shaft cutlass bearing.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Navigation
Issued 19 June 1997 Resolved
Renew rudder post cutlass bearing.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Engineering
Issued 19 June 1997 Resolved
Renew short cooling water hoses.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Documentation
Issued 7 August 1996 Resolved
PUT UPDATE STAMP ON BACK OF CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 7 August 1996
Resolved 7 August 1996
Navigation
Issued 7 August 1996 Resolved
REPLACE BURNED OUT LIGHT BULB IN THE ANCHOR LIGHT. DO NOT OPERATE VESSEL DURING HOURS OF DARKNESS OR LOW VISIBILITY UNTIL CORRECTED.
Condition: Unknown
Due 7 August 1996
Resolved 7 August 1996
Navigation
Issued 10 August 1995 Resolved
RENEW STARBOARD STEERING CABLE.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Unknown
Issued 10 August 1995 Resolved
POST NAME AND HOMEPORT ON STERN.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Engineering
Issued 10 August 1995 Resolved
CLEAN OIL FROM ENGINE COMPARTMENT BILGE.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Engineering
Issued 17 August 1994 Resolved
REPLACE THREE FUEL HOSES WITH USCG/SAE APPROVED MARINE TYPE HOSES AND FITTINGS.
Condition: Unknown
Due 17 August 1994
Resolved 17 August 1994
Lifesaving
Issued 17 August 1992 Resolved
APPLY RETROREFLECTIVE MATERIAL TO LIFE RING.
Condition: Unknown
Due 22 December 1992
Resolved 22 December 1992
Fire Fighting
Issued 17 August 1992 Resolved
SERVICE OR REPLACE 1 B-I AND 1 B-II FIRE EXTINGUISHER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 December 1992
Resolved 22 December 1992
Construction/Loadline
Issued 17 August 1992 Resolved
SUPPLY DISCHARGE HOSE FOR HAND PUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 December 1992
Resolved 22 December 1992
Documentation
Issued 17 August 1992 Resolved
PROVIDE LETTER OF DESIGNATION TO 1 OR MORE DECKHANDS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 December 1992
Resolved 22 December 1992
Deck/Cargo
Issued 6 September 1991 Resolved
REPAIR OR REPLACE ANCHOR AND ANCHOR LINE.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Lifesaving
Issued 6 September 1991 Resolved
INSTALL RELECTIVE TAPE ON RING BOUY.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Construction/Loadline
Issued 6 September 1991 Resolved
REMOVE EXCESSIVE OIL FROM BILGES.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Documentation
Issued 6 September 1991 Resolved
RENEW VESSEL'S DOCUMENT.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Accommodation/Occupational Safety
Issued 6 September 1991 Resolved
REPLACE MISSING WINDOW OPENING/CLOSURE CRANKS FOR WINDOWS ON ACCOMODATION CABIN AND BRIDGE.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Engineering
Issued 6 September 1991 Resolved
SECURE LOOSE WATER TEMPERATURE GAUGE ON BRIDGE CONSOLE.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Fire Fighting
Issued 2 October 1990 Resolved
PROVIDE AND INSTALL APPROVED BRACKET FOR B-II FIRE EXTINGUISHER IN PASSENGER COMPARTMENT.
Condition: Unknown
Due 2 October 1990
Resolved 2 October 1990
Engineering
Issued 2 October 1990 Resolved
INSTALL DOUBLE CLAMPS ON ENGINE COOLING HOSES.
Condition: Unknown
Due 2 October 1990
Resolved 2 October 1990
Engineering
Issued 2 October 1990 Resolved
PROVIDE AND INSTALL ADDITIONAL BOLT ON PORT FUEL SHUT-OFF REACH ROD CONNECTION.
Condition: Unknown
Due 2 October 1990
Resolved 2 October 1990
Navigation
Issued 5 September 1989 Resolved
MAKE OPERABLE ALL-AROUND WHITE LIGHT.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Lifesaving
Issued 5 September 1989 Resolved
USE INSECTICIDE IN LIFEJACKET BOX TO PROTECT JACKETS.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Electrical
Issued 5 September 1989 Resolved
INSTALL COVERS ON BATTERIES.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Engineering
Issued 5 September 1989 Resolved
SHOW BILGE PUMP OPERABLE AND PROPERLY ATTACH TO BULKHEAD.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Navigation
Issued 5 September 1989 Resolved
MAKE RED, PORT NAVIGATION LIGHT.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Engineering
Issued 5 September 1989 Resolved
REPLACE PORT FUEL VENT FLAME SCREEN.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989

Ownership record