MAURY USCG vessel records
← All vessels

PERA

PERA is a 1995 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in August 2021, along with 8 deficiencies.

Records from 2016 to 2021. Most recent: inspection, 27 August 2021.

Built
1995
Last inspected
27 August 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 August 2021
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9111149
460100
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-460100

Documentation record

Tonnage as PSIX records it2514 - Convention (Subpart B), Gross Ton
1351 - Convention (Subpart B), Net Ton
4936 - Displacement, Ton
3610 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

12 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

27 August 2021 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7297990
3 March 2021 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7148600
3 March 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7149354
23 February 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7144713
1 September 2020 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7043340
31 August 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7046458
25 August 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7042646
8 March 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam · Deficiency Check · COE-Dockside
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6637033
2 August 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6228433
17 January 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6071772
4 June 2016 PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5891619
20 May 2016 Ballast Water Examination · Administrative Inspection · PI Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5877581

Deficiency record · 8

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 March 2019 Resolved
After any survey of the ship under Article 14 has been completed, no change shall be made in the structure, equipment, arrangements, material or scantlings covered by the survey, without the sanction of the Administration. There is an inset on the aft port quarter, between frames 7, 8 and 9, the latter of which appears to be compromised externally. Internally the damage cannot be assessed without destroying the false, decorative bulkhead. ICLL 66/88, Article 15.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2019
Resolution: Class had the decorative bulkhead removed and assessed the frames internally. No further action considered necessary.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 March 2019 Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of these Rules. Vessel did not have up to date navigation rules. 33 CFR 83.01(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 March 2019
Resolution: New publications were purchased.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 3 August 2017 Resolved
The fire resistance doors shall be equivalent to to that of the division in which they are fitted. Doors fitted in boundary bulkheads of machinery spaces of category A shall be resaonably tight and self-closing. Door in machinery space for means of escape does not meet requirements to be self-closing. 74 SOLAS (97 Cons.) II-2/47.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 March 2019
Resolution: FIRE DOORS WERE RE-EXSAMINED DURING INSPECTION AND FOUND TO BE WORKING SATIFACTORILLY
Navigation › Piloting/Steering › Magnetic Compass
Issued 3 August 2017 Resolved
All ships shall have a properly adjusted standard magnetic compass to determine the ships heading and display the reading at the main steering position. Ships compass was allowed one degree of deviation but deviated by nine degrees. 74 SOLAS (14CONS.) V/19.2.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 March 2019
Resolution: COMPASS WAS FOUND TO BE IN WORKING CONDITION IAW THE ALLOWED DEVIATION.
Communications › Visual Communication › Signalling Lamp
Issued 3 August 2017 Resolved
All ships over 150 gross tons shall have on board an efficient daylight signaling lamp which shall not be solely dependent upon the ships main source of electrical power. Ships signaling lamp does not have power provided by portable battery. 74 SOLAS (01 Cons) V/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 March 2019
Fire Fighting › Fire Hydrants › Condition
Issued 20 May 2016 Resolved
PSCO noted that the water available for the fire hydrants was weak using both main and emergency fire pumps. Vessel experienced flooding in a ballast tank after condcting a washdown, which the crew believed indicated a rupture in the fire main , further evidenced by low water pressure available at the hydrants. 74 SOLAS(97) II-2/21. 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2016
Resolved 27 May 2016
Resolution: Class Document Submitted verifying rectification of deficiency. See documents
Engineering › Gasoline Engine (propulsion) › Oil Sump (4 cycle)
Issued 20 May 2016 Resolved
PSCO observed that main service generator #2 was inoperable and disassembled due to internal damage caused by an inoperable lube oil pump. 74SOLAS(04) II-1/41.1.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2016
Resolved 27 May 2016
Resolution: Class Document Submitted verifying rectification of deficiency. see documents
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 20 May 2016 Resolved
PSCO noted that one of the two firema's outfits was worn down and the protective outer layer was faded. S74 SOLAS(97)II-2/ 17.1.1.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2016
Resolved 27 May 2016
Resolution: Class Document Submitted verifying rectification of deficiency. see documents

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.