MAURY USCG vessel records
← All vessels

MCR 9

Built
1968
Last inspected
27 April 2005
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 27 April 2005
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 20 calendar years (1985–2005)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
2189 - Regulatory (Subpart C or D), Gross Ton 2195 - Convention (Subpart B), Gross Ton 2189 - Regulatory (Subpart C or D), Net Ton 816 - Convention (Subpart B), Net Ton
Maury page id
psix-46014
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 47

27 April 2005 MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2344082
27 May 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1802600
1 April 2003 Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1766326
26 April 2002 Re-Inspection · Cargo Tank Internal
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1608415
25 January 2002 MARPOL Annex I Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1481496
11 June 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1469360
7 September 2000 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 822485
21 June 2000 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1429375
15 May 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1361477
13 July 1999 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1441536
13 May 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1444150
20 February 1999 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1413482
10 September 1998 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 799097
21 May 1998 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1430569
11 May 1998 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1413291
6 May 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 791373
18 September 1997 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1378163
23 January 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 777502
23 January 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1435866
29 January 1996 MARPOL Annex II Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 884455
16 January 1996 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1465229
9 February 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 841695
9 January 1995 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1466919
25 February 1994 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1163840
6 January 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1132608
22 September 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 533926
7 July 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 947250
18 May 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1270356
22 January 1992 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1269056
28 June 1991 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 919750
12 December 1990 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 903602
19 March 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 926956
15 February 1990 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 918546
8 June 1989 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 887716
19 May 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1196251
16 December 1988 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 898444
9 December 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 898905
24 April 1988 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1341325
12 February 1988 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1326758
8 December 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1000447
3 December 1987 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1335026
24 November 1987 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1334688
8 October 1987 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1024977
6 February 1987 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1003409
22 December 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1001837
12 December 1986 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1022334
17 September 1985 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1293498

Deficiency record · 19

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 27 May 2003 Resolved
Prior to carriage of liquid cargo prove the operation of the associated systems.
Action required: 705 - Other - as specified
Due 15 May 2005
Resolved 7 June 2007
Resolution: Old Requirement Vessel not allowed to carry Liquid Cargo untill system tested
Construction/Loadline › Hull
Issued 1 April 2003 Resolved
#2P and #5P/S void spaces have excessive wastage of the longitudinals. LEGACY COMPONENT DESC: Longitudinal Frame
Action required: 705 - Other - as specified
Resolved 23 May 2003
Resolution: ABS Rep. witnessed the satisfactory completion of the repairs to the barge.
Construction/Loadline › Penetrations
Issued 1 April 2003 Resolved
Sea chests and valves were not ready for inspection during initial inspection.
Action required: 705 - Other - as specified
Resolved 2 April 2003
Resolution: J. Winters visited vsl to examine sea chests and valves. All appeared sat.
Electrical
Issued 9 January 1995 Resolved
RENEW WASTED 110 VAC ELECTRICAL BOX ON STBD MAIN DECK BETWEEN STBD 2 AND STBD 3 VOIDS.
Condition: Unknown
Due 9 February 1995
Resolved 13 February 1995
Electrical
Issued 9 January 1995 Resolved
PROVE PROPER OPERATION OF THE #1 AND #2 DSL GENERATOR OR REMOVE FROM VESSEL.
Condition: Unknown
Due 9 February 1995
Resolved 13 February 1995
Documentation
Issued 9 January 1995 Resolved
UPDATE NLS DOCUMENT PRIOR TO CARRIAGE OF CAUSTIC SODA.
Condition: Unknown
Due 9 February 1995
Resolved 13 February 1995
Construction/Loadline
Issued 9 January 1995 Resolved
RENEW AFT VOID W/T HATCH GASKET.
Condition: Unknown
Due 9 February 1995
Resolved 13 February 1995
Electrical
Issued 9 January 1995 Resolved
PROVIDE A MEANS TO KEEP INSULATED ELECTRICAL MATT IN FRONT OF SWITCH BOARD DRY.
Condition: Unknown
Due 13 February 1995
Resolved 13 February 1995
Construction/Loadline
Issued 12 December 1990 Resolved
PREPARE THE FOLLOWING TANKS FOR INTERNAL EXAMS NLT 30JUN91; CARGO TANKS #1,5P AND 5S WING TANKS, AND #6.
Condition: Unknown
Due 12 December 1990
Resolved 12 December 1990
Construction/Loadline
Issued 12 December 1990 Resolved
HAVE THE DOUBLE BOTTOMS OF THE FOLLOWING TANKS READY FOR INSPECTION NLT 30JUN91; CENTER CARGO TANKS 2P, 2S, 3P, 3S, 4P, 4S, 5P AND 5S.
Condition: Unknown
Due 12 December 1990
Resolved 12 December 1990
Deck/Cargo
Issued 9 December 1988 Resolved
INSTALL AND MAKE FUNCTIONAL EMERGENCY SHUTDOWN, ON DECK, FOR # 2 ELECTRICALAUX. CARGO PUMP PRIOR TO USEAGE OR 23DEC88 TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 9 December 1988
Resolved 9 December 1988
Unknown
Issued 9 December 1988 Resolved
CLEAN MACHINERY / PUMP ROOM BILGES, DECKS AND MACHINERY PRIOR TO 16DEC88 TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 9 December 1988
Resolved 9 December 1988
Electrical
Issued 9 December 1988 Resolved
MAKE FUNCTIONAL AIR FLAPPER VALVE ON 8V71 DETROIT DEISEL GENERATOR PRIOR TONEXT CARGO OPERATION OR 16DEC88 TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 9 December 1988
Resolved 9 December 1988
Construction/Loadline
Issued 9 December 1988 Resolved
FRESHEN ALL HULL MARKINGS PRIOR TO 23 DEC88 TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 9 December 1988
Resolved 9 December 1988
Deck/Cargo
Issued 9 December 1988 Resolved
LABEL ALL CARGO VALVES AS PER C.G. APPROVED DIAGRAMS AND COMMENT LETTERS PRIOR TO 23DEC88 TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR
Condition: Unknown
Due 9 December 1988
Resolved 9 December 1988
Electrical
Issued 8 October 1987 Resolved
MAKE PERMANENT REPAIRS TO WIRING JUNCTION BOX AND CONTACTOR COIL FOR CHROMOLOX HEATER ON FORWARD MACHINERY SPACE BULKHEAD OR REMOVE INSTALLATION
Condition: Unknown
Due 8 October 1987
Resolved 8 October 1987
Electrical
Issued 8 October 1987 Resolved
REMOVE GROUND IN "B" PHASE 440 VOLT SYS ON MAIN PANEL.
Condition: Unknown
Due 8 October 1987
Resolved 8 October 1987
Construction/Loadline
Issued 8 October 1987 Resolved
PROVIDE COPY OF APPROVAL LETTER AUTHORIZING PLYWOOD BULKHEAD IN FORWARD STORAGE AREA AND ASSOCIATED WIRING.
Condition: Unknown
Due 8 October 1987
Resolved 8 October 1987
Electrical
Issued 12 December 1986 Resolved
DEMONSTRATE PROPER OPERATION OF REMOTE EMERGENCY SHUTDOWN TO GENERATOR DRIVEN CARGO PUMP AND DEMONSTRATE OPERATION OF OVERSPEED TRIP ON THE GENERATOR.
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.