Records from 1984 to 1989. Most recent: inspection, 19 November 1989.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 36
19 November 1989
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1203016
22 June 1989
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1352610
11 October 1988
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1196297
6 May 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039194
17 March 1988
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1336749
8 February 1988
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1019235
29 January 1988
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1016639
28 January 1988
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1322960
18 September 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1010057
16 July 1987
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 528232
10 July 1987
Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1311988
10 July 1987
Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1315978
3 July 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1010429
25 June 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1315399
20 April 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010595
9 April 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1317534
20 March 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1022707
20 March 1987
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1338292
16 March 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1323631
13 March 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1014900
17 December 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 475696
25 July 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 310387
10 April 1986
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 998758
26 March 1986
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 996142
13 March 1986
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 992010
6 February 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304681
7 August 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 983268
27 July 1985
Re-Inspection · Credit Drydock
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 981809
3 May 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289682
12 April 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 536457
29 March 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1287661
28 March 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1286593
23 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1290500
22 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1290320
8 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1286345
13 November 1984
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 483620
Construction/Loadline
Issued 28 January 1988
Resolved
CROP AND RENEW TO GOOD METAL THE SECTION OF SIDE SHELL CHANNEL FRAME THAT IS WASTED . IT IS LOCATED AT THE TURN OF THE BILGE JUST OUTBOARD OF THE ENGINE ROOM FIRE PUMP.
Condition: Unknown
Due 31 July 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 28 January 1988
Resolved
MAKE PERMANENT REPAIRS TO THE 2-1/2 INCH EVAPORATOR BRINE SUCTION SPOOL PIECE.
Condition: Unknown
Due 31 July 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 18 September 1987
Resolved
AIR RECEIVERS, EVAPORATORS , DC HEATER AND BOILER STEAM PIPING WERE NOT TESTED OR INTERNALLY EXAMINDED. REQUIRED TO BE COMPLETED AT NEXT DDX OR 07JAN88 WHICH EVER COMES FIRST.
Condition: Unknown
Due 18 September 1987
Resolved 18 September 1987
Engineering
Issued 10 July 1987
Resolved
REQUIRED TEST OF BOILER AND SUPERHEATER SAFETY VALVES NOT TESTED AT COI.
Condition: Unknown
Due 10 July 1987
Resolved 10 July 1987
Engineering
Issued 10 July 1987
Resolved
SAFETY VALVES NOT INSPECTED AND TESTED LAST COI.
Condition: Unknown
Due 10 July 1987
Resolved 10 July 1987
Fire Fighting
Issued 20 March 1987
Resolved
A. MAKE OPERABLE STEAM DRIVEN AUX. FIRE/BILGE PUMP B. MAKE OPERABLE AUX. WASHWATER DC DRIVEN PUMP
Condition: Unknown
Due 20 March 1987
Resolved 20 March 1987
Unknown
Issued 20 March 1987
Resolved
REPAIR CRACK IN GUIDE FOR CONTAMINATED EVAPORATOR STEAM DRIVEN PUMP
Condition: Unknown
Due 20 March 1987
Resolved 20 March 1987
Lifesaving
Issued 20 March 1987
Resolved
CENTRALLY LOCATED ALL PYROTECHNICS AND LINE THROWING GUN
Condition: Unknown
Due 20 March 1987
Resolved 20 March 1987
Navigation
Issued 20 March 1987
Resolved
REPAIR LEAK IN STEERING GEAR PUMP
Condition: Unknown
Due 20 March 1987
Resolved 20 March 1987
Fire Fighting
Issued 20 March 1987
Resolved
TEST CO2 ALARMS
Condition: Unknown
Due 20 March 1987
Resolved 20 March 1987
Navigation
Issued 20 March 1987
Resolved
MISSING STEERING GEAR INSTRUCTIONS ON THE BRIDGE
Condition: Unknown
Due 20 March 1987
Resolved 20 March 1987
Unknown
Issued 20 March 1987
Resolved
REPAIR STEAM LEAKS AT STBD BOILER SUPERHEATER RELIEF VALVE AND AIR INJECTORSTEAM MANIFOLD BETWEEN THE BOILER STEAM DRIVEN ON FWD BULKHEAD
Condition: Unknown
Due 20 March 1987
Resolved 20 March 1987
Electrical
Issued 20 March 1987
Resolved
PERFORM OVERSPEED AND LOW LUBE OIL TRIP ON AC GENERATOR AND MAIN EMERGENCY GENERATOR
Condition: Unknown
Due 20 March 1987
Resolved 20 March 1987
Fire Fighting
Issued 20 March 1987
Resolved
FLUSH OUT CO2 SYSTEM AND FIRE MAINS IN ENGINE SPACES (TO BE COMPLETED AT NEXT DRYDOCK).
Condition: Unknown
Due 27 January 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 16 March 1987
Resolved
RENEW DAMAGED FUEL TANK VENT LOCATED ON PORT SIDE AFT.
Condition: Unknown
Due 16 March 1987
Resolved 16 March 1987
Unknown
Issued 16 March 1987
Resolved
RENEW APPROXIMATELY 40-50 FEET OF DAMAGED RAILING ON PORT AND STARBOARD SIDES AFT.
Condition: Unknown
Due 16 March 1987
Resolved 16 March 1987
Unknown
Issued 16 March 1987
Resolved
COMPLETE DAMAGE SURVEY TO MAIN DECK AFT UPON REMOVAL OF DAMAGED CONTAINERS.
Condition: Unknown
Due 16 March 1987
Resolved 16 March 1987
Unknown
Issued 16 March 1987
Resolved
RENEW PORT AND STARBOARD BOARDING LADDERS.
Condition: Unknown
Due 16 March 1987
Resolved 16 March 1987
Construction/Loadline
Issued 16 March 1987
Resolved
EFFECT PROPER REPAIRS TO TEAR IN SHEER STRAKE EXTENSION LOCATED IN WAY OF CHOCK ON PORT SIDE AFT.
Condition: Unknown
Due 16 March 1987
Resolved 16 March 1987
Lifesaving
Issued 13 March 1986
Resolved
REPAIR AFT LIMIT SWITCH ON STBD SIDE LIFEBOAT FALLS.
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986
Construction/Loadline
Issued 13 March 1986
Resolved
REPLACE DOGGING BOLTS ON VENT CLOSURE AT PORT SIDE ACCOMIDATION LADDER
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986
Construction/Loadline
Issued 13 March 1986
Resolved
REPLACE DOG ON WATER TIGHT DOOR AT STERN OF MAIN HOUSE
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986
Construction/Loadline
Issued 13 March 1986
Resolved
REPLACE STRIKER PLATES FOR CENTER WTD ON STBD SIDE OF AFT HOUSE
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986
Construction/Loadline
Issued 13 March 1986
Resolved
REPLACE STRIKER PLATE FOR FWD WTD ON STBD SIDE OF AFT HOUSE
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986
Accommodation/Occupational Safety
Issued 13 March 1986
Resolved
FREE-UP DAMPERS ON ALL COWLED VENTS ON FANTAIL
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986
Construction/Loadline
Issued 13 March 1986
Resolved
REPAIR OR REPLACE PORT DOGGING BOLT FOR CENTER HATCH COVER ON #11 HOLD AFT
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986
Deck/Cargo
Issued 13 March 1986
Resolved
REPAIR VENT #9 HOLD STBD SIDE AFT WHERE WASTED
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986
Electrical
Issued 23 March 1985
Resolved
E-1 PROVE PROPER OPERATION OF #1SSTG UNDER FULL LOAD AS PER ORIGINAL INSTALLATION.
Condition: Unknown
Due 23 March 1985
Resolved 23 March 1985
Engineering
Issued 22 March 1985
Resolved
CONDUCT FIRESIDE AND WATERSIDE EXAMINATION OF THE PORT BOILER. MAKE PERMANENT REPAIRS TO REFRACTORY AND MINOR TUBE LEAKS. HYDROSTATICALLY TEST BOILER REPAIRS. THIS ITEM TO BE COMPLETED PRIOR TO 22 MARCH 1985.
Condition: Unknown
Due 22 March 1985
Resolved 22 March 1985