Inspection history · 45
1 April 2026
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8340781
10 April 2025
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8109990
12 March 2024
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7878337
8 March 2023
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7648179
25 May 2022
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7459664
16 February 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7398003
21 April 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7179215
26 February 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6921963
3 April 2019
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6658436
8 May 2018
Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6409452
11 April 2018
COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6393267
24 February 2018
Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6366021
24 April 2017
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6133230
14 April 2016
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5854962
15 January 2015
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5059120
8 April 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 4834143
14 June 2012
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4347890
15 November 2011
Hull Examination · COI Inspection · DAPI Audit
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4193800
26 September 2011
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4154341
29 December 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 808744
9 May 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1102088
11 March 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1404319
13 March 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1447550
5 April 1995
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1160432
21 April 1994
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 856950
6 April 1994
Hull Examination · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1166967
5 May 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 840965
6 April 1993
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1154649
18 March 1993
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 837398
2 March 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 839522
26 January 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 831360
9 June 1992
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1270501
1 May 1992
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 962025
26 March 1992
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 950364
16 April 1991
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 999241
31 May 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1238385
25 April 1990
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 922037
5 June 1989
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1040488
8 May 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1206064
28 March 1989
COI Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1213616
28 March 1989
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1219321
9 May 1988
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1043367
30 March 1987
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1018989
1 April 1986
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1305499
29 April 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1286976
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2022
Resolved
Vessel Owner was unable to show operation of the bilge pumping system during the inspection. Bilge pumping system was unable to pull water from the bilge during multiple tests. Vessel Owner is required to show full operation of the bilge system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2022
Resolution: Vessel owner was able to show operation of the bilge pumping system.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 25 May 2022
Resolved
Fire extinguishers on board the vessel have an inspection date of May 2021. Vessel owner required to submit inspection documentation with in 14days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 26 May 2022
Resolution: Vessel owner had Marmic Fire and Safety service Fire Extinguishers on 26MAY2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 April 2019
Resolved
Improper life jackets on bridge. Replace with approved type.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 26 April 2019
Resolution: Replaced with approved Type I Life Jacket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2019
Resolved
Battery box found full of water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 26 April 2019
Resolution: Emptied water and replaced cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2019
Resolved
Fuel shutoff label and valve direction missing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 26 April 2019
Resolution: Properly Labled fuel emergency shutoff.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2019
Resolved
Light fixture cover missing above engine.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 26 April 2019
Resolution: Replaced Light fixture.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 11 April 2018
Resolved
Alcohol test strips were expired. Replace test strips.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 8 May 2018
Resolution: Alcohol test strips were replaced and not expired. All sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 April 2018
Resolved
All (4) navigation lights (sidelights fore and aft) had partial/missing gaskets and painted over data plates. Replace housing or remove paint and replace gaskets. Verify light bulbs are the proper type.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 8 May 2018
Resolution: Navigation lights were replaced (port and starboard sidelights and all-around white light). New lights meet regulations and range of visibility. All sat.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 April 2016
Resolved
Certificate of Documentation (COD) for uninspected towing vessels that are used to push the LADY MARION was expired. Provide valid COD for PEEL 1 and PEEL 2 ferries.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 12 May 2016
Resolution: Vessel rep. provided Certificate of Documentation for both towing vessels.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 April 2016
Resolved
Found 06 adult lifejackets with unsatisfactory retro-reflective tape. Replace tape or lifejackets to satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 12 May 2016
Resolution: Ring Life Buoys were replaced and retro-reflective tape was properly applied.
Lifesaving › Lifebuoys › Serviceable
Issued 14 April 2016
Resolved
Found 04 Ring Life Buoys with wasted/rotted plugs. Replace with CG approved ring life buoys (approval number 46 CFR 160.060).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 12 May 2016
Resolution: Ring Life Buoys were replaced.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 14 April 2016
Resolved
Vessel does not have means to conduct DOT approved drug/alcohol testing within required time limits. Provide means to conduct testing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 12 May 2016
Resolution: Vessel representative ordered DOT approved alcohol test strips.
Engineering › Bilge Water Management System › Not Operational
Issued 14 April 2016
Resolved
Did not witness operational test of bilge system due to vessel underway with passengers. Conduct operational test of bilge system.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 12 May 2016
Resolution: Witnessed satisfactory test of the bilge system.
Lifesaving › Lifebuoys › Serviceable
Issued 15 January 2015
Resolved
Discovered two Ring Life Buoys that were unserviceable due to the plug wastage. Resulted in water intrusion.
Due 15 January 2015
Resolved 15 January 2015
Resolution: Vessel rep replaced with acceptable buoy in serviceable condition.
Fire Fighting › Portable Foam Applicators › General
Issued 15 November 2011
Resolved
Prior to carrying any Class 3 Flammable or Combustible liquids provide proper fire fighting protection. (B V ext or AFFF). Currently the ferry does carry vehicles with portable tanks of Class 3 flammables. (Portable tanks of Diesel in the beds of farm trucks)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2012
Resolution: Verified proper operation of the two portable fire pumps both with proper foam eductors, variable spray nozzles and an immediately available 5 gallon container of 3% AFFF. This arrangement meets the requirement to carry Class III flammable Liquids
Lifesaving
Issued 11 March 1997
Resolved
Replace grabline on two life rings.
Condition: Unknown
Due 25 March 1997
Resolved 9 May 1997
Accommodation/Occupational Safety
Issued 6 April 1994
Resolved
POST GARBAGE POLLUTION PLACARD ON BOARD.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Fire Fighting
Issued 6 April 1994
Resolved
PRIOR TO PASSENGER OPERATION, PROVE SATISFACTORY OPERATION OF FIRE/BILGE PUMPS, GENERATOR, NAVIGATION LIGHTS AND ATTENDING PROPULSION UNIT TO THE COGNIZANT OCMI.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Fire Fighting
Issued 26 January 1993
Resolved
REMOVE RESIDENTIAL FIRE EXTINGUISHER AND REPLACE WITH PROPER, APPROVED USCGMARINE TYPE BII EXTINGUISHER.
Condition: Unknown
Due 26 January 1993
Resolved 26 January 1993
Unknown
Issued 26 January 1993
Resolved
PROVIDE PROOF OF EMPLOYEE PARTICIPATION IN REQUIRED DRUG/CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 26 January 1993
Resolved 26 January 1993
Lifesaving
Issued 26 January 1993
Resolved
REMOVE TWO UNSERVICABLE RING BOUYS FROM VSL AND REPLACE WITH PROPER, USCG APPROVED RING BOUYS.
Condition: Unknown
Due 26 January 1993
Resolved 26 January 1993
Navigation
Issued 26 March 1992
Resolved
REPLACE ALL NAVIGATION LIGHT BULBS WITH APPROVED BULBS, AS PER APPROVED TYPE NOTE ON FIXTURE.
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Fire Fighting
Issued 26 March 1992
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Electrical
Issued 26 March 1992
Resolved
REMOVE ALL SOLID CORE WIRE, RENEW WITH APPROVED STRANDED WIRE.
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Documentation
Issued 25 April 1990
Resolved
PROVIDE ORIGINAL CERTIFICATE OF INSPECTION ON BOARD.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Fire Fighting
Issued 25 April 1990
Resolved
SERVICE DRY CHEMICAL FIRE EXTINGUISHERS.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Electrical
Issued 25 April 1990
Resolved
PROVIDE BATTERY BOX AND HOLD DOWN BRACKET FOR GENERATOR.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Electrical
Issued 28 March 1989
Resolved
SUPPORT WIRE RUNS IN VOIDS.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Lifesaving
Issued 28 March 1989
Resolved
PROVIDE TWO (2) USCG APPROVED ADULT LIFE PRESERVERS.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Construction/Loadline
Issued 28 March 1989
Resolved
MAKE PERMANENT REPAIRS, WELD INSIDE AND OUT AND DRILL STOP BOTH ENDS OF EACH CRACK, TO TWO FRACTURES IN DECK IN MID SECTION OF VESSEL.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Construction/Loadline
Issued 28 March 1989
Resolved
RENEW SUPPORT BRACKET UNDER DECKHOUSE ON MISSOURI END.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Fire Fighting
Issued 28 March 1989
Resolved
DEMONSTRATE OPERATION OF FIRE PUMP & BILGE PUMP; INSTALL BILGE PIPE STRAINERS 3 TIMES PIPE DIAMETER IN EACH VOID.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Electrical
Issued 28 March 1989
Resolved
MAKE REPAIR TO MAINNN POWER PLUG AT GENERATOR.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Construction/Loadline
Issued 28 March 1989
Resolved
MARK VESSELS NAME VISIBLE FROM BOTH SIDES.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Electrical
Issued 28 March 1989
Resolved
REMOVE HOUSEHOLD WIRE NUTS FROM ALL CONNECTIONS AND INSTALL PRESSURE TYPE CONNECTORS.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989