MAURY USCG vessel records Sign in
← All vessels

CHAMPION TRADER

CHAMPION TRADER is a 1997 tank ship. The Coast Guard has recorded 57 inspections since 1997, most recently in June 2019, along with 35 deficiencies and 17 operational controls.

Records from 1997 to 2019. Most recent: operational control imposed, 16 June 2019.

Built
1997
Last inspected
3 June 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9127667 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
460241
Flag
NORWAY
—
Maury page id
psix-460241

Inspections, by type

…with no type recorded26
Years with a record 18 calendar years (1997–2019)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it21897 - Convention (Subpart B), Gross Ton
12597 - Convention (Subpart B), Net Ton
40727 - Dead Weight, Ton
49123 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 57

3 June 2019 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Activities Europe · Activity 6701754
26 August 2017 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6241916
15 August 2016 ISPS III Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5968277
15 August 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5976493
27 April 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5864316
26 April 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5863351
23 April 2016 Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5856848
30 August 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5230876
21 August 2015 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5222968
16 August 2015 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5211948
10 March 2014 Deficiency Check · PI Safety Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4813339
9 March 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4812592
8 March 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4814287
11 May 2012 ISPS II Exam · COC-CHEM Annual
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4308634
20 January 2011 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3927774
15 January 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3927220
26 December 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3916709
22 December 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3915050
5 March 2010 ISPS II Exam · COC-TVE Annual
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3688157
4 March 2010 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3690177
4 March 2010 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3690201
2 March 2010 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3688878
26 April 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3461365
26 April 2009 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3461371
25 April 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3460333
24 April 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3459926
9 January 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3391138
8 January 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3391198
8 January 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3391213
3 January 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3388061
1 January 2009 COC-CVE Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3387372
20 August 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3303839
25 April 2008 MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · COC-CHEM Annual · PII Safety Exam · Ballast Water Examination · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3192123
24 April 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3191169
19 January 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2858596
18 January 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2857766
18 January 2007 Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2857808
26 October 2006 Ballast Water Examination · COC-CHEM Renew · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2808317
11 July 2006 Type not recorded
No type recorded · Maritime Safety & Security Team Cape Cod (91110) · Activity 2709804
8 February 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2581721
26 January 2006 MARPOL Annex II Examination · COC-TVE Annual · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2572819
20 October 2004 ISPS II Exam · COC-TVE Renew
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2220872
24 February 2004 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2012210
14 February 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2006718
13 November 2003 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1946867
28 August 2003 Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1889550
15 July 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1847683
7 July 2002 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1643656
4 October 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 433253
4 October 1999 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1043442
21 August 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 419555
4 August 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 418757
4 August 1998 MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 795573
5 April 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 414536
29 November 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 410349
19 July 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 405826
19 July 1997 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1119538

Deficiency record · 35

01 - Certificates & Documentation › 013 - Documents › Cargo information
Issued 16 June 2019 Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil or hazardous material shall provide transfer procedures that meet the requirements of CFR parts 155 and 156. Ship is not able to provide transfer procedures that meet the applicable parts with regard to content and shipboard availability.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 July 2019
Resolution: cleared via email
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 16 June 2019 Resolved
Each nonmetallic transfer hose and transfer pipe system must be subjected to a static liquid pressure test of at least l.5 times the maximum allowable working pressure annually. Test records onboard indicate the ship’s cargo piping system and portable hoses were not tested to an adequate pressure within the past year.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 July 2019
Resolution: cleared via email
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 3 June 2019 Resolved
Each hose assembly used for transferring oil or hazardous material must be marked with the maximum allowable working pressure. Additionally the pressure at which the hose was tested must not be marked on the hose. The ship's portable cargo hoses are not marked with the MAWP and are instead marked with the test pressure.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 July 2019
Resolution: cleared via email
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 21 August 2015 Resolved
1499- Piping Systems and fittings shall be of a design and construction adequate for the service for which they are intended. Vessel experienced a fracture of their main hydraulic piping to their cargo framo pumps during transfer operations. Vessel to submit a repair plan to class and local coast guard office fro approval prior to commencing hotwork and all repairs. SOLAS CH.II-1 reg 26.1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2015
Resolved 23 August 2015
Resolution: Vessel Class attested to repairs and proper operation of the FRAMO hydraulic piping system.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 August 2015 Resolved
0820-All electrical apparatus shall be so constructed and installed as not to cause injury when handled or touched in the normal manner. Protective shielding on lighting throughout vessel is broken, cracked and or missing. SOLAS (4) II-1/45 1.3. (17a/c)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 August 2015
Resolved 23 April 2016
Resolution: Received class report stating the lighting fixture shields have been inspected throughout the vessel and the broken, missing, or cracked positions have been replaced/fitted with new ones.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 16 August 2015 Resolved
0950-Exposed metal parts of electrical machines or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed. Grounding lines on machinery throughout vessel not properly installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2015
Resolved 17 August 2015
Resolution: Vessel properly installed grounding wires on machinery equipment.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2015 Resolved
0950-All electrical apparatus shall be so constructed and installed as not to cause injury when handled or touched in the normal manner. Vessel has dead-end wiring and improper electrical installations throughout spaces which may cause injury if handle handled. SOLAS (04) II-1/45 1.3 (40a/c)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 August 2015
Resolved 23 April 2016
Resolution: Received class report stating dead end wiring and improper electrical installation noted during PSC inspection have been dealt with and removed.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 16 August 2015 Resolved
1870-Each vapor collection system flange must have a permanently attached 0.5 inch diameter stud. Vessel did not have 0.5 inch stud permanently attached. 33CFR39.10-1(e) (40a/c)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 August 2015
Resolved 23 April 2016
Resolution: Required 1/2" stud at each vapor collection system flange has been premanently welded at all four locations.
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 16 August 2015 Resolved
0820-Surfaces with temperatures above 220 Celsius which may be impinged as a result of a fuel system failure shall be properly insulated. Boiler feed pump lagging not installed properly resulting in improper insulation.SOLAS (04) II-2/4 2.2.6.1 (10C)
Condition: Improper Installation
Due 17 August 2015
Resolved 17 August 2015
Resolution: Vessel installed proper laggin on boiler feed pump. SOLAS (04) II-2/4 2.2.6.1
Engineering › Generator (propulsion/auxiliary-electric) › Fixture Circuitry
Issued 16 August 2015 Resolved
1430-Main and auxiliary, machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. Emergency generator breaker continued to cycle and emergency generator re-energized while vessel was on main ship's power due to faulty sensor. SOLAS (04) II-1/31 1 (17a/c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2015
Resolved 29 August 2015
Resolution: Received Rina class report verifying proper operation of the emergency generator, deficiency cleared.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 August 2015 Resolved
1499-Machinery, boilers, and other pressure vessels, and associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Vessel had soft patches and pinhole leaks on sea water cooling system, seawater pump piping, seawater cooling exchange to power packs and AC seawater piping.SOLAS(04) II-1/26.1 (17a/c) Class condition accepted.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 April 2016
Resolution: The leaked pipes in way of seawater cooling system have been permanently repaired and replaced with new pipes. After repair pressure tested for the seawater cooling system without leakage.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 16 August 2015 Resolved
0820-The inert gas system shall be designed, constructed and tested in accordance with the Fire Systems Safety Code and to the satisfaction of the administration. Inert gas generator flame extinguished multiple times during star-up testing. SOLAS (04) II-2/4 5.5.3 Code Chapter 15 2.1.2 (40a/c)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 August 2015
Resolved 23 April 2016
Resolution: The IG system has been checked/tested by service engineer at the presence of surveyor and is back to normal operating condition
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 March 2014 Resolved
1740-Oil discharge mon/contr system: Oil filtering equipment refered to in paragraph 2 of this regulation shall be be provided with alarm arrangements to indicate when this level cannot be maintained. The 15PPM bilge alarm will be calibrated and zeroed as per the Manufacturers Instructions. OCM has not been calibrated since 2004. MARPOL Ax.I/14.7 - (17ac) MEPC 107(49)4.2.11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2014
Resolution: Vessel was able to confirm OCM calibration conducted on 28AUG2012 see attached Calibration certificate No. 5016378. This date coincides with IOPP Certificate which was issued 17SEP2012.
Engineering › Compressed Air System (start air) › Piping
Issued 10 March 2014 Resolved
1499-Other (Prop. & Aux. Machinery): The machinery boilers, and other pressure vessels associated piping systems and associated fittings shall be of a design and construction adequate for the service for which they are intended. There is an unauthorized weld on the outlet line of the air reservoirs. In addition, continued in narrative of Activity#4813339 (17ac)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2014
Resolution: Class surveyor issued a recommendation with a validity date of 10JUN2014 for the permanent repairs. Additionally, Ballast line issued a recommendation for permanent repair/replacement due at the shipyard period.
Construction/Loadline › Markings › Load Line Mark
Issued 10 March 2014 Resolved
1299-Other (Load Lines): The ring, lines and letters shall be painted in white or yellow on a dark or in black on a light ground. Found loadline marking rusted and not in contrasting color. ICLL Annex I/8 (40ac)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 March 2014
Resolution: Class Surveyor issued recommendation for load line to be repainted at the first opportunity after the departure from US waters.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 10 March 2014 Resolved
9900-Other (not clearly hazardous): No flammable or combustible liquids may be stowed in any accommodation, control, or service space (Other than Paint Locker). Multiple storage lockers including linen store and engine store had flammable and combustible items stowed inside. 46CFR147.45(b) (10c)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 March 2014
Resolved 10 March 2014
Resolution: Vessel''s crew moved identified flammable and combustible items to Paint locker as designated on Fire Control Plan.
Deck/Cargo › Marine Portable Tanks › Securing Device
Issued 10 March 2014 Resolved
9900-Other (not clearly hazardous): Cylinders must always be secured and when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place. Multiple cylinders are tied in place and do not have proper brackets. 46CFR147.60(b)(I) (10c)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 March 2014
Resolved 10 March 2014
Resolution: Vessel''s crew moved the cylinders identified as full to stowage location with proper brackets.
Engineering › Fuel Oil Service System › Piping
Issued 20 January 2011 Resolved
0710 - Fire Prevention - Means shall be provided to control leaks of flammable liquids. The auxiliary engine for the emergency generator has numerous fuel oil leaks. permanent repairs were made prior to completion of the exam. SOLAS 74a II-2/4
Action required: 705 - Other - as specified
Due 20 January 2011
Resolved 20 January 2011
Resolution: Crew replaced gaskets and leaking fuel hose on the emergency generator prior to the completion of the exam to the satisfaction of the PSCO
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 5 March 2010 Resolved
The inert gas system shall be capable of inerting empty tanks and maintaining the atmosphere in cargo tanks with the required oxygen content. Vessel's IGG could not maintain required oxygen levels.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 March 2010
Resolved 27 May 2010
Resolution: Received class report from RINA surveyor attesting to the satisfactory repair and full function test of the vessel''s inert gas system.
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 April 2009 Resolved
I/B Dev request stating that the primary radr was inoperable. Request granted.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2009
Resolution: Received tech report attesting to the proper operation of the primary radar.
Engineering › Non-conventional Propulsion/Steering › Hydraulic Steering Unit (Azipod)
Issued 8 January 2009 Resolved
The vessel had a propulsion loss due to loss of pitch control in the vessel's Controllable Pitch Propeller
Action required: 705 - Other - as specified
Due 8 January 2009
Resolved 9 January 2009
Resolution: Received class report from BV satisfying requirement.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 18 January 2007 Resolved
Ship provided the inaccurate Notice of Arrival in where the dates of last 5 ports was incorrect date (06 January 2006 for Gibraltar and it should have been 06 January 2007). Submit update to the USCG National Vessel Movement Center with correct date.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2007
Resolution: ANOA was modified to show correct dates.
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 18 January 2007 Resolved
Cargo Record Book for MARPOL Annex II cargos to be updated to reflex the new changes to MARPOL Annex II, prior to loading Annex II Cargo.
Action required: 705 - Other - as specified
Resolved 25 April 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 January 2007 Resolved
Seawater cooling water line in, for inboard cooler for main engine and auxiliary generators has a temporary repair. Class is to approve this temp repair by 18 February 2007.
Action required: 705 - Other - as specified
Due 18 February 2007
Resolved 31 May 2007
Resolution: Temp repair is satisfactory to RINA, permanent repairs to be made at drydock March 2007.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 18 January 2007 Resolved
Forward life raft is missing due to storm. Replace life raft prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2007
Resolved 22 January 2007
Resolution: Received class report from RINA that the raft has been replaced.
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 26 January 2006 Resolved
Inert Gas branch line from top of scrubber has several temporary plastic repairs. Make proper repairs to the satisfaction of class prior to next U.S. port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 February 2006
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 26 January 2006 Resolved
Hand rail around upper platform of the inert gas tower is loose, make proper repairs to the satisfaction of class.
Action required: 705 - Other - as specified
Due 27 February 2006
Resolved 8 February 2006
Resolution: Received Class report from RINA dated 02 Feb 05
Deck/Cargo › Cargo Stowage › General
Issued 29 October 2004 Resolved
Vessel restricted to carrage of Grade "E" cargoes until repair and full operational test of IGS. Vessel to notify MSO Port Arthur upon completion of test.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 November 2004
Resolved 8 December 2004
Resolution: This unit received class report attesting to satisfactory repair, and full operational testing of vsl''s IGS system.
Engineering › Steering Gear System › Pump
Issued 14 February 2004 Resolved
No. 1 Steering Pump broken.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2004
Resolution: Received fax from technitian attesting to repairs to No 1 steering gear pump. Test Sat.
Engineering › Steering Gear System › Feedback Unit
Issued 15 July 2003 Resolved
The steering system hunts 2 to 3 degrees when in two pump operation. Repair to the satisfaction of class or technician prior to movement from anchorage.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 17 July 2003
Resolution: Received technician''''s report and class report from RINA stating deficiency has been rectified.
Pollution Prevention/Response › Prevention Equipment
Issued 15 July 2003 Resolved
The cargo tank overfill alarm panel shows several false readings. Prove proper operation to the satisfaction of class prior to loading cargo in U.S. waters. LEGACY COMPONENT DESC: Overfill Devices
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 17 July 2003
Resolution: Received class report from RINA stating deficiency has been rectified.
Deck/Cargo › Vapor Control Systems
Issued 15 July 2003 Resolved
The Vapor Recovery System manifold flanges are missing the .5" stud at the top position. Provide studs in proper position prior to the use of this system in U.S. waters. LEGACY COMPONENT DESC: Piping/Hoses
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 17 July 2003
Resolution: Received class report from RINA stating deficiency has been rectified.
Deck/Cargo › Inert Gas System
Issued 15 July 2003 Resolved
The IGS deck line pressure sensor does not work. The vessel provided amended transfer procedures to allow manual monitoring of pressure and was allowed a one time discharge operation. The IGS deck line pressure sensor was replaced, but could not be zeroed. LEGACY COMPONENT DESC: Deck Line Pressure Sensor
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 July 2003
Resolved 27 August 2003
Resolution: The condition of class is now deleted and is working satisfactory.
Navigation
Issued 4 August 1998 Resolved
MANUVERING FACT SHEET WAS MISSING BOW THRUSTER INFORMATION, TABLE OF STOPPING DISTANCES, TABLE OF SPEED SETTINGS. 33 CFR 164.35(g)
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Fire Fighting
Issued 19 July 1997 Resolved
FOAM LINE TO MONITORS I.W.O. CARGO TANK NO.7 REQUIRES NEW SEALS. SOLAS 74 AMENDED.
Condition: Unknown
Due 7 December 1997
Resolved 7 December 1997