MAURY USCG vessel records
← All vessels

N.M.S. NO. 1406

N.M.S. NO. 1406 is a 1968 tank barge. The Coast Guard has recorded 23 inspections since 1982, most recently in July 1996, along with 16 deficiencies.

Records from 1982 to 1996. Most recent: inspection, 4 July 1996.

Built
1968
Last inspected
4 July 1996
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 4 July 1996
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 14 calendar years (1982–1996)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-46044

Documentation record

Tonnage as PSIX records it795 - Regulatory (Subpart C or D), Gross Ton
795 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

4 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087213
29 April 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1079985
9 June 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1452037
15 April 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1168087
15 June 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1403645
16 April 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1267668
7 June 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015092
24 May 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 920326
2 May 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 899580
15 November 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1213781
17 May 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1197097
13 May 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1348272
2 June 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1000318
8 May 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 473498
26 August 1986 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1296070
27 June 1986 COI Inspection · Credit Drydock
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 998350
30 May 1986 Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1297358
27 March 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304609
7 March 1985 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 982522
4 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 978124
29 January 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 979291
26 August 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966757
18 January 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963365

Deficiency record · 16

Deck/Cargo
Issued 2 May 1990 Resolved
OPEN ALL P/V VALVES FOR COAST GUARD EXAMINATION IN ACCORDANCE WITH 46 CFR 32.20-5.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Deck/Cargo
Issued 2 May 1990 Resolved
PROVIDE DOCUMENTATION OF TEST FOR STEAM HEATING RELIEF VALVE IN ACCORDANCE WITH 46 CFR 61.15-5(C).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 2 May 1990 Resolved
MAKE PERMANENT REPAIRS TO AREA COVERED WITH LIQUID STEEL ON STARBOARD STERNAT THE 11 FOOT DRAFT IN ACCORDANCE WITH 46 USC 3313(A).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Deck/Cargo
Issued 2 May 1990 Resolved
PROVIDE ADEQUATE PACKING AT DECK PENETRATION OF REACH RODS IN ACCORDANCE WITH 46 CFR 32.50-15.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Deck/Cargo
Issued 2 May 1990 Resolved
REPAIR BROKEN CLOSED GAGING DEVICE TO NO. 2 CENTERLINE CARGO TANK IN ACCORDANCE WITH 33 CFR 155.815.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 2 May 1990 Resolved
MAKE PERMANENT REPAIRS TO 6 BENT DECK FRAMES ALONG STARBOARD SIDE IN ACCORDANCE WITH 46 USC 3313(A).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 2 May 1990 Resolved
MAKE PERMANENT REPAIRS TO TWO HOLED DECK FRAMES AT THE STARBOARD STERN IN ACCORDANCE WITH 46 USC 3313(A).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Deck/Cargo
Issued 2 May 1990 Resolved
SECURE CARGO PUNP ENGING COVER IN ACCORDANCE WITH 46 CFR 32.01-15.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 2 May 1990 Resolved
MAKE PERMANENT REPAIRS TO DECK BRACKET NEXT TO CARGO TANK DOME NO. 1 IN ACCORDANCE WITH 46 USC 3313(A).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 2 May 1990 Resolved
MAKE PERMANENT REPAIRS TO FRACTURES ON BOTH BOW PUSH KNEES IN ACCORDANCE WITH 46 USC 3313(A).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 2 May 1990 Resolved
MAKE PERMANENT REPAIRS TO 24" FRACTURE IN WAY OF PORT CORNER WRAPPER IN ACCORDANCE WITH 46 USC 3313(A).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 2 May 1990 Resolved
MAKE PERMANENT REPAIRS TO 10" AND 5" FRACTURES IN WAY OF PORT STERN CORNER DECK IN ACCORDANCE WITH 46 USC 3313(A).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 30 May 1986 Resolved
GAS FREE AND MAKE TEMPORARY REPAIRS TO THE TWO (2) HOLES IN BOW RAKE EIGHT (8) FEET BELOW HEAD LOG PRIOR TO DEPARTURE FROM CHICAGO, ILLINOIS
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Construction/Loadline
Issued 30 May 1986 Resolved
MAKE PERMANENT REPAIRS TO BOW RAKE NO LATER THAN 30 JUNE 1986. REPAIRS TO BE TO THE SATISFACTION OT THE COGNIZANT [name withheld] O OR D PRODUCTS TO BE CARRIED UNTIL PERMANENT REPAIRS HAVE BEEN COMPLETED.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Deck/Cargo
Issued 7 March 1985 Resolved
MAKE NECESSARY REPAIRS TO BROKEN STEAM LINE
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Deck/Cargo
Issued 7 March 1985 Resolved
INSTALL AND TEST STEAM LINE RELIEF VALVE.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.