Documentation record
Registered dimensions (L × B × D)52.6 ft × 14.0 ft × 7.5 ft
Registered tonnagegross 43 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1963
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN PEDRO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 4 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
23 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 17 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
9 July 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8113334
29 October 2024
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8026488
27 August 2024
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7926470
19 July 2024
Examination of Repairs · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7962282
8 July 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7926467
10 July 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7709696
27 July 2022
Deficiency Check · Internal Structural Exam · Hull Examination · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7517904
12 April 2022
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7422479
9 July 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7250992
17 November 2020
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7096540
1 June 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6963767
19 June 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6679142
20 November 2018
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6576743
16 May 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6388217
24 March 2017
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6105512
25 October 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6017814
20 July 2016
Simplified Stability Test · Plan Review "T" Boat · Initial Certification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6016244
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 October 2024
Resolved
Repairs to the hill that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] was notified of a repair to the vessel's deck and had not approved written specs describing details of the proposed repair.
46 CFR 176.700(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 29 October 2024
Resolution: Vessel provided proposed repair to the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferable from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve. MI observed fuel shutoff at the tank connection does not have means to be manually operated from outside the space. Vessel must submit plans for modification.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2023
Resolved 2 August 2023
Resolution: Fuel shutoff relocated and properly closes from outside space.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 July 2023
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18) (incorporated by reference; see 46 CFR 175.600). Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. MI observed both forward bench stowage areas for life jackets missing identification of items stowed inside. Mark locations of all PFDS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2023
Resolved 28 July 2023
Resolution: Labels renewed/replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 July 2023
Resolved
A hatch cover must have securing devices. MI observed engine room maintenance hatch missing means of securing hatch. Provide securing device to hatch cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2023
Resolved 28 July 2023
Resolution: Securing devices added to E/R hatch
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 10 July 2023
Resolved
Where a flexible fill pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. Such hose must overlap metallic pipe ends at the least 11/2 times the pipe diameter and must be secured at each end by clamps. The flexible section must be accessible and as near the upper end of the fill pipe as practicable. When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. MI observed grounding wire missing from fuel tank fill pipe. Provide grounding wire for fill pipe.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2023
Resolved 28 July 2023
Resolution: Bonding wire applied
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2023
Resolved
Conductors in power and lighting circuits must be No. 14 American Wire Gauge (AWG) or larger. MI observed undersized power wiring for deck lights. Replace wiring with proper 14 AWG boat wire or remove installation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2023
Resolved 28 July 2023
Resolution: Proper 14AWG installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 April 2022
Resolved
A vessel must have at least one ring life buoy fitted with a lifeline. Inspector found that the lifeline and grab line on the aft ring life buoy were deteriorated and not fit for service.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 12 April 2022
Resolution: The grab line and throw line on the aft ring buoy were replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 April 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Chart, U.S. Coast Pilot [name withheld] List, Tide Tables and Current Tables. Inspector found that the paper navigation charts and navigation publications were not up-to-date.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 12 April 2022
Resolution: Updated paper navigation charts and navigation publications placed on board the vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 April 2022
Resolved
Electrical equipment on a vessel must be installed to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. Inspector found wire connections within the steering console to be made with electrical tape and twist cap connectors. Also, bare electrical wires were found exposed at the connections.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 12 April 2022
Resolution: Electrical wires secured with heat shrink water tight connections and bare wires repaired.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 12 April 2022
Resolved
A vessel must comply with the applicable requirements for any radio installation including the requirements for a station license and installation certificate issued by the Federal Communications Commission. Inspector found that the Radiotelephony Certificate was expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 12 April 2022
Resolution: A certified FCC surveyor issued a valid Radiotelephony Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2020
Resolved
46 CFR 180.70(d)(3) 10c
Each floating water light must be attached to the lanyard with a corrosion-resistant clip. Water light clip was corroded and could not open. Vessel must replace corroded clip with new, water-resistant clip.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 June 2020
Resolution: Vessel's crew replaced corroded clip with a new clip on hand.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 June 2019
Resolved
A visual and audible alarm must be provided at the operating station for bilge high level. Forepeak visual alarm is inop.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 19 June 2019
Resolution: Vessel replaced inop alarm indicator
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 June 2019
Resolved
Repair gasket for engine room hatch to make weathertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 19 June 2019
Resolution: Vessel replaced gasket.
Engineering › Bilge Water Management System › Piping
Issued 24 March 2017
Resolved
Replace PVC piping used in bilge system in the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2017
Resolved 24 March 2017
Resolution: Corrected during inspection.
Engineering › Sea-water System (primary cooling) › Valve
Issued 24 March 2017
Resolved
Replace PVC plugs in unused sea valve hull connections with metal plugs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2017
Resolved 24 March 2017
Resolution: Corrected during inspection.
Engineering › Bilge Water Management System › Strainer
Issued 24 March 2017
Resolved
Provide strainer on the engineroom bilge suction foot.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2017
Resolved 24 March 2017
Resolution: Corrected during inspection.