MAURY USCG vessel records
← All vessels

APEX 2100

APEX 2100 is a 1968 tank barge. The Coast Guard has recorded 31 inspections since 1982, most recently in July 1991, along with 7 deficiencies.

Records from 1982 to 1991. Most recent: inspection, 25 July 1991.

Built
1968
Last inspected
25 July 1991
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 35 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 25 July 1991
…with no type recorded18
Operational controls None recorded without a removal date
Years with a record 9 calendar years (1982–1991)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-46058

Documentation record

Tonnage as PSIX records it1153 - Regulatory (Subpart C or D), Gross Ton
1153 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

31 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 31

25 July 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 940367
24 February 1991 Permit to Proceed
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 923386
23 February 1991 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 491597
24 November 1990 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 465433
15 November 1990 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 929364
3 October 1990 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 438653
18 August 1990 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 438156
28 March 1990 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 919668
23 March 1990 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 908805
16 February 1990 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 534502
9 February 1990 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 489725
24 July 1989 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 521654
3 February 1989 Re-Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1034469
16 January 1989 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1197224
10 November 1988 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1202460
29 September 1988 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1045380
17 September 1988 Permit to Proceed
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1042618
31 March 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1044008
4 March 1988 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 439865
28 November 1987 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 454631
25 September 1987 Deficiency Check · MARPOL Annex II Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010860
17 September 1987 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 486824
17 September 1987 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1314607
4 March 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325154
16 January 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 534065
23 December 1986 Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1027071
15 April 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307899
18 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286033
8 March 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970516
6 March 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281603
19 October 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964066

Deficiency record · 7

Construction/Loadline
Issued 23 March 1990 Resolved
STERN CAVAL PLATE FRACTURED AT DECK LEVEL
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Deck/Cargo
Issued 23 March 1990 Resolved
"DANGER KEEP OUT" SIGNS NEED TO BE PAINTED AT ALL BUTTERWORTH OPENINGS.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Construction/Loadline
Issued 23 March 1990 Resolved
8-10 INCH FRACTURE ON STARBOARD BOW WRAPPER AT DECK LEVEL
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Construction/Loadline
Issued 16 January 1989 Resolved
OFFLOAD CARGO, GAS FREE AND CONDUCT PERMANENT WELDED REPAIRS TO AN 8 INCH CRACK INWAY OF THE N0. 3 PORT CARGO TANK.
Condition: Unknown
Due 16 January 1989
Resolved 16 January 1989
Construction/Loadline
Issued 17 September 1987 Resolved
MAKE PERMANENT REPAIRS TO A FRACTURE LOCATED IN THE FORWARD RAKE.FRACTURE IS NEAR THE 5' DRAFT MARK ON THE STBD SIDE.REPAIRS ARE TO BE COMPLETED PRIOR TO THE CARRIAGE OF ANY CARGO.
Condition: Unknown
Due 17 September 1987
Resolved 17 September 1987
Construction/Loadline
Issued 6 March 1983 Resolved
AFTER DISCHARGING PRESENT CARGO AND BEFORE LOADING NEW CARGO, GAS FREE BOW VOID AND MAKE AVAILABLE FOR COAST GUARD INSPECTOR.
Condition: Unknown
Due 6 March 1983
Resolved 6 March 1983
Unknown
Issued 6 March 1983 Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL APEX 2100, DN517289
Condition: Unknown
Due 6 March 1983
Resolved 6 March 1983

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.