MAURY USCG vessel records Sign in
← All vessels

ONEGO BAY

ONEGO BAY is a 1989 freight ship. The Coast Guard has recorded 32 inspections since 1999, most recently in May 2007, along with 18 deficiencies and 9 operational controls.

Records from 1999 to 2007. Most recent: inspection, 3 May 2007.

Built
1989
Last inspected
3 May 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8702874 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
460594
Flag
CYPRUS
—
Maury page id
psix-460594

Inspections, by type

…with no type recorded17
Years with a record 5 calendar years (1999–2007)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1372 - Convention (Subpart B), Net Ton
3186 - Convention (Subpart B), Gross Ton
4183 - Dead Weight, Ton
6195 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

3 May 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2921278
2 May 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2921044
17 April 2007 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2909634
14 April 2007 Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2907818
13 April 2007 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2907467
15 March 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2888738
13 October 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2800085
7 September 2006 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2771873
19 August 2006 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2752873
16 August 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2750031
5 August 2006 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2737313
5 August 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2739151
27 January 2006 MARPOL Annex I Examination · ISPS III Exam · Deficiency Check · Ballast Water Examination · PI Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2574447
26 January 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2574320
26 January 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2576270
24 January 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2572720
24 January 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2584281
20 November 2005 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2537867
3 November 2005 MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2527522
19 September 2005 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2496390
12 September 2005 Random ISPS/MTSA/PSC · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2490738
8 September 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2487446
6 June 2005 Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2378303
3 June 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2378324
30 March 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2361128
18 February 2005 ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2294349
4 January 2005 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2268805
31 July 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2151346
28 July 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2147722
23 April 2004 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2051210
20 March 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2029581
24 February 1999 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 425903

Deficiency record · 18

Deck/Cargo › Mooring/Anchoring › Winch
Issued 3 May 2007 Resolved
The vessel was granted a deviation from the rules, allowing operation in the Sector New Orleans COTP zone with an inoperative anchor windlass.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2007
Resolved 3 May 2007
Resolution: Received class report from Lloyd''s Register satisfying requirement.
Navigation › Piloting/Steering › Gyro Compass
Issued 13 April 2007 Resolved
Vessel's gyrocompass inoperable. Issued a Letter of Deviation for inbound transit in daylight only. An operational control is imposed on the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2007
Resolved 17 April 2007
Resolution: Received tech report stating that the gyrocompass was repaired and working normal. Removed operational control.
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 January 2006 Resolved
The auxiliary generator salt water cooling pump discharge lines have cement patches at the discharge flanges. Repair pipes and prove proper operation to the satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2006
Resolved 10 February 2006
Resolution: Received class report stating that the spool piece was replaced tested and found satisfactory.
Engineering › Sea-water System (primary cooling) › Pump
Issued 27 January 2006 Resolved
The main engine salt water cooling pump #2 suction line has a cement patch at the flange. Repair pipe and prove proper operation to the satisfaction of class. 10 FEB 06, received class report stating that the patch was re-enforced with steel, tested and found satisfactory and a condition of class was given to permanently repair at next drydock 04/06.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 7 September 2006
Resolution: VESSEL HAD REPORTS FROM DRYDOCK WHERE CLASS STATED REPAIRS WERE COMPLETED
Deck/Cargo › Ballast › Piping
Issued 27 January 2006 Resolved
The ballast discharge line by way of ballast valve #47 has a leaking temporary band clamp patch. Repair pipe and prove proper operation to the satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2006
Resolved 10 February 2006
Resolution: Received class report stating that the spool piece was replaced tested and found satisfactory.
Fire Fighting › Fire Main › Condition
Issued 27 January 2006 Resolved
The fire main between #2 main engine salt water cooling pump and the main engine has a temporary band clamp patch. Repair pipe and prove proper operation to the satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2006
Resolved 10 February 2006
Resolution: Received class report stating that the spool piece was replaced tested and found satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 January 2006 Resolved
The #3 group starter panel has an added wire for the potable fresh water pump indicator from the panel on first level of the engine room to the second level outside the engine control room. Provide class attestation as to the integrity of this arrangement.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2006
Resolved 10 February 2006
Resolution: Received class report stating that the wire was removed and the system tested tested and found satisfactory.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 January 2006 Resolved
The 220v feeder panel has a full ground in the (s) circuit. Remove ground to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2006
Resolved 10 February 2006
Resolution: Received class report stating that the ground was removed and the system tested tested and found satisfactory.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 27 January 2006 Resolved
The main engine failed while transiting in the Mississippi River. This was the second propulsion failure during this port call. The cause of the failure was a scavenging air box fire at the #1 and 2 cylinders. A manufacturer's tech rep. boarded the vessel and has recommended a complete engine inspection and overhaul. The vessel is required to carry out repairs either at a lay berth or with a tug s
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 January 2006
Resolved 10 February 2006
Resolution: Received class report stating that the main engine was overhauled, inspected and tested wiyh satisfactory results.
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 27 January 2006 Resolved
MDO day tank suction valve (remotely operated)for the auxiliary generators is wired open and cannot be shut down from outside the space as required. Remove wire and prove proper operation to the satisfaction of class.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 January 2006
Resolved 10 February 2006
Resolution: Received class report stating that the was repaired tested and found satisfactory.
Engineering › Steering Gear System › Rudder
Issued 27 January 2006 Resolved
The rudder post packing is leaking extensively while static or while moving. Repair and prove proper operation to the satisfaction of class. 10 FEB 06, received class report stating that the leaks were reduced to an acceptable level and a condition of class was issued to repair at the next drydock 04/06.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 7 September 2006
Resolution: VESSEL HAD REPORTS FROM DRYDOCK WHERE CLASS STATED REPAIRS WERE COMPLETED
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 27 January 2006 Resolved
During the expanded exam of the engineering maintenance system with the Lloyd's Register surveyor no maintenance records could be found as required. In addition, after an inspection of the engine room and machinery spaces, there is an obvious lack of maintenance. Based on the objective evidence found, the PSCO felt that the SMS wrt the engineering maintenance has failed and requested an ISM audit.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2006
Resolved 10 February 2006
Resolution: Received audit report from Lloyd''s Register satisfying requirement. See narrative for details.
Fire Fighting › Structural - Horizontal Zones › General
Issued 12 September 2005 Resolved
ENSURE CLASS A AND CLASS B BOUNDRIES ARE LABELED ON THE FIRE CONTROL PLAN AND ALL COPIES OF SUCH
Action required: 705 - Other - as specified
Due 12 October 2005
Resolved 19 September 2005
Resolution: lloyds approved changes
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 12 September 2005 Resolved
PROVIDE ORIGONAL COFR OR AN AUTHORIZED COPY ONBOARD VESSEL
Action required: 705 - Other - as specified
Due 26 September 2005
Resolved 19 September 2005
Resolution: lloyds approved changes
Engineering › Generator (propulsion/auxiliary-electric) › Battery Charging Circuitry
Issued 12 September 2005 Resolved
ENSURE EMERGENCY GENERATOR IS CAPABLE OF BEING STARTED AS REQUIRED IN SOLAS 74/78 REG 44
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2005
Resolved 19 September 2005
Resolution: lloyds approved changes
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 6 June 2005 Resolved
Vessel must have ship specific ballast water management plan on board.
Action required: 705 - Other - as specified
Due 6 July 2005
Resolved 12 September 2005
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 6 June 2005 Resolved
Vessel must provide mechanical means of closure for fuel oil, bulk lubricating tank vents, over flow and fill pipe containment.
Action required: 705 - Other - as specified
Due 6 July 2005
Resolved 12 September 2005
Deck/Cargo › Holds/Tanks › Coaming
Issued 24 February 1999 Resolved
Fuel vent flange connection position outside area of the containment, Containment is not adequate in volume for numbers of fuel vent enclosed in each containment area. _x001C_
Condition: Unknown
Due 24 March 1999
Resolved 18 February 2005
Resolution: During the course of the inspection, the boarding team cleared the outstanding deficiency

Ownership record