MAURY USCG vessel records
← All vessels

G. T. COAST TRADER

Built
1968
Last inspected
29 March 2015
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 29 March 2015
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (1985–2015)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
2700 - Regulatory (Subpart C or D), Gross Ton 2700 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-46075
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

PROTECTOR Towing Vessel · MISLE 122955 · 24 February 2001 · activity 188314

Inspection history · 23

29 March 2015 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5092382
24 February 2001 Type not recorded
No type recorded · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 188314
10 February 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 852915
6 December 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 959273
5 December 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253377
23 July 1990 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1237339
1 May 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1212970
22 November 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 923040
8 November 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 925212
3 February 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1194093
21 December 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1198020
8 December 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1204508
15 November 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 893466
23 June 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 895390
15 January 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1012706
5 November 1987 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332987
29 April 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321302
24 March 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1017341
18 February 1987 Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1323095
4 February 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304883
23 December 1985 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1303748
23 December 1985 Credit Drydock · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1303750
12 April 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289141

Deficiency record · 32

Fire Fighting
Issued 8 November 1989 Resolved
HAVE BII FIRE EXTINGUISHER IN GALLEY SPACE HYDROSTATICALLY TESTED. LAST HYDRO WAS NOVEMBER 1980.
Condition: Unknown
Due 8 November 1989
Resolved 8 November 1989
Documentation
Issued 8 November 1989 Resolved
MAKE AVAILABLE FOR CG INSPECTOR IOPP CERTIFICATE FOR ANNUAL ENDORSEMENT.
Condition: Unknown
Due 8 November 1989
Resolved 8 November 1989
Lifesaving
Issued 8 December 1988 Resolved
CORRECTLY INSTALL HYDROTATIC RELEASE FOR INFLATABLE LIFERAFT.
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Lifesaving
Issued 8 December 1988 Resolved
PROPERLY MOUNT RING BUOYS
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Electrical
Issued 8 December 1988 Resolved
PROFIDE RUBBER MAT FOR UNDER CENTRAL DISTRIBUTION PANEL
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Navigation
Issued 8 December 1988 Resolved
REPLACE NAVIGATION LIGHTS WITH PROPER CG. APPROVED NAVIGATION LIGHTS AND PROVE PROPER OPERATION OF NAVIGATION LIGHTS.
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Deck/Cargo
Issued 8 December 1988 Resolved
DEMONSTRATE RELEASE OF ANCHOR
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Accommodation/Occupational Safety
Issued 5 November 1987 Resolved
CROP AND RENEW GOOSENECK VENT ON FRESH WATER TANK AND PROVIDE NEW INSECT SCREEN.
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987
Electrical
Issued 5 November 1987 Resolved
PROVIDE INSULATING LAGGING ON GENERATOR EXHAUST IN WAY OF ELECTRICAL CABLES
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987
Deck/Cargo
Issued 5 November 1987 Resolved
PROVIDE OIL FREE EXHAUST LAGGING ON HTDRAULIC SYSTEM ENGINE.
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987
Electrical
Issued 24 March 1987 Resolved
MAKE EXTERIOR LIGHTS FOR REMOTE OPENING DEVICES WATERTIGHT.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Accommodation/Occupational Safety
Issued 18 February 1987 Resolved
RENEW VENT CLOSURE AT TOP OF MACHINERY SPACE HOUSE.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Accommodation/Occupational Safety
Issued 18 February 1987 Resolved
REMOVE PORTABLE PROPANE TANKS FROM VESSEL.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Construction/Loadline
Issued 18 February 1987 Resolved
FREE UP DOGS AND SECURE ALL CARGO HATCHES.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Electrical
Issued 18 February 1987 Resolved
RENEW FORWARD RUNNING LIGHT CABLE IN WAY OF STO CABLE AND SPLICE IN PROPER JUNCTION BOX.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Construction/Loadline
Issued 18 February 1987 Resolved
PROVIDE A FIXED BILGE PIPING SYSTEM FOR THE FORWARD AND AFTER RAKES.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Electrical
Issued 18 February 1987 Resolved
PROVIDE PERSONNEL GUARD ON GENERATOR FRONT SHAFT.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Engineering
Issued 18 February 1987 Resolved
CLEAN OR RENEW DIESEL FUEL TANK FLAME SCREEN.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Electrical
Issued 18 February 1987 Resolved
PROPERLY SECURE GENERATOR MUFFLER.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Documentation
Issued 18 February 1987 Resolved
MAKE VESSEL'S DOCUMENTATION CERTIFICATE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Fire Fighting
Issued 18 February 1987 Resolved
PROVIDE CURRENT FIREFIGHTING EQUIPMENT REPORT. ITEMS TO BE COMPLETED PRIORTO REISSUANCE OF COI.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Lifesaving
Issued 18 February 1987 Resolved
PROVIDE CURRENT LIFERAFT AND HYDROSTATIC RELEASE SERVICING REPORT.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Navigation
Issued 18 February 1987 Resolved
PROPERLY INSTALL NAVIGATION LIGHTS WITH FIXTURES APPROVED UNDER 1972 CERTIFICATE OF INSPECTION REGULATIONS. ITEM IS TO BE COMPLETED PRIOR TO REISSUANCE OF CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Electrical
Issued 18 February 1987 Resolved
PROPERLY SECURE GENERATOR FUEL LINE FROM DIESEL FUEL TANK.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Electrical
Issued 18 February 1987 Resolved
CLOSE OPENINGS IN NAVIGATION LIGHT CIRCUIT BREAKER PANEL.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Electrical
Issued 18 February 1987 Resolved
RENEW SHUT-OFF VALVE ON GENERATOR FUEL TANK LINE.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Construction/Loadline
Issued 18 February 1987 Resolved
PROVE PROPER OPERATION OF VESSEL'S ANCHOR. ITEM TO BE COMPLETED TO REISSUANCE OF CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Electrical
Issued 18 February 1987 Resolved
REPAIR FUEL AND OIL LEAKS ON VESSEL'S GENERATOR AND CHANGE OUT FUEL OIL LINES WITH COAST GUARD APPROVED TYPE. ITEM TO BE COMPLETED PRIOR TO REISSUANCE OF CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Electrical
Issued 18 February 1987 Resolved
PROPERLY HAND WIRE GENERATOR OUTPUT TO DISTRIBUTION PANEL INCLUDING GENERATOR CIRCUIT NREKER. ITEM TO BE COMPLETED PRIOR TO REISSUANCE OF CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Electrical
Issued 18 February 1987 Resolved
REMOVE DEAD ENDED ELECTRICAL CABLES FROM GENERATOR AND AUXILIARY DIESEL ENGINE.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Electrical
Issued 23 December 1985 Resolved
PROPERLY CHOCK AND PROVIDE CORROSION RESISTANT BATTERY TRAYS FOR ALL BAT- TERIES.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
RENEW WITH APPROVED CABLE ALL WIRING FROM BATTERIES ITS DISTRIBUTION PANELS, GENERATOR, HYDRAULIC PUMP, ENGINE AND BATTERY CHARGER.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.