FOUR C'S is a 1968 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2017, most recently in April 2025, along with 82 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 21 April 2025.

Built
1968
Last inspected
21 April 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 April 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH7891
Flag
UNITED STATES
Maury page id
psix-46085

Documentation record

Registered dimensions (L × B × D)73.7 ft × 17.9 ft × 8.4 ft
Registered tonnagegross 68 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · CROWN POINT, LA, UNITED STATES · built 1968
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Regulatory (Subpart C or D), Gross Ton
46 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BULL RED Offshore Supply Vessel · MISLE 211747 · 31 January 2020 · activity 6904224

Inspection history · 17

21 April 2025 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8104130
27 January 2025 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8070278
15 March 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7879834
13 April 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7666001
22 March 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7655496
27 February 2023 Administrative Inspection · Drydock Extension
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7640519
17 May 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7453159
11 March 2021 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7154152
23 February 2021 COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7143040
26 January 2021 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7131076
26 June 2020 Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6987494
14 April 2020 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6939141
31 January 2020 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6904224
14 February 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6626143
9 July 2018 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6473584
28 March 2018 Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6380232
23 February 2017 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6093117

Deficiency record · 82

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 April 2025 Resolved
A self priming, power driven fire pump must be installed on each vessel: of more than 19.8 meters (65 feet) in length. Marine inspector observed fire main inoperable. 46 CFR 181.300(a)(iii)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: tested power driven fire pump. all sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 21 April 2025 Resolved
Marine employers must establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Marine Inspector observed Consortium enrollment expired. Vessel Employer shall ensure all crewmembers employed are enrolled in random chemical testing for dangerous drugs. 46 CFR 16.230
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: Vessel displayed proof of enrollment for all crew members. all sat.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 21 April 2025 Resolved
Licenses for ship stations in the maritime services will normally be issued for a term of ten years from the date of original issuance, or renewal. Marine Inspector observed FCC Station license expired. Vessel shall contact and FCC certified technician to renew listed certificate. 47 cfr 80.25
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: vessel had fcc tech onboard to issue new cert.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 April 2025 Resolved
At every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter. Marine Inspector observed excessive oil in the bilge and crewmembers actively pumping ashore. 46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: bilge was clean and clear with oil remove. all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 April 2025 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Marine Inspector was unable to test bilge pump suction due to defieicny number 4, vessel had excessive oil in engine room bilges. Vessel owner/operator shall ensure bilges are clean and clear to ensure bilge pumps are operational. 46 CFR 182.520(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: tested all bilge suction. all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 April 2025 Resolved
Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers. Marine Inspector observed fire servicing technician report missing and fire extinguisher tags indicated the expiration of the fire extinguishers were April 2025. Vessel owner/operator shall have annual inspection conducted prior to def check for remaining deficiencies listed below. 46 CFR 176.810 (b)(1)(i)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2025
Resolved 24 April 2025
Resolution: Vessel rep had fire fighting extinguishers serviced with proof of servicing. All sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 April 2025 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Marine inspector observed expiration date of April 2025. Vessel needs to replace prior to def check for remaining deficiencies listed below. 46 CFR 185.740(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2025
Resolved 24 April 2025
Resolution: new HRU was purchased and installed on EPIRB.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2024 Resolved
At each initial and subsequent inspection for certification of a vessel the owner or managing operator shall test operation of the means provided for pumping bilges. Marine Inspector observed failed test of fwd peak space and oily water in crew space bilge. Fix and test satisfactory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2024
Resolution: Marine Inspector attended vessel and watched satisfactory test of bilge suction system from all applicable spaces.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 May 2024 Resolved
At each inspection for certification and at every other vessel inspection all hazardous situations must be corrected. Marine Inspector observed bilge space under berthing to contain oily water. Clean out.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2024
Resolution: Vessel's crew pumped out and cleaned. Marine Inspector examined and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2024 Resolved
For each 21,000 U.S. gal or any flammable or combustible liquid being transported on board a vessel in a portable tank at least one fire hose fitted with an approved portable mechanical form nozzle with pick-up tube. Vessel Master self reported foam nozzle and pick-up tube was not working. Replace/repair.
Action required: 705 - Other - as specified
Resolved 24 May 2024
Resolution: Marine Inspector attended vessel and observed satisfactory test of eductor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 14 May 2024 Resolved
At each inspection for certification and at every other vessel inspection the owner or managing operator shall have ready for inspection all watertight closures in the deck and bulkheads. Engine room door does not have correct gasket and fore peak hatch has a ripped gasket. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 20 May 2024
Resolution: Vessel's crew replaced. Marine Inspector examined and found satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 May 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's anchor light is extinguished. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 20 May 2024
Resolution: Vessel's crew replaced. Marine Inspector examined and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 April 2024 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Marine Inspector observed expired firefighting servicing report. Have servicing done.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel rep. supplied servicing report. Marine Inspector reviewed and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 April 2024 Resolved
Portable extinguishers must be inspected and maintained IAW NFPA 10. Marine Inspector observed engine room fire extinguisher gauge to be in the red. Replace.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel rep. supplied new extinguisher. Marine Inspector inspected and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 2 April 2024 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Marine Inspector observed expired batteries in the water light attached to the life float. Replace.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel rep. supplied new battery. Marine Inspector inspected and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 April 2024 Resolved
Ladders provided to aid escape must be fixed unless able to be brought into immediate service. Escape ladder for the engine room to the deck not on board. Place on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel rep. supplied ladder. Marine Inspector inspected and found satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 April 2024 Resolved
At each inspection Marine Inspector may require a man overboard drill. Perform prior to operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel crew performed satisfactory man overboard drill.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 April 2024 Resolved
At each inspection Marine Inspector may require a man overboard drill. Perform prior to operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel crew performed satisfactory fire drill.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 April 2024 Resolved
At each inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected and in satisfactory condition. Marine Inspector observed a strong odor of fuel in the lazarette. Investigate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel crew cleaned bilge. Marine Inspector examined and found satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 April 2024 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high "EMERGENCY EXIT KEEP CLEAR." Marine Inspector observed the emergency escape in engine room not properly labeled. Label.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel crew labeled. Marine Inspector examined and found satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 April 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessels Captain self reported that the vessels mast head light was out. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel crew replaced. Marine Inspector examined and found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2024 Resolved
A suitable marine type strainer shall be fitted in the fuel supply line in the engine compartment. Marine Inspector observed missing metal bowl under the filter for the starboard main engine. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel crew replaced. Marine Inspector examined and found satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 April 2024 Resolved
Vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Marine Inspector observed a lack of current charts readily available. Have on board. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel crew procured. Marine Inspector examined and found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 March 2024 Resolved
The shutoff valve must be manually operable from the outside the compartment. Marine Inspector observed the shutoff valve corroded and unable to move. Repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel rep. repaired. Marine Inspector inspected and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 March 2024 Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, or designated crew member. Marine Inspector observed last record to be in 2022.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel crew completed current months inspection. Marine Inspector examined and found satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 15 March 2024 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station must carry a radio operator who holds a marine radio operator permit. Marine Inspector was informed by Captain that they did not have it on them. Have on board. 47 CFR 80.159(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel master had onboard. Marine Inspector examined and found satisfactory.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 March 2024 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident shall comply with 46 CFR 4.06 regarding alcohol testing. Vessel doesn't have a means to test. Obtain an approved method to test for alcohol. 46 CFR 185.212
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel crew procured. Marine Inspector examined and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 April 2023 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Engineroom bilge contained excessive water in bilge mixed with diesel fuel from recent fuel filter changes. Crew to pump bilge to an approved facility. 46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2023
Resolution: Bilge was dewatered.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2023 Resolved
All unfired pressure vessels must be installed to the satisfaction of the cognizant [name withheld] compressor and tank located in passenger compartment void was not secured in place. 46 CFR 182.330
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2023
Resolution: Secured in place.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 13 April 2023 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. Engine room over board bilge piping flex hose at side shell was damaged. 46 CFR 182.25-1 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2023
Resolution: Flex hose replaced.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 April 2023 Resolved
The fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Deck cap was seized. 46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2023
Resolution: Main deck cap protecting reach rod was freed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2023 Resolved
Exhaust gas must not leak from the piping or any connections. Starboard MDE outboard turbo to exhaust pipe was covered in soot indicating a leak. 46 CFR 182.430 (b).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2023
Resolution: Turbo clamp was tightend.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2023 Resolved
For each 21,000 U.S. gallons or part thereof of any Class 3 (flammable) or combustible liquid being transported on board a vessel in a portable tank there must be provided a fire hose fitted with an approved portable mechanical foam nozzle with pick-up tube. Vessel's pick up tube was inoperable. 49 CFR 176.315(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: The vessel's pick-up tube has been successfully restored to full operational status.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 13 April 2023 Resolved
Each light fixture must protect crew from electrical hazards. Two overhead light fixtures in accomodation spaces were missing covers and electrical j-box in head was missing an outlet cover. 46 CFR 183.200(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: light fixtures throughout have been fitted with appropriate covers, and the electrical box located in the head has been equipped with a secure outlet cover.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 April 2023 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Cargo deck hatch leading out of engine room was painted yellow, but needed stenciled. 46 CFR 185.606
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Inspected and labeled in accordance with safety regulations and industry standards. All exit points are now clearly marked with visible and durable signage indicating their use as means of escape.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 April 2023 Resolved
The master of the vessel shall ensure tha each EPIRB be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative and be logged. Vessel's log book did not show proof of EPIRB tests. 46 CFR 185.728(c).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Logbook has been thoroughly reviewed and updated as per the latest maintenance and inspection protocols. All relevant data entries, including test results have been recorded.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 April 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Chart provided was several years old showing no signs of being updated. 46 CFR 184.420(a)(1).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: New up to date charts were purchased and placed o/b
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 13 April 2023 Resolved
The master of a vessel shall have examined and tested the steering gear, signaling whistle, propulsion controls, and communication systems of the vessel prior to getting underway for a voyage, except that such examination and testing need not be conducted more than once in any 24 hour period. Master was not aware of required tests. 46 CFR 185.320.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Prior to conducting drills the Master was profficient in their duties
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 13 April 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted or made available to the crew and passengers. One set of instructions was faded and difficult to read. 46 CFR 185.516(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2024
Resolution: Instructions were posted and clearly visible
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 May 2022 Resolved
The hydrostatic release unit for the EPIRB is not marked with an expiration date. 46 CFR 185.740(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 24 May 2022
Resolution: New hydrostatic release for EPIRB installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2022 Resolved
Battery lid is missing. 46 CFR 183.05-20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 24 May 2022
Resolution: Replaced battery lid
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2022 Resolved
Main diesel engines do not have machinery guards. 46 CFR 177.35-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 24 May 2022
Resolution: Machinery guards installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2022 Resolved
F/O shut off valves on vessel were unable to open/close. 46 CFR 182.20-40 (3)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2022
Resolved 24 May 2022
Resolution: Deficiency rectified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2022 Resolved
Exhaust lagging is missing exposing hot pipes. 46 CFR 182.15-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 24 May 2022
Resolution: New lagging installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 May 2022 Resolved
Battery for light is expired on 02 life floats. 46 CFR 180.175(4)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2022
Resolved 24 May 2022
Resolution: Deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 17 May 2022 Resolved
01 ring buoy is unserviceable and needs to be replaced. 01 ring buoy cork needs to be repaired/replaced. 46 CFR 180.70
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2022
Resolved 24 May 2022
Resolution: Deficiency rectified
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 February 2021 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR. HAtch leading out of the engine room onto the cargo deck was not stenciled. 46 CFR 185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 11 March 2021
Resolution: Stenciling was applied to hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 February 2021 Resolved
A vessel of more than 65 feet in length must carry at least one rescue boat unless the cognizant OCMI determines that the vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. Rescue ladder when deployed was at an angle not capable of recovering a helpless person from the water. 46 CFR 180.210.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 11 March 2021
Resolution: Rescue platform was provided with stand off pipes to keep ladder in a vertical position while climbing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 February 2021 Resolved
Each vessel that relies on electricity to power vital loads must be arranged so that the loads can be energized from two sources of electricity. Fire pump could not be energized from the port generator. 46 CFR 183.310
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 11 March 2021
Resolution: Fire pump motor was causing an overloading condition on port generator when energized. Crew swapped out fire pump motor and tested satisfactory while 73 psi and fire pump.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 23 February 2021 Resolved
Gauges to indicate jacket water discharge temperature, must be provided for all propulsion engines installed in the vessel. Starboard Main Engine high water temp alarm was not operable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 11 March 2021
Resolution: Starboard main engine high water alarm was repaired and tested satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 14 February 2019 Resolved
Weak link improper capacity for life floats.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2019
Resolved 25 February 2019
Resolution: Fitted life float with appropriate weak link.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019 Resolved
Anchor line wasted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2019
Resolved 25 February 2019
Resolution: Renewed anchor line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2018 Resolved
Port ring life buoy found cracked and degraded. Replace life buoy.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 24 July 2018 Resolved
Turnbuckle on starboard side rial course wasted. Replace as appropriate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 July 2018 Resolved
Dogs on Class 1 watertight doors found frozen and inoperable, light can be seen through door when secured. Repair/adjust as necessary to provide proper seal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 July 2018 Resolved
Valve for firestation 3 starboard deck aft is frozen and inoperable. Repair/replace as necessary.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 July 2018 Resolved
Firestation 1 has a quick disconnect fitting, the associated hose was found disconnected and to have a threaded fitting. Provide functional/matching fittings for firestation and hose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 July 2018 Resolved
Nav lights inoperable. Replace bulbs and prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 July 2018 Resolved
Five out of the six required red hand flares were founfd to be expired. Replace as necessary.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 July 2018 Resolved
EPIRB disposable hydrostatic release unit expired. Provide new release unit.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2018 Resolved
Ring Life Buoy floating waterlight found inoperable. Prove proper operation of floating waterlight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 9 July 2018 Resolved
Lagging in engine room removed and not replaced. Replace lagging as required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 9 July 2018 Resolved
Life floats require repair/paint by approved servicing facility.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 July 2018
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 July 2018 Resolved
Vessel could not provide current tide table. Provide up to date tide tables for operating area.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 July 2018 Resolved
Vessel could not provide proof of enrollment for crewmembers in drug and alcohol testing program.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 July 2018 Resolved
Refrigerator is not secured to prevent movement in heavy seas. Secure refrigerator as appropriate.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2018 Resolved
Found dead end wire for antenna ground. Remove/secure as appropriate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2018 Resolved
Dead end wire on light fixture in port side berthing. Remove or secure in proper junction box.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 July 2018 Resolved
Bilge pump system not operating properly. Prove proper operation of bilge system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 July 2018 Resolved
Valve/fitting found missing from overboard piping for galley/head sinks which would allow sink to discharge into bilge or seawater to enter through side shell opening. Replace as necessary.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2018 Resolved
Fire hose has a hole and is degraded. Replace fire hose.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 April 2017 Resolved
Provide proof of required first aid kit items IAW 46 CFR 184.710
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: New first aid kit on board in compliance with regulations.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 6 April 2017 Resolved
Replace expired batteries on life jacket lights. 46 CFR 180.75
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Expired batteries have been replaced on lifejackets.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 April 2017 Resolved
Replace expired battery on ring buoy light. 46 CFR 180.70
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: New battery was provided for ring buoy light.
Engineering › Steam System (auxiliary) › Lagging/Insulation
Issued 6 April 2017 Resolved
Reattach lagging on port engine IAW 46 CFR 182.425
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Lagging was reattached upon completion of maintenance.
Navigation › Piloting/Steering › Marine Charts
Issued 6 April 2017 Resolved
Update charts and pubs for area of operation. 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Current charts and pubs were provided.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 6 April 2017 Resolved
Properly secure refrigerator and oven to prevent movement in heavy weather. 46 CFR 184.220
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Locking devices were installed on oven and refrigerator.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 April 2017 Resolved
Provide two operable portable battery lights. 46 CFR 183.430
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Engine room portable light was restored to operation.
Engineering › Compressed Air System (control) › Compressor
Issued 6 April 2017 Resolved
Properly lash down portable air compressor. 46 CFR 176.800
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Air compressor was properly secured with lashings.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 6 April 2017 Resolved
Repair/replace distribution panel door. 46 CFR 183.330
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2017
Resolved 12 April 2017
Resolution: Suitable distribution panel door was installed as requested
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 6 April 2017 Resolved
Provide proof of supervisory DAPI training, 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Supervisory training was provided and documented for all persons in supervisory positions.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 April 2017 Resolved
Hard wire or remove engine heaters IAW 46 CFR 183.340.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Heaters were removed from the space.