FOUR C'S

FOUR C'S is a 1968 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1981, most recently in April 2025, along with 235 deficiencies and 1 operational control.

Records from 1981 to 2025. Most recent: inspection, 21 April 2025.

Built
1968
Last inspected
21 April 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH7891
Flag
UNITED STATES
367652660
Maury page id
psix-46085

Inspections, by type

…with no type recorded11
Years with a record 40 calendar years (1981–2025)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)73.7 ft × 17.9 ft × 8.4 ft
Registered tonnagegross 68 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · CROWN POINT, LA, UNITED STATES · built 1968
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Regulatory (Subpart C or D), Gross Ton
46 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH7891MMSI 367652660 · active · compulsorily equipped · granted 31 December 2024, expires 8 January 2035
WDC2292MMSI 366990690 · expired · compulsorily equipped · granted 16 November 2004, cancelled 17 January 2015
WCP3617MMSI not assigned · expired · compulsorily equipped · granted 13 December 1994, cancelled 12 February 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BULL RED Offshore Supply Vessel · MISLE 211747 · 31 January 2020 · activity 6904224

Inspection history · 64

21 April 2025 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8104130
27 January 2025 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8070278
15 March 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7879834
13 April 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7666001
22 March 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7655496
27 February 2023 Administrative Inspection · Drydock Extension
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7640519
17 May 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7453159
11 March 2021 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7154152
23 February 2021 COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7143040
26 January 2021 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7131076
26 June 2020 Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6987494
14 April 2020 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6939141
31 January 2020 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6904224
14 February 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6626143
9 July 2018 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6473584
28 March 2018 Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6380232
23 February 2017 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6093117
9 December 2015 COI Inspection · DAPI Audit · Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5778621
4 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4218477
30 December 2010 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3917985
30 July 2009 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3547349
23 July 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3540307
10 September 2008 Deficiency Check · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3320497
5 August 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3284992
30 May 2007 Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2940364
17 October 2006 Deficiency Check · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2802157
3 April 2006 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2613897
16 May 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2359433
12 May 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2355683
4 October 2004 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2213089
17 September 2004 Re-Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2198254
16 May 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1794754
16 May 2002 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1617558
5 July 2001 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 1521910
17 May 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393688
12 May 2000 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369668
28 July 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1111336
18 May 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400992
13 May 1998 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378381
7 May 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383557
17 May 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443704
22 May 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443587
19 May 1994 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358402
30 July 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1158631
16 July 1993 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422258
24 July 1992 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356154
15 April 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 74656
24 March 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1261979
6 September 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249521
15 January 1991 Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236331
10 January 1991 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919930
29 October 1990 COI Inspection · Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921842
27 September 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1213299
20 June 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1210840
8 July 1989 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1200802
9 November 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 893696
25 January 1988 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1017957
26 February 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318349
21 February 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994036
1 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979145
29 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987723
5 January 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969080
20 January 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965254
20 February 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965919

Deficiency record · 235

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 April 2025 Resolved
A self priming, power driven fire pump must be installed on each vessel: of more than 19.8 meters (65 feet) in length. Marine inspector observed fire main inoperable. 46 CFR 181.300(a)(iii)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: tested power driven fire pump. all sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 21 April 2025 Resolved
Marine employers must establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Marine Inspector observed Consortium enrollment expired. Vessel Employer shall ensure all crewmembers employed are enrolled in random chemical testing for dangerous drugs. 46 CFR 16.230
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: Vessel displayed proof of enrollment for all crew members. all sat.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 21 April 2025 Resolved
Licenses for ship stations in the maritime services will normally be issued for a term of ten years from the date of original issuance, or renewal. Marine Inspector observed FCC Station license expired. Vessel shall contact and FCC certified technician to renew listed certificate. 47 cfr 80.25
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: vessel had fcc tech onboard to issue new cert.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 April 2025 Resolved
At every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter. Marine Inspector observed excessive oil in the bilge and crewmembers actively pumping ashore. 46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: bilge was clean and clear with oil remove. all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 April 2025 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Marine Inspector was unable to test bilge pump suction due to defieicny number 4, vessel had excessive oil in engine room bilges. Vessel owner/operator shall ensure bilges are clean and clear to ensure bilge pumps are operational. 46 CFR 182.520(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: tested all bilge suction. all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 April 2025 Resolved
Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers. Marine Inspector observed fire servicing technician report missing and fire extinguisher tags indicated the expiration of the fire extinguishers were April 2025. Vessel owner/operator shall have annual inspection conducted prior to def check for remaining deficiencies listed below. 46 CFR 176.810 (b)(1)(i)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2025
Resolved 24 April 2025
Resolution: Vessel rep had fire fighting extinguishers serviced with proof of servicing. All sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 April 2025 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Marine inspector observed expiration date of April 2025. Vessel needs to replace prior to def check for remaining deficiencies listed below. 46 CFR 185.740(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2025
Resolved 24 April 2025
Resolution: new HRU was purchased and installed on EPIRB.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2024 Resolved
At each initial and subsequent inspection for certification of a vessel the owner or managing operator shall test operation of the means provided for pumping bilges. Marine Inspector observed failed test of fwd peak space and oily water in crew space bilge. Fix and test satisfactory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2024
Resolution: Marine Inspector attended vessel and watched satisfactory test of bilge suction system from all applicable spaces.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 May 2024 Resolved
At each inspection for certification and at every other vessel inspection all hazardous situations must be corrected. Marine Inspector observed bilge space under berthing to contain oily water. Clean out.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2024
Resolution: Vessel's crew pumped out and cleaned. Marine Inspector examined and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2024 Resolved
For each 21,000 U.S. gal or any flammable or combustible liquid being transported on board a vessel in a portable tank at least one fire hose fitted with an approved portable mechanical form nozzle with pick-up tube. Vessel Master self reported foam nozzle and pick-up tube was not working. Replace/repair.
Action required: 705 - Other - as specified
Resolved 24 May 2024
Resolution: Marine Inspector attended vessel and observed satisfactory test of eductor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 14 May 2024 Resolved
At each inspection for certification and at every other vessel inspection the owner or managing operator shall have ready for inspection all watertight closures in the deck and bulkheads. Engine room door does not have correct gasket and fore peak hatch has a ripped gasket. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 20 May 2024
Resolution: Vessel's crew replaced. Marine Inspector examined and found satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 May 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's anchor light is extinguished. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 20 May 2024
Resolution: Vessel's crew replaced. Marine Inspector examined and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 April 2024 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Marine Inspector observed expired firefighting servicing report. Have servicing done.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel rep. supplied servicing report. Marine Inspector reviewed and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 April 2024 Resolved
Portable extinguishers must be inspected and maintained IAW NFPA 10. Marine Inspector observed engine room fire extinguisher gauge to be in the red. Replace.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel rep. supplied new extinguisher. Marine Inspector inspected and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 2 April 2024 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Marine Inspector observed expired batteries in the water light attached to the life float. Replace.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel rep. supplied new battery. Marine Inspector inspected and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 April 2024 Resolved
Ladders provided to aid escape must be fixed unless able to be brought into immediate service. Escape ladder for the engine room to the deck not on board. Place on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel rep. supplied ladder. Marine Inspector inspected and found satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 April 2024 Resolved
At each inspection Marine Inspector may require a man overboard drill. Perform prior to operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel crew performed satisfactory man overboard drill.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 April 2024 Resolved
At each inspection Marine Inspector may require a man overboard drill. Perform prior to operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel crew performed satisfactory fire drill.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 April 2024 Resolved
At each inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected and in satisfactory condition. Marine Inspector observed a strong odor of fuel in the lazarette. Investigate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel crew cleaned bilge. Marine Inspector examined and found satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 April 2024 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high "EMERGENCY EXIT KEEP CLEAR." Marine Inspector observed the emergency escape in engine room not properly labeled. Label.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel crew labeled. Marine Inspector examined and found satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 April 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessels Captain self reported that the vessels mast head light was out. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel crew replaced. Marine Inspector examined and found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2024 Resolved
A suitable marine type strainer shall be fitted in the fuel supply line in the engine compartment. Marine Inspector observed missing metal bowl under the filter for the starboard main engine. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel crew replaced. Marine Inspector examined and found satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 April 2024 Resolved
Vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Marine Inspector observed a lack of current charts readily available. Have on board. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel crew procured. Marine Inspector examined and found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 March 2024 Resolved
The shutoff valve must be manually operable from the outside the compartment. Marine Inspector observed the shutoff valve corroded and unable to move. Repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Vessel rep. repaired. Marine Inspector inspected and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 March 2024 Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, or designated crew member. Marine Inspector observed last record to be in 2022.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel crew completed current months inspection. Marine Inspector examined and found satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 15 March 2024 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station must carry a radio operator who holds a marine radio operator permit. Marine Inspector was informed by Captain that they did not have it on them. Have on board. 47 CFR 80.159(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel master had onboard. Marine Inspector examined and found satisfactory.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 March 2024 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident shall comply with 46 CFR 4.06 regarding alcohol testing. Vessel doesn't have a means to test. Obtain an approved method to test for alcohol. 46 CFR 185.212
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Vessel crew procured. Marine Inspector examined and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 April 2023 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Engineroom bilge contained excessive water in bilge mixed with diesel fuel from recent fuel filter changes. Crew to pump bilge to an approved facility. 46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2023
Resolution: Bilge was dewatered.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2023 Resolved
All unfired pressure vessels must be installed to the satisfaction of the cognizant [name withheld] compressor and tank located in passenger compartment void was not secured in place. 46 CFR 182.330
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2023
Resolution: Secured in place.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 13 April 2023 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. Engine room over board bilge piping flex hose at side shell was damaged. 46 CFR 182.25-1 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2023
Resolution: Flex hose replaced.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 April 2023 Resolved
The fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Deck cap was seized. 46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2023
Resolution: Main deck cap protecting reach rod was freed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2023 Resolved
Exhaust gas must not leak from the piping or any connections. Starboard MDE outboard turbo to exhaust pipe was covered in soot indicating a leak. 46 CFR 182.430 (b).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2023
Resolution: Turbo clamp was tightend.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2023 Resolved
For each 21,000 U.S. gallons or part thereof of any Class 3 (flammable) or combustible liquid being transported on board a vessel in a portable tank there must be provided a fire hose fitted with an approved portable mechanical foam nozzle with pick-up tube. Vessel's pick up tube was inoperable. 49 CFR 176.315(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: The vessel's pick-up tube has been successfully restored to full operational status.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 13 April 2023 Resolved
Each light fixture must protect crew from electrical hazards. Two overhead light fixtures in accomodation spaces were missing covers and electrical j-box in head was missing an outlet cover. 46 CFR 183.200(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: light fixtures throughout have been fitted with appropriate covers, and the electrical box located in the head has been equipped with a secure outlet cover.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 April 2023 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Cargo deck hatch leading out of engine room was painted yellow, but needed stenciled. 46 CFR 185.606
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Inspected and labeled in accordance with safety regulations and industry standards. All exit points are now clearly marked with visible and durable signage indicating their use as means of escape.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 April 2023 Resolved
The master of the vessel shall ensure tha each EPIRB be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative and be logged. Vessel's log book did not show proof of EPIRB tests. 46 CFR 185.728(c).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Logbook has been thoroughly reviewed and updated as per the latest maintenance and inspection protocols. All relevant data entries, including test results have been recorded.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 April 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Chart provided was several years old showing no signs of being updated. 46 CFR 184.420(a)(1).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: New up to date charts were purchased and placed o/b
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 13 April 2023 Resolved
The master of a vessel shall have examined and tested the steering gear, signaling whistle, propulsion controls, and communication systems of the vessel prior to getting underway for a voyage, except that such examination and testing need not be conducted more than once in any 24 hour period. Master was not aware of required tests. 46 CFR 185.320.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Prior to conducting drills the Master was profficient in their duties
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 13 April 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted or made available to the crew and passengers. One set of instructions was faded and difficult to read. 46 CFR 185.516(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2024
Resolution: Instructions were posted and clearly visible
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 May 2022 Resolved
The hydrostatic release unit for the EPIRB is not marked with an expiration date. 46 CFR 185.740(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 24 May 2022
Resolution: New hydrostatic release for EPIRB installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2022 Resolved
Battery lid is missing. 46 CFR 183.05-20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 24 May 2022
Resolution: Replaced battery lid
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2022 Resolved
Main diesel engines do not have machinery guards. 46 CFR 177.35-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 24 May 2022
Resolution: Machinery guards installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2022 Resolved
F/O shut off valves on vessel were unable to open/close. 46 CFR 182.20-40 (3)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2022
Resolved 24 May 2022
Resolution: Deficiency rectified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2022 Resolved
Exhaust lagging is missing exposing hot pipes. 46 CFR 182.15-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 24 May 2022
Resolution: New lagging installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 May 2022 Resolved
Battery for light is expired on 02 life floats. 46 CFR 180.175(4)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2022
Resolved 24 May 2022
Resolution: Deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 17 May 2022 Resolved
01 ring buoy is unserviceable and needs to be replaced. 01 ring buoy cork needs to be repaired/replaced. 46 CFR 180.70
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2022
Resolved 24 May 2022
Resolution: Deficiency rectified
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 February 2021 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR. HAtch leading out of the engine room onto the cargo deck was not stenciled. 46 CFR 185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 11 March 2021
Resolution: Stenciling was applied to hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 February 2021 Resolved
A vessel of more than 65 feet in length must carry at least one rescue boat unless the cognizant OCMI determines that the vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. Rescue ladder when deployed was at an angle not capable of recovering a helpless person from the water. 46 CFR 180.210.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 11 March 2021
Resolution: Rescue platform was provided with stand off pipes to keep ladder in a vertical position while climbing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 February 2021 Resolved
Each vessel that relies on electricity to power vital loads must be arranged so that the loads can be energized from two sources of electricity. Fire pump could not be energized from the port generator. 46 CFR 183.310
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 11 March 2021
Resolution: Fire pump motor was causing an overloading condition on port generator when energized. Crew swapped out fire pump motor and tested satisfactory while 73 psi and fire pump.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 23 February 2021 Resolved
Gauges to indicate jacket water discharge temperature, must be provided for all propulsion engines installed in the vessel. Starboard Main Engine high water temp alarm was not operable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 11 March 2021
Resolution: Starboard main engine high water alarm was repaired and tested satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 14 February 2019 Resolved
Weak link improper capacity for life floats.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2019
Resolved 25 February 2019
Resolution: Fitted life float with appropriate weak link.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019 Resolved
Anchor line wasted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2019
Resolved 25 February 2019
Resolution: Renewed anchor line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2018 Resolved
Port ring life buoy found cracked and degraded. Replace life buoy.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 24 July 2018 Resolved
Turnbuckle on starboard side rial course wasted. Replace as appropriate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 July 2018 Resolved
Dogs on Class 1 watertight doors found frozen and inoperable, light can be seen through door when secured. Repair/adjust as necessary to provide proper seal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 July 2018 Resolved
Valve for firestation 3 starboard deck aft is frozen and inoperable. Repair/replace as necessary.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 July 2018 Resolved
Firestation 1 has a quick disconnect fitting, the associated hose was found disconnected and to have a threaded fitting. Provide functional/matching fittings for firestation and hose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 July 2018 Resolved
Nav lights inoperable. Replace bulbs and prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 July 2018 Resolved
Five out of the six required red hand flares were founfd to be expired. Replace as necessary.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 July 2018 Resolved
EPIRB disposable hydrostatic release unit expired. Provide new release unit.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2018 Resolved
Ring Life Buoy floating waterlight found inoperable. Prove proper operation of floating waterlight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 9 July 2018 Resolved
Lagging in engine room removed and not replaced. Replace lagging as required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 9 July 2018 Resolved
Life floats require repair/paint by approved servicing facility.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 July 2018
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 July 2018 Resolved
Vessel could not provide current tide table. Provide up to date tide tables for operating area.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 July 2018 Resolved
Vessel could not provide proof of enrollment for crewmembers in drug and alcohol testing program.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 July 2018 Resolved
Refrigerator is not secured to prevent movement in heavy seas. Secure refrigerator as appropriate.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2018 Resolved
Found dead end wire for antenna ground. Remove/secure as appropriate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2018 Resolved
Dead end wire on light fixture in port side berthing. Remove or secure in proper junction box.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 July 2018 Resolved
Bilge pump system not operating properly. Prove proper operation of bilge system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 July 2018 Resolved
Valve/fitting found missing from overboard piping for galley/head sinks which would allow sink to discharge into bilge or seawater to enter through side shell opening. Replace as necessary.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2018 Resolved
Fire hose has a hole and is degraded. Replace fire hose.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 April 2017 Resolved
Provide proof of required first aid kit items IAW 46 CFR 184.710
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: New first aid kit on board in compliance with regulations.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 6 April 2017 Resolved
Replace expired batteries on life jacket lights. 46 CFR 180.75
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Expired batteries have been replaced on lifejackets.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 April 2017 Resolved
Replace expired battery on ring buoy light. 46 CFR 180.70
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: New battery was provided for ring buoy light.
Engineering › Steam System (auxiliary) › Lagging/Insulation
Issued 6 April 2017 Resolved
Reattach lagging on port engine IAW 46 CFR 182.425
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Lagging was reattached upon completion of maintenance.
Navigation › Piloting/Steering › Marine Charts
Issued 6 April 2017 Resolved
Update charts and pubs for area of operation. 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Current charts and pubs were provided.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 6 April 2017 Resolved
Properly secure refrigerator and oven to prevent movement in heavy weather. 46 CFR 184.220
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Locking devices were installed on oven and refrigerator.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 April 2017 Resolved
Provide two operable portable battery lights. 46 CFR 183.430
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Engine room portable light was restored to operation.
Engineering › Compressed Air System (control) › Compressor
Issued 6 April 2017 Resolved
Properly lash down portable air compressor. 46 CFR 176.800
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Air compressor was properly secured with lashings.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 6 April 2017 Resolved
Repair/replace distribution panel door. 46 CFR 183.330
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2017
Resolved 12 April 2017
Resolution: Suitable distribution panel door was installed as requested
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 6 April 2017 Resolved
Provide proof of supervisory DAPI training, 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Supervisory training was provided and documented for all persons in supervisory positions.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 April 2017 Resolved
Hard wire or remove engine heaters IAW 46 CFR 183.340.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 12 April 2017
Resolution: Heaters were removed from the space.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 January 2016 Resolved
Drug and Alcohol Consortium letter expired. Update letter IAW 46 CFR 16.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2016
Resolved 28 January 2016
Resolution: Received e-mailed copy of an updated/current Drug and Alcohol Consortium letter.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 28 January 2016 Resolved
FCC Safety Radio Certificate expired. Update IAW 47 CFR 80.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2016
Resolved 29 January 2016
Resolution: New FCC Radio Certificates were obtained by the vessel.
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 20 January 2016 Resolved
Starter on the auxiliary power generator inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2016
Resolved 28 January 2016
Resolution: Generator starter was replaced.
Operations/Management › Drills/Instruction › Fire
Issued 20 January 2016 Resolved
Vessel unable to get underway and no drills were performed/witnessed
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2016
Resolved 28 January 2016
Resolution: Got vessel underway and conducted satisfactory fire and man-overboard drills.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 January 2016 Resolved
Battery in pilot house not mounted properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: Battery was mounted/secured.
Electrical › Electric Generation Source (service) › Generator
Issued 20 January 2016 Resolved
Inverter in pilot house smoking and inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2016
Resolved 28 January 2016
Resolution: Inverter was replaced and appeared to be operating properly.
Communications › Radio Communications › VHF Radiotelephone
Issued 20 January 2016 Resolved
VHF radio inop.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: VHF radio tested and appeared to be operating satisfactory.
Engineering › Bilge Water Management System › Not Operational
Issued 20 January 2016 Resolved
High-water level alarm inop.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: Alarm tested and appeared to operate properly.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 20 January 2016 Resolved
Operating station had no mounted flashlight.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: Operable flashlight / portable light was in place at the operating station.
Electrical › Electric Supply System (service) › Battery Charger
Issued 20 January 2016 Resolved
Voltmeter on 5 amp battery charger inop.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: New voltmeter was installed and appeared to be operating satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 January 2016 Resolved
Dead-ended wires found in port bunk room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: Wires were capped.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 20 January 2016 Resolved
Both fuel vent pipes were lacking mesh installation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: Mesh screens were installed.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (air intake)
Issued 20 January 2016 Resolved
Engine room vents on deck do not close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: All vents were made to operate and appeared satisfactory.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 January 2016 Resolved
Lifeline on buoy is incorrect type of line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: Satisfactory life-line was obtained and attached to buoy.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 January 2016 Resolved
Lifeline length of buoy with light attached was longer than 3-6 feet in length.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: Lanyard for buoy light was shortened to an acceptable length.
Engineering › Lubricating Oil Service System › Gauge
Issued 20 January 2016 Resolved
Both gauges on both engines inop. 46 CFR 182. 15-5 (Old "T")
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: New gauges were installed and appeared to operate satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 December 2010 Resolved
Dead end wire in engine room stbd side - remove wire or cap and secure inside a junction box.
Due 5 January 2011
Resolved 5 January 2011
Resolution: Wire secured in junction box
Lifesaving › Hand Flares › Expired
Issued 30 December 2010 Resolved
Replace six red day/night flares. Expired Nov 2010
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2011
Resolved 5 January 2011
Resolution: Replaced flares
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 30 December 2010 Resolved
Refrigerator doors need a securing latch installed
Action required: 705 - Other - as specified
Due 3 February 2011
Resolved 5 January 2011
Resolution: Owner installed Velcro securing straps
Fire Fighting › Firemans Outfit › Axe
Issued 30 December 2010 Resolved
No fire axe on board
Due 5 January 2011
Resolved 5 January 2011
Resolution: Installed new fire axe
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 30 December 2010 Resolved
Vessel name faded and no longer readable on all three life rings
Action required: 705 - Other - as specified
Due 3 February 2011
Resolved 5 January 2011
Resolution: Installed new vinyl lettering on life rings
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 December 2010 Resolved
Fwd mast light not working
Action required: 705 - Other - as specified
Due 5 January 2011
Resolved 5 January 2011
Resolution: Replaced bulb
Operations/Management › Passenger Operations › Safety Orientation
Issued 23 July 2009 Resolved
Provide a crew and passenger list asp per 46CFR 185.502
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: A crew and passenger list was provide.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 July 2009 Resolved
Provide updated charts for the area being navigated as per 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: Updated charts were provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 July 2009 Resolved
Prove proper operations of the port navigation light as per 46 CFR 183.420.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2009
Resolved 30 July 2009
Resolution: The port navigation light was tested and proven.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 23 July 2009 Resolved
Prove proper operation of the ships horn as per 33 CFR 86.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: The ships horn was tested with satisfactory results.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 23 July 2009 Resolved
Provide two additional hand orange smoke distress signals for a total of six as per 46 CFR 180.68.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2009
Resolved 30 July 2009
Resolution: The vessel have onboard a total of six smoke distress signals.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 23 July 2009 Resolved
Make repairs to the soft patch in the overhead of the engine room to secure the leak.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 4 August 2009
Resolution: Repairs were made in way of overhead in engine room and were found to be satisfactory upon inspection.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 23 July 2009 Resolved
Provide and install lagging for the exhaust piping between the exhaust manifold and the turbo on the starboard outboard engine as per 46 CFR 177.970.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: The lagging was properly installed on the exhaust of the starboard engine.
Engineering › Diesel Engine (propulsion-direct drive) › Camshaft
Issued 23 July 2009 Resolved
Provide and install guards over rotating machinery on the starboard main engine as per 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 4 August 2009
Resolution: Guards were installed over rotating machinery on STBD engine as required and found to satisfactorily meet this requirement.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 23 July 2009 Resolved
Make repairs to the port and starboard main engines and the generator to secure the excessive lube oil leaks as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 4 August 2009
Resolution: Repairs were made to secure the excessive lube oil leaks as required and upon inspection were found satisfactory.
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 July 2009 Resolved
Provide and install hose clamps to meet the double hose clamp requirement throughout the engine room as per 46 CFR 182.410 (d).
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: Hose clamps were provided and installed as needed in the engine room.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 23 July 2009 Resolved
Provide and install a cover for the ammeter on the battery charge on the starboard side.
Due 23 August 2009
Resolved 30 July 2009
Resolution: A new battery charger was properly install with ammeter.
Electrical › Electrical Distribution System (service) › Cable
Issued 23 July 2009 Resolved
Remove the excessive electrical cables to avoid sharp bens in the cable.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: The electrical cables were properly installed.
Construction/Loadline › Hull › Hull Plating
Issued 23 July 2009 Resolved
Provide a written repair proposal for the fractures in the hull plate and welds in way of the generator exhaust on the port side.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 4 August 2009
Resolution: Area was cropped and renewed with 28 X 24 inch insert and NDT was dye penetrant test with satisfactory results.
Electrical › Electrical Distribution System (service) › Cable
Issued 23 July 2009 Resolved
Make proper repairs or replace the electrical cable leading from the generator to the main distribution panel and properly install.
Due 23 August 2009
Resolved 30 July 2009
Resolution: The electric cable was renewed and properly installed.
Engineering › Bilge Water Management System › Not Operational
Issued 23 July 2009 Resolved
Remove all oily debris in the bilge of the midbody compartment and engine room and clean.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: The bilges were cleaned.
Fire Fighting › Fire Main › Condition
Issued 23 July 2009 Resolved
Prove the integrity of the piping for the fire main.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: The deteriorated piping in the fire main was replaced and tested with satisfactory results.
Construction/Loadline › Penetrations › Gasket
Issued 23 July 2009 Resolved
Provide and install a gasket for the water-tight hatch for the forepeak.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: A new gasket was installed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 23 July 2009 Resolved
Provide and install new batteries for the water lights for the life floats.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: New batteries were installed in the water lights.
Accommodation/Occupational Safety › Messroom › Location
Issued 23 July 2009 Resolved
Properly secure the refrigerator in the galley.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: The refrigerator was properly secured.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 23 July 2009 Resolved
Properly secure the A/C unit on the 01 deck.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: The A/C unit was properly secured.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 July 2009 Resolved
Properly stencil the vessel's name and renew the retro reflective tape on the ring buoy.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: The ring buoy was properly stenciled with the vessel''s name and the retro tape was replaced.
Lifesaving › Lifefloat › Markings
Issued 23 July 2009 Resolved
Properly stencil the vessel's name on the life float.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: The life floats were renewed and properly stenciled.
Construction/Loadline › Penetrations › Gasket
Issued 23 July 2009 Resolved
Renew the gasket in the water-tight door leaking into the passenger compartment.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: The gasket was renewed.
Lifesaving › Lifefloat › Serviceable
Issued 23 July 2009 Resolved
Have both 12 man life floats serviced by an authorized service facility.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2009
Resolved 30 July 2009
Resolution: The life floats were renewed and properly stenciled.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 23 July 2009 Resolved
Properly stencil life jackets with the vessel's name.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: The life jackets was stenciled with the vessel''s name.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 23 July 2009 Resolved
Provide and install retro tape on the one life jacket as discussed.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: The retro tape was replaced on the life jacket.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 23 July 2009 Resolved
Replace the one life jacket that’s painted black or repaint international orange.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 30 July 2009
Resolution: The life jacket was replaced.
Engineering › Steering Gear System › Rudder
Issued 10 September 2008 Resolved
Remove rudder for inspection. Renew rudder as original.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 15 September 2008
Resolution: Repaired rudder to original specifications
Engineering › Sea-water System (primary cooling) › Valve
Issued 10 September 2008 Resolved
Provide sea valves for inspection.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 15 September 2008
Resolution: Sea valves in working condition. One ball-type valve replaced with new gate valve.
Stability › Watertight Integrity › General
Issued 10 September 2008 Resolved
Remove water from engine room bilge for inspection of keel
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 15 September 2008
Resolution: Water removed to show keel. No deficiencies noted on keel and interior bottom plating.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 September 2008 Resolved
Fully support battery cables at highest level possible above bilge.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 15 September 2008
Stability › Weathertight Integrity › General
Issued 10 September 2008 Resolved
Provide tethering for watertight hatches on cargo deck.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 15 September 2008
Resolution: Chains provided as tethering for hatches.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 10 September 2008 Resolved
Renew aft watertight hatch on lazarette.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 17 September 2008
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 10 September 2008 Resolved
Provide proper anchor line
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 15 September 2008
Resolution: Anchor line provided
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 10 September 2008 Resolved
Provide flame screen for sewage tank vent on stbd side of house.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 15 September 2008
Resolution: Flame screens installed
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 10 September 2008 Resolved
Repair or replace port propeller
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 17 September 2008
Resolution: Port propeller replaced.
Engineering › Steering Gear System › Rudder
Issued 10 September 2008 Resolved
Prove proper operation of steering system.
Action required: 705 - Other - as specified
Due 15 October 2008
Resolved 17 September 2008
Stability › Weathertight Integrity › General
Issued 10 September 2008 Resolved
Provide venting for lazarette
Action required: 705 - Other - as specified
Due 15 October 2008
Resolved 17 September 2008
Construction/Loadline › Hull › Weld
Issued 10 September 2008 Resolved
Repair welds on starboard rub rail
Action required: 705 - Other - as specified
Due 15 October 2008
Resolved 17 September 2008
Communications › Radio Communications › EPIRB
Issued 5 August 2008 Resolved
Replace EPIRB hydrostatic release per 46 CFR 180.64
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Provided new hydrostatic release
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 August 2008 Resolved
Ensure proper publications are onboard as per 46 CFR 184.420
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Provided new publications
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 August 2008 Resolved
Ensure lifefloats have attached proper light as per 46 CFR 180.175 (f)(4)
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Light attached and operational
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 5 August 2008 Resolved
Ensure all PFD lifejackets have attached proper light as per 46 CFR 180.75
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Provided new chem lights for all PFDs
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 August 2008 Resolved
Ensure each life ringbuoy is properly marked with vessel name as per 46 CFR 185.604
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Stenciled all lifebuoys
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 August 2008 Resolved
Ensure starboard navigation light and stern light are installed as per 46 CFR 183.420
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Corrected arc of visibility for stern and stbd lights
Engineering › Diesel Engine (propulsion-electric) › Piping (air intake)
Issued 5 August 2008 Resolved
Repair oil leak coming from breathers on port and starboard main engines.
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Repaired leak in breathers
Engineering › Lubricating Oil Service System › Piping
Issued 5 August 2008 Resolved
Repair oil leak on starboard main engine at bottom of gearbox.
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Sealed leaking gearbox.
Engineering › Fuel Oil Service System › Filter
Issued 5 August 2008 Resolved
Place cap on cockvalve for flange bowl for port fuel filter.
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Provided new cap.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 August 2008 Resolved
Replace all expired medication in first aid kit.
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Provided new complete first aid kit.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 August 2008 Resolved
Prove proper operation of emergency lighting as per 46 CFR 183.432
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Rewired some lights to correct issues.
Lifesaving › Hand Flares › Not on Board
Issued 5 August 2008 Resolved
Replace 6 missing orange flares as per 46 CFR 180.68
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Provided 6 new orange flares
Engineering › Steering Gear System › Fastener
Issued 5 August 2008 Resolved
Tighten bolts on hydraulic ram for steering system in lazarette.
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Tightened existing nuts and bolts in steering system
Communications › Alarms/Indicators › High Water Alarm
Issued 5 August 2008 Resolved
Prove proper operation of high water-level alarm in bilge of lazarette.
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Proved proper operation of alarm
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 August 2008 Resolved
Replace missing chains across stern in way of railing.
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 6 August 2008
Resolution: Provided new chains across stern.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 June 2007 Resolved
Properly mount the light fixtures in the lazarette as per 46 CFR 183.410.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 8 June 2007
Resolution: Properly mounted the light fixtures in the lazarette as per 46 CFR 183.410.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 June 2007 Resolved
Properly install the lighting fixtures with guards in the lazarette as required by 46 CFR 183.410
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 8 June 2007
Resolution: Properly installed the lighting fixtures with guards in the lazarette
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 6 June 2007 Resolved
Provide a repair proposal to make proper repairs to the leak on the fuel supply line to the local OCMI prior to the vessel being moved as required by 46 CFR 176.700
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 8 June 2007
Resolution: Provided a repair proposal to make proper repairs to the leak on the fuel supply line
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 June 2007 Resolved
Provide guards over rotating machinery in the engine room in accordance with 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Provided guards over rotating machinery in the engine room.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 5 June 2007 Resolved
Properly mount the door on the distribution panel in the engine room in accordance with 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Properly mounted the door on the distribution panel in the engine room.
Electrical › Electric Generation Source (service) › Generator
Issued 5 June 2007 Resolved
Clean the windings on the generator by removing all caked oil in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Cleaned the windings on the generator by removing all caked oil.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 5 June 2007 Resolved
Secure the excessive leaking on the port shaft packing gland in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Stopped excessive leaking on the port shaft.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 June 2007 Resolved
Clean the bilges by removing all trash and excessive dirt, oil, and water from the bilges in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Cleaned the bilges by removing all trach and excessive dirt, oil, and water.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 June 2007 Resolved
Properly insulate the exhaust piping by repairing/rewrapping the lagging in accordance with 46 CFR 182.430.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Properly insulated the exhuast piping.
Engineering › Fuel Oil Service System › Filter
Issued 5 June 2007 Resolved
Properly connect the fuel line to the fuel filter for the starboard main engine in accordance with 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Properly connected the fuel line to the fuel filter for the starboard main engine.
Electrical › Electric Generation Source (service) › Generator
Issued 5 June 2007 Resolved
Secure/repair the excessive oil leaks on the generator in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Repaired the excessive oil leaks on the generator.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 June 2007 Resolved
Prove proper operation of the emergency lighting in accordance with 46 CFR 183.432.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Proved proper operation of the emergency lighting.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 5 June 2007 Resolved
Provide a proper lifejacket donning placard for the type of lifejackets on board in accordance with 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Provided the proper lifejacket donning plazard for the type of lifejackets on board.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 5 June 2007 Resolved
Properly mount the electrical plug for the refrigerator in the galley in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Properly mounted the electrical plug for the refrigerator in the galley.
Electrical › Lighting (service) › Switch
Issued 5 June 2007 Resolved
Prove proper operation of the light switch in the head in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Proved proper operation of the light switch in the head.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 June 2007 Resolved
Provide rails for the stern to meet the requirements of 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Provided rails for the stern.
Engineering › Fuel Oil Service System › Valve
Issued 5 June 2007 Resolved
Properly label the emergency fuel shut-off for the port fuel tank in accordance with 46 CFR 185.608.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Properly labeled the emergency fuel shut-off for the port fuel tank.
Engineering › Fuel Oil Service System › Valve
Issued 5 June 2007 Resolved
Prove proper operation of the emergency fuel shut-offs in accordance with 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Proved proper operation of the emergency fuel shut-offs.
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 June 2007 Resolved
Properly mount the battery under the console at the operating station in accordance with 46 CFR 183.350.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Properly mounted the battery under the console at the operating station.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2007 Resolved
Remove the dead end wires in the console in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Removed the dead end wires in the console.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 June 2007 Resolved
Properly mount the power converter in the console at the operating station in accordance with 46 CFR 183.200.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Properly mounted the power converter in the console at the operating station.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2007 Resolved
Properly splice the wires in the console in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Propely spliced the wires in the console.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 June 2007 Resolved
Properly mount the electrical plug receptacle in the pilothouse in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Properly mounted the electrical plug receptacle in the pilothouse.
Engineering › Steering Gear System › Hydraulic Hose
Issued 5 June 2007 Resolved
Make repairs to the leaking hydraulic steering lines at the operating station in accordance with 46 CFR 182.610.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Made repairs to the leaking hydraulic steering lines at the operating station.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 5 June 2007 Resolved
Make repairs to the hole in the forward bulkhead of the console to prevent the ingress of water in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Made repairs to the hole in the forward bulkhead of the console to prevent the ingress of water.
Engineering › Fuel Oil Service System › Filter
Issued 5 June 2007 Resolved
Remove the pet cock from the port fuel strainer in accordance with 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Removed the pet cock from the port fuel strainer.
Engineering › Bilge Water Management System › Interface Detector
Issued 5 June 2007 Resolved
Prove proper operation of the bilge high level alarm in the lazarette in accordance with 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Proved proper operation of the bilge high level alarm in the lazarette.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 5 June 2007 Resolved
Prove proper operation of the main engines in accordance with 46 CFR 182.200.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Proved proper operation of the main engines.
Engineering › Steering Gear System › Hand Pump
Issued 5 June 2007 Resolved
Prove proper operation of the steering system in accordance with 46 CFR 182.610.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Proved proper operation of the steering system.
Fire Fighting › Fire Pumps › Pressure
Issued 5 June 2007 Resolved
Prove proper operation of the fire pump in accordance with 46 CFR 181.300.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 8 June 2007
Resolution: Proved proper operation of the fire pump.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 June 2007 Resolved
Provide and post an emergency broadcast placard in accordance with 46 CFR 184.506.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Provided and posted an emergency broadcast placard.
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 June 2007 Resolved
Conduct fire, abandon ship, and man overboard drills in accordance with 46 CFR 185.520. and 185.524.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 19 June 2007
Resolution: Conducted fire, abandon ship, and man overboard drills.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 June 2007 Resolved
Remove excess fuel from the bilge in the lazarette and make ready for inspection in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 8 June 2007
Resolution: Removed the excess fuel from the bilge in the lazarette and made ready for inspection.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 3 April 2006 Resolved
Provide FCC marine radio operator's permit as required by 47 CFR.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 5 April 2006
Resolution: FCC marine radio operator''s permit was provided.
Operations/Management › Pollution › Control of Garbage
Issued 3 April 2006 Resolved
Post waste management plan in accordance with 33 CFR 151.57.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 5 April 2006
Resolution: Waste management plan posted.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 April 2006 Resolved
Captain and deckhand need to provide proof of enrolment in a drug program as required by 46 CFR part 16.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2006
Resolved 5 April 2006
Resolution: Drug cards were provided.
Operations/Management › Drills/Instruction › Not Conducted
Issued 3 April 2006 Resolved
Provide proof of consistent crew training as required by 46 CFR 185.420.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 5 April 2006
Resolution: Log book and logged training was provided.
Documentation › Logs/Records › Logbook (official)
Issued 3 April 2006 Resolved
Provide life saving equipment maintenance records (EPRIB logbook) as required by 46 CFR 185.702.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 5 April 2006
Resolution: Log book was provided.
Communications › Audible Communications › SPD (Other)
Issued 3 April 2006 Resolved
Provide public address system as required by 46 CFR 184.610.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 5 April 2006
Resolution: Public address system installed.
Fire Fighting › Fire Hoses › Connections
Issued 3 April 2006 Resolved
Attach fire hoses to hydrants as required by 46 CFR 181.320.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 3 April 2006
Resolution: All fire hoses were attached to hydrants.
Fire Fighting › Fire Main › Condition
Issued 3 April 2006 Resolved
Renew or replace leaking piping in way of the forward fire station #1 as required by 46 CFR 181.310.
Action required: 705 - Other - as specified
Due 4 May 2006
Resolved 5 April 2006
Resolution: Leaking piping was replaced.
Fire Fighting › Fire Hydrants › Condition
Issued 3 April 2006 Resolved
Remove the label for the non-existent fire station #3 in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 5 April 2006
Resolution: Label was removed.
Engineering › Steering Gear System › Ram
Issued 3 April 2006 Resolved
Prove operation of main steering system as per 46 CFR 182.610.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2006
Resolved 5 April 2006
Resolution: Steering operated satisfactorily.
Fire Fighting › Ventilation Systems › Ducts
Issued 3 April 2006 Resolved
Renew ventilation closure devices on all vents as required by 46 CFR 182.465.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 5 April 2006
Resolution: All ventilation closure devices were repaired.
Electrical › Electric Generation Source (service) › Panelboard
Issued 3 April 2006 Resolved
Renew ammeter for independent generator as per 46 CFR 183.322.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 17 October 2006
Resolution: Provided new ammeter.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 3 April 2006 Resolved
Install a proper handle on starboard raw water intake valve as per 46 CFR 179.350.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 17 October 2006
Resolution: Installed new valve.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 3 April 2006 Resolved
Renew/repair door to distribution panel as per 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 5 April 2006
Resolution: Door was replaced.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 3 April 2006 Resolved
Provide labels for circuits in main distribution panels as per 46 CFR 183.05-15.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 5 April 2006
Resolution: Labels were provided.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 3 April 2006 Resolved
Provide a non-conductive mat covering where you stand when operating the switchboard as required by 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 5 April 2006
Resolution: A non-conductive mat was installed.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 12 May 2005 Resolved
During annual Re-inspection vessel was found to be operating outside its Certification of Inspection, where-in the required number of Deckhands was two (2), the vessel was operating with only one (1). Vessel has been operating in said condition for more than 6 months as shown by vessel logs.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 2 June 2005
Resolution: 2 Deckhands provided.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 12 May 2005 Resolved
Make Rescue Platform deployable from the Rescue Zone both Port and Stbd sides.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 2 June 2005
Resolution: Rescue Platform deployable form both sides.
Engineering › Fuel Oil Service System › Valve
Issued 12 May 2005 Resolved
Make repairs to Fuel Oil remote valves and show proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 2 June 2005
Resolution: Repaired valves, and tested operation with satisfactory results.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 12 May 2005 Resolved
Show proper operation of Emergency Lighting prior to sailing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 2 June 2005
Resolution: Tested Emergency Lighting with satisfactory results.
Stability › Watertight Integrity › General
Issued 12 May 2005 Resolved
Make repairs to and renew gaskets and adjust as necessary all Water and Weather Tight doors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 2 June 2005
Resolution: Completed all repairs and tested closures with satisfactory results.
Fire Fighting › Fire Pumps › Capacity
Issued 12 May 2005 Resolved
Show proper operation of Fire Pump.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 2 June 2005
Resolution: Tested Fire Pump operation with satisfactory results.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 September 2004 Resolved
Vessel was past due on Hull exam, which should have taken place prior to or on 13 May 2004.
Action required: 705 - Other - as specified
Resolved 13 October 2004
Resolution: Conducted drydock exam
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 September 2004 Resolved
Vessel operated over 90 days past it's annual inspection date of 17 May 04.
Action required: 705 - Other - as specified
Resolved 13 October 2004
Resolution: Conducted RIN
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 September 2004 Resolved
Vessel operated over 90 days past it's COI date with embarked passengers and many major deficiencies as noted in the subsequent inspection.
Action required: 705 - Other - as specified
Resolved 13 October 2004
Resolution: Conducted RIN
Fire Fighting › Fire Pumps › Arrangement
Issued 17 September 2004 Resolved
Not present.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2004
Resolution: Demonstrated proper operation of fire pump.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 17 September 2004 Resolved
Demonstrate proper operation of both main engines prior to sailing..
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2004
Resolved 8 October 2004
Resolution: Demonstrated proper operation.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 17 September 2004 Resolved
Repair fuel oil leak on generator prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2004
Resolved 8 October 2004
Resolution: RReapired f/o leak
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 17 September 2004 Resolved
Demonstrate proper operation of steering system prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2004
Resolved 8 October 2004
Resolution: Demonstated proper operation of steering system.
Construction/Loadline › Penetrations › Gasket
Issued 17 September 2004 Resolved
Repair leaks on main deck engine room access hatches prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2004
Resolved 13 October 2004
Resolution: Repaired hatches
Lifesaving › Buoyant Apparatus
Issued 16 May 2002 Resolved
WEAK LINK NOT SUFFICIENT FOR AMOUNT OF LIFEFLOATS CARRIED. LEGACY COMPONENT DESC: WEAK LINK
Action required: 705 - Other - as specified
Due 16 May 2002
Resolved 16 May 2002
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 May 2002 Resolved
CERTIFICATE OF DOCUMENTATION NOT CARRIED ON BOARD VESSEL.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2002
Resolved 16 May 2002
Documentation › Markings/Placards
Issued 16 May 2002 Resolved
NO LIFEJACKET DONNING PLACARD POSTED. LEGACY COMPONENT DESC: LIFEJACKET DONNING
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2002
Resolved 16 May 2002
Engineering › Diesel Engine (auxiliary)
Issued 16 May 2002 Resolved
MISSING FLYWHEEL GUARD ON GENERATOR LEGACY COMPONENT DESC: FLYWHEEL GUARD
Due 16 May 2002
Resolved 16 May 2002
Electrical › Electric Supply System (service) › Cable
Issued 16 May 2002 Resolved
ENGINE ROOM BILGE ALARMS INOPERABLE.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2002
Resolved 16 May 2002
Electrical › Electric Supply System (service) › Battery Charger
Issued 16 May 2002 Resolved
AMMETER ON STARBOARD BATTERY CHARGER INOPERABLE.
Due 16 May 2002
Resolved 16 May 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 16 May 2002 Resolved
NO RANGE GUARD INSTALLED. LEGACY COMPONENT DESC: RANGE GUARD
Due 16 May 2002
Resolved 16 May 2002
Fire Fighting › Fire Main › Condition
Issued 16 May 2002 Resolved
FIREMAIN RISER IN ENGINEROOM TO STARBOARD FIRE HOSE DECK VALVE CRACKED AND LEAKING WATER INTO ENGINEROOM BILGES.
Action required: 705 - Other - as specified
Due 16 May 2002
Resolved 16 May 2002
Construction/Loadline
Issued 18 May 1999 Resolved
PROVIDE BILGE HIGH LEVEL ALARM FOR RUDDER ROOM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Lifesaving
Issued 18 May 1999 Resolved
PROVIDE RESCUE PLATFORM.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Fire Fighting
Issued 16 July 1993 Resolved
REPLACE FLOOR BRACKET DRY CHEMICAL FIRE EXTINGISHER STATION #1.
Condition: Unknown
Due 30 July 1993
Resolved 26 August 1993
Documentation
Issued 16 July 1993 Resolved
PROVIDE ON BOARD ORIGINAL CERTIFICATE OF DOCUMENTATION THAT IS CURRENT.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Navigation
Issued 16 July 1993 Resolved
REPAIR RADAR POWER SUPPLY CONNECTOR.
Condition: Unknown
Due 30 July 1993
Resolved 26 August 1993
Construction/Loadline
Issued 10 January 1991 Resolved
MAKE PERNMENT REPAIR TO DAMAGES IN WAY OF FORE PECK TANK (PORT SIDE OF STEMBAR SET IN AFFECTING #5AND #6 LONGITUDINAL UP TO 4 FT AFT FROM STEM BARAND STARBOARD SIDE 6" HOLED APPROXIMATELY 6" LONG AND #6 OR #5 LONGITUDINALBOND. REPAIR MUST BE COMPLETED PRIOR TO PLACING VESSEL BACK IN OPERATION.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.