CHICAGO LEGEND is a 1997 passenger vessel (inspected). The Coast Guard has recorded 48 inspections since 1997, most recently in June 2026, along with 78 deficiencies and 1 casualty investigation in 2023.
Records from 1997 to 2026. Most recent: inspection, 15 June 2026.
- Built
- 1997
- Last inspected
- 15 June 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 78 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2023
Identity
1056904
WDH9604
460968
Flag
UNITED STATES
367669730
Maury page id
psix-460968
Inspections, by type
…with no type recorded2
Years with a record
24 calendar years (1997–2026)
The 48 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)64.0 ft × 14.5 ft × 5.8 ft
Registered tonnagegross 36 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAMERICAN MARINE LTD · MORA, MN, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 5 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Simplified, Gross Ton
28 - Simplified, Net Ton
28 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDH9604MMSI 367669730 · active · compulsorily equipped · granted 21 February 2025, expires 30 April 2035
WCX7526MMSI not assigned · expired · compulsorily equipped · granted 18 September 1997, cancelled 24 November 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 48
15 June 2026
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8405573
17 April 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8351200
12 November 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8267859
2 July 2025
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8173341
12 June 2025
COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8157587
2 October 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8013027
17 September 2024
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8003849
14 March 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7879225
12 September 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7790013
18 July 2023
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7802922
22 September 2022
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7564103
12 September 2022
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7556832
27 September 2021
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7321405
16 September 2021
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7312868
16 April 2021
Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7178054
19 October 2020
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7079825
19 June 2020
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6977517
19 September 2019
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6839753
22 August 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6519882
18 August 2017
DAPI Audit · Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6247152
29 September 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6012394
8 September 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5998419
1 August 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5960548
23 May 2016
Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5884640
6 October 2014
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4999931
21 September 2011
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4151137
6 August 2008
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3291018
6 July 2007
Simplified Stability Test
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2985951
14 June 2007
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2965863
30 May 2007
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2945106
21 July 2005
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2432983
15 October 2004
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2221388
2 September 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2170476
10 September 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1901727
28 August 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1867124
8 January 2003
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1719455
19 July 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1623282
19 September 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1074810
21 August 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1431089
8 January 2001
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1057722
11 July 2000
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1406866
2 July 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1468518
18 February 1999
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1393096
2 July 1998
Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1469529
25 September 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 785332
12 September 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 776480
12 August 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1455513
11 July 1997
Initial Certification · Hull Examination · Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1371929
Deficiency record · 78
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2026
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. While underway with passengers the PORT prop and shaft be came entangled with a line. The vessel is not authorized to operate passengers until cleared by the local OCMI.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 21 April 2026
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. There are 04 broken welds on the handrails on the aft deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2025
Resolved
Ring Buoy must be equipped with 60 feet of 5/16 diameter floating line. Line was only approx 30 feet in length.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 June 2025
Resolved
Provide onboard current, corrected charts. Charts onboard were dated 2009 or install a chart plotter meeting RTCM standards IAW NVIC 01-16.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 12 June 2025
Resolved
Replace all broken outlets throughout the vessel. Ground prong area's of where found broken away.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2025
Resolved
Remove Dead End wire and replace broken starboard battery charger breaker middle void space.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 June 2025
Resolved
Port Red navigaiton light is extinguished. Prove proper operation before operating vessel at night or in low visibility.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 September 2024
Resolved
Vessels Ring Buoy light would not function and upon further inspection had a battery that was expired as of March 2015. No record of inspections could be produced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 September 2024
Resolved
Vessel had a loss of propulsion on or about 24 August 2024 when a line fouled the port shaft and propeller and caused the engine to shutdown. Master cleared by diving on vessel after passengers disembarked by taking vessel out in Lake Michigan on one screw transiting the Chicago River and through the Chicago Lock. Advised master of requirements of reporting casualties.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 September 2024
Resolved
Portable fire extinguishers in addition to annual inspection must be checked monthly and recorded. Vessels master was not inspecting extinguishers monthly. Instructed master and deckhand on requirements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 September 2024
Resolved
Port R/W suction valve is leaking at the threads, repair leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 September 2024
Resolved
Port shaft was observed excessively leaking. prove proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 September 2024
Resolved
PFD's carried on addition to Type I's must be approved under 46 CFR 160.77 and properly maintained per manufacturers requirements. Additionally work vests must be approved under 46 CFR 160.033.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2024
Resolved
Electrical outlets in the port aft salon need repaired. 1 has cover creacked and 1 has recpticle cracked.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 September 2023
Resolved
Upon review of the construction of the vessel It has been determined that the Machinery space boundaries where not lined with noncombustible panels or insulation approved in accordance with 46 CFR 164.009 in Subchapter Q. Line all machinery space boundaries that separate machinery spaces from accommodation spaces with an approved insulation to the satisfaction of an attending Coast Guard Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 September 2022
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing of the fixed fire equipment to the marine inspector. No annual servicing of the fixed system has been completed since July 2021. Provide proof of annual servicing of the pre-engineered fixed fire extinguishing system.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 September 2022
Resolved
Portable and semi-portable fire extinguishers must be inspected and maintained in accordance with NFPA 10. The annual servicing of the portable fire extinguishers has not been conducted. Provide proof of annual servicing of portable fire extinguishers.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 September 2022
Resolved
Provide proof of proper operation of all alarms and shutdowns for the pre-engineered extinguishing systems required by 46 CFR 181.420.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2022
Resolved
Make repairs to leaking water hose in way of bathroom sinks in fresh water pump void.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 September 2022
Resolved
Remove oily water from bilge in aft generator compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 September 2022
Resolved
Prove proper operation of automatic actuation and visual indicator at operating station for the electric submersible bilge pump in the fresh water pump void space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2022
Resolved
The wet exhaust in way of the starboard main engine is leaking. Make repairs to the same.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 September 2022
Resolved
Conductors in way of the shore power connection cables are exposed. Make repairs to the same.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 16 September 2021
Resolved
Fwd toilet water intake thru hull valve has ruptured hose. Valve shall remain closed/secured until hose is repaired to satisfaction of local OCMI. Do not use fwd toilet until repair complete.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2021
Resolved
A grounding strap located in the aft generator space is cut and not connected. Make proper bonding to vessel hull to satisfaction of local OCMI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 June 2020
Resolved
Top deck STBD side mid railing is loose and in need of repair. Repair top deck STBD side mid railing to Marine Inspector satisfaction prior to carrying passengers on the top deck.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2020
Resolved
Repair/replace 03 electrical outlets. 01 in the STBD side aft lounge and 02 in the CAPT fwd quarters to satisfaction of Marine Inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2020
Resolved
Label circuit breaker in generator SWBD cabinet to satisfaction of Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 19 June 2020
Resolved
Anchor windlass electrical system is inoperable. Anchor can be operated manually. Repair electrical system for anchor windlass to satisfaction of Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 19 September 2019
Resolved
Repair or remove inoperable aft generator that is not used.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 September 2019
Resolved
Repair 02 goosenecks vents.
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 18 August 2017
Resolved
Raw water pump of aft SSDG was leaking. Repair or replace pump. 46 CFR 182.420
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 August 2016
Resolved
Vessel short 2 adult Type I pfd's. Total persons limited to 52 until 2 additional Type I adult PFD's are provided per 46 CFR 176.808
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 1 August 2016
Resolved
Provide proof of MIS submission for 2015 per 46 CFR 16
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 1 August 2016
Resolved
Provide copy of company's Random pool per 46 CFR 16
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 August 2016
Resolved
Update expired First Aid kit contents.
Lifesaving › Lifefloat › Painter
Issued 21 September 2011
Resolved
Install painter line and weak link for both of the vessels life floats as required by 46CFR180..175(f)(3).
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 September 2011
Resolved
Repair or replace both life floats water lights as required by 180.175(d).
Lifesaving › Lifefloat › Serviceable
Issued 21 September 2011
Resolved
Service or replace both life floats as required by 46CFR180.175(a).
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 September 2011
Resolved
Attach water light to ring lifebuoy as required by 46CFR180.70(d)(2).
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 September 2011
Resolved
Ensure the first aid kit has the items required by 46CFR160.041 as required by 46CFR184.710.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 August 2008
Resolved
Ensure proper operation of bilge high level alarm in aft steering compartment.
Lifesaving › Buoyant Smoke Signals › General
Issued 30 May 2007
Resolved
Install six orange hand smoke signals IAW 46 CFR 180.68(a)(2)
Navigation › Piloting/Steering › Magnetic Compass
Issued 30 May 2007
Resolved
Install illuminated magnetic compass at the operating station IAW 46 CFR 184.402
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 30 May 2007
Resolved
Demonstrate proper operation of fixed fire extinguishing system (alarm, shutdowns, resets) IAW 46 CFR 181.420
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 May 2007
Resolved
Provide life jacket with safety line for crewmember IAW vessel emergency checkoff list
Communications › Radio Communications › EPIRB
Issued 30 May 2007
Resolved
Place current EPIRB registration sticker on EPIRB
Documentation › Certificates/Documents › Stability Letter
Issued 30 May 2007
Resolved
Conduct a simplified stability proof test IAW 46CFR178.330 to confirm partially protected route and authorization to carry 49 passengers.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 30 May 2007
Resolved
Provide proof of total number of passengers permitted on board IAW 46CFR176.113.
Documentation › Certificates/Documents
Issued 28 August 2003
Resolved
Provide renewal of FCC Safety Radio Telephony Certificate as required by 47 CFR 80.
Lifesaving › Buoyant Apparatus › Operating Controls
Issued 18 July 2002
Resolved
Repair/Replace 15 man life float.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 July 2002
Resolved
Repair fire system so that when energized all engines shut down.
Documentation
Issued 21 August 2001
Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAM AS REQUIRED BY 46 CFR 16.
Lifesaving
Issued 21 August 2001
Resolved
PROVIDE REPLACEMENT HYDROSTAIC RELEASE FOR E-PIRB AS REQUIRED BY 46 CFR 185.740.
Fire Fighting
Issued 21 August 2001
Resolved
PROVIDE SERVICING OF FIXED FIRE FIGHTING EQUIPMENT AND PORTABLE EXTINGUISHERS AS REQUIRED BY 46 CFR 176.810.
Fire Fighting
Issued 2 July 1998
Resolved
PROVIDE AND INSTALL SEPARATE INDICATOR/OVERRIDE SWITCH FOR EACH FIXED FIRE SYSTEM. 46 CFR 181.400.
Documentation
Issued 12 August 1997
Resolved
PROVIDE AND PROPERLY POST FCC SAFETY CERTIFICATE. SEE 47 CFR 90.903.
Documentation
Issued 12 August 1997
Resolved
PROVIDE FCC OPERATOR'S LICENSE. SEE 47 CFR 80.155.
Lifesaving
Issued 12 August 1997
Resolved
PROPERLY MARK LIFEFLOAT PADDLES WITH VESSEL'S NAME IN ACCORDANCE WITH _x001C_ 46 CFR 185.604(G).
Documentation
Issued 12 August 1997
Resolved
PROPERLY PERMANENTLY ENGRAVE THE VESSEL'S DOCUMENTATION NUMBER INTO THE MAIN BEAM OF THE VESSEL IN ACCORDANCE WITH 46 CFR 67.121.
Fire Fighting
Issued 12 August 1997
Resolved
PROVIDE AND PROPERLY INSTALL SMOKE DETECTION SYSTEM MEETING THE REQUIREMENTS OF UL 217 IN ACCORDANCE WITH 46 CFR 181.450.
Electrical
Issued 12 August 1997
Resolved
PROPERLY LABEL ALL ELECTRICAL CIRCUIT BREAKERS AND PANELS. SEE _x001C_ 46 CFR 183.220(D) AND (E).
Accommodation/Occupational Safety
Issued 12 August 1997
Resolved
PROVE THAT GALLEY WASTE RECEPTACLES ARE CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS. SEE 46 CFR 177.405.
Electrical
Issued 12 August 1997
Resolved
PROVIDE DOCUMENTATION THAT THE 40 DEGREE CELSIUS GENERATORS HAVE BEEN DERATED TO 80% OF THE MAXIMUM RATED LOAD. SEE 46 CFR 183.320(B) AND (E).
Lifesaving
Issued 12 August 1997
Resolved
PROVIDE AND PROPERLY POST EMERGENCY CHECK OFF LIST IN ACCORDANCE WITH _x001C_ 46 CFR 185.510.
Accommodation/Occupational Safety
Issued 12 August 1997
Resolved
PROVIDE AND PROPERLY POST WASTE MANAGEMENT PLAN. SEE 33 CFR 151.57.
Lifesaving
Issued 12 August 1997
Resolved
PROPERLY MARK THE LIFEFLOATS WITH VESSEL'S NAME AND CAPACITY OF LIFEFLOAT IN ACCORDANCE WITH 46 CFR 185.604(A) AND (E).
Lifesaving
Issued 12 August 1997
Resolved
PROVIDE AND PROPERLY POST LIFEJACKET DONNING PLACARDS FOR ALL TYPES OF LIFEJACKETS ON BOARD IN ACCORDANCE WITH 46 CFR 185.516.
Documentation
Issued 12 August 1997
Resolved
PROVIDE AND PROPERLY POST FCC STATION LICENSE. SEE 47 CFR 80.15.
Documentation
Issued 12 August 1997
Resolved
PROVIDE EVIDENCE OF FIRST AID/CPR TRAINING FOR 50% OF THE VESSEL'S DECKHANDS. SEE NVIC 1-91.
Documentation
Issued 12 August 1997
Resolved
PROVIDE AND PROPERLY POST VESSEL'S STABILITY LETTER. SEE 46 CFR 176.306.
Lifesaving
Issued 12 August 1997
Resolved
REPLACE THE LIFELINE FOR THE RING BUOY WITH A BLACK, ULTRA-VIOLET RESISTANT60' LINE. SEE 46 CFR 180.70(C).
Lifesaving
Issued 12 August 1997
Resolved
PROPERLY PLACE RETRO-REFLECTIVE TAPE ON THE LIFERING BUOY. SEE _x001C_ 46 CFR 185.604(B)(I).
Lifesaving
Issued 12 August 1997
Resolved
PROPERLY PLACE SEPARATION DEVICES BETWEEN THE LIFEFLOATS. SEE _x001C_ 46 CFR 180.137(F).
Navigation
Issued 12 August 1997
Resolved
PROVIDE APPROPRIATE CHARTS AND PUBLICATIONS IN ACCORDANCE WITH _x001C_ 46 CFR 184.420.
Engineering
Issued 12 August 1997
Resolved
PROVIDE AND INSTALL FUEL STOP VALVES AT THE ENGINE END OF THE FUEL LINES ONBOTH MAIN ENGINES. SEE 46 CFR 182.455(B)(4).
Engineering
Issued 12 August 1997
Resolved
PROPERLY LABEL EMERGENCY FUEL VALVES IN ACCORDANCE WITH 46 CFR 185.608.
Electrical
Issued 12 August 1997
Resolved
PROVIDE AND PROVE THE PROPER OPERATION OF EMERGENCY LIGHTING IN ACCORDANCE WITH 46 CFR 183.432.
Casualty record · 1
18 July 2023Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 7802922
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.