Records from 1997 to 2017. Most recent: inspection, 11 August 2017.
Inspection history · 37
11 August 2017
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6237529
27 April 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6133484
25 July 2012
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4389833
25 May 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4321577
2 January 2010
COE-Dockside
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3657666
24 July 2009
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3544518
20 April 2009
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3457000
16 July 2008
ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3269510
14 July 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3268141
25 January 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3136137
23 January 2008
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3134947
22 January 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3134649
15 January 2008
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3130555
8 October 2007
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3075504
22 October 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1693935
20 August 2002
Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1663723
12 June 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1629680
12 June 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1629785
7 May 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1613827
25 March 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1597332
13 February 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1486321
8 January 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1476677
7 January 2002
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1476068
6 June 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 290684
3 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 278401
10 March 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 275608
20 January 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 467912
9 December 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 474436
10 September 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 432591
18 June 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 429754
3 February 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 425084
23 July 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 418332
23 June 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 416563
7 February 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 412802
6 January 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 424077
19 July 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 405941
17 July 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 405921
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 24 July 2009
Resolved
Excessive oil found accumulated on vessel's fuel oil booster unit, creating a potential fire hazard. Vessel shall repair any leaks and remove oil to the satisfaction of the certificate issuing authority. SOLAS 74 (92 CONS ED) CH II-1 Part C Reg 26.1.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2009
Resolved 28 August 2009
Resolution: Received class report attesting to repairs
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 24 July 2009
Resolved
Excessive oil in bilges under ship service generator #2 found, creating a potential safety and fire hazard. Vessel shall repair any leak and remove oil to the satisfaction of the certificate issuing authority. (SOLAS 74 (92 CONS ED) CH II-1 Part C Reg 26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2009
Resolved 28 July 2009
Resolution: Received class report attesting to repairs.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 24 July 2009
Resolved
Numerous rags (oil-soaked) found in engine room, particularly around main engine and generator #1 creating fire hazard. repair and remove leaks and rags to satisfaction of class. (SOLAS 74 (92 CONS ED) II-I part C reg 26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2009
Resolved 28 July 2009
Resolution: Received class report attesting to repairs.
Lifesaving › Lifeboat › Carriage Requirement
Issued 24 July 2009
Resolved
Vessel shall provide enough food rations for the total capacity of lifeboat. Approximately 95% of food packages on board have lost their air-tight seal, damaging food. Vessel shall replace damaged food packages. Replace to the satisfaction of the coastguard. SOLAS (92 CONS ED) III Part C Reg 41.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2009
Resolved 24 July 2009
Resolution: Received class report attesting to replacements of damaged rations.
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 24 July 2009
Resolved
PSCO unable to test/run engine on rescue boat due to inoperable battery. Vessel's rescue boat shall be readily available at all times. Fix to satisfaction of class. SOLAS 74 (92 CONS ED) CH III Part B Reg 19.2
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2009
Resolved 28 July 2009
Resolution: Received class report attesting to repairs.
Engineering › Compressed Air System (control) › Valve
Issued 23 January 2008
Resolved
Control air malfunction caused by sediment and condensation in air piping. All air systems associated with propulsion cleaned and overhauled. Def will be cleared with Class report attesting to satisfactory full power sea trial. Tugs were required on both inbound and outbound of Port.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 30 January 2008
Resolution: Received GL class report attesting to overhauling of all air systems associated with main engine, as well as satisfactory dockside trial (see document attached to activity 3134947).
Construction/Loadline
Issued 18 June 1999
Resolved
THE WATER TIGHT DOOR FROM ENGINEROOM TO GENERATOR ROOM WILL NOT CLOSE DUE TO PERMANENT PIPE IN WAY. MUST RELOCATE PIPE SO DOOR WILL CLOSE TO THE SATISFACTION OF CLASS SOCIETY PRIOR TO 18AUG99.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Fire Fighting
Issued 18 June 1999
Resolved
VENT LOUVERS IN ENGINEROOM WILL NOT CLOSE. MUST CORRECT TO SATISFACTION OF CLASS SOCIETY PRIOR TO 18AUG99.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Fire Fighting
Issued 18 June 1999
Resolved
VESSEL'S INCINERATOR SPACE IS NOT ON THE FIRE CONTROL PLANS. VESSEL MUST UPDATE FIRE CONTROL PLANS TO THE SATISFACTION OF CLASS SOCIETY PRIOR TO 18AUG99.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Fire Fighting
Issued 18 June 1999
Resolved
FIRE SCREEN DOORS TO INCINERATOR ROOM WILL NOT LATCH. MUST PROVE PROPER OPERATION OF FIRE SCREEN DOORS TO CLASS SOCIETY PRIOR TO 18AUG99.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Fire Fighting
Issued 18 June 1999
Resolved
THE INTERNATIONAL SHORE CONNECTION WAS MISSING ALL BOLTS, NUTS, AND WASHERS. MUST CORRECT TO THE SATISFACTION OF CLASS SOCIETY PRIOR TO 18AUG99.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Navigation
Issued 23 June 1998
Resolved
THE GYRO REPEATER IN THE STEERING GEAR ROOM IS INOPERATIVE.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Navigation
Issued 6 January 1998
Resolved
U.S. COAST PILOT NOT UPDATED THROUGH LOCAL NOTICE TO MARINERS 1999 TIDE/CURRENT TABLES NOT ON BOARD.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Lifesaving
Issued 6 January 1998
Resolved
VESSEL >100M MISSING FORWARD LIFERAFT.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Engineering
Issued 17 July 1997
Resolved
OIL AT TRANSFER POINT NEEDS TO BE CLEANED.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Engineering
Issued 17 July 1997
Resolved
PROVIDE PROPER CONTAINMENT FOR LEAKING OIL FROM FUEL OIL SERVICE TANK IN ENGINE ROOM.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Electrical
Issued 17 July 1997
Resolved
LIGHTS IN ENGINE ROOM HAD PLASTIC COVERS.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Documentation
Issued 17 July 1997
Resolved
MASTER AND SECOND OFFICER MISSING HAZMAT TRAINING.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997