MAURY USCG vessel records
← All vessels

EMERALD ISLE

EMERALD ISLE is a 1997 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in May 2026, along with 11 deficiencies — 1 with no resolution recorded — and 7 casualty investigations between 2006 and 2013.

Records from 2006 to 2026. Most recent: inspection, 7 May 2026.

Built
1997
Last inspected
7 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

8967840
WCX7834
461095
Flag
UNITED STATES
Maury page id
psix-461095

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…past their stated due date1
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)116.9 ft × 38.0 ft × 12.0 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)116.9 ft × 38.0 ft × 12.0 ft
ITC tonnagegross 580 / net 226
BuilderWASHBURN & DOUGHTY · EAST BOOTHBAY, ME, UNITED STATES · built 1997
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBEAVER ISLAND, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it580 - Convention (Subpart B), Gross Ton
95 - Regulatory (Subpart C or D), Gross Ton
226 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 26

7 May 2026 MTSA Verification · COI Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8357967
3 September 2025 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8227545
15 May 2025 Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8140810
11 September 2024 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8001242
24 June 2024 Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7954929
6 June 2023 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7751462
8 September 2022 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7554905
10 May 2022 MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7457451
5 May 2022 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7444470
16 August 2021 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7290571
16 March 2021 MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7157223
28 April 2020 MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6944998
26 September 2019 Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6826144
20 September 2019 Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6819790
9 September 2019 Examination of Repairs · Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6818598
14 August 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6783583
24 May 2019 MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6692428
25 May 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6423400
29 August 2017 Deficiency Check · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6255173
24 July 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6221684
24 July 2017 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6269626
11 July 2017 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6214351
13 May 2017 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6146379
14 November 2016 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6040546
21 April 2016 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5865150
13 April 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5857901

Deficiency record · 11

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 May 2026 No resolution recorded
Sighted 2 steering compartment structure fractures: Keelson structure/weld cracked at seam of keelson & 2nd from fwd transverse structure; Stbd forwardmost side-shell structure cracked at lowest sidelong structure intersection. Make temporary repairs as agreed upon. Weekly crew inspections are required, any repair degradation shall be immediately reported to the cognizant [name withheld] repairs are required NLT the vessels next scheduled dry-docking/hull exam.
Action required: 705 - Other - as specified
Due 14 May 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 10 May 2022 Resolved
Port steering ram inboard mounting plate has approved temporary repairs. Complete permanent repairs and satisfactory testing NLT at next shipyard availability period. ** Temp repair shall inspected daily. Any degradation of repair shall be immediately reported to the cognizant OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 15 June 2022
Resolution: The ram mounting plate was renewed. Steering was tested and the repairs were approved and adequate.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 August 2019 Resolved
Effect repairs and demonstrate proper operation of the backup electrical motor pump. While this pump in inoperative 1 portable pump must be on board and readily available to the crew at all times. Crew must be properly trained to operate the substitute portable pump.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 10 September 2019
Resolution: pump replaced and tested, all sat.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 May 2018 Resolved
Small gauge wires connected directly to positive terminals on main and bowthruster engine starting batteries wires have no means for emergency disconnect or de-energizing to service fuses. All such conductors, except for the battery chargin circuits must be removed and reconnected to acceptable location on load side of the main disconnect switch.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2018
Resolved 6 June 2018
Resolution: Wiring has been moved to battery disconnect switch.
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 29 May 2018 Resolved
Wiring for port main engine block heater must be corrected in way of the junction box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2018
Resolved 6 June 2018
Resolution: Wires properly secured.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 29 May 2018 Resolved
Each vent shut down switch actuated by CO2 pressure from fixed extinguishing system for the engineroom and bowthruster space must be labeled to identify affected equipment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2018
Resolved 6 June 2018
Resolution: Valves properly labeled.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 29 August 2017 Resolved
Repair leaking lube oil line on starboard engine turbo prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2017
Resolution: repaired.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 July 2017 Resolved
Servicing company's report not credible due to invalid data and unacceptable actuation of pneumatic discharge time delays. Conduct full annual service and inspection of both fixed CO2 fire extinguishing systems.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 24 July 2017
Resolution: Witnessed servicing, significant comments in General Info narrative.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 13 May 2017 Resolved
Vessel to correct issue with overpressure on port side engine crankcase
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2017
Resolved 13 May 2017
Resolution: Cat tech issued report that issue was corrected.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 13 April 2016 Resolved
Provide insulation on bow thruster exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 22 April 2016
Resolution: See emails (4/14/16 and 4/22/16) from [name withheld]
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 13 April 2016 Resolved
Tighten insulation on port main diesel propulsion engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 22 April 2016
Resolution: See emails (4/14/16 and 4/22/16) from [name withheld]

Casualty record · 7

23 October 2006Routine · role: Involved in a Marine Casualty · activity 2813592
9 August 2008Routine · role: Involved in a Marine Casualty · activity 3302850
4 October 2008Routine · role: Involved in a Marine Casualty · activity 3344227
25 August 2011Routine · role: Involved in a Marine Casualty · activity 4127593
28 August 2012Routine · role: Involved in a Marine Casualty · activity 4431584
29 May 2013Routine · role: Involved in a Marine Investigation (non-casualty) · activity 4606596
25 June 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4632985
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.