MAURY USCG vessel records Sign in
← All vessels

VOYAGER

VOYAGER is a 1968 passenger vessel (inspected). The Coast Guard has recorded 108 inspections since 1985, most recently in January 2026, along with 245 deficiencies, 6 operational controls and 3 casualty investigations between 2014 and 2018.

Records from 1985 to 2026. Most recent: inspection, 6 January 2026.

Built
1968
Last inspected
6 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE5209
Flag
UNITED STATES
367363460
Maury page id
psix-46111

Inspections, by type

…with no type recorded20
Years with a record 37 calendar years (1985–2026)
The 108 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.9 ft × 18.0 ft × 8.0 ft
Registered tonnagegross 80 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderYACHT DYNAMICS INC. · HARBOR CITY, CA, UNITED STATES · built 1968
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 24 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it80 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE5209MMSI 367363460 · active · compulsorily equipped · granted 3 April 2018, expires 18 June 2028
WCY3564MMSI not assigned · expired · compulsorily equipped · granted 4 May 1998, cancelled 5 July 2008
WAK9079MMSI not assigned · expired · voluntarily equipped · granted 31 May 1995, cancelled 2 July 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 108

6 January 2026 Hull Examination · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8290841
5 June 2025 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8152177
2 July 2024 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7947190
11 January 2024 Internal Structural Exam · Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7847839
27 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7721654
21 June 2022 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7480218
9 February 2022 Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7393755
11 January 2022 Examination of Repairs · Hull Examination · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7378239
21 April 2021 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7179400
20 July 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7011780
30 January 2020 Drydock Exam · Deficiency Check · In-Service Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6897397
24 June 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6724018
21 July 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6512161
19 June 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6420417
23 January 2018 Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6345462
25 April 2017 Internal Structural Exam · Plan Review "T" Boat · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6132676
27 March 2017 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6112649
26 March 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6111611
25 March 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6112257
11 January 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6069551
21 November 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6045166
17 October 2016 Excursion Permit · Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6024053
12 April 2016 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5852401
19 January 2016 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5799929
6 November 2015 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5759166
11 October 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5003400
11 October 2014 Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5006567
11 October 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5008561
24 June 2014 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4898790
27 July 2012 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4392463
23 January 2012 Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4227288
26 January 2010 Plan Review "T" Boat · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3670050
29 April 2008 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3186125
14 February 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3147698
15 January 2008 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3123642
26 July 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3007734
26 January 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2863385
27 April 2006 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2634843
15 February 2006 Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2613849
6 February 2006 Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2573163
6 December 2004 Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2235090
19 April 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2047923
3 February 2004 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1990091
30 January 2004 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1990087
22 August 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1665137
17 July 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1647673
4 April 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1601046
28 February 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1489546
23 January 2002 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1480908
20 December 2001 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1474073
19 April 2001 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1408719
14 August 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 821494
11 July 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384502
2 June 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 818862
28 May 2000 Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 1517554
27 May 2000 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1049451
13 January 2000 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1437652
3 December 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 811581
5 November 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1404865
22 June 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1469271
19 January 1999 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1031748
12 June 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1126168
13 May 1998 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 791316
13 November 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 775835
16 January 1997 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1100480
10 October 1996 COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1371426
26 March 1996 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1078547
6 March 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1077635
5 March 1996 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 886250
9 November 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 658405
7 August 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 879189
14 July 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 884207
16 December 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 842739
8 December 1994 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1142745
3 December 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 63124
3 December 1994 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1181622
31 May 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 868546
10 May 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1169457
25 April 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1167814
23 March 1994 Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 856113
18 March 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387351
6 January 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 832946
27 October 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1265977
23 September 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 937752
4 August 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1265138
22 May 1992 Damage Survey · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1254865
24 April 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 138038
10 April 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 952220
6 May 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 913812
4 April 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1213600
23 January 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 907154
30 November 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1223986
21 March 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1225297
8 February 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 916560
11 July 1989 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1345167
6 July 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1036094
3 May 1989 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1198889
8 November 1988 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1203108
7 September 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1348960
15 August 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1039084
17 May 1988 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1042857
2 June 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1027638
6 May 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1021072
23 September 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1005189
20 May 1986 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 989308
23 July 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 978062
18 June 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 980302
17 May 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1289836

Deficiency record · 245

10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 June 2025 Resolved
Each vessel must be marked as required by part 67, subpart I, of this chapter: The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel in clearly legible letters not less than four inches in height. Name and Hailing Port markings were removed for for hull painting. 46 CFR 185.602(a)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2025
Resolved 7 August 2025
Resolution: Received photo evidence of vessel name and hailing port markings affixed to vessel's hull satisfying the issued deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 5 June 2025 Resolved
If a vessel operates on exposed or partially protected waters, an opening port light is not permitted below the weather deck unless it has an inside, hinged dead cover. Hinged dead covers for port and starboard-side port lights located in forward crew accommodation below main deck did not close properly. Provide means to close that is sufficient enough to prevent water intrusion if glass windows fail. 46 CFR 171.119(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 1 July 2025
Resolution: MI received photo evidence satisfying requirement.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 June 2025 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Light fixture in damage prone location of forecastle missing a guard. 46 CFR 183.410(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 1 July 2025
Resolution: MI received photo evidence satisfying requirement.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 June 2025 Resolved
A lighting fixture may not be used as a connection box for a circuit other than the branch circuit supplying the fixture. The light fixture in forecastle was used as a junction box and outlet. 46 CFR 183.410(b)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 1 July 2025
Resolution: MI received photo evidence satisfying requirement.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 June 2025 Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. A pair of fuel filters forward of starboard engine are missing flame shields. 46 CFR 182.455(b)(6)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 1 July 2025
Resolution: MI received photo evidence satisfying requirement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 June 2025 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing. Various wire runs in the forecastle and black water void were found without required metallic supports and run through holes in aluminum deck stiffeners without chafing protection. 46 CFR 183.340(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 1 July 2025
Resolution: MI received photo evidence satisfying requirement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 June 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. E/R breaker box on starboard side had an opening/missing breaker creating a potential shock hazard. Remove hazard to satisfaction of MI. 46 CFR 183.200 (c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 1 July 2025
Resolution: MI received photo evidence satisfying requirement.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 June 2025 Resolved
Drills required by § 185.524 (fired drills and training), including fire location and fire type; and Emergency egress training for each member of the crew, to occur for all members of the crew—(i) At least monthly while such members are employed on board the vessels; and (ii) Each time a crew member joins the crew of such vessel. Vessel drill log revealed there were several-month gaps between entries. Drills conducted and logged during inspection. 46 CFR 185.420
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 June 2025
Resolved 19 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 July 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including ... Operation of the fire main system... During test of fire pump, Marine inspector observed discharge piping leaking at the pipe fitting. Vessel not to carry more than 49 passengers until satisfactory permanent repair is made. 46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2024
Resolved 26 July 2024
Resolution: Witnessed operation of fire pump
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 July 2024 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems... must be conspicuously marked as follows: (1) Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.”. (2) Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted...Signs for space storing CO2 and CO2 protected space are incorrectly marked. 46 CFR 185.612(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2024
Resolved 26 July 2024
Resolution: Proper signs installed
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 July 2024 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Marine inspector observed life float light inoperable. 46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2024
Resolved 26 July 2024
Resolution: Operator replaced all floating water lights
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 3 July 2024 Resolved
Special attention should be paid to: Magnetic variation and deviation errors of the compass. Vessel was not provided a magnetic compass deviation table. 46 CFR 185.304(a)(8)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2024
Resolved 26 July 2024
Resolution: Operator has provided magnetic compass deviation table.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 July 2024 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Drill log does not include description of drill scenario or training topics. 46 CFR 185.520(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2024
Resolved 26 July 2024
Resolution: Operator has implemented new log form for emergency/safety drills and training.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 July 2024 Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. Each port light installed below the bulkhead deck must...be constructed so that it can be secured watertight. MI observed numerous port lights with seized latches, additioanlly portlight in starboard galley prep area was missing a latch. 46 CFR 177.13-1 (Old T)46 CFR 171.116(f)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2024
Resolved 11 October 2024
Resolution: OCMI issued special consideration for utilizing aluminum plate covers in lieu of hinged latches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 July 2024 Resolved
Attention shall be paid to insure that... protective devices are provided in all hazardous places. MI observed broken guard on port generator. 46 CFR 176.25-10(b) (Old T)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2024
Resolved 26 July 2024
Resolution: Operator repaired guard
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 July 2024 Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. MI observed junction box in forward storage space overhead without a cover. 46 CFR 183.05-50(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2024
Resolved 26 July 2024
Resolution: Installed cover
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 July 2024 Resolved
Paint and flammable liquid lockers must be constructed of steel or equivalent. MI observed flammable liquids stowed in forward storage space. 46 CFR 177.405(d)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 3 July 2024
Resolved 3 July 2024
Resolution: Vessel removed flammable liquids during inspection.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 2 July 2024 Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Starboard pilot house window glass is cracked. 46 CFR 177.1020
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2024
Resolved 10 September 2024
Resolution: Operator provided photograph of replaced windows.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2023 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Piping for raw water system had substantial leak due hot water heater breaking pipe. Repair pipe and secure heater to the satisfaction of the marine inspector. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2023
Resolution: Repaired pipe and secured heater.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2023 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Hydraulic leak found on steering system. Repair system to the satisfaction of the marine inspector. 46 CFR 176.814
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2023
Resolution: Repaired system
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2023 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in for the service in which they are to be employed. Excess fuel found in the engine room, due to possible fuel leak. Clean fuel, determine source of leak, and repair to the satisfaction of the marine inspector. 46 CFR 176.840
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2023
Resolution: Repaired leak
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 27 June 2023 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. During the inspection of the pump room area, there was built up debris in the space preventing marine inspector from inspecting the space. Clean bilge of excess debris. 46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 28 July 2023
Resolution: Cleared debris and MI inspected space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2023 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Raw water leak found on generator. Repair to the satisfaction of the marine inspector. 46 CFR 182.100
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 29 June 2023
Resolution: Repaired leak
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2023 Resolved
Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of the boat. Battery was not secured and was moving while vessel is underway. Secure the battery. 46 CFR 183.05-20(b) “OLD T”
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 29 June 2023
Resolution: Secured battery.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 27 June 2023 Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads of double diagonal wood, marine plywood, steel plate, or equivalent construction. Door to engine room had gasket pieces missing and was allowing air flow to accommodation spaces. Repair to the satisfaction of the marine inspector. 46 CFR 182.35-1(a) “OLD T”
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 26 September 2023
Resolution: Replaced missing gasket
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 June 2023 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. No date was listed on hydrostatic release. Provide date of install and properly mark or replace hydrostatic release unit. 46 CFR 185.740(b)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 29 June 2023
Resolution: Updated hydrostatic release.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 27 June 2023 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Operator did not have fire servicing report. Provide report to the marine inspector. 46 CFR 176.810(b)(1)(iv)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 29 June 2023
Resolution: Provided proof of fire servicing report.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 27 June 2023 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: (1) Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.”.(2) Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. (3) Spaces into which carbon dioxide might migrate—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. DISCHARGE INTO NEARBY SPACE CAN COLLECT HERE. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED VACATE IMMEDIATELY.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. No signs were posted. Post signs to the satisfaction of the marine inspector. 46 CFR 185.612(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 28 July 2023
Resolution: Added sign to accomodation space
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 27 June 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems. Due to a birds nest in one of the Life Floats, the Marine Inspectors were unable to successfully inspect the life floats. Clear out nest and make available for Marine Inspectors to inspect. 46 CFR 176.808(a)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2023
Resolved 26 September 2023
Resolution: Once bird nest cleared, MIs inspected float.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2023 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Starboard shaft seal is leaking excessive water during operation. Repair to the satisfaction of the Marine Inspector. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2023
Resolved 28 July 2023
Resolution: Repaired leak
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 June 2022 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Acepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB on the vessel was not installed to float free, the hydrostatic release was expired, and the battery was expired. Vessel is restricted to operating no more than three nautical miles from shore until cleared. 46CFR180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 July 2022
Resolution: Operator installed new epirb in a float free arrangement with an up-to-date battery and current hydrostatic release.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 June 2022 Resolved
All machinery installed and maintained in such a manner as to afford adequate protection against machinery failure. Starboard main diesel engine wet exhaust supply hose leaking at a steady drip. Replace supply hose to satisfaction of attending Marine Inspector. 46CFR182.01-5 'Old T'
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2022
Resolved 28 July 2022
Resolution: Operator replaced hose in kind to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 21 June 2022 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Starbord 22 person life float did no have a floating water light. Attach CG approved floating water light IAW 46CFR180.175(f)(4). 46CFR180.175(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2022
Resolved 28 July 2022
Resolution: Operator attached water lights, verified by MI.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 21 June 2022 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. The electrical cable for the electric Jabsco water pump located in the engine room is chafing on the fuel shut off valve cables. Reroute electrical cable to eliminate chafing. 46CFR183.220(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 28 July 2022
Resolution: Electrical cable re-routed to eliminate chafing.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 21 June 2022 Resolved
Each window must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. The port pilothouse window glass is cracked. Replace glass. 46CFR177.1020
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 28 July 2022
Resolution: Operator replaced broken pilothouse window to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 11 January 2022 Resolved
At each initial and subsequent inspection for certification, the marine inspector shall examine all accessible parts of the exterior and interior of the hull. The vessel's through hull valves showed significant corrosion that could not be inspected. Clean and make available for reinspection. 46 CFR 176.25-5 (a)(1) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2022
Resolved 4 February 2022
Resolution: Witnessed successful NDT of aluminum inserts for the affected areas.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 11 January 2022 Resolved
On passenger decks of vessels engaged in a ferry or excursion type operations, rails shall be at least 42 inches high. The space below the rail shall be fitted with bulwarks, chain link fencing, wire mesh, or the equivalent. The vessel did not have the appropriate courses for the vessel's railings. 46 CFR 177.35-1(c) (OLD T)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 February 2022
Resolved 31 March 2022
Resolution: Visual inspection of the new canvas installation for the railings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2021 Resolved
VESSEL'S SWITCHBOARD SHALL FOLLOW THE SWITCHBOARD REGULATIONS FOUND IN (OLD) 46 CFR 111.30-1 (C). SWITCHBOARDS SHALL HAVE NONCONDUCTING HANDRAILS AT THE FRONT. EACH SWITCHBOARD SHALL HAVE A DRIP-COVER OVER THE TOP. NONCONDUCTING MATS OR GRATINGS SHALL BE PROVIDED ON DECK IN THE FRONT OF THE SWITCHBOARD. DISCOVERED THE VESSEL'S SWITCHBOARD DID NOT HAVE NONCONDUCTING MATS, HANDRAILS AND A DRIP-COVER OVER THE TOP OF THE UNIT. 46 CFR 111.30-1 (c) (OLD)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2021
Resolved 22 June 2021
Resolution: Operator provided sufficient photos (in the documents tab) of drip shield, rubber mats and handles around the electrical panel.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 21 April 2021 Resolved
PIPING, INCLUDING VALVES, PIPE FITTINGS AND FLANGES, CONVEYING VAPOR, GAS, OR LIQUID, THE TEMPERATURE OF WHICH EXCEEDS 65.5 °C (150 °F), MUST BE SUITABLY INSULATED WHERE NECESSARY TO PREVENT INJURIES. DISCOVERED MISSING PORTIONS OF INSULATION OF THE VESSEL'S ENGINE EXHAUST PIPING. 46 CFR 177.970
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 1 May 2021
Resolution: Operator sent photographs of installed installation (lagging) on missing portions of vessel's engine exhaust piping (see documents).
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2021 Resolved
EACH LIFE JACKET MUST BE MARKED WITH TYPE I RETROREFLECTIVE MATERIAL APPROVED IN 46 CFR 164.018. AS PER IMO RESOLUTION A.658(16), IN THE CASE OF A REVERSIBLE LIFE JACKET, THE ARRANGEMENT SHOULD BE COMPLIED WITH NO MATTER WHICH WAY THE LIFE JACKET IS PUT ON. DISCOVERED THAT ONE OF THE SIDES OF EACH 05 LIFE JACKETS WERE MISSING THE APPROVED RETROREFLECTIVE MATERIAL.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 30 April 2021
Resolution: Operator sent photographs of correct retroreflective arrangment for called out life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 July 2020 Resolved
At least one ring life buoy must be fitted with a lifeline. Each ring life buoy must be resistant to deterioration from ultraviolet light. MI found ring life buoy lifeline to be severely deteriorated from UV light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 August 2020
Resolved 18 September 2020
Resolution: Ring Life Buoy was replaced with new line.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 July 2020 Resolved
Electrical equipment exposed to the weather must be watertight. MI found hanging on the canopy lights on the upper deck not watertight receptacle.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 August 2020
Resolved 18 September 2020
Resolution: Canopy lights were removed and outlet made weather tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2019 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The vessel’s port and starboard shaft packing glands are leaking at an excessive rate. The vessel’s port shaft packing gland is leaking at a rate of 3-5 drops per second, and the starboard shaft packing gland is leaking at a steady rate of one cup per minute. Repair shaft packing glands to the satisfaction of the attending Marine Inspector. 46 CFR 182.05-1 “Old T”
Action required: 17 - Rectify deficiencies prior to departure
Due 2 July 2019
Resolved 3 July 2019
Resolution: Attended vessel to inspect shaft seals. Repaired to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 June 2019 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The starboard main propulsion engine is leaking at the raw water pump housing at a rate of half cup per minute. Repair raw water pump housing to the satisfaction o the attending Marine Inspector. 46 CFR 182.05-1 “Old T”
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2019
Resolved 15 July 2019
Resolution: Proof of repair sent to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 June 2019 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 06 life jackets were not ready for immediate use. 02 life jackets required new retro-reflective tape and 04 had holes and need to be replaced. Vessel is restricted to the carriage of 74 passengers until the PFD’s are replaced to the satisfaction of the MI. 46 CFR 176.806 (b)
Action required: 705 - Other - as specified
Due 2 July 2019
Resolved 15 July 2019
Resolution: Proof of procurement provided to satisfaction of MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2019 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock or personnel. Vessel has several dead-end wires in the forward accommodation space and in the engine room. Remove dead end wires IAW 46 CFR 183. 46 CFR 183.01-5 “Old T”
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2019
Resolved 15 July 2019
Resolution: Proof of repair sent to satisfaction of MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2019 Resolved
Each connection to a conductor must be made within an enclosure. The vessel was using outlets to energize the permanently installed lighting fixtures. Rewire the lighting fixtures IAW 46 CFR 183.340.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2019
Resolved 15 July 2019
Resolution: Proof of repair provided to satisfaction of MI.
Engineering › Bilge Water Management System › Interface Detector
Issued 19 June 2018 Resolved
46 CFR 182.530 - A visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space. Visual and audible alarm associated with E/R were both barely perceptable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 June 2018
Resolved 19 June 2018
Resolution: Vessel proved proper operation of visual and audible signal from the bridge.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 June 2018 Resolved
46 CFR 185.728 - Each EPIRB must be tested monthly. Owner could not provide proof of testing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 June 2018
Resolved 19 June 2018
Resolution: Crew conducted and logged test.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 19 June 2018 Resolved
46 CFR 183.350 - Connections must be made to battery terminals with permanent type connectors. Several batteries were connected via wingnuts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 22 June 2018
Resolution: Received phots from owner showing replacement of wingnuts.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 27 March 2017 Resolved
Tighten and Seal all deisel fuel overfill and fill pipes to ensure that overflow of liquid or vapor cannot escape to the inside of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 25 April 2017
Resolution: Witness proper sealing of the pipes.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 18 April 2016 Resolved
Provide proof that all employed deckhands are enrolled in company DAPI program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 22 April 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2016 Resolved
Remove portable cables throughout the vessel: bar, wheelhouse.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 27 April 2016
Engineering › Reduction Gearing/Clutches › Bearing
Issued 11 October 2014 Resolved
Prove proper operation of main propulsion following repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2015
Resolution: Satisfactory sea trials conducted.
Engineering › Lubricating Oil Service System › Gauge
Issued 25 June 2014 Resolved
Repair and prove proper operation of oil pressure indicator for generator at operating station in wheelhouse.
Action required: 705 - Other - as specified
Due 16 February 2015
Resolved 28 January 2015
Resolution: Gauge now operational.
Fire Fighting › Fire Hoses › Condition
Issued 25 June 2014 Resolved
Replace and prove proper operation of 50ft UL 19 approved fire hose.
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 16 January 2015
Resolution: Fire hose replaced, conducted operational test.
Fire Fighting › Fire Pumps › Suction Valve
Issued 25 June 2014 Resolved
Repair and prove proper operation of firemain sea suction for fire pump. Pressure on gauge must must be no less than 60psi.
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 16 January 2015
Resolution: Pump tested to 80 psi.
Electrical › Electric Supply System (service) › Cable
Issued 25 June 2014 Resolved
Ensure all electrical wiring in engine room is secured with appropriate metal supports and in such a manner to avoid chafing every 24 inches.
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 16 January 2015
Resolution: Corrected, but not applicable to old T vessels.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 August 2012 Resolved
Provide eye dressing, ammonia inhalents, iodine, and aspirin onboard.
Condition: Improper/Lack of Maintenance
Due 9 August 2012
Resolved 15 August 2012
Resolution: All items provided onboard, documented with purchase receipt and pictures of items.
Electrical › Electric Generation Source (service) › Generator
Issued 27 July 2012 Resolved
Install double hose clamps on starboard generator muffler.
Condition: Improper/Lack of Maintenance
Due 27 July 2012
Resolved 27 July 2012
Resolution: Two hose clamps installed on starboard muffler
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 July 2012 Resolved
Provide current certificate of documentation onboard.
Condition: Invalid
Due 9 August 2012
Resolved 9 July 2012
Resolution: E-mail proof provided.
Documentation › Logs/Records › Drug Test Records
Issued 9 July 2012 Resolved
Provide proof of current random drug testing results.
Due 16 July 2012
Resolved 20 July 2012
Resolution: Random testing enrollment records provided.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 9 July 2012 Resolved
Provide FCC Radio operator license. 47 CFR 80
Due 16 July 2012
Resolved 15 August 2012
Resolution: Received copy of valid marine radio operator permit for master [name withheld]
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 9 July 2012 Resolved
Install lagging on port inboard exhaust pipe.
Condition: Improper Installation
Due 16 July 2012
Resolved 20 July 2012
Resolution: Lagging installed on all exposed exhaust piping.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 9 July 2012 Resolved
Provide ventilation closure for engine room ventilation duct.
Condition: Improper Installation
Due 16 July 2012
Resolved 20 July 2012
Resolution: Closure provided on engine room ventilation duct.
Stability › Watertight Integrity › General
Issued 9 July 2012 Resolved
Prove watertight integrity of starboard galley port light.
Condition: Damaged By Earlier Event
Due 16 July 2012
Resolved 20 July 2012
Resolution: New glass installed in starboard galley port light
Electrical › Electrical Distribution System (service) › Cable
Issued 9 July 2012 Resolved
Support all wire runs in engine room.
Condition: Improper/Lack of Maintenance
Due 9 August 2012
Resolved 15 August 2012
Resolution: All wire runs supported, junction boxes properly installed on loose ends.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 9 July 2012 Resolved
Replace or repair jacketwater hose damaged on aft starboard engine.
Condition: Improper/Lack of Maintenance
Due 9 August 2012
Resolved 20 July 2012
Resolution: Damaged hose run replaced and protected from chafing with foam
Electrical › Electrical Distribution System (service) › Cable
Issued 26 January 2010 Resolved
Remove all excess wiring and properly bundle exsisting wiring outboard stbd main engine. In accordance with 46 CFR 183.340(b)(4)(5)(6).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 26 February 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 January 2010 Resolved
Renew exhaust lagging outboard port main engine, add lagging to inboard exhaust manifold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 26 February 2010
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 January 2010 Resolved
Clean engineroom bilges and make available for inspection outboard and aft to the transom for both port and stbd generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 28 January 2010
Engineering › Bilge Water Management System › Piping
Issued 26 January 2010 Resolved
Remove or re-attach piping aft engine room behind batteries, running port and stbd and then forward.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 26 February 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 26 January 2010 Resolved
Find and fix all oil leaks outboard stbd main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 26 February 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 January 2010 Resolved
Permanantly mount stbd shaft guard cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 26 February 2010
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 26 January 2010 Resolved
Properly attach stbd gererator f/o pump inboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 26 February 2010
Engineering › Lubricating Oil Service System › Gauge
Issued 26 January 2010 Resolved
Renew gauge or remove and plug port main diesel engine oil filter gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 26 February 2010
Electrical › Electric Generation Source (service) › Power Requirement
Issued 26 January 2010 Resolved
Provide new data plate placard for stbd generator for a rated output at 50*c
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 26 February 2010
Fire Fighting › Fire Main › Material
Issued 26 January 2010 Resolved
Replace rubber hose for installed fire pump stbd inboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 26 February 2010
Electrical › Electric Generation Source (service) › Generator
Issued 26 January 2010 Resolved
Provide ampacity data for the stbd generator operating at 50 deg centigrade and provide the definition of "Meets Coast Guard Safety Standards dated 3-93"
Action required: 705 - Other - as specified
Due 31 March 2010
Resolved 20 July 2010
Resolution: Vessel provided the attending marine inspector with the ampacity data for 50 deg centigrade.
Electrical › Electric Generation Source (service) › Generator
Issued 26 January 2010 Resolved
Provide onboard overcurrent protection for port generator IAW 46 CFR 183.320.
Action required: 705 - Other - as specified
Resolved 20 July 2010
Resolution: Installed a 80amp breaker for the portside generator.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 April 2008 Resolved
Properly label 02 stowage areas with amount of jackets stowed.
Due 29 May 2008
Resolved 29 April 2008
Resolution: Corrected
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 April 2008 Resolved
Masthead light ooc.
Due 29 May 2008
Resolved 29 April 2008
Resolution: Corrected
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 April 2008 Resolved
Anchor light ooc.
Due 29 May 2008
Resolved 29 April 2008
Resolution: Corrected
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Pressure
Issued 29 April 2008 Resolved
Portable Halon 1211 Fire Extinguisher Appeared low on charge according to the attached gage.
Due 29 May 2008
Resolved 29 April 2008
Resolution: AFE Fire Protection Inc. representative stated that it is acceptable as long as the needle points in the green portion of the gage.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 April 2008 Resolved
Re-new/replace expired items in First Aid Kit.
Due 29 May 2008
Resolved 2 May 2008
Resolution: Corrected
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 April 2008 Resolved
COI not posted.
Due 29 May 2008
Resolved 29 April 2008
Resolution: Corrected
Documentation › Certificates/Documents › Stability Letter
Issued 29 April 2008 Resolved
Not posted.
Due 29 May 2008
Resolved 29 April 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 April 2008 Resolved
Secure loose wiring and remove wire nuts under bridge console.
Due 29 May 2008
Resolved 29 April 2008
Resolution: Corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 15 January 2008 Resolved
Renew STBD cutlas bearing.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Engineering › Pressure Vessel › Relief Valve
Issued 15 January 2008 Resolved
Properly insure and outfit both hot water heaters (fwd and eng. room) to insure it meets 46CFR 182.320.
Action required: 705 - Other - as specified
Due 15 February 2008
Resolved 14 February 2008
Stability › Watertight Integrity › General
Issued 15 January 2008 Resolved
Properly cap off thru bulkhead pipe in fwd bulkhead stbd side.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Electrical › Electric Supply System (service) › Cable
Issued 15 January 2008 Resolved
Properly dead-end or remove electrical wire stbd side fwd compartment stbd side.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 15 January 2008 Resolved
Remove water from bilge and clean for hull plate inspection.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 January 2008 Resolved
Install light cover in fwd compartment aft bulkhead.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Engineering › Sea-water System (primary cooling) › Valve
Issued 15 January 2008 Resolved
Make sea valves in fwd compartment open for inspection.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 15 January 2008 Resolved
Renew electrical junction box covers (2 ea) in galley.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 July 2007 Resolved
Properly Service fixed CO2 system to engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2007
Electrical › Electric Generation Source (service) › Power Requirement
Issued 26 July 2007 Resolved
Properly mount port generator electrical start box. Vessel is restricted from using port generator with passengers on board until properly mounted and inspected by an attending Marine Inspector.
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 29 August 2007
Electrical › Electric Supply System (service) › Cable
Issued 26 July 2007 Resolved
Properly support or remove wire in engine room over port shaft.
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 29 August 2007
Electrical › Electric Supply System (service) › Cable
Issued 26 July 2007 Resolved
Properly wire fuel tank gauges IAW 46CFR 183.340 (wire nuts exposed).
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 29 August 2007
Electrical › Electric Supply System (service) › Cable
Issued 26 July 2007 Resolved
Properly dead-end or remove wires out of breaker box inside storage linen locker.
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 29 August 2007
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 26 July 2007 Resolved
Install latch to secure breaker box fwd stbd side.
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 29 August 2007
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 26 July 2007 Resolved
Properly mount FWD compressor for head.
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 29 August 2007
Documentation › Logs/Records › Logbook (official)
Issued 26 July 2007 Resolved
Provide current training log book IAW 46CFR 185.420.
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 29 August 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 July 2007 Resolved
Mark life jacket storage IAW 46CFR 185.604.
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 29 August 2007
Lifesaving › Lifefloat › Painter
Issued 26 July 2007 Resolved
Install sea painter line on STBD life float IAW 46CFR 180.175.
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 29 August 2007
Lifesaving › Lifefloat › Markings
Issued 26 July 2007 Resolved
Properly mark life floats and paddles with vessels name IAW 46CFR 185.604.
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 29 August 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 July 2007 Resolved
Provide current Navigation Publications IAW 46CFR 184.42.
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 29 August 2007
Stability › Intact Righting Energy › General
Issued 26 July 2007 Resolved
Properly mark upper deck for maximum number of passengers IAW 185.602(g).
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 29 August 2007
Documentation › Certificates/Documents › Stability Letter
Issued 26 July 2007 Resolved
Post stability letter IAW 46CFR 176.306.
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 29 August 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 May 2006 Resolved
Properly label child lifejacket storage.
Action required: 705 - Other - as specified
Resolved 1 May 2006
Lifesaving › Lifefloat › Markings
Issued 1 May 2006 Resolved
Properly label life floats with vessels name.
Action required: 705 - Other - as specified
Resolved 1 May 2006
Fire Fighting › Fire Pumps › Pressure
Issued 1 May 2006 Resolved
Prove proper operation of fire pump.
Action required: 705 - Other - as specified
Resolved 1 May 2006
Resolution: Strainer was clogged. After cleaning strainer, fire pump worked correctly.
Engineering › Compressed Air System (control) › Compressor
Issued 15 February 2006 Resolved
Provide proof that air compressor receiver and relief valve(s) meets the requirements of 46CFR54.01-05(c)(4)
Due 15 March 2006
Resolved 1 May 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 February 2006 Resolved
Install Conduit Plug in electrical outlet in engine room aft and amidships In Accordance With 46 CFR 183.200 (c)
Due 6 March 2006
Resolved 1 May 2006
Engineering › Steering Gear System › Hydraulic Hose
Issued 6 February 2006 Resolved
Renew Hydraulic line for autopilot system on Port engine IAW 46 CFR 182.720 (e)
Due 6 March 2006
Resolved 1 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 February 2006 Resolved
Install new wire connectors in fwd compartment IAW 46 CFR 183.340 (i) (2).
Due 6 March 2006
Resolved 1 May 2006
Engineering › Compressed Air System (control) › Compressor
Issued 6 February 2006 Resolved
Provide plans to permanatly mount air compressor for toilet system, prior to carrying passengers for hire.
Due 6 March 2006
Resolved 15 February 2006
Electrical › Electric Supply System (service) › Cable
Issued 6 February 2006 Resolved
Renew welding cable wire for breaker box #1 with wire that meets 46 CFR 183.340 (d) (2).
Due 6 March 2006
Resolved 1 May 2006
Stability › Watertight Integrity › General
Issued 6 February 2006 Resolved
Make fwd engine room bulkhead watertight in vicinity of Port engine V-drive approx 6 inches up from the bilge.
Due 6 March 2006
Resolved 1 May 2006
Fire Fighting › Fire Pumps › Suction Valve
Issued 6 December 2004 Resolved
Eliminate water leakage from bonnet of fire pump thru hull valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2005
Resolved 9 December 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 December 2004 Resolved
Perform 7 month overdue annual servicing on portable dry chem fire extingusher in main deck accomodation space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2005
Resolved 9 December 2004
Engineering › Bilge Water Management System › Pump
Issued 6 December 2004 Resolved
Prove proper operation of installed power bilge pump. Vessel restricted to not more than 49 passengers until corrected.
Due 6 January 2005
Resolved 1 May 2006
Engineering › Fuel Oil Service System › Valve, Control
Issued 6 December 2004 Resolved
Re-attach supporting hangar for emergency fuel cut out valve cableway.
Due 6 January 2005
Resolved 9 December 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 December 2004 Resolved
Install lagging on port main diesel engine exhaust.
Due 6 January 2005
Resolved 6 February 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 December 2004 Resolved
Properly secure CO2 bottle for beverage dispensing system.
Due 6 January 2005
Resolved 9 December 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 6 December 2004 Resolved
Make wire penetration of collision blkhd stbd side watertight.
Due 6 January 2005
Resolved 6 February 2006
Lifesaving › Buoyant Apparatus › Painter
Issued 6 December 2004 Resolved
Properly attach both lifefloats in tandem in accordance with 46 CFR 180.137
Due 6 January 2005
Resolved 1 May 2006
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 6 December 2004 Resolved
Eliminate excessive water leakage from stbd shaft log. Test underway.
Due 6 January 2005
Resolved 1 May 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 December 2004 Resolved
Repair damaged handrail stbd side amidships.
Due 6 January 2005
Resolved 6 February 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 6 December 2004 Resolved
Provide means to attach engine room vent cover in case of fire.
Due 6 January 2005
Resolved 9 December 2004
Stability › Watertight Integrity › Deadlight Cover
Issued 6 December 2004 Resolved
Repair port light covers below main deck so they can fully close in way of fore peak storage space, galley, and port side storage room fwd of engine room.
Due 6 January 2005
Resolved 6 February 2006
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 December 2004 Resolved
Provide onboard updated coast pilot and light list.
Due 6 January 2005
Resolved 9 December 2004
Documentation › Logs/Records › Logbook (official)
Issued 6 December 2004 Resolved
Create lifesaving maintenance log to properly document required inspections and maintenace in accordance with 46 CFR 185.702
Due 6 January 2005
Resolved 9 December 2004
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 6 December 2004 Resolved
Renew retro-reflective tape on 11 adult life jackets.
Due 6 December 2004
Resolved 6 December 2004
Resolution: Corrected on spot.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 December 2004 Resolved
Properly mount and provide cover for light fixture in galley pantry.
Due 6 December 2004
Resolved 6 December 2004
Resolution: Corrected on spot.
Lifesaving › Buoyant Apparatus › Painter
Issued 6 December 2004 Resolved
Properly attach sea painter to painter attachment fitting or around the body of the lifefloat as required by 46 CFR 180.137
Due 6 December 2004
Resolved 6 December 2004
Resolution: Corrected on spot.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 December 2004 Resolved
Tighten crimp for wire supplying power to light fixture over stbd MDE.
Due 6 December 2004
Resolved 6 December 2004
Resolution: Corrected on spot.
Engineering › Bilge Water Management System › Not Operational
Issued 6 December 2004 Resolved
Prove proper operation of aft bilge high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2004
Resolved 6 December 2004
Resolution: Wires to alarm were corroded and repaired on spot.
Construction/Loadline › Hull
Issued 3 February 2004 Resolved
Make available for inspection the interior hull area in way of galley. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Resolved 8 March 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 3 February 2004 Resolved
Provide and install machinery guards on both main diesel engines and ships service generator. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 3 March 2004
Resolved 8 March 2004
Electrical › Electric Supply System (service)
Issued 30 January 2004 Resolved
Remove or enclose in a junction box all wire nut connections under bridge console and above forward bilge pump.
Action required: 705 - Other - as specified
Due 14 February 2004
Resolved 8 March 2004
Lifesaving › Rigid Liferafts
Issued 30 January 2004 Resolved
Replace lens on life float light that appears to be opaque.
Action required: 705 - Other - as specified
Due 14 February 2004
Resolved 8 March 2004
Lifesaving › Buoyant Apparatus
Issued 30 January 2004 Resolved
Restencil name of vessel on life floats.
Action required: 705 - Other - as specified
Due 14 February 2004
Resolved 8 March 2004
Lifesaving › Buoyant Apparatus
Issued 30 January 2004 Resolved
Make life float covers float free from life floats.
Action required: 705 - Other - as specified
Due 14 February 2004
Resolved 19 April 2004
Resolution: Life float cover only covers the top float and this configuration has been allowed on other vessels.
Construction/Loadline › Hull
Issued 30 January 2004 Resolved
Make forepeak available for inspection at dry dock.
Action required: 705 - Other - as specified
Due 17 February 2004
Resolved 20 February 2004
Construction/Loadline › Penetrations
Issued 30 January 2004 Resolved
Make engine room emergency hatch watertight.
Action required: 705 - Other - as specified
Due 17 February 2004
Resolved 20 February 2004
Engineering › Bilge Water Management System
Issued 30 January 2004 Resolved
Prove proper operation of fixed bilge system in forward compartment. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 17 February 2004
Resolved 8 March 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 17 July 2002 Resolved
Install machinery guards over rotating machinery on both engines and port generator. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 8 March 2004
Construction/Loadline › Structures
Issued 17 July 2002 Resolved
Replace as new two cracked windows located on the main deck on the bow and stbd side fwd. LEGACY COMPONENT DESC: Windows
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 22 August 2002
Resolution: Cracked windows were replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 July 2002 Resolved
Properly cap all dead end wiring.
Due 17 July 2002
Resolved 17 July 2002
Stability › Watertight Integrity
Issued 17 July 2002 Resolved
Ensure hatch leading to the forepeak has a connecting device attached. LEGACY COMPONENT DESC: Hatch
Due 17 July 2002
Resolved 17 July 2002
Engineering › Bilge Water Management System
Issued 17 July 2002 Resolved
Fix bilge high level alarm visual indicator on bridge. LEGACY COMPONENT DESC: Visual alarm
Due 17 July 2002
Resolved 17 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 17 July 2002 Resolved
Properly mark engine room escape hatch. LEGACY COMPONENT DESC: Means of Escape
Due 17 July 2002
Resolved 17 July 2002
Engineering › Generator (propulsion-electric)
Issued 24 January 2002 Resolved
Replace cracked muffler on port generator.
Condition: Placed in Improper Service
Due 24 February 2002
Resolved 1 March 2002
Engineering › Fuel Oil Service System
Issued 24 January 2002 Resolved
Replace cracked hoses & slip fittings on port and stbd engines. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 24 February 2002
Resolved 1 March 2002
Construction/Loadline › Hull
Issued 24 January 2002 Resolved
Repair pinhole on port side of vessel. LEGACY COMPONENT DESC: Hull Plating
Due 24 February 2002
Resolved 1 March 2002
Stability › Watertight Integrity
Issued 24 January 2002 Resolved
Create handle on cover leading to collision bulkhead.
Condition: Improper Installation
Due 24 February 2002
Resolved 30 January 2002
Electrical › Electrical Distribution System (service)
Issued 24 January 2002 Resolved
Remove unauthorized electrical box in Galley. LEGACY COMPONENT DESC: Junction Box
Due 24 February 2002
Resolved 30 January 2002
Stability › Watertight Integrity
Issued 24 January 2002 Resolved
Replace all cracked port lights.
Due 24 February 2002
Resolved 1 March 2002
Resolution: All Port lights renewed with lexan.
Stability › Watertight Integrity
Issued 24 January 2002 Resolved
Gasket leading into E/R on door needs to be replaced.
Condition: Unknown
Due 24 February 2002
Resolved 3 April 2002
Resolution: Added additional insulation around dogging ramp, when door was closed no light was visable through the door.
Stability › Watertight Integrity
Issued 24 January 2002 Resolved
Fix inoperable dead light covers.
Due 24 February 2002
Resolved 1 March 2002
Stability › Watertight Integrity
Issued 24 January 2002 Resolved
Make collision bulkhead watertight.
Due 24 February 2002
Resolved 1 March 2002
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 January 2002 Resolved
Remove electrical outlet in E/R above port engine.
Condition: Placed in Improper Service
Due 24 February 2002
Resolved 30 January 2002
Engineering › Generator (propulsion-electric)
Issued 24 January 2002 Resolved
Secure loose wires above stbd generator. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 24 February 2002
Resolved 30 January 2002
Stability › Watertight Integrity
Issued 23 January 2002 Resolved
Make all subdivision bulkheads watertight.
Due 24 February 2002
Resolved 1 March 2002
Stability › Watertight Integrity
Issued 23 January 2002 Resolved
Replace as new handle on E/R door and cracked dogging ramp.
Condition: Unknown
Due 24 February 2002
Resolved 17 July 2002
Resolution: New dogging ramp installed and verified.
Documentation
Issued 11 July 2000 Resolved
PROVIDE A VALID FCC RADIOTELEPHONY CERTIFICATE AS PER 47 CFR 80.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Navigation
Issued 11 July 2000 Resolved
POST AN EMERGENCY BRAODCAST PLACARD IN ACCORDNACE WITH 46 CFR 184.506.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Navigation
Issued 11 July 2000 Resolved
PROVIDE A CURRENT COMPASS DEVIATION CARD.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Accommodation/Occupational Safety
Issued 11 July 2000 Resolved
POST AN EMERGENCY PROCEDURE LIST ON THE VESSEL IN ACCORDANCE WITH 46 CFR 185.510.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Lifesaving
Issued 11 July 2000 Resolved
PROVIDE PROPER RETRO-REFLECTIVE TAPE ON ALL LIFERINGS.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Engineering
Issued 27 May 2000 Resolved
MAKE PERMANENT REPAIRS TO U-JOINT SHAFT ON PORT ENGINE.
Condition: Unknown
Due 27 May 2000
Resolved 27 May 2000
Construction/Loadline
Issued 5 November 1999 Resolved
PROVIDE REPAIR PROPOSAL AND PROCEDURES FOR REPAIR OF PITTING IN HULL BOTTOMPLATE PRIOR TO NEXT DRY DOCK. NEXT DRY DOCK DATE IS 03 JAN 99.
Condition: Unknown
Due 5 November 1999
Resolved 5 November 1999
Construction/Loadline
Issued 5 November 1999 Resolved
INSTALL INDICATOR LIGHTS AT OPERATORS STATION TO INDICATE WHETHER ENGINE ROOM WATER TIGHT DOOR IS OPEN OR CLOSED, I.A.W. 46 CFR 179.330(b).
Condition: Unknown
Due 5 November 1999
Resolved 5 November 1999
Construction/Loadline
Issued 5 November 1999 Resolved
REMOVE DOUBLER PLATE LOCATED PORT SIDE, FWD BLKHD OF ENGINE ROOM, 2ND LONGITUDINAL OUTBOARD OF KEEL TO PORT ENGINE BED, EXTENDING 30"AFT. PROVIDE REPAIR PROPOSAL TO CROP AND RENEW PITTED BOTTOM PLATE IN SAME AREA.
Condition: Unknown
Due 5 November 1999
Resolved 5 November 1999
Construction/Loadline
Issued 5 November 1999 Resolved
PROVE WATERTIGHT INTEGRITY OF CHAIN LOCKER ACCESS HATCH.
Condition: Unknown
Due 5 November 1999
Resolved 5 November 1999
Fire Fighting
Issued 10 October 1996 Resolved
PROVIDE SERVICING REPORT FOR FIXED EXTINGUISHING SYSTEM INCLUDING MANUAL & AUTOMATIC OPERATION.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Construction/Loadline
Issued 10 October 1996 Resolved
PROVIDE GAUGING REPORT FOR THE VESSEL. TAKE AT LEAST 5 READINGS OF EACH SHELL OR BULKHEAD PLATE.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Construction/Loadline
Issued 10 October 1996 Resolved
PROPERLY SEAL DECK ABOVE ENGINEROOM AFT OF THE EMERGENCY ESCAPE; HOSE TEST TO ENSURE WEATHERTIGHTNESS.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Construction/Loadline
Issued 10 October 1996 Resolved
PROVIDE 698 SQUARE INCHES OF ADDITIONAL FREEING PORT AREA (VSL NEEDS 1,060 SQ IN TOTAL FOR PRESENT ROUTE AND HAS 362 SQ IN).
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Construction/Loadline
Issued 10 October 1996 Resolved
PROPERLY CAP OFF BILGE SYSTEM FLUSH ACCESS OPENING.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Lifesaving
Issued 10 October 1996 Resolved
PROVIDE PLACARDS FOR PFD STOWAGE AREAS WHICH PROPERLY REFLECT NUMBER OF PFD'S STOWED.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Documentation
Issued 10 October 1996 Resolved
PROVIDE VALID RADIO OPERATOR'S PERMIT FOR THE VESSEL MASTER.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Documentation
Issued 10 October 1996 Resolved
PROVIDE RADIO STATION LICENSE UPDATED WITH NEW VESSEL NAME AND OWNER INFORMATION.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Electrical
Issued 10 October 1996 Resolved
UPDATE ELECTRICAL PLAN TO INCLUDE AIR COMPRESSOR INSTALLATIONS (DIVE AIR COMPRESSOR AND 6-GAL MSD COMPRESSOR UPGRADE) AND SUBMIT TO OCMI FOR REVIEW.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Construction/Loadline
Issued 10 May 1994 Resolved
RESTORE FOREPEAK HATCH DOGS TO NORMAL OPERATION - ALLOWING HATCH TO BE SECURED IN PLACE.
Condition: Unknown
Due 24 May 1994
Resolved 16 July 1994
Construction/Loadline
Issued 10 May 1994 Resolved
PROVIDE ADDITIONAL FREEING PORT AREA - 398 AVAILABLE, 1292 REQUIRED FOR PRESENT ROUTE.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Construction/Loadline
Issued 23 March 1994 Resolved
CLEAN AND TREAT FURRING TO WOOD IN FIRST CABIN OVERHEAD ON PORT SIDE.
Condition: Unknown
Due 6 April 1994
Resolved 25 April 1994
Lifesaving
Issued 23 March 1994 Resolved
REMARK PADDLES IN LIFEFLOATS TO REFLECT ENTIRE NAME.
Condition: Unknown
Due 6 April 1994
Resolved 18 April 1994
Lifesaving
Issued 23 March 1994 Resolved
REPLACE CRACKED GLASS PAIN LOCATED IN LOUNGE AREA, FORWARD ON STARBOARD SIDE.
Condition: Unknown
Due 6 April 1994
Resolved 18 April 1994
Electrical
Issued 23 March 1994 Resolved
PROVE OPERATION OF PORT GENERATOR.
Condition: Unknown
Due 6 April 1994
Resolved 25 April 1994
Engineering
Issued 23 March 1994 Resolved
REPAIR OIL TEMPERATURE GAUGE ON PORT SIDE ENGINE.
Condition: Unknown
Due 6 April 1994
Resolved 25 April 1994
Engineering
Issued 23 March 1994 Resolved
PROVIDE ADEQUATE HOUSEKEEPING FOR ENGINE ROOM.
Condition: Unknown
Due 6 April 1994
Resolved 25 April 1994
Lifesaving
Issued 23 March 1994 Resolved
PROVIDE ADDITIONAL DOG TO EMERGENCY ESCAPE HATCH FROM ENGINE ROOM AND REPLACE GASKET.
Condition: Unknown
Due 6 April 1994
Resolved 25 April 1994
Construction/Loadline
Issued 23 March 1994 Resolved
REPAIR CRACKED WELD FORWARD OF COLLISION BULKHEAD ON PORT SIDE ABOVE WATER LINE.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Engineering
Issued 23 March 1994 Resolved
REMOVE ALL EXCESS PIPING NOT CURRENTLY IN SERVICE IN ENGINE ROOM.
Condition: Unknown
Due 6 April 1994
Resolved 25 April 1994
Lifesaving
Issued 23 March 1994 Resolved
REPAIR/REMOVE WATER HEATER THAT IS LEAKING LOCATED ON STARBOARD SIDE.
Condition: Unknown
Due 6 April 1994
Resolved 18 April 1994
Navigation
Issued 18 March 1993 Resolved
PAINT BLACK, BOTH PORT AND STARBOARD NAVIGATION LIGHT SCREENS.
Condition: Unknown
Due 18 April 1993
Resolved 13 April 1993
Lifesaving
Issued 18 March 1993 Resolved
PROVIDE A LIFE PRESERVER STOWAGE COMPARTMENT ON UPPER DECK FOR MINIMUM OF 20 LIFE PRESERVERS ON THE UPPER DECK.
Condition: Unknown
Due 18 April 1993
Resolved 13 April 1993
Accommodation/Occupational Safety
Issued 18 March 1993 Resolved
REPLACE CRACKED GLASS PAIN LOCATED IN LOUNGE AREA, FORWARD STBD SIDE.
Condition: Unknown
Due 18 April 1993
Resolved 13 April 1993
Lifesaving
Issued 18 March 1993 Resolved
VESSEL HAS INSUFFICIENT LIFE FLOAT CAPACITY FOR 110 PASSENGERS ON LAKES BAYUS AND SOUNDS ROUTE. NEED LIFE FLOAT OR B/A WITH CAPACITY FOR 9 PERSONS. VESSEL RESTRICTED TO 80 TOTAL PERSONS UNTIL THIS ITEM SATISIFIED.
Condition: Unknown
Due 18 April 1993
Resolved 13 April 1993
Lifesaving
Issued 23 September 1992 Resolved
INSTALL EPIRB SO IT WILL FLOAT FREE IF VESSEL SINKS
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992
Lifesaving
Issued 23 September 1992 Resolved
PROVIDE CLASS "A" EPIRB IN ACCORDANCE WITH 46 CFR 180.40-1
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992
Construction/Loadline
Issued 22 May 1992 Resolved
REPAIR/REPLACE MISSING STANCHIONS ON FWD 3RD OF VESSEL.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Engineering
Issued 22 May 1992 Resolved
HAVE MARINE INSPECTOR INSPECT "V" DRIVE/SHAFT FIT-UP, RUDDER INSTALLATION, AND PROP INSTALLATION PRIOR TO PUTTING THE VESSEL BACK INTO THE WATER.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Unknown
Issued 22 May 1992 Resolved
CONDUCT FULL ENGINE AND STEERING TESTS IN THE PRESENCE OF A MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS FOR HIRE. TESTS WILL BE UNDERWAY.
Condition: Unknown
Due 31 August 1992
Resolved 31 August 1992
Lifesaving
Issued 4 April 1991 Resolved
ATTACH FWD 12 PERSON LIFEFLOAT WEAK LINK TO VESSEL.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Lifesaving
Issued 4 April 1991 Resolved
PROVIDE MOUNT FOR EPIRB OUTSIDE WHEELHOUSE.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Lifesaving
Issued 4 April 1991 Resolved
LABEL ALL LIFE JACKET STOWAGE AREAS WITH THE NUMBER OF LIFE JACKETS INSIDE.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Documentation
Issued 4 April 1991 Resolved
PROVIDE DOCUMENTATION OF ENROLLMENT INTO A DRUG TESTING PROGRAM.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Deck/Cargo
Issued 4 April 1991 Resolved
PROVE PROPER OPERATION OF ANCHOR WINDLASS.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Electrical
Issued 4 April 1991 Resolved
PROVE PROPER OPERATION OF BELOW DECK EMERGENGY LIGHTING. NO PASSENGERS ALLOWED BELOW DECK UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Lifesaving
Issued 4 April 1991 Resolved
STENCIL ALL LIFESAVING GEAR WITH VESSEL'S DOCUMENTED NAME.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Lifesaving
Issued 4 April 1991 Resolved
LABEL LIFEFLOAT COVER ON BRIDGE DECK WITH THE NUMBER OF LIFE JACKETS_x001C_ STOWED IN THE LIFEFLOATS
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Lifesaving
Issued 4 April 1991 Resolved
RELOCATE 24 ADULT LIFE JACKETS SO AS TO BE ACCESSIBLE TO PASSENGERS._x001C_ ( JACKETS WERE LOCATED ABOVE THE WHEELHOUSE )
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Accommodation/Occupational Safety
Issued 4 April 1991 Resolved
INSTALL RELIEF VALVES ON BOTH FRESH WATER TANKS. RELIEF VALVES SHALL BE SETTO RELIEVE AT LESS THAN 100 PSIG AND SHALL NOT BE LESS THAN 1" IN DIAMETER_x001C_UNLESS RELIEVING CAPACITY IS PROVEN SATISFACTORY TO THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Documentation
Issued 4 April 1991 Resolved
PRODUCE FCC RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Fire Fighting
Issued 4 April 1991 Resolved
PROVE PROPER OPERATION OF FIRE PUMP.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Fire Fighting
Issued 4 April 1991 Resolved
PROVIDE HAND FIRE PUMP WITH SUFFICIENT SUCTION TO BE OPERABLE FROM THE MAINDECK.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Documentation
Issued 4 April 1991 Resolved
PRODUCE DOCUMENTATION CERTIFICATE.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Fire Fighting
Issued 4 April 1991 Resolved
SERVICE FIXED CO2 SYSTEM FOR ENGINEROOM.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Lifesaving
Issued 4 April 1991 Resolved
PROVIDE 6 RED FLARES AND 3 ORANGE SMOKE SIGNALS.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Lifesaving
Issued 4 April 1991 Resolved
PROVIDE 8 ADULT LIFE JACKETS WITH WORKING WATERLIGHTS. VESSEL IS RESTRICTED TO 102 TOTAL PERSONS.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Construction/Loadline
Issued 30 November 1990 Resolved
CROP OUT AND RENEW TO SOLID WOOD BOTH AFT LOWER CORNERS OF PILOT HOUSE.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Electrical
Issued 30 November 1990 Resolved
REMOVE DEAD END WIRING IN WAY OF COLLISION BULKHEAD STBD SIDE.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Construction/Loadline
Issued 30 November 1990 Resolved
CROP OUT TO SOLID WOOD AND RENEW ROTTED HALF ROUND TRIM AND AFFECTED DECK AREA ON 01 DECK ON BOTH SIDES.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Construction/Loadline
Issued 8 February 1990 Resolved
REPLACE CRACKED WINDOWS, PORT SIDE FORWARD AND PORT SIDE AFT.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Electrical
Issued 8 February 1990 Resolved
REPLACE OR BLANK OFF MOORING LIGHTS.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Electrical
Issued 8 February 1990 Resolved
REMOVE DEAD-END WIRING FOR MOORING LIGHTS AT COLLISION BULKHEAD.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Construction/Loadline
Issued 6 July 1989 Resolved
PRIOR TO VESSEL'S SCHEDULED DRYDOCKING IN NOV 89, PROVIDE REPAIR PROCEDURE FOR LOCALIZED BOTTOM SHELL PITTING FOR REVIEW AND APPROVAL. APPROVED REPAIRS TO BE CARRIED OUT DURING THE DRYDOCK AVAILABILITY, NO LATER THAN 30NOV89.
Condition: Unknown
Due 6 July 1989
Resolved 6 July 1989
Lifesaving
Issued 3 May 1989 Resolved
RENEW EPIRB BATTERY-VESSEL RESTRICTED TO 20 MILES FRON HARBOR OF SAFE REFUGE UNTIL CLEARED
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Engineering
Issued 3 May 1989 Resolved
ADJUST FUEL SHUTOFF SYSTEM SO THAT ALL VALVES (4) ARE FULLY CLOSED WHEN WIRE IS PULLED TIGHT.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Engineering
Issued 3 May 1989 Resolved
REMOVE 2 AIR RECEIVERS (FWD COMPT AND BRIDGE) IF REQUIRED RENEW WITH UL APPROVED RECEIVERS FITTED WITH RELIEF VALVES.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Construction/Loadline
Issued 3 May 1989 Resolved
PROVIDE PLANS WITH ORIGINAL HULL THICKNESS. ALSO PROVIDE A PROPOSAL FOR FURTHER SURVEY OF INTERNAL HULL CONDITION AND A REPAIR PROPOSAL FOR EXIST- ING PITTED CONDITION.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Engineering
Issued 2 June 1987 Resolved
REPLACE NON-METALLIC BILGE PIPING WITH METALLIC PIPING THROUGHOUT VESSEL.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Engineering
Issued 6 May 1987 Resolved
MAKE PERMANENT REPAIRS TOELECTRIC BILGE PUMP IN ENGINEROOM.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Engineering
Issued 6 May 1987 Resolved
INSTALL FLAME SHIELD TO RACOR FUEL FILTER ON STBD MAIN ENGINE.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Fire Fighting
Issued 6 May 1987 Resolved
INSTALL NOZZLE TO GARDEN HOSE (FIRE HOSE) OF BRONZE OR GOOD GRADE METAL.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Accommodation/Occupational Safety
Issued 20 May 1986 Resolved
PROVIDE MEANS OF LOCKING CLOSED MSD OVBD DSCH VALVE.
Condition: Unknown
Due 20 May 1986
Resolved 20 May 1986
Construction/Loadline
Issued 17 May 1985 Resolved
INSTALL RETAINER CHAIN ON FOREPEAK HATCH COVER.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Engineering
Issued 17 May 1985 Resolved
INSTALL FLAME SHIELDS ON RACOR FUEL FILTERS IN ENGINE ROOM.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Navigation
Issued 17 May 1985 Resolved
LABEL E.P.I.R.B. WITH VESSEL NAME.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Unknown
Issued 17 May 1985 Resolved
REPLACE PORT FORWARD WINDOW IN MAINDECK CABIN.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Fire Fighting
Issued 17 May 1985 Resolved
LABEL AREA ADJACENT TO CO2 PULL: "IN CASE OF FIRE IN ENGINE ROOM, SECURE HATCHES AND VENTILATION".
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985

Casualty record · 3

11 October 2014Routine · role: Involved in a Marine Casualty · activity 5008561
25 March 2017Routine · role: Acknowledged Pollution Source · activity 6112257
21 July 2018Routine · role: Involved in a Marine Casualty · activity 6512161
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.