MAURY USCG vessel records Sign in
← All vessels

MISS ISLAMORADA

MISS ISLAMORADA is a 1969 passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1984, most recently in November 2025, along with 117 deficiencies, 1 operational control and 1 casualty investigation in 2022.

Records from 1984 to 2025. Most recent: inspection, 25 November 2025.

Built
1969
Last inspected
25 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD4180
Flag
UNITED STATES
367141320
Maury page id
psix-46121

Inspections, by type

…with no type recorded5
Years with a record 39 calendar years (1984–2025)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.1 ft × 18.0 ft × 4.3 ft
Registered tonnagegross 43 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMIAMI BCH YACHT CORP · MIAMI BEACH, FL, UNITED STATES · built 1969
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portISLAMORADA, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 18 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD4180MMSI 367141320 · active · compulsorily equipped · granted 16 July 2016, expires 23 September 2026
WDC8001MMSI 367080150 · expired · compulsorily equipped · granted 7 December 2005, cancelled 6 February 2016 · licensed under a name not among this hull’s recorded names (not shown)
WY5732MMSI not assigned · expired · compulsorily equipped · granted 18 March 1997, cancelled 18 March 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 66

25 November 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8273535
4 September 2025 Drydock Exam · Deficiency Check · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8090146
5 September 2024 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7967692
27 September 2023 Drydock Exam · Annual Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7808158
7 September 2022 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7553558
17 March 2022 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7413612
23 August 2021 Deficiency Check · DAPI Audit · Internal Structural Exam · COI Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7294120
27 October 2020 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7085955
29 September 2020 DAPI Audit · Internal Structural Exam · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7067903
2 December 2019 Administrative Inspection · Deficiency Check · Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6865822
19 September 2019 Hull Examination · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6815911
5 September 2018 DAPI Audit · Internal Structural Exam · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6658280
23 January 2018 Administrative Inspection · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6531873
25 October 2017 Hull Examination · In-Service Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294976
25 September 2017 Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294195
7 September 2016 DAPI Audit · Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5995588
6 November 2015 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5758217
18 September 2015 Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5233981
19 September 2011 Deficiency Check · COI Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4149019
2 December 2010 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3905970
11 November 2010 Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 3891952
3 December 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3644675
31 October 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3372661
13 November 2007 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3097392
25 September 2007 Deficiency Check · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3065544
26 September 2006 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2786302
3 January 2006 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2559611
8 December 2005 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2542637
29 September 2005 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2503589
10 November 2004 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2232455
26 May 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2110413
2 December 2003 Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1941351
25 September 2003 MARPOL Annex V Examination · Deficiency Check · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1874819
18 September 2002 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1663392
13 February 2002 Hull Examination · Damage Survey · Examination of Repairs
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1493332
27 September 2001 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1426669
5 October 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1415473
29 September 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1372767
2 December 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1437491
1 October 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 802171
15 October 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1116594
2 October 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1109674
11 December 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1091392
16 October 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 838530
2 November 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1190432
16 October 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 880968
2 October 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 877441
5 January 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1171870
23 November 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1172811
10 November 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1137910
27 October 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1138350
22 April 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1146579
6 October 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1268383
20 May 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1258459
30 October 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1261407
18 October 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1250989
16 October 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 915073
24 April 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1221733
6 October 1989 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 910414
19 October 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1196537
5 October 1988 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 887126
14 October 1987 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1018002
23 April 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1316558
15 October 1986 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1320112
26 November 1985 Re-Inspection · Credit Drydock
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1297927
5 December 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1284237

Deficiency record · 117

07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 November 2025 Resolved
Fire stop needs to be added to the FWD and Engine compartment bulkheads.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 November 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 November 2025 Resolved
Emergency procedures need to be posted on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 November 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 September 2022 Resolved
Supervisor is missing the 1 hour EAP training. Must show proof of 1 hour training for EAP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 8 September 2022
Resolution: Completed the 1 hr training as required
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 September 2021 Resolved
Life ring buoy throw line and floating light line were rotted. Must replace 60 foot throw line and 3-6 foot floating light line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 5 October 2021
Resolution: Replaced line with new.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 September 2021 Resolved
#4 high water alarm light was not working. Light was already on order.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 5 October 2021
Resolution: replaced all wire connections on both alarm and switch, Test SAT
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 September 2021 Resolved
Vessel had several buckets onboard, but none labeled fire buckets with lanyards attached. Must have 3 buckets atleast 2.5 gallons each labeled fire buckets and have lanyards attached.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 7 October 2021
Resolution: Labeled 3 buckets and attached lanyards as required. All SAT
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 29 September 2020 Resolved
Fireboy system tested, engines shut down but was able to start and stay running without hitting the overide switch. Fix and have CG inspector test prior to carrying passengers. 46 CFR 181.420
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2020
Resolved 5 October 2020
Resolution: Re wired system, tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 September 2020 Resolved
Both 20 person life floats do not have nets. Both life floats must have nets that suspends 36 inches below float. 46 CFR 180.200
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2020
Resolved 27 October 2020
Resolution: installed two new nets, all SAT
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 September 2020 Resolved
Update Nav pubs. Missing Nav Rules, Chart few yrs old with no chart corrections, Coast Pilot is 2019 version, and missing tide table. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2020
Resolved 27 October 2020
Resolution: Printed out all new NAV pubs for 2020 and bought new NOAA chart, all SAT
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 September 2020 Resolved
First aid kit has expired items. Update first Aid kit. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2020
Resolved 27 October 2020
Resolution: replaced all expired meds, all SAT
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 September 2020 Resolved
No record of crew training as required in 46 CFR 185.420 Fire and Man overboard drills are not being logged correctly. Went over with Captain on how to log training and drills. 46 CFR 185.420 46 CFR 185.520 46 CFR 185.524
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 27 October 2020
Resolution: Made new training logs
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 September 2020 Resolved
Retro tape on Life Ring was fading and starting to peel off. Replace faded/peeling retro with new. 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2020
Resolved 27 October 2020
Resolution: Retro on life ring was replaced with new, all SAT
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 September 2020 Resolved
Vertical beam in hold #1 next to scuttle was not attached to frame in overhead. Add bracket to secure beam to frame. 46 CFR 176.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2020
Resolved 27 October 2020
Resolution: Added two new brackets, one on each side of frame. All SAT
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 29 September 2020 Resolved
No one on board or with company had proof of current in CPR. One deckhand had an expired card from 2019. 50 percent of crew must be certified in CPR. NVIC 1-91
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2020
Resolved 29 September 2020
Resolution: 2 deckhands onboard re took online course/test. Showed certificate for current in CPR for next 2 yrs
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 December 2019 Resolved
High water alarms are inoperable. Repair/replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2019
Resolution: High water visual and audible alarm was repaired by replacing the fuse for the corresponding system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 December 2019 Resolved
8 adult life jackets are wasted. Renew prior to caring more than 43 passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2019
Resolution: 8 adult life jackets were purchased, properly built up to specifications, and put into service.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 December 2019 Resolved
Anchor light is extinguished. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2019
Resolution: Anchor lightbulb was replaced.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 2 December 2019 Resolved
Radio must be linked to GPS and have MMSI# input.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2019
Resolution: New radio was replaced and MMSI# and GPS information was inputted into the unit.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 December 2019 Resolved
Remount port life float strobe bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2019
Resolution: A new life float strobe bracket was purchased for the port float and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 December 2019 Resolved
Mark life float bottoms with name, total numbers of passengers and new reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2019
Resolution: Life floats were correctly marked with name, total numbers of passengers and new reflective tape on both sides.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 September 2018 Resolved
Bilge high level light is extinguished. Repair/renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2018
Resolution: Light renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 September 2018 Resolved
Alcohol test strips are expired. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2018
Resolution: New kits were provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 September 2018 Resolved
Several life jackets had holes from rats. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2018
Resolution: Jackets were replaced.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 January 2018 Resolved
EPIRB Hydrostatic release is expired. Renew.
Action required: 10 - Deficiency Rectified
Resolved 6 February 2018
Resolution: New Haydrostatic release was installed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 23 January 2018 Resolved
Vessel is required to have a sound producing device. Horn is currently inoperable. Repair/renew.
Action required: 10 - Deficiency Rectified
Resolved 6 February 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 January 2018 Resolved
Preengineerd system override function is currently inoperable. Repair/renew.
Action required: 10 - Deficiency Rectified
Resolved 6 February 2018
Resolution: Preengineered system was repaired, and tested all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 January 2018 Resolved
Life float painter basket is broken and will not allow the painter line to discharge freely. Renew or repair.
Action required: 10 - Deficiency Rectified
Resolved 6 February 2018
Resolution: New painter basket was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 January 2018 Resolved
Life floats must have paddles lashed to the float. Currently no paddles are available. Provide.
Action required: 10 - Deficiency Rectified
Resolved 6 February 2018
Resolution: Paddles were provided and lashed to the life float.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2018 Resolved
First aid kit is not an approved kit, and is missing the required contents. Provide approved kit.
Action required: 10 - Deficiency Rectified
Resolved 6 February 2018
Resolution: New approved first aid kit was provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 January 2018 Resolved
FCC safety certificate is expired. Provide new certificate.
Action required: 10 - Deficiency Rectified
Resolved 6 February 2018
Resolution: New FCC safety certificate was provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 23 January 2018 Resolved
Vessel captain must have an FCC operators permit.
Action required: 10 - Deficiency Rectified
Resolved 6 February 2018
Resolution: Captain attained an FCC operators permit.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 January 2018 Resolved
Vessel is required to have a log to track quarterly drills, and monthly epirb testing. Provide log.
Action required: 10 - Deficiency Rectified
Resolved 6 February 2018
Resolution: Log was provided and is being used.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 January 2018 Resolved
Vessel does not have a coast pilot, light list or tide table. Provide.
Action required: 10 - Deficiency Rectified
Resolved 6 February 2018
Resolution: New navigation publications were provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 September 2016 Resolved
Bulkhead penetrations for exhaust are leaking water.
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 21 September 2016
Resolution: Bulkhead penetrations were cleaned and new exhaust hoses were installed. Tested with no leaks.
Engineering › Fuel Oil Service System › Valve
Issued 7 September 2016 Resolved
Emergency fuel shut-off valves were not marked.
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 21 September 2016
Resolution: Valves were marked.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 7 September 2016 Resolved
RPM gauges only work intermittently.
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 21 September 2016
Resolution: new gauges were installed and tested, all sat.
Navigation › Piloting/Steering › Magnetic Compass
Issued 7 September 2016 Resolved
compass light is inop.
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 21 September 2016
Resolution: Light was repaired, and tested, all sat.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 September 2016 Resolved
Vessel does not have required navigation publications.
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 21 September 2016
Resolution: New pubs were purchased and placed on the vessel.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 September 2016 Resolved
Vessel does not have emergency broadcast placards near radios.
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 21 September 2016
Resolution: Instructions were posted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 September 2016 Resolved
First aid kit is incomplete.
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 21 September 2016
Resolution: New approved kit was placed into service.
Lifesaving › Lifefloat › Retroreflective Material
Issued 7 September 2016 Resolved
Retro material is missing or damaged.
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 21 September 2016
Resolution: Life float was repainted and new retro was installed all sat.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 7 September 2016 Resolved
Vessel does not have a waste management plan
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 21 September 2016
Resolution: Waste management plan was created and posted onboard.
Engineering › Steering Gear System › Rudder Stock
Issued 18 September 2015 Resolved
Provide servicing to STBD rudder as marked.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2015
Resolved 23 September 2015
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 18 September 2015 Resolved
Provide new cutlass bearings for both shafts.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 September 2015
Resolved 23 September 2015
Lifesaving › Buoyant Apparatus › Serviceable
Issued 19 September 2011 Resolved
Conduct buoyancy and watertight integrity test in accordance with 46 CFR 160.010-7 (e) and (f) on both buoyant apparatus in the presence of attending CG inspector. Buoyant apparatus were built in 1969 and appear to be in serviceable condition, but due to age these test need to be done.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2011
Resolution: Conducted satisfactory buoyancy and watertight integrity test. All sat.
Communications › Radio Communications › EPIRB
Issued 19 September 2011 Resolved
Properly install EPIRB hydrostatic release.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2011
Resolution: New hydrostatic release properly installed.
Navigation › Piloting/Steering › Marine Charts
Issued 19 September 2011 Resolved
Provide up to date nav chart, coast pilot, tide tables, and light list, for local operating area.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2011
Resolution: New nav pubs, light list and charts on board.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 September 2011 Resolved
Provide proof of proper inspection and testing of fixed fire fighting system, in accordance with NFPA 303.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2011
Resolved 25 October 2011
Resolution: Fire extinguisher inspection certificate provided.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 September 2011 Resolved
Vessel is undergoing maintenance, deck rails, seating, hatches, rub rails, and doors are removed for cosmetic repairs and painting. Vessel must complete satisfactory hull and COI inspection prior to going back into service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2011
Resolution: All repairs made satisfactory, vessel completed satisfactory Hull and COI inspections.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 September 2011 Resolved
Properly secure bench seats on both sides of forward cabin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2011
Resolved 1 November 2011
Resolution: Seats properly secured.
Engineering › Bilge Water Management System › Valve
Issued 2 December 2010 Resolved
Install positive closing valves, on all electric submersible bilge pump discharge hose's, as close to the hull as possible.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 December 2010
Resolution: New valves installed, all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 December 2010 Resolved
Remove all dead end wires, throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 December 2010
Resolution: Wires properly removed or insulated.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 December 2010 Resolved
Properly hang all wires and related electrical equipment, and properly insulate all wire connections, throughout the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 23 December 2010
Resolution: All wires and related equipment properly installed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 December 2010 Resolved
Float light batteries are weak, light flashing very slow, renew all batteries in float lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2010
Resolution: New batteries installed.
Lifesaving › Lifefloat › Serviceable
Issued 2 December 2010 Resolved
Port Lifefloat has small hole where lifeline clip has come unscrewed. Repair hole and install new screw, in lifeline retaining clip.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 December 2010
Resolution: Hole properly repaired.
Lifesaving › Lifefloat › Lifeline
Issued 2 December 2010 Resolved
Properly install lifeline on Starboard Lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 December 2010
Resolution: Lifeline properly installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 December 2010 Resolved
Port running light missing lens, may not operate vessel in restricted visibility until new lens is installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 December 2010
Resolution: New running light installed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 2 December 2010 Resolved
Vessel infested with roaches due to fish waste on deck and in storage cabinets. Fumigate vessel for bugs and clean up fish waste.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 December 2010
Resolution: Vessel fumigated, no live bugs found.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 2 December 2010 Resolved
MSD is not installed in accordance with approved CG standards. Install locking valves on overboard discharge lines from holding tanks. Replace all hose clamps on all hose's in sewage tank compartment.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 December 2010
Resolution: MSD properly installed, new pump out arrangements installed. New hose clamps installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 December 2010 Resolved
Replace hose clamps on port exhaust pipe in aft steering compartment, as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 December 2010
Resolution: New hose clamp installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 December 2010 Resolved
Provide exhaust lagging (insulation) on starboard engine outboard side where missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 December 2010
Resolution: Exhaust pipe wrapped with three layers of header tape. All sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 December 2010 Resolved
Provide guards for both MDE front crankshaft pulleys. Guard must be designed to protect against inadvertent contact with rotating machinery.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 December 2010
Resolution: New plywood barriers installed in front of both MDE''s. all sat.
Stability › Watertight Integrity › General
Issued 2 December 2010 Resolved
Plug/seal all holes in engine room bulkheads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 December 2010
Resolution: All holes sealed.
Communications › Audible Communications › Horn/Whistle
Issued 3 December 2009 Resolved
Horn doesn't work, provide satisfactory sound producing device.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2009
Resolved 3 December 2009
Resolution: Provided hand held air horn. All sat.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 3 December 2009 Resolved
Provide CG approved flame bowls (shields) for both Racor fuel filters.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 December 2009
Resolved 10 December 2009
Resolution: New flame bowls installed. All Sat.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 3 December 2009 Resolved
Port side engine room ventilation closure device not operational. Repair vent closure and demonstrate proper operation to attending CG inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2009
Resolved 4 January 2010
Resolution: Repairs made to closure device. All sat.
Lifesaving › Lifefloat › Lifeline
Issued 3 December 2009 Resolved
Both lifefloat sea lifeline holders are wasted and could affect the proper release of the lifefloats. Renew lifeline brackets as needed. Both lifefloats may be attached to a single lifeline and weak link. See supplied reference material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 4 January 2010
Resolution: Life line bracket repaired satisfactory and both life floats are attached to one life line. All Sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 December 2009 Resolved
The 360 degree white navigational light is not visable from all directions of the vessel, it is placed to low in the center of the pilot house top. Raise the light to adequate height above the pilot house or install additional lights as required to obtain the proper visability.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 4 January 2010
Resolution: Light was raised up approx 4 feet and allows 360 visibility. All Sat.
Stability › Incline Test › General
Issued 3 December 2009 Resolved
Stability letter does not allow for passengers on the upper deck. Place sign stating no passengers allowed on upper deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 4 January 2010
Resolution: Sign installed at ladder. All Sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 December 2009 Resolved
Store child size life jackets separate from adult life jackets and properly label storage compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 4 January 2010
Resolution: Chid size life jackets properly stowed. All sat.
Lifesaving › Lifebuoys › Serviceable
Issued 3 December 2009 Resolved
Ring buoy is faded and needs repainted. Repaint or renew ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 4 January 2010
Resolution: Ring buoy was repainted. All sat.
Engineering › Bilge Water Management System › Valve
Issued 3 December 2009 Resolved
Label bilge mainfold valves and provide schematic and instructions for operation of bilge system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 4 January 2010
Resolution: Bilge valves properly labeled. All Sat.
Engineering › Bilge Water Management System › Valve
Issued 3 December 2009 Resolved
Valve handle missing on engine room submersible electric bilge pump overboard discharge valve. Install new valves handle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 4 January 2010
Resolution: New overboard discharge for submersible electirc bilge pump installed. All sat.
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 December 2009 Resolved
All batteries in engine room are loose and storage boxes are broken and missing tops. Properly secure all batteries and provide adequate storage box for each battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 4 January 2010
Resolution: New battery boxes installed. All Sat.
Communications › Radio Communications › EPIRB
Issued 31 October 2008 Resolved
Have EPIRB seviced, replace antenna and hydrostatic release, vessel is restricted to 3 miles from shore until cleared.
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 5 November 2008
Lifesaving › Lifefloat › Paddle
Issued 31 October 2008 Resolved
Stencil paddles for lifefloats.
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 5 November 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 November 2007 Resolved
Provide battery covers for battery housings in engine room.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 13 December 2007
Lifesaving › Lifefloat › Markings
Issued 13 November 2007 Resolved
Replace retro reflective tape on Lifefloats were needed.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 13 December 2007
Lifesaving › Lifebuoys › Serviceable
Issued 13 November 2007 Resolved
Provide corrosion proof clip for ring lifebouy waterlight lanyard.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 13 December 2007
Documentation › Certificates/Documents › FCC SSL
Issued 13 November 2007 Resolved
Provide FCC Radiotelephony safety certificate.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 13 December 2007
Documentation › Certificates/Documents › FCC SSL
Issued 13 November 2007 Resolved
Provide proof of FCC radio operators permit for master of vessel.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 13 December 2007
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 13 November 2007 Resolved
Provide log for man overboard and fire drills.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 13 December 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 November 2007 Resolved
Provide NOAA Coast Pilot and USCG Light List onboard vessel.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 13 December 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 November 2007 Resolved
Repair leak and prove double clamping for raw water shaft cooling line.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 13 December 2007
Navigation › Piloting/Steering › Marine Charts
Issued 26 September 2006 Resolved
Provide navigational charts of area of operation; prior to 26Oct2006.
Action required: 705 - Other - as specified
Due 26 October 2006
Resolved 29 September 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 September 2006 Resolved
Properly arrange wiring around operator's station, prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2006
Communications › Alarms/Indicators › High Water Alarm
Issued 26 September 2006 Resolved
Label visual indicators for high level bilge alarms at operator's station; prior to 26Oct2006.
Action required: 705 - Other - as specified
Due 26 October 2006
Resolved 29 September 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 September 2006 Resolved
Properly attach lifeline of ring lifebouy to same; prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2006
Lifesaving › Lifefloat › Float-free Link
Issued 26 September 2006 Resolved
Provide weak links for lifefloats; Prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2006
Lifesaving › Lifefloat › Float Free
Issued 26 September 2006 Resolved
Properly arrange lifefloats to be float free; Prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2006
Lifesaving › Lifefloat › Paddle
Issued 26 September 2006 Resolved
Label vessel's name on paddles; Prior to 26Oct2006
Action required: 705 - Other - as specified
Due 26 October 2006
Resolved 29 September 2006
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 September 2006 Resolved
Mount EPIRB, make float free, test monthly; Vessel restricted to 3nm.
Action required: 705 - Other - as specified
Due 26 October 2006
Resolved 29 September 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 September 2006 Resolved
Service engine space fixed fire extinguisher; prior to 30Sep2006.
Action required: 705 - Other - as specified
Due 30 September 2006
Resolved 29 September 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 September 2006 Resolved
Provide machinary guard for starboard main engine, exposed open rotating belts; prior to 26Oct2006.
Action required: 705 - Other - as specified
Due 26 October 2006
Resolved 29 September 2006
Construction/Loadline › Hull › Stiffener
Issued 8 December 2005 Resolved
Crop and renew deck frames portside engine space as indicated by marine inspector.
Due 8 January 2006
Resolved 5 January 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 December 2005 Resolved
Remove angel hair portside longitudinal in engine compartment and treat with preservative.
Due 8 January 2006
Resolved 5 January 2006
Construction/Loadline › Structures › Deck Plating
Issued 8 December 2005 Resolved
Remove angel hair from deck #1 compartment and treat with preservative.
Due 8 January 2006
Resolved 5 January 2006
Construction/Loadline › Structures › Manhole
Issued 8 December 2005 Resolved
Attach lanyards to all hatches.
Due 8 January 2006
Resolved 5 January 2006
Construction/Loadline › Structures
Issued 3 December 2003 Resolved
Crop and renew underdeck longitudinal frame and transverse clamp along engineroom bulkhead in way of starboard fuel tank. LEGACY COMPONENT DESC: Framing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2004
Resolved 15 December 2003
Resolution: Corrected.
Engineering › Fuel Oil Storage/Transfer System
Issued 3 December 2003 Resolved
Renew wasted hose clamps on starboard fuel fill and install bonding wire. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2004
Resolved 2 January 2004
Resolution: Corrected. Owner installed four new stainless hoseclamps on each fill and renewed bonding wires
Construction/Loadline › Penetrations
Issued 3 December 2003 Resolved
Renew cap to previously installed used through-hull fitting, starboard side engine room. LEGACY COMPONENT DESC: Through-hull fitting
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 January 2004
Resolved 4 December 2003
Resolution: Corrected. Owner capped with bronze cap.
Construction/Loadline › Penetrations
Issued 3 December 2003 Resolved
Install cap to previously installed Jabsco pump discharge on port side engineroom. LEGACY COMPONENT DESC: Through-hull fitting
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 January 2004
Resolved 4 December 2003
Resolution: Corrected. Owner capped with bronze cap.
Construction/Loadline › Structures
Issued 3 December 2003 Resolved
Install captive pins on engine room hatches. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 January 2004
Resolved 15 December 2003
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 September 2003 Resolved
Modify deck rails so that the space between rail courses does not exceed 4 inches. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 25 December 2003
Resolved 25 December 2003
Resolution: Corrected. Owner installed additional wire courses between the top course rail and the top of the gunwhale.
Engineering
Issued 5 October 2000 Resolved
Properly support the M/E cooling piping and replace the worn hoses._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 12 October 2000
Resolved 19 October 2000
Construction/Loadline
Issued 5 October 2000 Resolved
Provide a light for each space on the high-level bilge alarm system._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 October 2000
Resolved 19 October 2000
Lifesaving
Issued 5 October 2000 Resolved
Replace the hydrostatic release on the EPIRB._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 October 2000
Resolved 19 October 2000
Lifesaving
Issued 5 October 2000 Resolved
Affix new retro-reflective tape on L/Fs._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 October 2000
Resolved 19 October 2000
Navigation
Issued 2 October 1997 Resolved
Tighten loose rudder post bushing on port rudder post._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 1997
Resolved 31 October 1997
Lifesaving
Issued 2 October 1997 Resolved
Repair 14 adult and 1 child PFD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 1997
Resolved 14 October 1997
Lifesaving
Issued 2 October 1997 Resolved
Provide a ladder to retrieve someone from the water._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 1997
Resolved 31 October 1997
Navigation
Issued 2 October 1997 Resolved
Provide a current copy of tide/current tables, light list, coast pilot and T-regs._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 1997
Resolved 31 October 1997
Navigation
Issued 2 October 1995 Resolved
Have compass calibrated and post the compass card.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Lifesaving
Issued 2 October 1995 Resolved
Replace retro-reflective material as necessary on all lifejackets._x001C_ (Some jackets found to be borderline acceptable)
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Engineering
Issued 27 October 1993 Resolved
Restencil fuel shut off per discussion with inspector.
Condition: Unknown
Due 27 November 1993
Resolved 10 November 1993
Fire Fighting
Issued 27 October 1993 Resolved
Stencil location of B-I fire extinguisher on open bridge._x001C_ OR_x001C_ Relocate it outside the locker it is being stowed in.
Condition: Unknown
Due 27 November 1993
Resolved 10 November 1993
Construction/Loadline
Issued 27 October 1993 Resolved
Crop and renew as necessary area in way of the collision bulkhead on main deck. Area is weak and shows signs of seperation over an area of approximately 8 square feet.
Condition: Unknown
Due 27 November 1993
Resolved 10 November 1993

Casualty record · 1

17 March 2022Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 7413612
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.