MAURY USCG vessel records Sign in
← All vessels

U.S.S. ENTERPRISE

U.S.S. ENTERPRISE is a 1969 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 1985, most recently in February 1998, along with 19 deficiencies.

Records from 1985 to 1998. Most recent: inspection, 7 February 1998.

Built
1969
Last inspected
7 February 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WY7275
Flag
UNITED STATES
—
Maury page id
psix-46126

Inspections, by type

…with no type recorded3
Years with a record 6 calendar years (1985–1998)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
14 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 12

7 February 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 96150
14 March 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1219139
5 March 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1240642
25 February 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 929967
5 April 1989 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1347569
11 January 1989 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1193878
25 March 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1017750
12 February 1987 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1319951
3 July 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1298799
5 February 1986 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 986892
10 September 1985 Deficiency Check · Credit Drydock
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1297299
7 May 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1292053

Deficiency record · 19

Construction/Loadline
Issued 25 February 1991 Resolved
PROVIDE SECURING DEVICE FOR FWD HATCH PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Deck/Cargo
Issued 25 February 1991 Resolved
REPLACE THE THROUGH BOLTS ON THE FOLLOWING MOORING CLEATS:_x001C_ A) FWD AND MIDSHIPS STBD_x001C_ B) MIDSHIPS AND AFT PORT
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Deck/Cargo
Issued 25 February 1991 Resolved
PROVIDE ADEQUATE GROUND TACKLE. (MSOSFBINST 16711.6)
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Construction/Loadline
Issued 25 February 1991 Resolved
ROUT OUT TO GOOD WOOD AND PROPERLY REPAIR DAMAGED AREA OF THE STEM JUST ABOVE THE WIND/WATERLINE.
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Construction/Loadline
Issued 25 February 1991 Resolved
REPAIR 3 DELAMINATED AREAS ON THE STBD SIDE KEEL.
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Navigation
Issued 25 February 1991 Resolved
REPLACE OR SHIM PORT RUDDER POST BUSHING TO REDUCE EXCESS PLAY.
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Engineering
Issued 5 April 1989 Resolved
DOUBLE NUT OR DRILL AND PIN TRANSMISSION AND THROTTLE CONTROL LINKAGES ON BOTH ENGINES.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Lifesaving
Issued 5 April 1989 Resolved
REPLACE SIX ORANGE SMOKE FLARES BEFORE JUN'89 EXPIRATION DATE.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Engineering
Issued 5 April 1989 Resolved
REPAIR FUEL INJECTOR PUMP LEAK ON STBD ENGINE.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Engineering
Issued 5 April 1989 Resolved
FUEL SHUT-OFF VALVES FOR BOTH FUEL TANKS MUST BE ACCESSIBLE FROM OUTSIDE FUEL COMPARTMENT.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Navigation
Issued 5 April 1989 Resolved
PROVIDE CURRENT COPY OF NAVIGATION RULES.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Fire Fighting
Issued 5 April 1989 Resolved
SERVICE OR REPLACE B-I FIRE EXTINGUISHER.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Lifesaving
Issued 5 April 1989 Resolved
REPLACE WEAK LINK ON BUOYANT APPARTATUS PAINTER.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Navigation
Issued 5 April 1989 Resolved
PROVE OPERATION OF RADAR.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Lifesaving
Issued 5 April 1989 Resolved
PROVIDE ONE ADULT PFD. TOTAL PERSONS ON BOARD REDUCED TO 23 UNTIL ADDITIONAL PFD IS PROVIDED.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Lifesaving
Issued 12 February 1987 Resolved
1. PROVIDE 6 HAND ORANGE SMOKE DISTRESS SIGNALS WITH CURRENT DATES.
Condition: Unknown
Due 12 February 1987
Resolved 12 February 1987
Unknown
Issued 12 February 1987 Resolved
2. REPAIR ENGINE ROOM AIR VENT WHERE LOWER SECTION OF PIPING IS WAISTED.
Condition: Unknown
Due 12 February 1987
Resolved 12 February 1987
Construction/Loadline
Issued 10 September 1985 Resolved
SCRAPE AND APPLY PROTECTIVE COATING TO FURRING MEMBERS AND PLYWOOD IN ENGINEROOM AND LAZERETTE.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Construction/Loadline
Issued 10 September 1985 Resolved
INSTALL DOUBLER BOARD AND REFIBERGLASS PORT SIDE (DAMAGED AREA) OF TRANSOM. DOUBLER TO EXTEND AT LEAST THREE (3) FEET FROM CORNER POST
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985