Records from 1985 to 1998. Most recent: inspection, 7 February 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
7 February 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 96150
14 March 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1219139
5 March 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1240642
25 February 1991
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 929967
5 April 1989
COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1347569
11 January 1989
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1193878
25 March 1987
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1017750
12 February 1987
Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1319951
3 July 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1298799
5 February 1986
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 986892
10 September 1985
Deficiency Check · Credit Drydock
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1297299
7 May 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1292053
Construction/Loadline
Issued 25 February 1991
Resolved
PROVIDE SECURING DEVICE FOR FWD HATCH PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Deck/Cargo
Issued 25 February 1991
Resolved
REPLACE THE THROUGH BOLTS ON THE FOLLOWING MOORING CLEATS:_x001C_ A) FWD AND MIDSHIPS STBD_x001C_ B) MIDSHIPS AND AFT PORT
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Deck/Cargo
Issued 25 February 1991
Resolved
PROVIDE ADEQUATE GROUND TACKLE. (MSOSFBINST 16711.6)
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Construction/Loadline
Issued 25 February 1991
Resolved
ROUT OUT TO GOOD WOOD AND PROPERLY REPAIR DAMAGED AREA OF THE STEM JUST ABOVE THE WIND/WATERLINE.
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Construction/Loadline
Issued 25 February 1991
Resolved
REPAIR 3 DELAMINATED AREAS ON THE STBD SIDE KEEL.
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Navigation
Issued 25 February 1991
Resolved
REPLACE OR SHIM PORT RUDDER POST BUSHING TO REDUCE EXCESS PLAY.
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Engineering
Issued 5 April 1989
Resolved
DOUBLE NUT OR DRILL AND PIN TRANSMISSION AND THROTTLE CONTROL LINKAGES ON BOTH ENGINES.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Lifesaving
Issued 5 April 1989
Resolved
REPLACE SIX ORANGE SMOKE FLARES BEFORE JUN'89 EXPIRATION DATE.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Engineering
Issued 5 April 1989
Resolved
REPAIR FUEL INJECTOR PUMP LEAK ON STBD ENGINE.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Engineering
Issued 5 April 1989
Resolved
FUEL SHUT-OFF VALVES FOR BOTH FUEL TANKS MUST BE ACCESSIBLE FROM OUTSIDE FUEL COMPARTMENT.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Navigation
Issued 5 April 1989
Resolved
PROVIDE CURRENT COPY OF NAVIGATION RULES.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Fire Fighting
Issued 5 April 1989
Resolved
SERVICE OR REPLACE B-I FIRE EXTINGUISHER.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Lifesaving
Issued 5 April 1989
Resolved
REPLACE WEAK LINK ON BUOYANT APPARTATUS PAINTER.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Navigation
Issued 5 April 1989
Resolved
PROVE OPERATION OF RADAR.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Lifesaving
Issued 5 April 1989
Resolved
PROVIDE ONE ADULT PFD. TOTAL PERSONS ON BOARD REDUCED TO 23 UNTIL ADDITIONAL PFD IS PROVIDED.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Lifesaving
Issued 12 February 1987
Resolved
1. PROVIDE 6 HAND ORANGE SMOKE DISTRESS SIGNALS WITH CURRENT DATES.
Condition: Unknown
Due 12 February 1987
Resolved 12 February 1987
Unknown
Issued 12 February 1987
Resolved
2. REPAIR ENGINE ROOM AIR VENT WHERE LOWER SECTION OF PIPING IS WAISTED.
Condition: Unknown
Due 12 February 1987
Resolved 12 February 1987
Construction/Loadline
Issued 10 September 1985
Resolved
SCRAPE AND APPLY PROTECTIVE COATING TO FURRING MEMBERS AND PLYWOOD IN ENGINEROOM AND LAZERETTE.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Construction/Loadline
Issued 10 September 1985
Resolved
INSTALL DOUBLER BOARD AND REFIBERGLASS PORT SIDE (DAMAGED AREA) OF TRANSOM. DOUBLER TO EXTEND AT LEAST THREE (3) FEET FROM CORNER POST
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985