MAURY USCG vessel records Sign in
← All vessels

VIKING STARLITE

VIKING STARLITE is a 1969 passenger vessel (inspected). The Coast Guard has recorded 70 inspections since 1985, most recently in March 2026, along with 112 deficiencies — 1 with no resolution recorded —.

Records from 1985 to 2026. Most recent: inspection, 11 March 2026.

Built
1969
Last inspected
11 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC5017
Flag
UNITED STATES
366813140
Maury page id
psix-46127

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 37 calendar years (1985–2026)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)59.5 ft × 18.8 ft × 5.6 ft
Registered tonnagegross 55 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTEVENSON BOAT WORKS · GREAT KILLS, STATEN ISLAND NY, UNITED STATES · built 1969
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONTAUK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 24 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Regulatory (Subpart C or D), Gross Ton
37 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL5017MMSI 366813140 · active · compulsorily equipped · granted 12 March 2020, expires 12 March 2030
WDA4790MMSI 366813140 · cancelled · compulsorily equipped · granted 17 March 2011, cancelled 5 March 2020 · licensed under a name not among this hull’s recorded names (not shown)
WSN8004MMSI not assigned · expired · compulsorily equipped · granted 21 March 1997, cancelled 19 March 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 70

11 March 2026 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8325245
30 January 2026 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8304011
12 June 2025 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8157322
21 May 2025 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8140407
4 April 2024 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7891842
5 December 2023 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7826367
28 June 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7725400
28 April 2022 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7439714
4 November 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7340606
11 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7193668
14 July 2020 In-Service Inspection · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6993698
1 November 2019 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6843465
1 May 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6656589
22 October 2018 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6563860
23 July 2018 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6488162
8 May 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6394397
1 November 2017 Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6296014
3 May 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6137785
27 April 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5862183
4 November 2015 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5756950
27 April 2009 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3461906
22 April 2008 Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3189939
24 October 2007 Hull Examination · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3085976
25 April 2007 Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2915243
24 April 2006 Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2631985
1 November 2005 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2526068
19 April 2005 COI Inspection · Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2338039
23 April 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2044738
28 October 2003 Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1935397
12 May 2003 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1789389
22 April 2002 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1606611
6 December 2001 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1366651
31 October 2001 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 772502
3 May 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1436555
28 June 2000 Excursion Permit
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 820239
7 June 2000 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1403161
21 April 2000 COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1365722
12 April 2000 Hull Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1454800
11 May 1999 Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1369247
10 May 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1132164
30 April 1999 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1116505
20 October 1998 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 801098
11 May 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1124923
21 April 1998 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1419914
23 April 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1099278
14 January 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1104569
22 April 1996 MARPOL Annex V Examination · Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1083950
4 November 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1184366
11 May 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1191294
20 April 1994 MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 868979
6 May 1993 Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 845897
28 April 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 956477
10 October 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 949954
12 April 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941310
29 March 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 901578
24 September 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 921802
20 April 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1220039
3 April 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 910956
2 March 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 905126
16 October 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1323661
11 April 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340687
24 October 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202834
21 March 1988 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1043459
21 March 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351235
23 October 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1330976
8 April 1987 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020993
13 May 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991941
10 April 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 999430
22 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 979609
8 March 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289338

Deficiency record · 112

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 January 2026 No resolution recorded
The subject vessel in not authorized to carry passengers for hire until a dry dock inspection and internal structural exam is conducted by a USCG Marine Inspector. The anniversary date was 31DEC2025 and failed to meet her 2025 inspection requirements.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2026 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 June 2025 Resolved
Vessels EPIRB battery due to expire at the end of the month.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2025
Resolved 17 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 12 June 2025 Resolved
Stabd side railing has a wire rope course that was loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 17 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2025 Resolved
Remove dead end wires in fwd bulkhead in E/R.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 17 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2022 Resolved
Label L/J lockers
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 29 April 2022
Resolution: O/O provided photographic evedence of placards being updated and installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 April 2022 Resolved
Install a means of securing/closing the ventilation to the ventilation to the engine room in the event of a fire and need to set off fixed system.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 29 April 2022
Resolution: O/O provided photographic proof the vent closures had been installed.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 28 April 2022 Resolved
Provide a rescue ladder for Man overboard recovery.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2022
Resolved 5 May 2022
Resolution: Ladder was purchased and place onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 May 2021 Resolved
Relabel Life Floats
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 11 May 2021
Resolution: Corrected on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 July 2020 Resolved
Vessel COI indicated Life float compliment onboard to meet 53 total POB. Vessel is only outfitted with 2 22 person life floats for a total of 44. Vessel is not to operate on LCW routes > or = to 3 miles from shore with more than 44 total persons in cold water. On all other routes permitted the vessel meets 50% required and is allowed 88 total persons.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 July 2020
Resolved 14 July 2020
Resolution: Amended COI onboard and reflected changes in system, routed new COI.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 8 May 2018 Resolved
Properly install distribution panel for DC load from battery bank #1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 23 July 2018
Resolution: O/O updated elecrical installation
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 May 2018 Resolved
Properly install wire splice
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 23 July 2018
Resolution: O/O updated spliace an installed junction box
Construction/Loadline › Hull › Transverse Frame
Issued 4 November 2015 Resolved
Repair 2 cracked frames in lazarette on Stern just stbd of keel.
Action required: 705 - Other - as specified
Due 4 November 2015
Resolved 4 November 2015
Resolution: repaired later that day with 2 sister frames.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 4 November 2015 Resolved
Repair fuel hose interconnect between the 2 fuel tanks with approved hose. Current hose is bubbling.
Action required: 705 - Other - as specified
Due 1 December 2015
Resolved 17 November 2015
Documentation › Markings/Placards › Capacity Marking
Issued 4 November 2015 Resolved
Mark proper upper deck capacity (12)
Action required: 705 - Other - as specified
Due 1 December 2015
Resolved 17 November 2015
Engineering › Fuel Oil Service System › Hose
Issued 22 April 2008 Resolved
Replace three fuel hoses and fittings between Racor filters and all three engines. Prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2008
Resolved 24 April 2008
Resolution: Returned to vessel the following day and verified proper installation of new fuel hoses.
Construction/Loadline › Hull › Transverse Frame
Issued 24 October 2007 Resolved
Refasten floor timbers to keel in aft compt.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2008
Resolved 25 March 2008
Resolution: Completed satisfactorily. Two additional lag bolts installed in each floor timber.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 24 October 2007 Resolved
Refasten shaftlogs to hull planking in aft compt.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2007
Resolved 5 November 2007
Resolution: Rebolted to shell planking.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 October 2007 Resolved
Fit batten IWO bilge suction pipe penetration of aft WT BHD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2007
Resolved 2 November 2007
Resolution: Completed.
Electrical › Electrical Distribution System (service) › Cable
Issued 24 October 2007 Resolved
Complete replacement in kind of electrical wiring in below deck spaces. Insufficient number of wiring retainers in use. Minimum at least one for each 2'.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 25 March 2008
Resolution: Completed satisfactorily.
Construction/Loadline › Hull › Hull Plating
Issued 24 October 2007 Resolved
Replace missing nuts on bolt fasteners for butt block stbd side of bottom approximately even w/ the front of the SMDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2007
Resolved 2 November 2007
Resolution: Completed.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 24 October 2007 Resolved
Repair operations normal "power light" (green LED) on fire alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2007
Resolved 2 November 2007
Resolution: Completed.
Engineering › Bilge Water Management System › Piping
Issued 24 October 2007 Resolved
Reconnect O/B discharge piping to the thru hull.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2008
Resolved 25 March 2008
Resolution: Completed satisfactorily. New pipe & hose fitted.
Communications › Radio Communications › EPIRB
Issued 24 October 2007 Resolved
Renew battery for EPIRB and insure registration is up to date. Vessel must operate less than three miles from shore during cold water periods until this requirement is completed to the satisfaction of a CG Marine Inspector. 3.25.08: New EPIRB on backorder. Expect arrival in April 08.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 3 April 2008
Resolution: New EPIRB aboard and registered w/ NOAA
Construction/Loadline › Hull › Sheerstrake
Issued 24 October 2007 Resolved
Replace approximately 20' of rubrail on stbd side from midship fwd. Owner initiated repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 November 2007
Resolved 2 November 2007
Resolution: Completed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 April 2006 Resolved
Provide/install guard for starboard alternator.
Condition: Placed in Improper Service
Due 24 May 2006
Resolved 23 May 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 April 2006 Resolved
Install guards for engine room lighting
Condition: Improper Installation
Due 24 May 2006
Resolved 23 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 24 April 2006 Resolved
Provide an additional L/J, vessel PAX count reduced to 89
Condition: Unknown
Due 2 May 2006
Resolved 23 May 2006
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 24 April 2006 Resolved
Provide a coast pilot and tide table
Condition: Unknown
Due 2 May 2006
Resolved 23 May 2006
Lifesaving › Lifefloat › Markings
Issued 19 April 2005 Resolved
Re-stencil lifefloat markings.
Due 4 May 2005
Resolved 4 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifefloat › Float-free Link
Issued 19 April 2005 Resolved
Replace float-free link for primary lifesaving with one of appropriate capacity.
Due 4 May 2005
Resolved 5 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 19 April 2005 Resolved
Repair cover of one adult lifejacket, vessel restricted to 89 adults until corrected.
Due 4 May 2005
Resolved 4 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Documentation › Markings/Placards › Lifejacket Placard
Issued 19 April 2005 Resolved
Post signs for lifejacket stowage.
Due 4 May 2005
Resolved 5 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 19 April 2005 Resolved
Tighten both tailshaft packings.
Due 4 May 2005
Resolved 4 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 19 April 2005 Resolved
Properly secure exhaust pipes in tankroom.
Due 4 May 2005
Resolved 4 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Operations/Management › Drills/Instruction
Issued 23 April 2004 Resolved
Conduct man overboard, abandoned ship, and fire fighting drills with entire crew prior to carrying passengers. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 2 May 2004
Resolved 29 April 2004
Operations/Management › Drills/Instruction
Issued 23 April 2004 Resolved
Post fixed fire fighting instructions. LEGACY COMPONENT DESC: Fire
Due 2 May 2004
Resolved 29 April 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 April 2004 Resolved
Provide required items for first aid kit (ammonia inhalents, eyewash). LEGACY COMPONENT DESC: Medicine Chest
Due 2 May 2004
Resolved 29 April 2004
Lifesaving › Buoyant Apparatus
Issued 23 April 2004 Resolved
Provide paddles (labeled) for 12 man life float. LEGACY COMPONENT DESC: Paddles
Due 2 May 2004
Resolved 29 April 2004
Lifesaving › Buoyant Apparatus
Issued 23 April 2004 Resolved
Connect painter and weak link to 12 man life float.
Due 2 May 2004
Resolved 29 April 2004
Lifesaving › Buoyant Apparatus
Issued 23 April 2004 Resolved
Provide waterlight for life float.
Due 2 May 2004
Resolved 29 April 2004
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 23 April 2004 Resolved
Mount Fire Extinguishers in cabin for access to passengers. LEGACY COMPONENT DESC: Location
Due 2 May 2004
Resolved 29 April 2004
Engineering › Generator (propulsion-electric)
Issued 23 April 2004 Resolved
Provide specs for newly (rebuilt) installed generator.
Due 2 May 2004
Resolved 29 April 2004
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 22 April 2002 Resolved
Unable to secure hatches, Repair/Renew. Ensure hatches are sealed prior to getting underway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2002
Resolved 10 May 2002
Resolution: Received ltr from Captain of vsl item complete.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 22 April 2002 Resolved
Ground wire missing from fuel tank fill. Install ground conductor
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2002
Resolved 10 May 2002
Resolution: Received ltr from Captain of VSL, item complete.
Navigation › Piloting/Steering › Magnetic Compass
Issued 22 April 2002 Resolved
Compass light inop. Repair/Renew
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2002
Resolved 10 May 2002
Resolution: Received ltr item corrected.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 April 2002 Resolved
No fwd mast light. Install mast light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 May 2002
Resolved 10 May 2002
Resolution: Received fax, item corrected
Lifesaving › Buoyant Apparatus › Self-igniting Lights
Issued 22 April 2002 Resolved
Water lights not attached to BA properly. Intall 18' pendents
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 May 2002
Resolved 10 May 2002
Resolution: Received fax item corrected.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 22 April 2002 Resolved
BII ext discharged, Repair/Renew
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2002
Resolved 10 May 2002
Resolution: Received ltr item corrected.
Lifesaving
Issued 3 May 2001 Resolved
PROVIDE SUPERVISOR TRAINING RECORDS AS PER 46CFR16. (DRUG SCREENING PROGRAM).
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Lifesaving
Issued 3 May 2001 Resolved
PROVIDE A COPY OF THE DRUG CONSORTIUM CONTRACT. (INSTRUCTIONS FOR CONDUCTING THE PROGRAM).
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Lifesaving
Issued 3 May 2001 Resolved
REPLACE BATTERIES IN WATERLIGHTS. DO NOT USE ALKALINE BATTERIES AS THEY ARETOO HEAVY.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Unknown
Issued 3 May 2001 Resolved
PROVIDE A BULLHORN OR PA SYSTEM FOR USE AS COMMS ABOARD THE VESSEL.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Lifesaving
Issued 3 May 2001 Resolved
PROVIDE THE CREW LIST AS PROVIDED TO THE CONSORTIUM.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Electrical
Issued 3 May 2001 Resolved
RELABEL ALL BREAKERS & SWITHCHES.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Lifesaving
Issued 3 May 2001 Resolved
PROVIDE EMERGENCY INSTRUCTIONS SPECIFIC TO THE VESSEL. (SEE 46CFR185.510 & .512).
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Construction/Loadline
Issued 3 May 2001 Resolved
PROVIDE DOG WRENCH & PROVE OPERATION OF DECK HATCH DOGS. VESSEL RESTRICTED TO RIVERS ROUTES UNTIL COMPLETED.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Navigation
Issued 3 May 2001 Resolved
PROVIDE COAST PILOT & LIGHT LIST FOR THE VESSEL'S OPERATING AREA.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Unknown
Issued 3 May 2001 Resolved
PROVIDE A COPY OF THE RULES FOR THE CLASS OF VESSEL. (46 CFR SUB T).
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Lifesaving
Issued 3 May 2001 Resolved
PROVIDE CREW TRAINING RECORDS AFTER THREE MONTHS OF OPERATION. (SEE 46CFR185.420).
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Lifesaving
Issued 21 April 2000 Resolved
PROVIDE RETRO-REFLECTIVE TAPE ON 1 RING BOUY.
Condition: Unknown
Due 28 April 2000
Resolved 25 April 2000
Navigation
Issued 21 April 2000 Resolved
PROVIDE AN ADDITIONAL NUT OR A COTTER PIN TO BOLT IN ROCKER ARM.
Condition: Unknown
Due 28 April 2000
Resolved 25 April 2000
Fire Fighting
Issued 21 April 2000 Resolved
PROVIDE HYDRO TESTS FOR 2 B-11 PORTABLE EXTINGUISHERS.
Condition: Unknown
Due 28 April 2000
Resolved 25 April 2000
Unknown
Issued 11 May 1999 Resolved
PROVIDE COPY OF THE CREW LIST.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Lifesaving
Issued 11 May 1999 Resolved
RENEW HYDROSTATIC RELEASE FOR EPIRB AND MOUNT EPIRB. INLAND OPS ONLY UNTILCLEARED.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Fire Fighting
Issued 11 May 1999 Resolved
INSURE MONTHLY FIRE EXTINGUISHER INSPECTION RECORDS ARE KEPT BY "PERSON IN CHARGE".
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Lifesaving
Issued 11 May 1999 Resolved
POST PFD INSTRUCTIONS.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Engineering
Issued 11 May 1999 Resolved
REMARK "EMERGENCY FUEL SHUTOFF".
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Navigation
Issued 11 May 1999 Resolved
RESECURE TO PORT NAV SIDELIGHT SCREEN.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Lifesaving
Issued 11 May 1999 Resolved
INSTALL A 3' TO 6' LANYARD W/A QUICK RELEASE CLIP TO ATTACH WATERLIGHT TO THE RING BUOY.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Unknown
Issued 11 May 1999 Resolved
POST DRUG HOTLINE PHONE NUMBER.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Fire Fighting
Issued 11 May 1999 Resolved
REINSTALL TAMPER SEALS ON 2 B-II EXTINGUISHERS.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Lifesaving
Issued 11 May 1999 Resolved
POST FCC BROADCAST INSTRUCTIONS NEAR FM RADIO.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Construction/Loadline
Issued 11 May 1999 Resolved
REPAIR LOOSE HOSE AT BILGE MANIFOLD #1 COMPT., AND REPLACE MISSING CLAMPS ON BILGE LINES IN #2 AND #3 COMPTS.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Fire Fighting
Issued 10 May 1999 Resolved
CONDUCT INSTALLATION INSPECTION AND TEST OF FIXED CO2/FIRE DETECTION SYSTEM/PIPING.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Electrical
Issued 11 May 1998 Resolved
REMOVE DEADENDED WIRING THROUGHOUT VESSEL. (SPECIFICALLY IN BOTH CLOSETS, MAIN DECK, PASSENGER CABIN).
Condition: Unknown
Due 18 May 1998
Resolved 14 May 1998
Lifesaving
Issued 11 May 1998 Resolved
LABEL DISTRESS SIGNAL BOX.
Condition: Unknown
Due 18 May 1998
Resolved 14 May 1998
Lifesaving
Issued 11 May 1998 Resolved
PROVIDE 1 ADULT PFD. PASSENGER CARRYING CAPACITY REDUCED TO 79 ADULTS AND 8 CHILDREN UNTIL CLEARED.
Condition: Unknown
Due 18 May 1998
Resolved 14 May 1998
Electrical
Issued 11 May 1998 Resolved
LABEL ALL CIRCUIT BREAKERS ON VESSEL. (SPECIFICALLY, MAIN DECK PASSENGER CABIN CLOSETS).
Condition: Unknown
Due 18 May 1998
Resolved 14 May 1998
Lifesaving
Issued 11 May 1998 Resolved
PROVE PROPER OPERATION OF THE ONE INOP WATERLIGHT.
Condition: Unknown
Due 18 May 1998
Resolved 14 May 1998
Lifesaving
Issued 11 May 1998 Resolved
STENCIL ALL PFDs MISSING STENCILS. (36 ADULT AND 4 CHILD).
Condition: Unknown
Due 18 May 1998
Resolved 14 May 1998
Lifesaving
Issued 21 April 1998 Resolved
RECONFIGURE UPPER DECK RAILS IAW 46CFR177.900 FOR EXCURSION VESSELS.
Condition: Unknown
Due 21 April 1998
Resolved 21 April 1998
Construction/Loadline
Issued 21 April 1998 Resolved
SISTER MAIN DECK SUPPORT BEAMS IN CRASH COMPT. ON EITHER SIDE OF HATCH.
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Construction/Loadline
Issued 21 April 1998 Resolved
RENEW ALL BUTT BLOCK BOLTS THROUGHOUT VESSEL WHICH ARE BELOW WATER LINE.
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Construction/Loadline
Issued 21 April 1998 Resolved
SCRAPE OUT ALL ANGEL HAIR IN E/R.
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Electrical
Issued 23 April 1997 Resolved
LABEL ALL CIRCUIT BREAKERS THROUGHOUT BOAT AND MAKE DIAGRAMS IN BREAKER BOXES MATCH BREAKER CONFIGURATION.
Condition: Unknown
Due 23 May 1997
Resolved 19 June 1997
Electrical
Issued 23 April 1997 Resolved
REMOVE DEAD ENDED WIRING IN E/R.
Condition: Unknown
Due 23 May 1997
Resolved 19 June 1997
Navigation
Issued 23 April 1997 Resolved
PROVE PROPER OPERATION OF RADAR. VESSEL OPERATIONS RESTRICTED TO L, B, ANDS UNTIL FIXED.
Condition: Unknown
Due 23 May 1997
Resolved 19 June 1997
Accommodation/Occupational Safety
Issued 29 March 1991 Resolved
PROVE PROPER OPERATION OF WASH BASINS LOCATED IN THE MALE AND FEMALE HEADS.46 CFR 177.30-5(A). MUST BE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Lifesaving
Issued 29 March 1991 Resolved
PROVIDE AND POST DONNING INSTRUCTIONS FOR LIFEJACKET. POST CHECK OFF LIST OF EMERGENCY PROCEDURES MUST BE TO THE SATISFACTION OF THE ATTENDING MARINEINSPECTOR,
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Documentation
Issued 29 March 1991 Resolved
PROPERLY DISPLAY HOMEPORT ON STERN, MUST BE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Engineering
Issued 16 October 1989 Resolved
PROPERLY LAGG ENGINE EXHAUST PIPES.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Engineering
Issued 16 October 1989 Resolved
RENEW WASTED FUEL PIPING AT BOTTOM OF FUEL TANKS AND SHUT OFF VALVES AT FUEL TANKS.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Electrical
Issued 16 October 1989 Resolved
ADJUST OR RENEW AS NECESSARY DRIVE BELTS FOR WATER PUMP AND ALTERNATORS ON 110 VOLT AC GENERATOR.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Electrical
Issued 16 October 1989 Resolved
REPLACE ALL "NM" (SOLID COPPER ROMES) WIRE USED ON VESSEL WITH STANDARD COPPER WIRE WHICH MEETS THE REQUIREMENTS OF THE ELECTRICAL REGULATIONS IN SUBCHAPTER 46 CFR.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Construction/Loadline
Issued 16 October 1989 Resolved
REPAIR DELAMINATED SECTION OF COLLISION BULKHEAD STARBOARD SIDE FORWARD FACE OF BULKHEAD.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Construction/Loadline
Issued 16 October 1989 Resolved
RENEW WASTED FRAME BOLTS AT CHINE BELOW FOREPEAK ACCESS HATCH.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Engineering
Issued 24 October 1988 Resolved
INSTALL GUARDS OVER DRIVE BELTS ON EXPOSED MACHINERY IN ENGINE ROOM.
Condition: Unknown
Due 24 October 1988
Resolved 24 October 1988
Construction/Loadline
Issued 24 October 1988 Resolved
REPAIR BROKEN BOLT OF FORWARD VERTICAL BRACE IN #2 COMPARTMENT STARBOARD SIDE.
Condition: Unknown
Due 24 October 1988
Resolved 24 October 1988
Engineering
Issued 24 October 1988 Resolved
PROVE PROPER OPERATION OF BILGE VALVE AND REACH ROD IN FORWARD PEAK COMPARTMENT.
Condition: Unknown
Due 24 October 1988
Resolved 24 October 1988
Deck/Cargo
Issued 21 March 1988 Resolved
PROVE OPERATION OF BOW CAPSTAN.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988
Electrical
Issued 21 March 1988 Resolved
PROVIDE PROPER SECURING FOR WIRING IN ENGINE ROOM.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988
Fire Fighting
Issued 21 March 1988 Resolved
SERVICE B-II FIRE EXTINGUISHER, HYDRO OUT OF DATE.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988
Engineering
Issued 21 March 1988 Resolved
REPLACE FLEXIBLE FUEL LINES WITH WIRE MESH REINFORCED HOSE WITHIN A HOSE WHICH HAS A FLAME SHIELDED OUTER JACKET.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988
Engineering
Issued 21 March 1988 Resolved
MAKE PERMANENT REPAIR IN WAY OF TEMPORARY TO PORT ENGINE EXHAUST PIPE AT NEXT DRYDOCKING.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988
Lifesaving
Issued 21 March 1988 Resolved
PROVIDE ONE ADDITIONAL ADULT PFD.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988
Lifesaving
Issued 21 March 1988 Resolved
SECURE WEAK LINK TO VESSEL WITH SHACKLE.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988
Lifesaving
Issued 21 March 1988 Resolved
MARK LIFE FLOATS WITH NUMBER OF PERSONS.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988
Engineering
Issued 21 March 1988 Resolved
PROVIDE CHECK VALVES ON BILGE PUMP OVERBOARDS.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988
Electrical
Issued 21 March 1988 Resolved
REMOVE KNIFE SWITCH AND REPLACE WITH ACCEPTED MARINE SWITCH.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988
Electrical
Issued 21 March 1988 Resolved
RE-SECURE RECEPTACLE ON BRIDGE.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988
Accommodation/Occupational Safety
Issued 21 March 1988 Resolved
INSTALL STOP VALVES ON THROUGH HULL FITTINGS FOR MSD TANK OVERFLOWS.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988
Construction/Loadline
Issued 21 March 1988 Resolved
REPLACE PLASTIC THROUGH HULL FITTINGS WITH METAL FITTINGS.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.