FAST SAILOR is a 1997 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 1997, most recently in May 2016, along with 30 deficiencies and 2 casualty investigations between 2003 and 2006.

Records from 1997 to 2016. Most recent: inspection, 13 May 2016.

Built
1997
Last inspected
13 May 2016
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8968674 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCX7184
461714
Flag
UNITED STATES
367072110 (licence lapsed)
Maury page id
psix-461714

Inspections, by type

…with no type recorded2
Years with a record 14 calendar years (1997–2016)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)150.3 ft × 32.0 ft × 13.0 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)150.3 ft × 32.0 ft × 13.0 ft
ITC tonnagegross 377 / net 113
BuilderBREAUX BROS ENTERPRISES · LOREAUVILLE, LA, UNITED STATES · built 1997
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it407 - Dead Weight, Ton
601 - Displacement, Ton
377 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
113 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCX7184MMSI 367072110 · expired · compulsorily equipped · granted 15 June 2007, cancelled 4 November 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LADY MARIE Passenger (Inspected) · MISLE 37922 · 6 March 2003 · activity 1810421

Inspection history · 33

13 May 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5876104
14 October 2015 Deficiency Check
Physical examination · Activities Europe · Activity 5742356
31 July 2015 MTSA/ISPS Verification · MARPOL Annex V Examination · MARPOL Annex I Examination · Administrative Inspection · COI Inspection
Physical examination · Activities Europe · Activity 5189959
28 December 2010 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3917101
14 December 2010 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3910400
24 September 2010 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3855766
14 October 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3344180
16 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3208085
25 February 2008 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3152978
13 September 2007 Internal Structural Exam · Hull Examination · Examination of Repairs · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3057005
12 February 2007 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2871120
27 October 2006 In-Service Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2809211
19 September 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2781746
9 November 2005 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2531469
20 October 2005 Damage Survey
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2522375
29 September 2005 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2504203
27 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502066
20 September 2005 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2502882
8 December 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2256132
24 June 2004 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2109022
8 June 2004 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2092602
22 October 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1932397
1 October 2003 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1918384
24 April 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1779955
18 March 2003 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1759195
6 March 2003 Damage Survey
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1753667
6 March 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1810421
19 February 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1746406
4 October 2001 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379585
4 October 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466722
13 October 1999 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404845
13 October 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381354
15 October 1997 Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381038

Deficiency record · 30

Deck/Cargo › Mooring/Anchoring › Winch
Issued 31 July 2015 Resolved
Leaking hydraulic hose fitting on controls for anchor windlass.
Action required: 705 - Other - as specified
Due 1 October 2015
Resolved 28 September 2015
Resolution: Unit has been replaced and is operating properly according to ECO Operations officer. Vessel is cold stacked in United States.
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 28 December 2010 Resolved
Conformance test report failed
Action required: 705 - Other - as specified
Resolved 14 January 2011
Resolution: Vessel rep emailed copy of the Conformance test report
Lifesaving › Hand Flares › Expired
Issued 14 October 2008 Resolved
Replace expired distress flares prior to sailing offshore.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2008
Fire Fighting › Grease Extraction Hood › General
Issued 13 September 2007 Resolved
The bulb guard and grease filter was missing from the range hood.
Due 13 October 2007
Resolved 27 September 2007
Engineering › Steering Gear System › Pin
Issued 13 September 2007 Resolved
A cotter pin was missing from the jockey bar/ram attachment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Engineering › Freshwater System (cylinder head cooling) › Storage Tank
Issued 13 September 2007 Resolved
Copper piping for the head tank on the starboard engine was damaged and leaking.
Due 13 October 2007
Resolved 27 September 2007
Construction/Loadline › Markings › Load Line Mark
Issued 29 September 2005 Resolved
Vessel missing Deck Reference Mark, Port and Starboard, also ILL Cert does not agree with image of mark presented on side of ship.
Condition: Unknown
Due 29 October 2005
Resolved 9 November 2005
Resolution: Owner faxed completed worklist to MSU Houma.
Documentation › Markings/Placards › Official Number (US)
Issued 29 September 2005 Resolved
Official Number obscured by breaker boxes.
Condition: Improper Installation
Due 30 October 2005
Resolved 9 November 2005
Resolution: Owner faxed completed worklist to MSU Houma.
Documentation › Markings/Placards › Official Number (US)
Issued 29 September 2005 Resolved
IMO Number not permanently marked on blkhd.
Condition: Improper Installation
Due 30 October 2005
Resolved 9 November 2005
Resolution: Owner faxed completed worklist to MSU Houma.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 29 September 2005 Resolved
Install Exhaust Lagging on Port Engine
Condition: Improper Installation
Due 30 October 2005
Resolved 9 November 2005
Resolution: Owner faxed completed worklist to MSU Houma.
Stability › Watertight Integrity › General
Issued 29 September 2005 Resolved
Make Watertight Bulkhead penetrations in starboard side of engineroom watertight.
Condition: Unknown
Due 30 October 2005
Resolved 9 November 2005
Resolution: Owner faxed completed worklist to MSU Houma.
Engineering › Fuel Oil Service System › Hose
Issued 29 September 2005 Resolved
Install double hose clamps where required on propulsion engines.
Condition: Improper Installation
Due 30 October 2005
Resolved 9 November 2005
Resolution: Owner faxed completed worklist to MSU Houma.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 September 2005 Resolved
Secure Compressed Argon cylinder.
Condition: Unknown
Due 30 October 2005
Resolved 9 November 2005
Resolution: Owner faxed completed worklist to MSU Houma.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 29 September 2005 Resolved
Place sign near galley range indicating location of stove disconnect switch.
Condition: Unknown
Due 30 October 2005
Resolved 9 November 2005
Resolution: Owner faxed completed worklist to MSU Houma.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 8 December 2004 Resolved
Provide FCC Radio Operators Permit.
Action required: 705 - Other - as specified
Due 9 January 2005
Resolved 6 February 2005
Resolution: FCC Operator Permit provided, Registraion #W00 55335
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 8 December 2004 Resolved
Install valve to the A/C drain line in A/C room, main deck prior to 09 FEB 2005.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 February 2005
Resolved 31 December 2006
Fire Fighting › Fire Pumps › Pressure
Issued 22 October 2003 Resolved
Show proper operation of fire pump to show 60 psi.
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 24 October 2003
Lifesaving › Lifebuoys
Issued 22 October 2003 Resolved
Renew life ring on bridge deck wing.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2003
Resolved 24 October 2003
Lifesaving › Lifebuoys
Issued 22 October 2003 Resolved
Renew life floats.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2003
Resolved 24 October 2003
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 22 October 2003 Resolved
Show proper operation of starboard MDE.
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 12 May 2004
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 22 October 2003 Resolved
Show proper operation of rudder angle indicator.
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 24 October 2003
Engineering › Pressure Vessel › Relief Valve
Issued 22 October 2003 Resolved
Show proper operation of the #1 and #2 pressure vessel relief valves.
Due 22 November 2003
Resolved 24 October 2003
Documentation › Certificates/Documents
Issued 22 October 2003 Resolved
Provide valid FCC bridge-to-bridge ships license. LEGACY COMPONENT DESC: FCC SSL
Due 22 November 2003
Resolved 24 October 2003
Construction/Loadline › Hull
Issued 6 March 2003 Resolved
Issued a Permit to Proceed to Marine Safety Unit, Houma, Louisiana area of operation to effect repairs IWO the forward peak starboard side, the bow thruster room starboard side, the forward section of the passenger compartment starboard side and the bulwark and deck area starboardside. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 6 April 2003
Resolved 9 October 2003
Engineering › Fuel Oil Service System › Valve, Control
Issued 19 February 2003 Resolved
Demonstrated proper operation of fuel cut off reach rods.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2003
Resolved 19 February 2003
Documentation › Markings/Placards
Issued 16 December 2002 Resolved
Provide Radio Broadcast Placard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 December 2002
Resolved 19 December 2002
Construction/Loadline › Structures
Issued 16 December 2002 Resolved
Free up foward escape hatch. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2002
Resolved 19 December 2002
Communications › Radio Communications
Issued 16 December 2002 Resolved
Demonstrate proper operations of all radios including VFH and single side band. LEGACY COMPONENT DESC: VFH Radiotelephone
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2002
Resolved 19 December 2002
Electrical › Lighting (emergency)
Issued 16 December 2002 Resolved
Provide another emergency light on stbd foward engine room.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2002
Resolved 19 December 2002
Electrical › Electric Generation Source (service)
Issued 16 December 2002 Resolved
Demosntrated proper operations of generator's overspeeds and reverse power. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2002
Resolved 19 December 2002

Casualty record · 2

6 March 2003Routine · role: Involved in a Marine Casualty · activity 1810421
31 December 2006Routine · role: Involved in a Marine Casualty · activity 2865555
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.