MAURY USCG vessel records Sign in
← All vessels

MAJESTIC STAR

MAJESTIC STAR is a 1997 passenger vessel (inspected). The Coast Guard has recorded 127 inspections since 1997, most recently in June 2024, along with 240 deficiencies and 4 casualty investigations between 2005 and 2015.

Records from 1997 to 2024. Most recent: inspection, 21 June 2024.

Built
1997
Last inspected
21 June 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8642933 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCX8072
461778
Flag
UNITED STATES
—
Maury page id
psix-461778

Inspections, by type

…with no type recorded29
Years with a record 15 calendar years (1997–2024)
The 127 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)320.5 ft × 76.0 ft × 20.0 ft
Registered tonnagegross 7,463 / net 6,902
ITC dimensions (L × B × D)320.5 ft × 76.0 ft × 20.0 ft
ITC tonnagegross 12,805 / net 4,056
BuilderATLANTIC MARINE INC · JACKSONVILLE, FL, UNITED STATES · built 1997
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7463 - Regulatory (Subpart C or D), Gross Ton
12805 - Convention (Subpart B), Gross Ton
6902 - Regulatory (Subpart C or D), Net Ton
4056 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 127

21 June 2024 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7939693
23 May 2024 Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7918198
12 September 2022 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7572030
21 March 2022 In-Service Inspection · Administrative Inspection · Load Line/Change of Employment
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7470695
20 July 2009 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3540641
11 May 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3472949
5 May 2009 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3468158
13 April 2009 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3450283
5 March 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3427891
18 February 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3420170
6 February 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3413753
6 February 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3414682
5 February 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3413542
23 January 2009 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3399070
2 December 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3372624
30 October 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3354186
9 October 2008 Plan Review (Other than "T") · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3337904
18 September 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3327224
30 July 2008 In-Service Inspection · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3284287
14 July 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3263411
22 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3213669
14 April 2008 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3181509
12 March 2008 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3183837
7 February 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3144059
17 January 2008 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3130287
13 December 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3116508
24 October 2007 Hull Examination
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3089100
11 October 2007 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3070960
30 July 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3012346
16 July 2007 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2992422
11 June 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2958316
18 May 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2936301
18 April 2007 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2906092
31 January 2007 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2863557
5 January 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2850795
16 October 2006 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2798444
25 August 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2759219
2 August 2006 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2738881
1 August 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2742664
21 June 2006 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2687096
14 June 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2688017
6 April 2006 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2624621
22 March 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2624607
15 February 2006 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2585863
26 October 2005 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2517591
3 October 2005 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2506982
26 July 2005 Plan Review (Other than "T") · Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2434593
21 April 2005 Periodic Inspection · Administrative Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2344064
7 March 2005 Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2305213
3 February 2005 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2281717
1 December 2004 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2247516
29 October 2004 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2223903
22 October 2004 Administrative Inspection · Deadweight Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2223887
11 August 2004 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2177577
28 July 2004 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2138041
21 July 2004 MTSA Verification · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2140687
10 June 2004 Security Plan Review - VSP
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2092341
8 June 2004 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2092195
7 May 2004 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2050894
3 May 2004 Construction Oversight
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2061728
23 February 2004 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2011625
4 February 2004 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1999680
24 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977950
13 November 2003 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1977400
29 October 2003 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1925587
27 August 2003 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1887601
1 August 2003 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1859431
30 April 2003 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1778221
24 January 2003 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1734021
10 January 2003 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1728672
17 October 2002 Internal Structural Exam · Underwater Inspection in lieu of Drydock · COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1690150
18 September 2002 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1677064
26 July 2002 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1648903
5 May 2002 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1747547
4 May 2002 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1680431
26 April 2002 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1606716
29 March 2002 Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1599075
28 January 2002 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1479980
8 November 2001 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1463000
22 October 2001 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1462276
12 October 2001 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1698357
26 July 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1451738
24 June 2001 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 30077
3 May 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1449474
25 April 2001 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 41171
26 January 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1415528
23 October 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 212121
23 October 2000 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1410424
26 July 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 822703
19 July 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 820654
19 June 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 818706
9 June 2000 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1420331
1 June 2000 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1430861
12 May 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1397428
30 March 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1048313
31 January 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1388989
22 December 1999 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 813453
7 December 1999 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 812885
24 November 1999 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1369424
25 October 1999 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1395290
2 October 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 110389
3 September 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 8918
11 August 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1372727
4 June 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 805136
10 May 1999 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1372715
25 February 1999 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 798271
1 February 1999 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1455672
26 October 1998 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1442765
17 August 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1368837
10 July 1998 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 151687
28 May 1998 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 791731
18 May 1998 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1125648
11 May 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1471682
1 May 1998 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1123888
10 April 1998 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 113324
16 February 1998 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 178792
26 January 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1386238
16 January 1998 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 65470
6 January 1998 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1120938
27 October 1997 Initial Certification · Deficiency Check · Deadweight Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1467039
9 October 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1109237
29 September 1997 Administrative
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1116479
27 September 1997 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1113053
22 September 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 62999
4 September 1997 Inclining Experiment · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 781333
2 September 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 757518
1 September 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 199376

Deficiency record · 240

Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 13 April 2009 Resolved
Update fire control plan to reflect proper location of portable fire extinguishers, specifically 4th deck, skydeck.
Due 15 May 2009
Resolved 11 May 2009
Resolution: fire control plan updated and scanned into doc/certs.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 April 2009 Resolved
Remove debris from behind ice maker and secure junction box on deck, below bar, service bar, 2nd deck.
Due 15 May 2009
Resolved 11 May 2009
Resolution: Junction box mounted properly.
Personnel › Training › Fire Fighting Basic
Issued 13 April 2009 Resolved
Ensure PSPs receive specific "Refuge Area" training in accordance with the approved Emergency Procedures Plan and are provided with a pamphlet summarizing evacuation procedures iaw NVIC 8-93.
Due 15 May 2009
Resolved 11 May 2009
Resolution: All PSP''s were issued a pamphlet and were quizzed on duties during emergencies, all sat.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 5 February 2009 Resolved
Provide onboard dedicated deckhands to serve all safety sensitive posititions on the vessels station bill.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2009
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 23 January 2009 Resolved
Prove proper operation of EOS alarm panel reset IAW 46CFR 113.05-7(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2009
Resolved 18 February 2009
Resolution: EOS tested sat.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 23 January 2009 Resolved
Properly identify and repair ground fault in #4 SSDG IAW 46 CFR 111.05.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2009
Resolved 18 February 2009
Resolution: Tech rep replaced diodes on #4 SSDG tested sat.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 23 January 2009 Resolved
Locate and make proper repairs to pilot house HVAC electrical. Locate ground.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2009
Resolved 18 February 2009
Resolution: Ground fault tested sat.
Communications › Audible Communications › Horn/Whistle
Issued 23 January 2009 Resolved
Make proper repairs to pressure relief valve for horns air receiver.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2009
Resolved 18 February 2009
Resolution: Pressure relief valve inspected sat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 January 2009 Resolved
Under 2nd deck midship bar make proper repairs to electrical box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2009
Resolved 18 February 2009
Resolution: Electrical outlet installed properly.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 23 January 2009 Resolved
Install proper electrical outlets iwo 2nd deck midship (port) stage. Remove daisy chained surge protectors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2009
Resolved 18 February 2009
Resolution: Electrical box installed to replace daisy chain surge protectors.
Fire Fighting › Structural - A Class Divisions › Store-rooms
Issued 14 April 2008 Resolved
Renew insullation, fwd port blkhd, Slot Stowage compartment.
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 14 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2008 Resolved
Provide additional power/AC outlets as needed in Slot Stowage space (presence of daisy chained pwr strips).
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 14 July 2008
Construction/Loadline › Structures › Superstructure
Issued 14 April 2008 Resolved
Make Pilot [name withheld] weather tight iwo seam, forward slope.
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 14 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2008 Resolved
Remove daisy chained extension cords, port side PFD stowage locker, 03 deck (forward).
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 14 July 2008
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 14 April 2008 Resolved
Remove/re-stow supplies/combustibles in Pilot [name withheld] and Slot Stowage Space.
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 14 July 2008
Lifesaving › Immersion Suits › Serviceable
Issued 14 April 2008 Resolved
Provide proposal for servicing/testing immersion suits iaw NVIC 08-01.
Due 14 May 2008
Resolved 14 July 2008
Resolution: Immersion suits were renewed vice repaired.
Stability › Watertight Integrity › General
Issued 17 January 2008 Resolved
Demonstrate proper operation of WTD #17 bridge indicator light.
Due 17 February 2008
Resolved 7 February 2008
Navigation › Piloting/Steering › Gyro Compass
Issued 17 January 2008 Resolved
Demonstrate proper operation of vsl gyrocompass.
Due 17 February 2008
Resolved 7 February 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 17 January 2008 Resolved
Properly label UPS Power Panel #5 (surveillance room).
Due 17 February 2008
Resolved 7 February 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 January 2008 Resolved
Provide/post copy of approved fireplan @ each entrance and on brigde, and elsewhere currently posted.
Due 5 May 2008
Resolved 2 December 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 January 2008 Resolved
Organize/clean port aft 4 deck surveillence stowage, Project Crew stowage, and bar/service areas.
Due 17 February 2008
Resolved 14 April 2008
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 October 2007 Resolved
Make records available to provide proof of compliance with 46 CFR 16, and 16.260 to include MIS reports.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 13 December 2007
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 11 October 2007 Resolved
Remove all Fire Hazards/Trash from the slot tech managers office and remove coffee maker from under the desk.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 November 2007
Resolved 13 December 2007
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 11 October 2007 Resolved
Make repairs to the alarm panel in control room, alarm displays alarm properly, but must be acknowledged by removing circuit board..
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 November 2007
Resolved 13 December 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 July 2007 Resolved
Remove curtain from lifejacket locker main deck forward, port side.
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 13 December 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 July 2007 Resolved
Move table game so lifejacket locker door can open completely, unobstructive in the baccarat room, port side.
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 13 December 2007
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 16 July 2007 Resolved
Escalator hand rails showing signs of wear with some areas creating sharp spirs.
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 13 December 2007
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 18 April 2007 Resolved
Find and clear ground on the T4 transformer.
Condition: Unknown
Due 18 May 2007
Resolved 18 May 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 January 2007 Resolved
Renew all weathered ring buoy lifelines and waterlight lanyards.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2007
Resolved 18 May 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 January 2007 Resolved
Prove proper operation of the forward mast light in primary mode.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2007
Resolved 18 May 2007
Engineering › Bilge Water Management System › Pump
Issued 31 January 2007 Resolved
Prove proper operation of bilge pump #3.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2007
Resolved 18 May 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 31 January 2007 Resolved
Ensure master has access to all locked spaces (IGC room)
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2007
Resolved 18 May 2007
Lifesaving › Launching Appliances › Davit
Issued 16 October 2006 Resolved
Repair rescue boat cradle to provide sufficient strength during recovery operations.
Action required: 705 - Other - as specified
Due 16 November 2006
Resolved 5 January 2007
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 23 August 2006 Resolved
Update Emergency plans with location of child lifejackets.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 September 2006
Resolved 5 January 2007
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 23 August 2006 Resolved
Make child life jackets readily accessible.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2006
Resolved 5 January 2007
Lifesaving › Lifebuoys › Serviceable
Issued 2 August 2006 Resolved
Renew Ring Bouys on the 4th deck port and starboard side per 46 CFR 199.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2006
Resolved 23 August 2006
Resolution: New life buoys installed on 4th deck port and starboard.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 2 August 2006 Resolved
Provide thermometers for all refers per 46 CFR 71.45-1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 September 2006
Resolved 23 August 2006
Resolution: New thermometers installed in refers.
Lifesaving › Rescue Boat › Construction
Issued 2 August 2006 Resolved
Repair or renew sternlight on the port rescue boat per nav rule 23.
Condition: Improper/Lack of Maintenance
Due 2 September 2006
Resolved 23 August 2006
Resolution: New sternlight installed on rescue boat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 August 2006 Resolved
Segragate child PFD's from adult in 3rd deck port locker. per 46 CFR 199.70 and label with proper count.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 September 2006
Resolved 5 January 2007
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 2 August 2006 Resolved
Remove all mesh trash cans and provide type in compliance with 46 CFR 72.05.55(b)
Condition: Placed in Improper Service
Due 2 September 2006
Resolved 23 August 2006
Resolution: Trash cans removed from ladder well, and new provided.
Fire Fighting › Fire Hydrants › Condition
Issued 2 August 2006 Resolved
Replace cracked glass at fire stations 12 and 23 per 46 CFR 71.30-5.
Condition: Unknown
Due 2 September 2006
Resolved 23 August 2006
Resolution: Glass on fire stations 12 and 23 replaced.
Engineering › Electric Propulsion System › Transformer Circuitry
Issued 2 August 2006 Resolved
Prove proper operation of all Z-drive control units per 46 cfr 58.05
Condition: Unknown
Due 2 September 2006
Resolved 23 August 2006
Resolution: Tested Z-Drive for proper operation and alarms.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 2 August 2006 Resolved
Prove proper operation of fire damper No. 8 and 9 located on the 3rd deck per 46 CFR 72.05-50.
Condition: Improper/Lack of Maintenance
Due 2 September 2006
Resolved 23 August 2006
Resolution: Witnessed proper operation of fire dampers.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 1 May 2006 Resolved
33U.S.C.1321(j)(5)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge 33U.S.C.1321(j)(5)(D)(i)-The NTVRP does not identify the volume and type of fuel oil that would be involved in a worst case discharge
Due 1 June 2006
Resolved 30 June 2009
Resolution: The VRP program received a satisfactory response to the deficiency letter dated 05/01/2006. Vessel issued Interim Operating Authorization expiring 06/30/2011.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (air intake)
Issued 6 April 2006 Resolved
Renew No. 2 generator engine block heater with hose and fittings in compliance with SAE J-1492.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 May 2006
Resolved 14 June 2006
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 6 April 2006 Resolved
Clear all stray current problems from hull grounds on detectors for transformer T-1, T-3, and T-4.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2006
Resolved 14 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 April 2006 Resolved
Remove Dead end wiring and chaffed wiring on the inboard side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 May 2006
Resolved 14 June 2006
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 6 April 2006 Resolved
Obtain proper test equipment to complete automation tests of SCR no. 2 per 46 CFR No. 2
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 May 2006
Resolved 14 June 2006
Fire Fighting › Ventilation Systems › Stairway Enclosure Ventilation
Issued 15 February 2006 Resolved
Ensure all dampner brackets are properly secured to the bulkheads.
Action required: 705 - Other - as specified
Due 10 March 2006
Resolved 22 March 2006
Resolution: Sighted this date.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 15 February 2006 Resolved
Ensure beverage reefer latch is replaced or fixed.
Action required: 705 - Other - as specified
Due 10 March 2006
Resolved 22 March 2006
Resolution: Sighted this date
Communications › Internal Communications System › Sound-powered Telephone
Issued 15 February 2006 Resolved
Sound powered telephone needs to be replaced or fixed.
Action required: 705 - Other - as specified
Due 10 March 2006
Resolved 22 March 2006
Resolution: Sighted this date.
Engineering › Generator (propulsion/auxiliary-electric) › Reverse Power Protection Relay Circuitry
Issued 26 October 2005 Resolved
Prove proper operation operation of #2 SSDG. System is currently not excepting load. Must also prove reverse power relay is working properly for #2 SSDG.
Due 26 November 2005
Resolved 31 October 2005
Resolution: Witnessed sat test of #2 SSDG under load this date. Also reverse power relay working properly. CWO4 D.E.Majors
Documentation › Manifests/Lists › Dangerous Goods Manifest/Stowage Plan
Issued 26 October 2005 Resolved
Conduct inventory of all storage lockers containing chemicals and provide the appropiate MSDS for the chemicals stored in the lockers. Must meet the satisfaction of the attending inspector.
Due 26 November 2005
Resolved 22 December 2005
Resolution: Accepted Master affadavit as to completion this date. CWO4 D.E.Majors
Lifesaving › Rescue Boat › Hull (inflated)
Issued 26 July 2005 Resolved
Renew pontoon on port side rescue boat. 09 Aug 2005: Stbd side boat switched to port side as interim measure. Parts on order to make repairs to former port side boat. Requirement extended to 30 September, 2005.
Due 30 September 2005
Resolved 16 September 2005
Resolution: Sighted replacement pontoons in place. all sat. CWO4 D.E.Majors
Communications › Alarms/Indicators › Propeller Direction Indicator
Issued 26 July 2005 Resolved
Prove proper operation of stbd forward Z-drive direction indicator in E.O.S. (bridge repeater works normally).
Due 23 August 2005
Resolved 9 August 2005
Resolution: Cleared upon receipt of affadavit from [name withheld]4 D.E.Majors
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 July 2005 Resolved
Renew stbd forward & aft 4th deck lifering grab lines.
Due 23 August 2005
Resolved 9 August 2005
Resolution: Cleared upon receipt of affadavit from [name withheld]4 D.E.Majors
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 21 April 2005 Resolved
Prove proper operation of door closer for #2 FSD.
Due 27 May 2005
Resolved 31 May 2005
Resolution: Witnessed sat test of door. CWO4 D.E.Majors
Engineering › Electric Propulsion System › Wiring
Issued 21 April 2005 Resolved
(actually not wiring, but proper selection does not exist) Prove proper operation of #4 Schottle drive cooling fan
Due 27 May 2005
Resolved 31 May 2005
Resolution: Witnessed sat test of drive cooling fan this date. CWO4 D.E.Majors
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 21 April 2005 Resolved
Replace missing A-60 insulation in forward mooring flat and surveillance equipment storage cage.
Due 27 May 2005
Resolved 31 May 2005
Resolution: Sighted installation of replaced A-60 insulation, all sat this date. CWO4 D.E.Majors
Electrical › Electric Generation Source (service) › Generator
Issued 7 March 2005 Resolved
Upon completion of repairs to the No. 4 ship service generator, make generator available for inspection and 100% rated load test to the satisfaction of the attending marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 September 2005
Resolution: Observed proper operation and testing of all vital functions and safety tests with the exception of reverse power, which was not done due to the presence of passengers onboard and possiblity of losing power unexpectedly. CWO4 D.E.Majors
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 October 2004 Resolved
Install new E-Light Placards on 03 Deck - 2 Amidship, 2 Main Deck Fwd, 1 Hold, 1 in Thruster Room.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Resolution: Installed new E-Light Placards.
Electrical › Electrical Distribution System (emergency) › Outlet Box
Issued 29 October 2004 Resolved
Ensure all data outlet covers are installed.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 29 October 2004 Resolved
Cap Open Outlet Box in Soft Count Area.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 October 2004 Resolved
Ensure all wires in overhead of hold deck are properly run in wire runs, esp. in surveillence.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 29 October 2004 Resolved
Ensure clear access to all circuit breakers and electrical panels.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Resolution: Trash cans and tables that were blocking access to circuit breakers and electrical panels removed, all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 October 2004 Resolved
Remove or properly terminate dead end wire in fwd mooring hold
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Resolution: Dead end wire properly terminated into a junction box.
Fire Fighting › Structural - A Class Divisions › Open Deck Spaces
Issued 29 October 2004 Resolved
In HVAC Room below the Bridge repair and replace the insullation and thru hull packings.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 29 October 2004 Resolved
Remove plastic trash cans from office hold area.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Resolution: Platic trash can was removed.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 29 October 2004 Resolved
Renew all A-60 insullation in soft count, food bev storage, fwd mooring flat, and fwd hvac room.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 29 October 2004 Resolved
General Housekeeping in hold offices ensure combustable materials are at a minimum,
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Resolution: Hold offices cleaned and in good order.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 29 October 2004 Resolved
Ensure #1 Sprinkler Pump Differential Switch is operational. A dedicated watch is to be posted until automation is active.
Action required: 705 - Other - as specified
Due 1 December 2004
Resolved 1 December 2004
Resolution: Cleared by [name withheld] within twenty four hours of the inspection.
Construction/Loadline › Structures › Door
Issued 29 October 2004 Resolved
Repair interior below W.T.D #10 on edge.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Resolution: W.T.D #10 repaired, all sat.
Engineering › Electric Propulsion System › Remote Control Circutry
Issued 29 October 2004 Resolved
Ensure all motor controllers are properly labeled.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Resolution: Motor controllers properly labeled.
Lifesaving › Buoyant Apparatus › Marking
Issued 29 October 2004 Resolved
Ensure all Liferings are properly labeled with full name and homeport.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 29 October 2004 Resolved
Clean under counters and sinks in all food and beverage areas.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Resolution: The under counters and sinks viewed all sat.
Construction/Loadline › Structures › Superstructure
Issued 29 October 2004 Resolved
Repair cracked window on 03 deck port amidships.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 1 December 2004
Resolution: Specialty window ordered and cut, will call when installed.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 28 July 2004 Resolved
Post EAP "800" number
Due 4 September 2004
Resolved 11 August 2004
Resolution: Sighted this date
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 July 2004 Resolved
Straighten out wiring messes in all cash cages
Due 4 September 2004
Resolved 11 August 2004
Resolution: Sighted this date
Engineering › Electric Propulsion System › Circuit Breaker (overload/over current protection)
Issued 28 July 2004 Resolved
Prove proper operation of #3 SCR emergency stop switches in both bridge and E.O.S.
Due 4 September 2004
Resolved 11 August 2004
Resolution: Sighted this date.
Fire Fighting › Automatic Sprinkler System › Pump
Issued 28 July 2004 Resolved
Prove proper operation of #1 sprinkler pump control
Due 11 August 2004
Resolved 11 August 2004
Resolution: Sighted this date.
Construction/Loadline › Structures
Issued 7 May 2004 Resolved
Correct hydraulic leak on WTD #4 @ hand pump LEGACY COMPONENT DESC: Door
Due 7 May 2004
Resolved 3 June 2004
Resolution: Cleared upon receipt of affadavit from vessel Master.
Electrical › Electrical Distribution System (service)
Issued 7 May 2004 Resolved
Clean up slot bank wiring on main deck (in "carousels")
Due 7 May 2004
Resolved 3 June 2004
Resolution: Cleared upon receipt of affadavit from vessel Master
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 7 May 2004 Resolved
Renew refrigerator seals throughout vessel as required
Due 7 May 2004
Resolved 3 June 2004
Resolution: Cleared upon receipt of affadavit from vessel Master.
Accommodation/Occupational Safety › Messroom
Issued 7 May 2004 Resolved
Clean under 2nd deck service bar
Due 7 May 2004
Resolved 3 June 2004
Resolution: Cleared upon receipt of affadavit from vessel Master.
Fire Fighting › Automatic Sprinkler System
Issued 7 May 2004 Resolved
Renew damaged pressure gauge for sprinkler pump in Auxiliary Machinery space LEGACY COMPONENT DESC: Pressure Gauges
Due 7 May 2004
Resolved 3 June 2004
Resolution: Cleared upon receipt of affadavit from vessel Master.
Electrical › Electric Supply System (service)
Issued 7 May 2004 Resolved
Correct grounds (shown in three of four main circuits) in electrical system
Due 7 May 2004
Resolved 3 June 2004
Resolution: Cleared upon receipt of affadavit from vessel Master.
Construction/Loadline › Structures
Issued 7 May 2004 Resolved
Prove proper opening of W/T Door #5 LEGACY COMPONENT DESC: Door
Due 7 May 2004
Resolved 3 June 2004
Resolution: Cleared upon receipt of affadavit from vessel Master.
Fire Fighting › Structural - A Class Divisions
Issued 7 May 2004 Resolved
Prove proper operation of Fire Screen Door #34 LEGACY COMPONENT DESC: Openings - Fire Doors
Due 7 May 2004
Resolved 3 June 2004
Resolution: Cleared upon receipt of affadavit from vessel Master.
Fire Fighting › Means of Escape
Issued 23 February 2004 Resolved
Make hard count secondary exit usable by hand (keyless) from inside of space without any outside intervention. In the interim, key is to be kept within the hard count room and door kept ready to be opened with key only. LEGACY COMPONENT DESC: Doorways
Due 26 March 2004
Resolved 24 March 2004
Resolution: Cleared upon receipt of affadavit from [name withheld]4 D.E.Majors
Fire Fighting › Structural - Main Vertical Zones
Issued 4 February 2004 Resolved
Prove proper operation of fire screen doors #43, 32, & 2 (43 release switch inoperative, 32 & 2 do not close completely)
Due 4 March 2004
Resolved 26 February 2004
Resolution: Sighted proper operation this date. CWO4 D.E.Majors
Fire Fighting › Means of Escape
Issued 4 February 2004 Resolved
Remove obstuctions from both sides of door between hard count & coin vault. Mark as "exit, keep clear" (or words to that effect). LEGACY COMPONENT DESC: Doorways
Due 4 March 2004
Resolved 26 February 2004
Resolution: Sighted this date. Noted that route is still impeded. Issued modifed CG-835. Cleared this one. CWO4 D.E.Majors
Fire Fighting › Automatic Sprinkler System
Issued 4 February 2004 Resolved
Clean paint from or renew sprinkler heads in the overhead dome of the third deck forward signature room. LEGACY COMPONENT DESC: Sprinklers
Due 4 March 2004
Resolved 26 February 2004
Resolution: Sighted this date CWO4 D.E.Majors
Fire Fighting › Combustible Materials
Issued 4 February 2004 Resolved
Remove excess combustible materials (paper, cardboard, etc.) throughout hold deck (particular attention to slot office, HVAC room, & forward mooring flat).
Due 4 March 2004
Resolved 26 February 2004
Resolution: Sighted this date. CWO4 D.E.Majors
Stability › Watertight Integrity
Issued 4 February 2004 Resolved
Seal deck penetration below main deck service bar
Due 4 March 2004
Resolved 26 February 2004
Resolution: Sighted this date. CWO4 D.E.Majors
Electrical › Electrical Distribution System (service)
Issued 4 February 2004 Resolved
Replace missing electrical box covers in elevator shafts (3 in passenger elevator, 1 in service elevator) LEGACY COMPONENT DESC: Outlet Box
Due 4 March 2004
Resolved 26 February 2004
Resolution: Sighted this date. [name withheld]
Fire Fighting › Combustible Materials
Issued 4 February 2004 Resolved
Clean up hydraulic oil and oil soaked materials in elevator machinery room (much of it behind hydraulic supply tank on deck).
Due 4 March 2004
Resolved 26 February 2004
Resolution: Sighted this date. CWO4 D.E.Majors
Electrical › Electrical Distribution System (service)
Issued 4 February 2004 Resolved
Remove dead-end wire in port side z-drive room on side shell LEGACY COMPONENT DESC: Cable
Due 4 March 2004
Resolved 26 February 2004
Resolution: Sighted this date. CWO4 D.E.Majors
Lifesaving › Lifebuoys
Issued 4 February 2004 Resolved
Re-label life ring, port side forward e.s.s. LEGACY COMPONENT DESC: Markings (ship name/port)
Due 4 March 2004
Resolved 26 February 2004
Resolution: Sighted this date CWO4 D.E.Majors
Electrical › Electrical Distribution System (service)
Issued 4 February 2004 Resolved
Mount electrical box, 3rd deck aft LEGACY COMPONENT DESC: Outlet Box
Due 4 March 2004
Resolved 26 February 2004
Resolution: Sighted this date. CWO4 D.E.Majors
Documentation › Markings/Placards
Issued 4 February 2004 Resolved
Re-mount garbage placard in hold (employee break room) LEGACY COMPONENT DESC: Garbage Placard
Due 4 March 2004
Resolved 26 February 2004
Resolution: Sighted this date. CWO4 D.E.Majors
Fire Fighting › Ventilation Systems
Issued 4 February 2004 Resolved
Mark remote engine room ventilation shutdowns to indicate direction of operation LEGACY COMPONENT DESC: Operating Controls
Due 4 March 2004
Resolved 26 February 2004
Resolution: Sighted this date. CWO4 D.E.Majors
Fire Fighting › Means of Escape
Issued 4 February 2004 Resolved
Mark escapes on both port & stbd sides of top deck "tent" to indicate proper route. (follow-up 04/06/04 telecons, [name withheld]/[name withheld], CHIMS request copy of letter approving structure) LEGACY COMPONENT DESC: Escape Route Signs
Due 4 March 2004
Resolved 26 February 2004
Resolution: Sighted this date. CWO4 D.E.Majors
Accommodation/Occupational Safety › Occupational Safety
Issued 4 February 2004 Resolved
Renew aluminum ramp into beer cooler (very unstable, major tripping hazard)
Due 4 March 2004
Resolved 26 February 2004
Resolution: Was replaced with steel ramp. Sighted this date. CWO4 D.E.Majors
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 October 2003 Resolved
Determine which lights currently marked as emergency lighting should be so marked and prove proper operation.
Action required: 705 - Other - as specified
Due 13 November 2003
Resolved 13 November 2003
Operations/Management › Vessel Safety Management
Issued 29 October 2003 Resolved
ENSURE ALL REQUIRED MSD SHEETS ARE IN BOOKS, BETTER ORGANIZE SAME, AND THAT THEY ARE READILY AVAILABLE TO LOCATIONS WHERE CHEMICALS ARE STORED. LEGACY COMPONENT DESC: Documentation Maintenance/Control
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2003
Resolved 17 November 2003
Resolution: Sighted MSD books. Both organization and accessibility is greatly improved.
Electrical › Electrical Distribution System (service)
Issued 29 October 2003 Resolved
REPLACE MISSING ELECTRICAL BOX COVER IN EMPLOYEE ELEVATOR PIT. LEGACY COMPONENT DESC: Junction Box
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 November 2003
Resolved 17 November 2003
Resolution: Sighted cover in place. Cleared requirement.
Electrical › Electrical Distribution System (service)
Issued 29 October 2003 Resolved
RENEW MALFUNTIONING HEATER CONTROLLER IN PILOT HOUSE VOID. LEGACY COMPONENT DESC: Switch
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2003
Resolved 17 November 2003
Resolution: Sighted newly installed heater controller in operation. All sat. CWO4 D.E.Majors
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 29 October 2003 Resolved
REPLACE SPRINKLER PUMP SUCTION DISCHARGE TAMPER VALVE INDICATORS
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 November 2003
Resolved 12 November 2003
Fire Fighting › Structural - A Class Divisions
Issued 29 October 2003 Resolved
REPLACE OVERHEAD INSULATION THAT IS MISSING IN THE FORPEAK AREA. LEGACY COMPONENT DESC: Bulkheads - Aux Spaces (moderate fire risk)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 November 2003
Resolved 17 November 2003
Resolution: Sighted insulation in place this date. CWO4 D.E.Majors
Communications › Alarms/Indicators
Issued 29 October 2003 Resolved
LABEL GENERAL ALARM LIGHTS IN AFT Z DRIVE SPACE. LEGACY COMPONENT DESC: General Alarm
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2003
Resolved 17 November 2003
Resolution: Sighted labelling this date. All sat. CWO4 D.E.Majors
Documentation › Safety/Response Plans/Programs
Issued 1 August 2003 Resolved
Update and submit for approval to OCMI vessel fire safety plan per 46 CFR 78.45-1 LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Due 1 September 2003
Resolved 27 August 2003
Resolution: reviewed plans. found a number of areas that need to be corrected on new plan.
Fire Fighting › Structural - A Class Divisions
Issued 1 August 2003 Resolved
Remove all flammable expanding foam insulation in bulkhead penetrations in all A-60 bulkheads, and re-insulate per NVIC 9-97. Re-install all cut out insulation in the bow thruster space.
Condition: Improper Installation
Due 1 September 2003
Resolved 27 August 2003
Communications › Alarms/Indicators
Issued 1 August 2003 Resolved
Correct General Alarm recording static problem. LEGACY COMPONENT DESC: General Alarm
Condition: Design Flaw
Due 1 September 2003
Resolved 27 August 2003
Accommodation/Occupational Safety › Ventilation
Issued 1 August 2003 Resolved
Clean all vents and ducts in Casino areas.
Condition: Improper/Lack of Maintenance
Due 1 September 2003
Resolved 27 August 2003
Lifesaving › Hand Flares
Issued 1 August 2003 Resolved
Renew all Flares. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 1 September 2003
Resolved 27 August 2003
Communications › Alarms/Indicators
Issued 1 August 2003 Resolved
Properly label all General Alarm beacons per 46 CFR 78.47-7. LEGACY COMPONENT DESC: General Alarm
Condition: Improper Installation
Due 1 September 2003
Resolved 27 August 2003
Fire Fighting › Structural - Main Vertical Zones
Issued 24 January 2003 Resolved
Prove proper operation of fire-screen doors, #34, 43, 25, 19, 8, & 16 First extension 2/21/03 parts on order for door #25. CWO3 D.E.Majors
Due 24 March 2003
Resolved 17 March 2003
Resolution: Cleared upon receipt of affadavit from vessel Master attesting that repairs had been completed. CWO3 D.E.Majors
Accommodation/Occupational Safety › Occupational Safety
Issued 24 January 2003 Resolved
Place signage for hearing protection, provide hearing protection in hard count room.
Due 24 February 2003
Resolved 21 March 2003
Resolution: Cleared upon receipt of affadavit from [name withheld]
Accommodation/Occupational Safety › Occupational Safety
Issued 24 January 2003 Resolved
Place MSDS catalogs in both men's and women's hold deck heads and 2nd deck storage locker.
Due 24 February 2003
Resolved 21 March 2003
Resolution: Cleared upon receipt of affadavit from [name withheld]
Operations/Management › Passenger Operations
Issued 24 January 2003 Resolved
Clean under 1st deck bar ice machine
Due 24 February 2003
Resolved 21 March 2003
Resolution: Cleared upon receipt of affadavit from [name withheld]
Operations/Management › Passenger Operations
Issued 24 January 2003 Resolved
Provide closable containers for mixers in all bars (open containers of juices, milk, etc. noted this date, both in refrigerators and standing out unrefrigerated).
Due 24 February 2003
Resolved 21 March 2003
Resolution: Cleared upon receipt of affadavit from [name withheld]
Fire Fighting › Combustible Materials
Issued 24 January 2003 Resolved
Clean behind slot machines, 2nd deck forward.
Due 24 February 2003
Resolved 21 March 2003
Resolution: Cleared upon receipt of affadavit from [name withheld].
Electrical › Electrical Distribution System (service)
Issued 17 October 2002 Resolved
MAKE REPAIRS TO BREAKER FOR #3 SCR. (Z-DRIVE) LEGACY COMPONENT DESC: Circuit Breaker
Action required: 705 - Other - as specified
Due 1 November 2002
Resolved 6 November 2002
Resolution: Cleared upon receipt of affadavit from vessel Master, [name withheld] as to completion.
Engineering › Electric Propulsion System
Issued 17 October 2002 Resolved
TRACE AND REPAIR "GHOST" RPM'S INDICATED FOR #4 SCR. LEGACY COMPONENT DESC: Other
Action required: 705 - Other - as specified
Due 12 November 2002
Resolved 6 November 2002
Resolution: Cleared upon receipt of affadavit from vessel Master, [name withheld] as to completion.
Accommodation/Occupational Safety › Occupational Safety
Issued 26 July 2002 Resolved
Remove unnecessary materials being stored in HVAC rooms.
Due 26 August 2002
Resolved 26 August 2002
Resolution: Cleared upon receipt of affadavit from [name withheld] attesting that work has been completed.
Stability › Weathertight Integrity
Issued 26 July 2002 Resolved
Renew gaskets on weathertight entryway doors (main passenger & VIP entrances).
Due 26 September 2002
Resolved 20 September 2002
Resolution: Cleared upon receipt of affadavit from vessel Master, [name withheld]
Electrical › Electric Generation Source (emergency) › Switch
Issued 26 April 2002 Resolved
Prove proper operation of emergency generator switchgear. Currently unreliable although switch did close automatically after being exercised repeatedly manually.
Due 28 April 2002
Resolved 27 April 2002
Resolution: Switchgear disassembled and cleaned. Tested twice in presence of Marine Inspector. All sat.
Lifesaving
Issued 8 November 2001 Resolved
PROVE PROPER OPERATION OF OUTBOARD MOTORS ON BOTH RESCUE BOATS. BOATS WILLBE MANUALLY PROPELLED AS NEEDED IN INTERIM.
Condition: Unknown
Due 20 November 2001
Resolved 26 November 2001
Documentation
Issued 23 October 2000 Resolved
Provide proof that all vsl personnel have current/valid/original Merchant Marine Documents (MMD) in their possession while employeed on board vessel,to the satisfaction of the attending marine inspector and cognizant OCMI.
Condition: Unknown
Due 23 November 2000
Resolved 21 November 2000
Electrical
Issued 23 October 2000 Resolved
Provide and install proper stuffing tube/rox blocks plugs for openings in deck behind PA Panel on bridge and in pilot house void deck under bridge, to the satisfaction of the attending marine inspector and cognizant OCMI.
Condition: Unknown
Due 23 November 2000
Resolved 21 November 2000
Documentation
Issued 23 October 2000 Resolved
Provide proof of all vessel personnel being enrolled in drug & alcohol pro-gram and provide complete documentation of the same and vessel's program, to the satisfaction of the attending marine inspector and cognizant OCMI.
Condition: Unknown
Due 23 November 2000
Resolved 21 November 2000
Lifesaving
Issued 23 October 2000 Resolved
Provide proof of life jackets being available for persons under 90lbs of weight, to the satisfaction of the attending marine inspector and cognizantOCMI.
Condition: Unknown
Due 23 November 2000
Resolved 21 November 2000
Accommodation/Occupational Safety
Issued 23 October 2000 Resolved
Properly repair failing reefer decking, to the satisfaction of the attend- ing marine inspector and cognizant OCMI.
Condition: Unknown
Due 23 December 2000
Resolved 21 November 2000
Electrical
Issued 23 October 2000 Resolved
Properly mount all loose/hanging electrical outlet boxes located in the fwdZ-Drive compartment, to the satisfaction of the attending marine inspector and cognizant OCMI.
Condition: Unknown
Due 6 November 2000
Resolved 30 October 2000
Electrical
Issued 23 October 2000 Resolved
Properly plug open/missing circuit blanks located in fwd Z-Drive compart- ment power panel, to the satisfaction of the attending marine inspector andcognizant OCMI.
Condition: Unknown
Due 6 November 2000
Resolved 30 October 2000
Electrical
Issued 23 October 2000 Resolved
Properly mount all electircal power strips & neatly bundle/route all wiringlocated in all office spaces, all cages/pit areas and in bridge PA System storage cabinets located on the bridge, to the satisfaction of the attend- ing marine inspector and cognizant OCMI.
Condition: Unknown
Due 6 November 2000
Resolved 30 October 2000
Fire Fighting
Issued 23 October 2000 Resolved
Weigh all CO2 fixed system bottles in the presence of a Marine Inspector.
Condition: Unknown
Due 21 November 2000
Resolved 30 October 2000
Fire Fighting
Issued 23 October 2000 Resolved
Provide operating directions for the engine room and emergency generator room CO2 system.
Condition: Unknown
Due 28 November 2000
Resolved 28 November 2000
Electrical
Issued 23 October 2000 Resolved
Provide manual reset device for all heaters.
Condition: Unknown
Due 28 November 2000
Resolved 28 November 2000
Engineering
Issued 23 October 2000 Resolved
Repair emergency generator F/O tank emergency securing valve ensuring that it closes properly.
Condition: Unknown
Due 21 November 2000
Resolved 30 October 2000
Fire Fighting
Issued 23 October 2000 Resolved
Repair #1 fixed fire-fighting pump.
Condition: Unknown
Due 21 November 2000
Resolved 30 October 2000
Fire Fighting
Issued 23 October 2000 Resolved
Provide servicing report for portable fire extinguishers and replace all August tags with October tags once extinguishers have been re-serviced.
Condition: Unknown
Due 21 November 2000
Resolved 30 October 2000
Fire Fighting
Issued 23 October 2000 Resolved
Prove proper operation of sprinkler tank pressure alarms, level alarms and flow alarms. Testing of all eleven-fire zones shall be conducted by opening test stations or removing heads to ensure alarms are operational.
Condition: Unknown
Due 14 December 2000
Resolved 14 December 2000
Electrical
Issued 23 October 2000 Resolved
Remove excessive wiring, properly mount electrical boxes, remove installed extension cords in the bow & stern Z-drive compartments and in the engine room inboard of F/O filters.
Condition: Unknown
Due 21 November 2000
Resolved 30 October 2000
Fire Fighting
Issued 23 October 2000 Resolved
Provide and mount portable fire extinguisher in the stbd aft Z-drive compartment.
Condition: Unknown
Due 21 November 2000
Resolved 30 October 2000
Fire Fighting
Issued 23 October 2000 Resolved
Provide servicing report for fire detection systems.
Condition: Unknown
Due 14 December 2000
Resolved 14 December 2000
Electrical
Issued 23 October 2000 Resolved
Repair or replace emergency generator kW meter.
Condition: Unknown
Due 28 November 2000
Resolved 28 November 2000
Fire Fighting
Issued 23 October 2000 Resolved
Provide proof that all dry chemical portable fire extinguisher hoses have been rechecked and tightened as needed, to the satisfaction of the attend- ing marine inspector and cognizant OCMI.
Condition: Unknown
Due 23 November 2000
Resolved 30 October 2000
Fire Fighting
Issued 23 October 2000 Resolved
Reinstall all missing ceiling tiles in the followin locations; 2nd deck janitor locker, survielence office, employee entrance at stbd ladder well leading to hold deck, to the satisfaction of the attending marine inspectorand cognizant OCMI.
Condition: Unknown
Due 23 November 2000
Resolved 30 October 2000
Fire Fighting
Issued 23 October 2000 Resolved
Prove proper operation of fire screen doors #6 & #12, to the satisfaction of the attending marine inspector and cognizant OCMI.
Condition: Unknown
Due 23 November 2000
Resolved 30 October 2000
Electrical
Issued 23 October 2000 Resolved
Properly label all emergency lighting systems/lights throughout hold deck office spaces, to the satisfaction of the attending marine inspector and cognizant OCMI.
Condition: Unknown
Due 6 November 2000
Resolved 30 October 2000
Documentation
Issued 23 October 2000 Resolved
Provide proof that all IBA operators have been trained in their duties and that documentation for the same is available for Coast Guard inspection on the vessel, to the satisfaction of the attending marine inspector and cog- nizant OCMI.
Condition: Unknown
Due 23 November 2000
Resolved 21 November 2000
Construction/Loadline
Issued 12 May 2000 Resolved
Sliding WT doors #1, 3, & 4 are to remain closed at all times when underwayexcept when personnel are actually passing through._x001C_ (All three failed and can only be actuated with hand crank.)
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Construction/Loadline
Issued 12 May 2000 Resolved
Correct sticking problem with WT door #17
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Accommodation/Occupational Safety
Issued 12 May 2000 Resolved
Clean all bar areas to satisfaction of attending Marine Inspector.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Construction/Loadline
Issued 31 January 2000 Resolved
Prove proper operation of water tight door control room indicator panel at frame 75.
Condition: Unknown
Due 31 January 2000
Resolved 31 January 2000
Fire Fighting
Issued 31 January 2000 Resolved
Prove proper operation of tamper switches and cross over valve for zone 9.
Condition: Unknown
Due 31 January 2000
Resolved 31 January 2000
Lifesaving
Issued 31 January 2000 Resolved
Provide training materials, records and conduct drill in accordance with 199.180 and 199.250
Condition: Unknown
Due 31 January 2000
Resolved 31 January 2000
Electrical
Issued 31 January 2000 Resolved
Repair various electrical problems behind all pit stations and under all gamming tables. Mount electric boxes, reroute cable so that cable cannot be stepped on, etc.
Condition: Unknown
Due 31 January 2000
Resolved 31 January 2000
Lifesaving
Issued 31 January 2000 Resolved
Provide material documenting compliance with maintenance, weekly and monthly inspections in accordance with 199.190
Condition: Unknown
Due 31 January 2000
Resolved 31 January 2000
Fire Fighting
Issued 31 January 2000 Resolved
Install latching devices at the bottom of all fire screen doors that currently have one latching mechanism on the upper section of each door. OrProvide acceptable alternative to configure these doors so that the door's consistently latch when closed and adequate door strength is maintained.
Condition: Unknown
Due 31 January 2000
Resolved 31 January 2000
Lifesaving
Issued 31 January 2000 Resolved
Update muster list and emergency instructions in accordance with 199.80 andprovide list and instructions for approval in accordance with 199.217
Condition: Unknown
Due 31 January 2000
Resolved 31 January 2000
Fire Fighting
Issued 22 December 1999 Resolved
Issued verbal 835 to repair all interior and exterior door latching devices.
Condition: Unknown
Due 22 December 1999
Resolved 22 December 1999
Engineering
Issued 25 October 1999 Resolved
CORRECT #3 SHIP'S SERVICE GENERATOR EXHAUST GASKET LEAK TO THE SATISFACTIONOF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 November 1999
Resolved 24 November 1999
Engineering
Issued 25 October 1999 Resolved
PROVIDE REVISED PERIODIC AUTOMATION TEST PROCEDURES I.A.W. CHIMS LETTER OF OCTOBER 1999, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. RE- QUIREMENT WILL BE CLEARED UPON APPROVAL OF SUBMITTED MATERIAL.
Condition: Unknown
Due 25 October 1999
Resolved 25 October 1999
Fire Fighting
Issued 25 October 1999 Resolved
PROVIDE QUALIFIED MEMBER OF ENGINEERING DEPARTMENT (QMED) TO MANUALLY ACTU-ATE #2 SPRINKLER PUMP SHOULD THE PRESSURE DROP BELOW 50PSI. MAINTAIN THIS UNTIL PROPER OPERATION OF #2 SPRINKLER PUMP DIFFERENTIAL PRESSURE SWITCH ISPROVEN TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 November 1999
Resolved 29 October 1999
Fire Fighting
Issued 25 October 1999 Resolved
PROVE PROPER OPERATION OF ZONE 01 TAMPER SWITCH TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 November 1999
Resolved 29 October 1999
Deck/Cargo
Issued 25 October 1999 Resolved
PROPERLY REPAIR OR REPLACE WITH NEW, ALL DAMAGED COMPONENTS OF THE ANCHOR WINDLASS WILDCAT REDUCTION GEARS PRIOR TO THE CARRAIGE OF PASSENGERS UNDER-WAY, BUT NO LATER THAN 31 JAN 00 AND TO PROVE PROPER OPERATION OF THE SAME TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR & THE COGNIZANT OCMI.
Condition: Unknown
Due 25 October 1999
Resolved 25 October 1999
Unknown
Issued 10 May 1999 Resolved
Remove all combustible storage items from hold HVAC room.
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Electrical
Issued 10 May 1999 Resolved
Make repairs to engine room alarm panel on bridge.
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Fire Fighting
Issued 10 May 1999 Resolved
Prove proper operation of engine room remote ventilation shutdowns.
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Engineering
Issued 10 May 1999 Resolved
Prove proper operation of alarm systems, #3 & 4, ships service generators.
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Fire Fighting
Issued 10 May 1999 Resolved
Prove proper operation of zone #4 sprinkler system tamper switch.
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Electrical
Issued 10 May 1999 Resolved
Install lock on breaker panel #231 on 3rd deck.
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Construction/Loadline
Issued 1 February 1999 Resolved
Prove proper closure of watertight door at Fr. 40
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Engineering
Issued 1 February 1999 Resolved
Provide plan for moving remote fuel oil shutoff reach rod handles outside main engine room.
Condition: Unknown
Due 24 February 1999
Resolved 11 February 1999
Electrical
Issued 1 February 1999 Resolved
Prove proper operation of #1,2,3,4 SSDG reverse power relays.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Documentation
Issued 26 October 1998 Resolved
PROVIDE THE FOLLOWING DOCUMENTS FIXED AND PORTABLE FIREFIGHTING SERVICING CERTIFICATES, ELEVATOR SERVICING CERTIFICATE AND CHEMICAL TESTING PROGRAM AUDIT.
Condition: Unknown
Due 28 November 1998
Resolved 27 November 1998
Electrical
Issued 26 October 1998 Resolved
UPDATE THE INDEX FOR ELECTRICAL PANEL #EOS24VDC.
Condition: Unknown
Due 28 November 1998
Resolved 27 November 1998
Navigation
Issued 26 October 1998 Resolved
SWING THE COMPASS AND UPDATE THE DEVIATON CARD.
Condition: Unknown
Due 28 November 1998
Resolved 27 November 1998
Electrical
Issued 26 October 1998 Resolved
PROVE PROPER OPERATION OF THE OVERSPEED TRIPS ON THE #2 & #3 SHIP SERVICE DIESEL GENERATOR.
Condition: Unknown
Due 28 November 1998
Resolved 27 November 1998
Fire Fighting
Issued 17 August 1998 Resolved
INSTALL MISSING PRESSURE RELIEF VALVES IN FIRE PUMP DISCHARGE PIPING PER 46CFR 76.10-5(d)
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Electrical
Issued 28 May 1998 Resolved
Complete repairs/replacement of all damaged generators prior to carrying passengers away from the dock, but in no case later than 28 Jun 98. Vesseloperations may continue as normal during dockside repairs.
Condition: Unknown
Due 28 June 1998
Resolved 11 August 1998
Documentation
Issued 11 May 1998 Resolved
PROVE COMPLIANCE WITH FCC GREAT LAKES RADIOTELEPHONE AGREEMENT.
Condition: Unknown
Due 25 May 1998
Resolved 7 August 1998
Electrical
Issued 11 May 1998 Resolved
PROVE OPERATION OF ALL CLASS 3 WATERTIGHT DOOR LIMIT SWITCHES AND TRAVEL OPERATION AND INDICATOR FLAG DEVICES.
Condition: Unknown
Due 18 May 1998
Resolved 7 August 1998
Engineering
Issued 11 May 1998 Resolved
INSTALL PRESSURE GAUGE ON EACH NON-FIRED PRESSURE VESSEL AND PROVE OPERATION OF EACH RELIEF VALVE.
Condition: Unknown
Due 25 May 1998
Resolved 7 August 1998
Fire Fighting
Issued 11 May 1998 Resolved
REINSTALL FIRESTOP IN LIQUOR TRUNK AT ORIGIN OF TRUNK IN LIQUOR ROOM.
Condition: Unknown
Due 18 May 1998
Resolved 7 August 1998
Electrical
Issued 11 May 1998 Resolved
CLEAR ELECTRICAL GROUND CURRENT FROM TRANSFORMERS 1, 2, AND 3 ON MAIN SWITCH BOARD.
Condition: Unknown
Due 18 May 1998
Resolved 7 August 1998
Electrical
Issued 11 May 1998 Resolved
CORRECT WIRING DEFICIENCIES IN BOTH PASSENGER AND SERVICE ELEVATORS AND PRESENT EVIDENCE OF SAME.
Condition: Unknown
Due 18 May 1998
Resolved 7 August 1998
Deck/Cargo
Issued 11 May 1998 Resolved
RENEW WORN NUMBER 2 MOORING LINE.
Condition: Unknown
Due 25 May 1998
Resolved 7 August 1998
Fire Fighting
Issued 11 May 1998 Resolved
INSTALL ONE ADDITIONAL CO2 ALARM IN AUXILARY MACHINERY SPACE.
Condition: Unknown
Due 25 May 1998
Resolved 7 August 1998
Electrical
Issued 26 January 1998 Resolved
INSTALL A DRIP SHIELD ON BATTERY CHARGER IN EMERGENCY GENERATOR.
Condition: Unknown
Due 28 February 1998
Resolved 23 April 1998
Lifesaving
Issued 26 January 1998 Resolved
PRIOR TO CARRYING PASSENGERS AWAY FROM THE DOCK, RENEW PROPER LOCKING PIN ON AFT/CENTER ESS.
Condition: Unknown
Due 28 February 1998
Resolved 23 April 1998
Engineering
Issued 26 January 1998 Resolved
PRIOR TO CARRYING PASSENGERS AWAY FROM THE DOCK, PROVE PROPER OPERATION OF NO. 3 THRUSTER UNIT SCR.
Condition: Unknown
Due 23 April 1998
Resolved 23 April 1998
Accommodation/Occupational Safety
Issued 27 October 1997 Resolved
Renew cracked window in pilothouse, port side.
Condition: Unknown
Due 27 November 1997
Resolved 18 December 1997
Electrical
Issued 27 October 1997 Resolved
SUBMIT A QUALITATIVE FAILURE ANALYSIS AND DESIGN VERIFICATION TEST PROCEDURE FOR ALL AUTOMATICALLY OR REMOTELY CONTROLLED VITAL SYSTEMS TO USCG MSC-2 AS REQUIRED BY USCG MSC-2 LETTER E2-9702725 DATED 20AUG97.
Condition: Unknown
Due 8 January 1998
Resolved 9 January 1998
Lifesaving
Issued 27 October 1997 Resolved
Prior to carrying passengers away from the dock, conduct satisfactory operational test of port side IBA launching rack in the presence of an attending marine inspector. Test specification as discussed with [name withheld], Director of Marine Operations on 24OCT97.
Condition: Unknown
Due 21 November 1997
Resolved 18 December 1997
Lifesaving
Issued 27 October 1997 Resolved
Prior to carrying passengers away from dock, reinstall and repack ESS and IBA's expended during crew drills held 23OCT97.
Condition: Unknown
Due 27 November 1997
Resolved 18 December 1997
Engineering
Issued 27 October 1997 Resolved
Install reach rods for all valves located below deck plates in the main machinery room.
Condition: Unknown
Due 27 November 1997
Resolved 18 December 1997
Fire Fighting
Issued 27 October 1997 Resolved
Install remote start switches for main and emergency fire pumps.
Condition: Unknown
Due 27 November 1997
Resolved 18 December 1997
Fire Fighting
Issued 27 October 1997 Resolved
Revise Fire and Safety Plan as indicated on the USCG "marked up" copy to accurately reflect the location and quantity of fire fighting, lifesaving and other indicated safety equipment.
Condition: Unknown
Due 27 November 1997
Resolved 18 December 1997
Lifesaving
Issued 4 September 1997 Resolved
POST APPROVED PLACARDS CONTAINING INSTRUCTIONS FOR LAUNCHING AND INFLATING BUOYANT APPARATUS AS REQUIRED BY 46 CFR 78.49-1.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Engineering
Issued 4 September 1997 Resolved
MARK THE EMERGENCY GENERATOR FUEL CUT-OFF PULL BOX.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Fire Fighting
Issued 4 September 1997 Resolved
PROVIDE THE VESSEL WITH AN INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Navigation
Issued 4 September 1997 Resolved
PROVIDE A PROPERLY DISPLAYED MANEUVERING INFORMATION SHEET IN THE WHEELHOUSE AS REQUIRED BY 33 CFR 164.35(G).
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Lifesaving
Issued 4 September 1997 Resolved
PROPERLY MARK INFLATABLE BUOYANT APPARATUS AS REQUIRED BY 46 CFR 78.47-63.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Electrical
Issued 4 September 1997 Resolved
MARK THE EOS SWITCHBOARDS APPROPRIATE TOP ROW TO INDICATE ALARMS ARE FOR THE PRIME MOVERS.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Documentation
Issued 4 September 1997 Resolved
PROPERLY MOUNT THE MARPOL GARBAGE PLACARDS.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Fire Fighting
Issued 4 September 1997 Resolved
PROPERLY MARK ALL FIRE DAMPERS.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Fire Fighting
Issued 4 September 1997 Resolved
PROVIDE INSTRUCTIONS FOR THE OPERATION, MAINTENANCE AND TESTING OF FIRE DETECTION SYSTEM, MANUAL PULL BOX ALARM SYSTEM, SPRINKLER SYSTEM AND AEVADSSYSTEM.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Lifesaving
Issued 4 September 1997 Resolved
PROPERLY INSTALL SUFFICIENT INFLATABLE BUOYANT APPARATUS WITH CURRENT SERVICE CERTIFICATES FOR TOTAL PERSONS ALLOWED ON BOARD AS REQUIRED BY 46 CFR 75.10
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Fire Fighting
Issued 4 September 1997 Resolved
PROVIDE COMPLETE INSTRUCTIONS FOR LOCAL OPERATION OF THE ENGINEROOM CO2 SYSTEM INCLUDING A SCHEMATIC DIAGRAM OF THE SYSTEM AND DETAILING ALTERNATE METHODS OF DISCHARGING THE SYSTEM DUE TO FAILURE OF MANUAL RELEASE/STOP VALVE AS REQUIRED BY 46 CFR 76.15-10(H).
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Electrical
Issued 4 September 1997 Resolved
PROVE PROPER OPERATION OF EMERGENCY ELECTRICAL CIRCUIT LIGHTING AT ALL IBA SLIDE LOCATIONS.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Fire Fighting
Issued 4 September 1997 Resolved
PROVIDE SIX (6) SPARE SPRINKLER HEADS.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Lifesaving
Issued 4 September 1997 Resolved
PROVIDE APPROVAL FOR ALL VITAL SYSTEM FLEX HOSES.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 4 September 1997 Resolved
MARK ALL BILGE MANIFOLD VALVES WITH THE COMPARTMENT SERVED.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Electrical
Issued 4 September 1997 Resolved
PROVIDE THE "E" LABELS ON ALL EMERGENCY LIGHTS.
Condition: Unknown
Due 10 October 1997
Resolved 10 October 1997
Lifesaving
Issued 4 September 1997 Resolved
MARK THE EOS AND PILOT HOUSE EMERCENCY STOPS WITH THE POSITION OF DEVICE OPERATION.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Engineering
Issued 4 September 1997 Resolved
PROVE PROPER OPERATION OF THE FUEL PURIFIER REMOTE SHUTDOWN.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 4 September 1997 Resolved
PLACE WATERTIGHT DOOR (TYPE III) PLACARDS WITH DOOR NUMBERS ON THE DOOR FRAME ON THE SIDE NOT VISIBLE WHEN DOORS ARE OPEN._x001C_ MARK REMOTE HYDRAULIC STATIONS WITH THE DOOR NUMBER.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Fire Fighting
Issued 4 September 1997 Resolved
REWELD THE LOWER DRAIN LINE BRACKET ON SPRINKLER ZONE 11 DRAIN LINE.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Fire Fighting
Issued 4 September 1997 Resolved
PROVE OPERATION OF FIRE SCREEN DOOR NO.39.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Electrical
Issued 4 September 1997 Resolved
SUBMIT A QUALITATIVE FAILURE ANALYSIS AND DESIGN VERIFICATION TEST PROCEDURE FOR ALL AUTOMATICALLY OR REMOTELY CONTROLLED VITAL SYSTEMS TO USCG MSC-2 AS REQUIRED BY USCG MSC-2 LETTER E2-9702725 DATED 20AUG97.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Documentation
Issued 4 September 1997 Resolved
POST ALL OFFICER LICENSES AS REQUIRED BY 46 CFR 78.65-1.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Documentation
Issued 4 September 1997 Resolved
POST FIRE CONTROL PLAN AS REQUIRED BY 46 CFR 78.45-1.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Fire Fighting
Issued 4 September 1997 Resolved
PROVIDE TAPED MESSAGES ON AEVADS SYSTEM TO [name withheld], AND TEST SYSTEM WHEN ALL EQUIPMENT IS OUTFITTED ON THE VESSEL.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Fire Fighting
Issued 4 September 1997 Resolved
CONDUCT OPERATIONAL TEST OF ALL FIRE DAMPERS.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Electrical
Issued 4 September 1997 Resolved
SUBMIT FOR APPROVAL TO USCG MSC THE FOLLOWING DRAWINGS: (A) SHORT CIRCUIT ANALYSIS. (B) ELECTRICAL LOAD ANALYSIS.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Electrical
Issued 4 September 1997 Resolved
SUBMIT FOR APPROVAL TO USCG MSC THE FOLLOWING ELEMENTARY AND ISOMETRIC WIRING PLANS: (A) POWER OPERATED BOAT WINCHES.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Documentation
Issued 4 September 1997 Resolved
PERMANENTLY MARK VESSEL'S OFFICIAL NUMBER ON INTERIOR STRUCTURAL PART OF HULL AS REQUIRED BY 46 CFR 67.121.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Lifesaving
Issued 4 September 1997 Resolved
PROVIDE SUFFICIENT CG APPROVED THERMAL PROTECTIVE AIDS FOR ALL ALLOWED PERSONS ONBOARD PLUS 10%.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Lifesaving
Issued 4 September 1997 Resolved
PROVIDE PORT AND STBD RESCUE BOATS.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Documentation
Issued 4 September 1997 Resolved
PROVIDE A CERTIFICATE OD DOCUMENTATION.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Navigation
Issued 4 September 1997 Resolved
PROVIDE REQUIRED CHARTS AND PUBLICATIONS FOR AREA OF OPERATION AND PLOTTINGEQUIPMENT AS REQUIRED BY 33 CFR 164.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Documentation
Issued 4 September 1997 Resolved
POST THE STATION BILL IN A CONSPICUOUS PLACES/LOCATIONS ON VESSEL AS REQUIRED BY 46 CFR 78.13-1.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Fire Fighting
Issued 4 September 1997 Resolved
SUBMIT FOR APPROVAL TO USCG MARINE SAFETY CENTER THE FIXED CO2 EXTINGUISHING SYSTEMS FOR THE ENGINE ROOM AND THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Lifesaving
Issued 4 September 1997 Resolved
PROVIDE TWO STERN INFLATABLE BUOYANT APPARATUS SLIDES AS REQUIRED BY 46 CFRSUBCHAPTER W.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Lifesaving
Issued 4 September 1997 Resolved
PROVIDE 50 CG APPROVED IMMERSION SUITS.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Lifesaving
Issued 4 September 1997 Resolved
PROVIDE SUFFICIENT LIFE PRESERVERS, PROPERLY MARKED AND STOWED, FOR THE TOTAL ALLOWED PERSONS ONBOARD, WITH ADDITIONAL PRESERVERS PROVIDED FOR BRIDGE AND ENGINEROOM WATCHSTANDERS AS REQUIRED BY 46 CFR 75.40-10.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Accommodation/Occupational Safety
Issued 4 September 1997 Resolved
RENEW THE BROKEN TREAD FRONT EDGING ON THE LOWER ESCALATOR.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997

Casualty record · 4

24 December 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2557287
1 August 2006Routine · role: Involved in a Marine Casualty · activity 2742664
12 March 2008Routine · role: Involved in a Marine Casualty · activity 3183837
10 February 2015Routine · role: Acknowledged Pollution Source · activity 5070993
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.