Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton 4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 12 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
30 January 2024Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7858389
22 November 2023Hull Examination · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7828583
26 July 2023Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7753996
11 July 2022Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7506944
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. The starboard pontoon has excessive wastage along the entire length and the aft port pontoon chamber is excessively wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 February 2024
Resolved 8 February 2024
Resolution: COI was surrendered.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2021Resolved
FUEL LINES MUST BE INSULATED TO PROTECT AGAINST CORROSION. STBD ENGINE FUEL LINE AND PRIME BULB FOUND CORRODED. REPLACE WITH APPROPRIATE FUEL LINE.
Action required: 10 - Deficiency Rectified
Due 20 August 2021
Resolved 20 July 2021
Resolution: CORRECTED PRIOR TO [name withheld].
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2021Resolved
EACH LIFEJACKET MUST BE MARKED WITH TYPE 1 RETROFLECTIVE MATERIAL. ELEVEN LIFEJACKETS FOUND WITH DEGRADED RETRO MATERIAL. REPLACE WITH RETRO MATERIAL.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2021
Resolved 20 July 2021
Resolution: PICTURES WERE EMAILED TO MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 July 2021Resolved
EACH RING LIFE BUOY MUST BE MARKED WITH TYPE II RETROFLECTIVE MATERIAL. LIFEBUOY FOUND WITH DEGRADED RETRO MATERIAL. REPLACE WITH RETRO MATERIAL.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2021
Resolved 20 July 2021
Resolution: PICTURES EMAILED TO MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 July 2021Resolved
THE WORDS "FIRE BUCKET" MUST BE STENCILED IN CONTRASTING COLOR ON EACH FIRE BUCKET. LABEL BUCKETS.
Action required: 10 - Deficiency Rectified
Due 20 August 2021
Resolved 20 July 2021
Resolution: CORRECTED PRIOR TO [name withheld].
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2019Resolved
The battery inside the float light was expired. A vessel must carry one floating water light. Replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 24 July 2019
Resolution: Corrected
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 July 2019Resolved
Two light fixtures do not have covers. Each lighting fixture must have a guard. Renew or remove fixtures.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 24 July 2019
Resolution: Corrected
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 15 July 2019Resolved
There was no fire emergency drill posted. The master of a vessel will have mounted at the operating station emergency instructions in the event of a fire. Post emergency procedure.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 24 July 2019
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 August 2018Resolved
Each lifejacket must be marked with retroreflective material. 04 lifejackets found with degraded retroreflective tape. Replace retroreflective tape on 04 lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2018
Resolved 14 August 2018
Resolution: 04 lifejackets were renewed with new retroreflective tape.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 August 2018Resolved
A vessel not required to have a fire pump must have three 2.5 gallon buckets stenciled "Fire bucket". One fire bucket not labelled. Label with "Fire bucket".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2018
Resolved 14 August 2018
Resolution: Fire bucket was labeled "Fire bucket".
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 August 2018Resolved
Vessel must carry an approved first aid kit. Alcohol and aspirin were expired. Replace alcohol and aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2018
Resolved 14 August 2018
Resolution: Alcohol and aspirin were replaced.
Engineering › Steering Gear System › Linkage
Issued 22 June 2017Resolved
The tie-bar between outboards currently hits/jams on outboard mounts. Modify to eliminate interferences.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 19 July 2017
Resolution: Adequate spacers were added to bring bar off the contact points.
Lifesaving › Hand Flares › Quantity
Issued 19 August 2016Resolved
Vessel shall have 6 flares on board. Three red and Three Orange or Six Red.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 19 August 2016
Resolution: Photo submitted with correct amount of distress signals.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 August 2016Resolved
Properly cap dead end wires under console.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 19 August 2016
Resolution: Deficiency corrected on the spot.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.