Records from 1997 to 1998. Most recent: inspection, 15 July 1998.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Construction/Loadline
Issued 12 June 1998
No resolution recorded
Repaint loadline with white or yellow paint, as per ICLL 1966, Annex 1, chp1, reg 8.
Condition: Unknown
Due 9 August 1998 — due date passed with no resolution recorded
Fire Fighting
Issued 12 June 1998
No resolution recorded
Provide evidence that the portable fire extinguishing system for the paint locker meets Administrations approval, as per SOLAS 92 11-2/18.7.
Condition: Unknown
Due 9 August 1998 — due date passed with no resolution recorded
Lifesaving
Issued 28 April 1998
Resolved
Port and Starboard lifeboats were missing the following equipment: bailers,lamp, proper amount of water, (3 liters per person), and sea sickness pillsfor each lifeboat._x001C_ SOLAS 74 amended CH. III/41.8_x001C_
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Electrical
Issued 28 April 1998
Resolved
Lighting and electrical fixtures/switches found in and around the vessel were missing covers, guards, or were a potential shock hazard. Locations include but not limited to the hospital space, oiler room A, galley, boat deck port head, above the strbrd generator, above the grinder, above the
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Fire Fighting
Issued 28 April 1998
Resolved
Vessel's aft paint locker on the 3nd deck above the main deck is missing a fixed fire suppression as required by SOLAS. Vsl required to correct priorto next U.S. port but not later than 28May98. SOLAS 74 amended CH. II- 2/18.7
Condition: Unknown
Due 13 July 1998
Resolved 26 June 1998
Unknown
Issued 9 August 1997
Resolved
While conducting a visual inspection of the vessel's bridge log, it was observed that the weekly operation of the lifeboat/rescue boat engines was being conducted monthly. Specific Cite: SOLAS 74(ammend) CH.III/Reg. 19.6.2
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Unknown
Issued 9 August 1997
Resolved
While visually inspecting the vessel's bridge log, it was observed that thetesting of the ship's general alarms was being conducted monthly. SpecificCite: SOLAS 74(ammend) CH.III/Reg. 19.6.3._x001C_ _x001C_
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Unknown
Issued 9 August 1997
Resolved
While conducting a deck walk, it was observed that the fuel tank vent flamescreens were either missing or had exsessive large holes. Specific Cite: SOLAS 74(ammend) CH.II-2/Reg. 15.2.
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Unknown
Issued 9 August 1997
Resolved
While conducting a visual inspection of the vessel's bridge log, it was observed that the weekly visual inspection of the survival craft/rescue boat was being conducted monthly. Specific Cite: SOLAS 74 (ammend) CH.III/Reg. 19.6.1_x001C_
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Unknown
Issued 9 August 1997
Resolved
While visually inspecting the vessel's life bouys during the deck walk, it was observed that the retroflective tape had faded due to exposure to the sun. Specific Cite: SOLAS 74(ammedn) CH.III/Reg.30.2.7_x001C_ _x001C_
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Unknown
Issued 9 August 1997
Resolved
While conducting the abandon ship drill, it was observed that the lifeboat breaking systen did not operat to the original design specifications in that it could not be operated from the life boat or remote area aft of the davit. Specific Cite: SOLAS 74(ammend) CH.III/Reg.19.2_x001C_
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Unknown
Issued 9 August 1997
Resolved
While conducting the fire fighting drill, it was observed that the fireman's lifeline was was not of a fire proof material. Specific Cite: SOLAS 74(ammend) CH.II-2/Reg.17.2_x001C_ _x001C_
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Unknown
Issued 9 August 1997
Resolved
While inspecting the inside/outside of the vessel's super structureit was observed that some of the light fixtures were missing globes and protectiveshielding. Specific Cite: SOLAS 74(ammend) CH.II-1/Reg.40_x001C_ _x001C_
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Unknown
Issued 9 August 1997
Resolved
During the abandon ship drill, it was observed that the starboard liferaft did not have operating instructions posted. Specific Cite: SOLAS 74(ammed)CH.III/Reg.9_x001C_ _x001C_
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Unknown
Issued 9 August 1997
Resolved
While conducting the abandon ship drill, it was observed that the operatinginstuctions for both the port and starboard life boat were for a different design of life boat. Specific Cite: SOLAS 74(ammed) CH.III/Reg.9_x001C_ _x001C_
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Unknown
Issued 9 August 1997
Resolved
While conducting the deck walk, it was observed that two of the fire stations were missing the fire nozzle. Specific Cite: SOLAS 74(ammed) CH.II-2/Reg.21._x001C_ _x001C_
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997